The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Monitored Atrial Fibrillation Duration Predicts Arterial Embolic Events in Patients Suffering From Bradycardia and Atrial Fibrillation Implanted With Antitachycardia Pacemakers
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
(1994) · Archives of Internal Medicine · doi:10.1001/archinte.1994.00420130036007 · Cited by 2,071
Antithrombotic Therapy To Prevent Stroke in Patients with Atrial Fibrillation: A Meta-Analysis
Hart, R. G., Benavente, O., McBride, R., & Pearce, L. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00003 · Cited by 1,638
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Left Atrial Size and the Risk of Stroke and Death: The Framingham Heart Study
Benjamin, E. J., D’Agostino, R. B., Belanger, A. J., Wolf, P. A., & Levy, D. (1995) · Circulation · doi:10.1161/01.cir.92.4.835 · Cited by 1,055
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., Leon, A., Yee, R., Marinchak, R. A., Flaker, G., Schron, E., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 997
Hylek, E. M., Skates, S. J., Sheehan, M. A., & Singer, D. E. (1996) · New England Journal of Medicine · doi:10.1056/nejm199608223350802 · Cited by 789
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
Self-citation2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Antithrombotic Therapy in Atrial Fibrillation
Singer, D. E., Albers, G. W., Dalen, J. E., Fang, M. C., Go, A. S., Halperin, J. L., Lip, G. Y. H., & Manning, W. J. (2008) · Chest · doi:10.1378/chest.08-0678 · Cited by 751
Khairy, P., Van Hare, G. F., Balaji, S., Berul, C. I., Cecchin, F., Cohen, M. I., Daniels, C. J., Deal, B. J., Dearani, J. A., Groot, N. D., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.05.009 · Cited by 709
Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT
Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx042 · Cited by 599
Self-citationHalcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Andrade, J. G., Aguilar, M., Atzema, C., Bell, A., Cairns, J. A., Cheung, C. C., Cox, J. L., Dorian, P., Gladstone, D. J., Healey, J. S., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.09.001 · Cited by 562
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Self-citationSlotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Chen, L. Y., Chung, M. K., Allen, L. A., Ezekowitz, M., Furie, K. L., McCabe, P., Noseworthy, P. A., Perez, M. V., & Turakhia, M. P. (2018) · Circulation · doi:10.1161/cir.0000000000000568 · Cited by 439
Boriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Self-citationHindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Self-citationNieuwlaat, R., Capucci, A., Lip, G. Y. H., Olsson, S. B., Prins, M. H., Nieman, F. H., Lopez-Sendon, J., Vardas, P. E., Aliot, E., Santini, M., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl015 · Cited by 369
Self-citationMartin, D. T., Bersohn, M. M., Waldo, A. L., Wathen, M. S., Choucair, W. K., Lip, G. Y. H., Ip, J., Holcomb, R., Akar, J. G., & Halperin, J. L. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv115 · Cited by 364
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Self-citationLandolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Lip, G. Y., Tse, H. F., & Lane, D. A. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61514-6 · Cited by 338
Clinical Outcomes of Catheter Substrate Ablation for High-Risk Patients With Atrial Fibrillation
Nademanee, K., Schwab, M. C., Kosar, E. M., Karwecki, M., Moran, M. D., Visessook, N., Michael, A. D., & Ngarmukos, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.044 · Cited by 319
Go, A. S., Reynolds, K., Yang, J., Gupta, N., Lenane, J., Sung, S. H., Harrison, T. N., Liu, T. I., & Solomon, M. D. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1176 · Cited by 286
Stroke Risk as a Function of Atrial Fibrillation Duration and CHA 2 DS 2 -VASc Score
Kaplan, R. M., Koehler, J., Ziegler, P. D., Sarkar, S., Zweibel, S., & Passman, R. S. (2019) · Circulation · doi:10.1161/circulationaha.119.041303 · Cited by 284
Comparison of continuous versus intermittent monitoring of atrial arrhythmias
Ziegler, P. D., Koehler, J. L., & Mehra, R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.030 · Cited by 282
Themistoclakis, S., Corrado, A., Marchlinski, F. E., Jais, P., Zado, E., Rossillo, A., Di Biase, L., Schweikert, R. A., Saliba, W. I., Horton, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.039 · Cited by 276
Seet, R. C. S., Friedman, P. A., & Rabinstein, A. A. (2011) · Circulation · doi:10.1161/circulationaha.111.029801 · Cited by 276
Mahajan, R., Perera, T., Elliott, A. D., Twomey, D. J., Kumar, S., Munwar, D. A., Khokhar, K. B., Thiyagