Health, work performance, and risk of infection in office-like environments: The role of indoor temperature, air humidity, and ventilation
The DOI matches its Crossref record; 127 of the 127 references it cites were found in a registry or an index.
Abstract
Epidemiological and experimental studies have revealed the effects of the room temperature, indoor air humidity, and ventilation on human health, work and cognitive performance, and risk of infection. In this overview, we integrate the influence of these important microclimatic parameters and assess their influence in offices based on literature searches. The dose-effect curves of the temperature describe a concave shape. Low temperature increases the risk of cardiovascular and respiratory diseases and elevated temperature increases the risk of acute non-specific symptoms, e.g., dry eyes, and respiratory symptoms. Cognitive and work performance is optimal between 22 °C and 24 °C for regions with temperate or cold climate, but both higher and lower temperatures may deteriorate the performances and learning efficiency. Low temperature may favor virus viability, however, depending on the status of the physiological tissue in the airways. Low indoor air humidity causes vulnerable eyes and airways from desiccation and less efficient mucociliary clearance. This causes elevation of the most common mucous membrane-related symptoms, like dry and tired eyes, which deteriorates the work performance. Epidemiological, experimental, and clinical studies support that intervention of dry indoor air conditions by humidification alleviates symptoms of dry eyes and airways, fatigue symptoms, less complaints about perceived dry air, and less compromised work performance. Intervention of dry air conditions by elevation of the indoor air humidity may be a non-pharmaceutical treatment of the risk of infection by reduced viability and transport of influenza virus. Relative humidity between 40 and 60% appears optimal for health, work performance, and lower risk of infection. Ventilation can reduce both acute and chronic health outcomes and improve work performance, because the exposure is reduced by the dilution of the indoor air pollutants (including pathogens, e.g., as virus droplets), and in addition to general emission source control strategies. Personal control of ventilation appears an important factor that influences the satisfaction of the thermal comfort due to its physical and positive psychological impact. However, natural ventilation or mechanical ventilation can become sources of air pollutants, allergens, and pathogens of outdoor or indoor origin and cause an increase in exposure. The "health-based ventilation rate" in a building should meet WHO's air quality guidelines and dilute human bio-effluent emissions to reach an acceptable perceived indoor air quality. Ventilation is a modifying factor that should be integrated with both the indoor air humidity and the room temperature in a strategic joint control to satisfy the perceived indoor air quality, health, working performance, and minimize the risk of infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · The Lancet Microbe · doi:10.1016/s2666-5247(20)30003-3 · Cited by 1,946
Influenza Virus Transmission Is Dependent on Relative Humidity and Temperature
Lowen, A. C., Mubareka, S., Steel, J., & Palese, P. (2007) · PLoS Pathogens · doi:10.1371/journal.ppat.0030151 · Cited by 1,669
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
Seasonality of Respiratory Viral Infections
Moriyama, M., Hugentobler, W. J., & Iwasaki, A. (2020) · Annual Review of Virology · doi:10.1146/annurev-virology-012420-022445 · Cited by 1,266
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Recognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Effects of Air Temperature and Relative Humidity on Coronavirus Survival on Surfaces
Casanova, L. M., Jeon, S., Rutala, W. A., Weber, D. J., & Sobsey, M. D. (2010) · Applied and Environmental Microbiology · doi:10.1128/aem.02291-09 · Cited by 735
Indoor air humidity, air quality, and health – An overview
Wolkoff, P. (2018) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.01.015 · Cited by 662
Self-citationDroplet fate in indoor environments, or can we prevent the spread of infection?
Morawska, L. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00432.x · Cited by 635
Carbon dioxide generation rates for building occupants
Persily, A., & de Jonge, L. (2017) · Indoor Air · doi:10.1111/ina.12383 · Cited by 566
Human Occupancy as a Source of Indoor Airborne Bacteria
Hospodsky, D., Qian, J., Nazaroff, W. W., Yamamoto, N., Bibby, K., Rismani-Yazdi, H., & Peccia, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0034867 · Cited by 562
Indirect health effects of relative humidity in indoor environments.
Arundel, A. V., Sterling, E. M., Biggin, J. H., & Sterling, T. D. (1986) · Environmental Health Perspectives · doi:10.1289/ehp.8665351 · Cited by 525
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
2019 Novel Coronavirus (COVID-19) Pandemic: Built Environment Considerations To Reduce Transmission
Dietz, L., Horve, P. F., Coil, D. A., Fretz, M., Eisen, J. A., & Van Den Wymelenberg, K. (2020) · mSystems · doi:10.1128/msystems.00245-20 · Cited by 491
Marr, L. C., Tang, J. W., Van Mullekom, J., & Lakdawala, S. S. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0298 · Cited by 430
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Azuma, K., Kagi, N., Yanagi, U., & Osawa, H. (2018) · Environment International · doi:10.1016/j.envint.2018.08.059 · Cited by 403
Self-citationThe impact of thermal environment on occupant IEQ perception and productivity
Geng, Y., Ji, W., Lin, B., & Zhu, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.022 · Cited by 388
Fang, L., Wyon, D. P., Clausen, G., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00276.x · Cited by 380
High Temperature (30°C) Blocks Aerosol but Not Contact Transmission of Influenza Virus
Lowen, A. C., Steel, J., Mubareka, S., & Palese, P. (2008) · Journal of Virology · doi:10.1128/jvi.00325-08 · Cited by 351
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Self-citationLow ambient humidity impairs barrier function and innate resistance against influenza infection
Kudo, E., Song, E., Yockey, L. J., Rakib, T., Wong, P. W., Homer, R. J., & Iwasaki, A. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1902840116 · Cited by 341
Increasing Temperature and Relative Humidity Accelerates Inactivation of SARS-CoV-2 on Surfaces
Biryukov, J., Boydston, J. A., Dunning, R. A., Yeager, J. J., Wood, S., Reese, A. L., Ferris, A., Miller, D., Weaver, W., Zeitouni, N. E., et al. (2020) · mSphere · doi:10.1128/msphere.00441-20 · Cited by 318
Walking-induced particle resuspension in indoor environments
Qian, J., Peccia, J., & Ferro, A. R. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.02.035 · Cited by 305
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290
Seppänen, O., & Fisk, W. J. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01111.x · Cited by 277
Lin, K., & Marr, L. C. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b04959 · Cited by 266
Azuma, K., Yanagi, U., Kagi, N., Kim, H., Ogata, M., & Hayashi, M. (2020) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-020-00904-2 · Cited by 263
Self-citationSurvival Characteristics of Airborne Human Coronavirus 229E
Ijaz, M. K., Brunner, A. H., Sattar, S. A., Nair, R. C., & Johnson-Lussenburg, C. M. (1985) · Journal of General Virology · doi:10.1099/0022-1317-66-12-2743 · Cited by 254
A Method to Estimate the Chronic Health Impact of Air Pollutants in U.S. Residences
Logue, J. M., Price, P. N., Sherman, M. H., & Singer, B. C. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104035 · Cited by 251
Summary of human responses to ventilation
Seppanen, O. A., & Fisk, W. J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00279.x · Cited by 249
European Indoor Air Quality Audit Project in 56 Office Buildings
Bluyssen, P. M., Oliveira Fernandes, E., Groes, L., Clausen, G., Fanger, P. O., Valbjorn, O., Bernhard, C. A., & Roulet, C. A. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00002.x · Cited by 237
Reducing burden of disease from residential indoor air exposures in Europe (HEALTHVENT project)
Asikainen, A., Carrer, P., Kephalopoulos, S., Fernandes, E. D. O., Wargocki, P., & Hänninen, O. (2016) · Environmental Health · doi:10.1186/s12940-016-0101-8 · Cited by 229
Self-citationEffects of moderate thermal environments on cognitive performance: A multidisciplinary review
Zhang, F., de Dear, R., & Hancock, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.005 · Cited by 217
Cedeño Laurent, J. G., Williams, A., Oulhote, Y., Zanobetti, A., Allen, J. G., & Spengler, J. D. (2018) · PLoS Medicine · doi:10.1371/journal.pmed.1002605 · Cited by 205
Ahlawat, A., Wiedensohler, A., & Mishra, S. K. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.06.0302 · Cited by 198
Dabisch, P., Schuit, M., Herzog, A., Beck, K., Wood, S., Krause, M., Miller, D., Weaver, W., Freeburger, D., Hooper, I., et al. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1829536 · Cited by 197
Tsutsumi, H., Tanabe, S.-I., Harigaya, J., Iguchi, Y., & Nakamura, G. (2007) · Building and Environment · doi:10.1016/j.buildenv.2006.06.037 · Cited by 195
Relative Contributions of Four Exposure Pathways to Influenza Infection Risk
Nicas, M., & Jones, R. M. (2009) · Risk Analysis · doi:10.1111/j.1539-6924.2009.01253.x · Cited by 190
Indoor CO 2 concentrations and cognitive function: A critical review
Du, B., Tandoc, M. C., Mack, M. L., & Siegel, J. A. (2020) · Indoor Air · doi:10.1111/ina.12706 · Cited by 190
Thermal stress, human performance, and physical employment standards
Cheung, S. S., LEE, J. K. W., & Oksa, J. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0518 · Cited by 189
Prolonged Infectivity of SARS-CoV-2 in Fomites
Pastorino, B., Touret, F., Gilles, M., de Lamballerie, X., & Charrel, R. N. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2609.201788 · Cited by 187
Viral infections acquired indoors through airborne, droplet or contact transmission.
Rosa, G. L., Fratini, M., Libera, S. D., Iaconelli, M., & Muscillo, M. (2013) · PubMed · doi:10.4415/ann_13_02_03 · Cited by 186
Effect of voicing and articulation manner on aerosol particle emission during human speech
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M., & Ristenpart, W. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227699 · Cited by 176
Carrer, P., Wargocki, P., Fanetti, A., Bischof, W., De Oliveira Fernandes, E., Hartmann, T., Kephalopoulos, S., Palkonen, S., & Seppänen, O. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.08.011 · Cited by 172
Self-citationZhang, F., Haddad, S., Nakisa, B., Rastgoo, M. N., Cândido, C., Tjondronegoro, D., & de Dear, R. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.048 · Cited by 169
Wang, X., Li, D., Menassa, C. C., & Kamat, V. R. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.05.012 · Cited by 168
Vimalanathan, K., & Babu, T. R. (2014) · Journal of Environmental Health Science and Engineering · doi:10.1186/s40201-014-0113-7 · Cited by 167
Bluyssen, P. M., Roda, C., Mandin, C., Fossati, S., Carrer, P., de Kluizenaar, Y., Mihucz, V. G., de Oliveira Fernandes, E., & Bartzis, J. (2016) · Indoor Air · doi:10.1111/ina.12196 · Cited by 167
Self-citationField measurement of ventilation rates
Persily, A. K. (2016) · Indoor Air · doi:10.1111/ina.12193 · Cited by 164
Zhang, X., Wargocki, P., & Lian, Z. (2017) · Indoor Air · doi:10.1111/ina.12286 · Cited by 164
Maddalena, R. L., Mendell, M. J., Eliseeva, K., Chan, W. R., Sullivan, D. P., Russell, M., Satish, U., & Fisk, W. J. (2014) · Indoor Air · doi:10.1111/ina.12149 · Cited by 160
Building health: an epidemiological study of “sick building syndrome” in the Whitehall II study
Marmot, A. F., Eley, J., Stafford, M., Stansfeld, S. A., Warwick, E., & Marmot, M. G. (2006) · Occupational and Environmental Medicine · doi:10.1136/oem.2005.022889 · Cited by 150
Effect of exposure of human skin to a dry environment
Egawa, M., Oguri, M., Kuwahara, T., & Takahashi, M. (2002) · Skin Research and Technology · doi:10.1034/j.1600-0846.2002.00351.x · Cited by 147
Snow, S., Boyson, A., Paas, K. H. W., Gough, H., King, M., Barlow, J. F., Noakes, C. J., & schraefel, M. C. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.010 · Cited by 147
Perceptual and physiological responses of elderly subjects to moderate temperatures
Xiong, J., Ma, T., Lian, Z., & de Dear, R. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.012 · Cited by 144
Pathophysiology of nasal congestion
Naclerio, R. (2010) · International Journal of General Medicine · doi:10.2147/ijgm.s8088 · Cited by 142
Indoor Air Quality in the 21st Century: Search for Excellence
Fanger, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010002068.x · Cited by 139
Medical diagnostics for indoor mold exposure
Hurraß, J., Heinzow, B., Aurbach, U., Bergmann, K., Bufe, A., Buzina, W., Cornely, O. A., Engelhart, S., Fischer, G., Gabrio, T., et al. (2016) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2016.11.012 · Cited by 136
Kwon, M., Remøy, H., van den Dobbelsteen, A., & Knaack, U. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.021 · Cited by 135
Lu, C., Lin, J., Chen, Y.-Y., & Chen, Y. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph120605833 · Cited by 132
An Integrated Model of Infection Risk in a Health‐Care Environment
Nicas, M., & Sun, G. (2006) · Risk Analysis · doi:10.1111/j.1539-6924.2006.00802.x · Cited by 130
Yeganeh, A. J., Reichard, G., McCoy, A. P., Bulbul, T., & Jazizadeh, F. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.07.002 · Cited by 122
Mendell, M. J., Lei-Gomez, Q., Mirer, A. G., Seppnen, O., & Brunner, G. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00531.x · Cited by 120
Carrer, P., & Wolkoff, P. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15040741 · Cited by 117
Self-citationHong, J., Zhong, T., Li, H., Xu, J., Ye, X., Mu, Z., Lü, Y., Mashaghi, A., Zhou, Y., Tan, M., et al. (2016) · Scientific Reports · doi:10.1038/srep23858 · Cited by 113
Maula, H., Hongisto, V. O., Östman, L., Haapakangas, A., Koskela, H., & Hyönä, J. (2015) · Indoor Air · doi:10.1111/ina.12209 · Cited by 112
Azuma, K., Ikeda, K., Kagi, N., Yanagi, U., & Osawa, H. (2014) · Indoor Air · doi:10.1111/ina.12158 · Cited by 111
Self-citationMaula, H., Hongisto, V. O., Naatula, V., Haapakangas, A., & Koskela, H. (2017) · Indoor Air · doi:10.1111/ina.12387 · Cited by 106
Association between Dry Eye Disease, Air Pollution and Weather Changes in Taiwan
Zhong, J.-Y., Lee, Y., Hsieh, C., Tseng, C., & Yiin, .-M. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15102269 · Cited by 105
Fan, X., Liu, W., & Wargocki, P. L. (2018) · Indoor Air · doi:10.1111/ina.12523 · Cited by 104
House dust in seven Danish offices
Mølhave, L., Schneider, T., Kjærgaard, S. K., Larsen, L. D., Norn, S., & Jørgensen, O. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00104-7 · Cited by 102
Shan, X., Zhou, J. Z., Chang, V. W.-C., & Yang, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.03.025 · Cited by 101
Feng, Z., Zhou, X., Xu, S., Ding, J., & Cao, S. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.02.011 · Cited by 95
Mold and Human Health: a Reality Check
Borchers, A. T., Chang, C. C.-C., & Gershwin, M. E. (2017) · Clinical Reviews in Allergy & Immunology · doi:10.1007/s12016-017-8601-z · Cited by 92
Baughman, A., & Arens, E. A. (1996) · ASHRAE winter conference papers · Cited by 90
The Effects of Ventilation in Homes on Health
Wargocki, P. L. (2013) · International Journal of Ventilation · doi:10.1080/14733315.2013.11684005 · Cited by 90
Wellbuilt for wellbeing: Controlling relative humidity in the workplace matters for our health
Razjouyan, J., Lee, H., Gilligan, B., Lindberg, C. M., Nguyen, H., Canada, K., Burton, A., Sharafkhaneh, A., Srinivasan, K. K., Currim, F., et al. (2019) · Indoor Air · doi:10.1111/ina.12618 · Cited by 90
Do Indoor CO2 Levels Directly Affect Perceived Air Quality, Health, or Work Performance?
Fisk, W. J., Wargocki, P. L., & Zhang, X. (2019) · ASHRAE journal · Cited by 90
Lan, L., Xia, L., Hejjo, R., Wyon, D. P., & Wargocki, P. L. (2020) · Indoor Air · doi:10.1111/ina.12685 · Cited by 89
The German approach to regulate indoor air contaminants
Fromme, H., Dębiak, M., Sagunski, H., Röhl, C., Kraft, M., & Kolossa‐Gehring, M. (2019) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.12.012 · Cited by 88
Rethinking Air Quality and Climate Change after COVID-19
Ching, J., & Kajino, M. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17145167 · Cited by 87
On the Development of Health-Based Ventilation Guidelines: Principles and Framework
Carrer, P., Fernandes, E. D. O., Santos, H., Hänninen, O., Kephalopoulos, S., & Wargocki, P. L. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15071360 · Cited by 82
Self-citationThe mystery of dry indoor air – An overview
Wolkoff, P. (2018) · Environment International · doi:10.1016/j.envint.2018.10.053 · Cited by 82
Self-citationDerby, M. M., Hamehkasi, M., Eckels, S. J., Hwang, G. M., Jones, B., Maghirang, R. G., & Shulan, D. J. (2016) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1206430 · Cited by 80
Abbasi, A. M., Motamedzade, M., Aliabadi, M., Golmohammadi, R., & Tapak, L. (2019) · Health Promotion Perspectives · doi:10.15171/hpp.2019.07 · Cited by 80
Indoor air chemistry: Terpene reaction products and airway effects
Wolkoff, P. (2020) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2019.113439 · Cited by 79
Self-citationXiong, L., Huang, X., Li, J., Mao, P., Wang, X., Wang, R., & Tang, M. X. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15061256 · Cited by 77
Minor degree of hypohydration adversely influences cognition: a mediator analysis
Benton, D., Jenkins, K., Watkins, H., & Young, H. A. (2016) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.116.132605 · Cited by 70
Zhang, F., & de Dear, R. (2017) · Indoor Air · doi:10.1111/ina.12296 · Cited by 65
Video Display Operator Complaints: A 10-Year Follow-Up of Visual Fatigue and Refractive Disorders
Filon, F. L., Drusian, A., Ronchese, F., & Negro, C. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16142501 · Cited by 65
Azuma, K., Ikeda, K., Kagi, N., Yanagi, U., & Osawa, H. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.10.147 · Cited by 62
Self-citationViral kinetics and exhaled droplet size affect indoor transmission dynamics of influenza infection
CHEN, S. C., Chio, C., Jou, L., & Liao, C. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00603.x · Cited by 60
Barbic, F., Minonzio, M., Cairo, B., Shiffer, D., Dipasquale, A., Cerina, L., Vatteroni, A., Urechie, V., Verzeletti, P., Badilini, F., et al. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab1816 · Cited by 60
Hydrating the respiratory tract: An alternative explanation why masks lower severity of COVID-19
Courtney, J. M., & Bax, A. (2021) · Biophysical Journal · doi:10.1016/j.bpj.2021.02.002 · Cited by 59
Chan, W. R., Parthasarathy, S., Fisk, W. J., & McKone, T. E. (2015) · Indoor Air · doi:10.1111/ina.12189 · Cited by 58
Frankel, M., Hansen, E. W., & Madsen, A. M. (2013) · Indoor Air · doi:10.1111/ina.12055 · Cited by 57
The risk of airborne influenza transmission in passenger cars
Knibbs, L. D., Morawska, L., & Bell, S. C. (2011) · Epidemiology and Infection · doi:10.1017/s0950268811000835 · Cited by 56
Azuma, K., Ikeda, K., Kagi, N., Yanagi, U., & Osawa, H. (2017) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-017-0645-4 · Cited by 56
Self-citationMadsen, A. M. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.07879-11 · Cited by 54
Dry eye symptoms in offices and deteriorated work performance – A perspective
Wolkoff, P. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106704 · Cited by 51
Self-citationHong, T., Kim, J., & Lee, M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.07.063 · Cited by 47
Climate and the eye: Case-crossover analysis of retinal detachment after exposure to ambient heat
Auger, N., Rhéaume, M., Bilodeau‐Bertrand, M., Tang, T., & Kosatsky, T. (2017) · Environmental Research · doi:10.1016/j.envres.2017.05.017 · Cited by 44
Risk assessment concepts and approaches for indoor air chemicals in Japan
Azuma, K., Jinno, H., Tanaka‐Kagawa, T., & SAKAI, S. (2020) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2020.113470 · Cited by 44
Self-citationWu, J. S., Hou, Z., Shen, J., & Lian, Z. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107286 · Cited by 44
The impact of indoor thermal stratification on the dispersion of human speech droplets
Liu, F., Qian, H., Luo, Z., & Zheng, X. (2020) · Indoor Air · doi:10.1111/ina.12737 · Cited by 42
Observations on the ability of the nose to warm and humidify inspired air.
Naclerio, R. M., Pinto, J. M., Assanasen, P., & Baroody, F. M. (2007) · PubMed · Cited by 41
Nielsen, G. D., & Wolkoff, P. (2017) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2017.09.015 · Cited by 41
Self-citationAssociation Between Season, Temperature and Causative Organism in Microbial Keratitis in the UK
Walkden, A., Fullwood, C., Tan, S. Z., Au, L., Armstrong, M., Brahma, A. K., Chidambaram, J. D., & Carley, F. M. (2018) · Cornea · doi:10.1097/ico.0000000000001748 · Cited by 40
On the Optimal Indoor Air Conditions for SARS-CoV-2 Inactivation. An Enthalpy-Based Approach
Spena, A., Palombi, L., Corcione, M., Carestia, M., & Spena, V. A. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176083 · Cited by 40
Humidity as a non-pharmaceutical intervention for influenza A
Reiman, J. M., Das, B. B., Sindberg, G. M., Urban, M. D., Hammerlund, M. E. M., Lee, H. B., Spring, K. M., Gingerich, J. L., Generous, A. R., Koep, T. H., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204337 · Cited by 39
Destaillats, H., Chen, W., Apte, M. G., Li, N., Spears, M., Almosni, J., Brunner, G., Zhang, J., & Fisk, W. J. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.03.066 · Cited by 38
Aerosol influenza transmission risk contours: A study of humid tropics versus winter temperate zone
Hanley, B. P., & Borup, B. (2010) · Virology Journal · doi:10.1186/1743-422x-7-98 · Cited by 38
Liao, W., Zhou, L., Zhao, X., Song, L., Lu, Y., Zhong, N., Yang, P., Sun, B., & Zhang, X. (2017) · Scientific Reports · doi:10.1038/s41598-017-07471-7 · Cited by 33
Saeki, K., Obayashi, K., & Kurumatani, N. (2017) · Journal of Epidemiology · doi:10.1016/j.je.2016.12.018 · Cited by 31
Richardson, M., Li, P., Gohlke, J. M., & Allison, D. B. (2018) · Obesity · doi:10.1002/oby.22328 · Cited by 27
Brown, V. M., Crump, D., & Harrison, P. T. C. (2013) · Environmental Science Processes & Impacts · doi:10.1039/c3em00413a · Cited by 26
Probabilistic indoor transmission modeling for influenza (sub)type viruses
Chen, S., & Liao, C. (2009) · Journal of Infection · doi:10.1016/j.jinf.2009.09.015 · Cited by 23
Association between Retinal Nerve Fiber Layer Thickness and Eye Fatigue
Ayaki, M., Kuze, M., Kondo, M., Tsubota, K., & Negishi, K. (2019) · BioMed Research International · doi:10.1155/2019/3014567 · Cited by 19
Beziehungen zwischen Luftverunreinigung und Wohlbefinden
Bullinger, M. (1989) · Sozial- und Präventivmedizin · doi:10.1007/bf02083446 · Cited by 10
Improving brain power by applying a cool TRPM8 receptor agonist to the eyelid margin
Wei, E. T. (2020) · Medical Hypotheses · doi:10.1016/j.mehy.2020.109747 · Cited by 9
Metadata
- Authors
- Wolkoff, P., Azuma, K., & Carrer, P.
- Venue
- International Journal of Hygiene and Environmental Health
- Publisher
- Elsevier BV
- Published
- 2021-04
- Volume
- 233
- Pages
- 113709
- ISSN
- 1438-4639 (ISSN-L)
- OpenAlex
- W3129355703
- Cited by
- 279
- References
- 127
- FWCI
- 14.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.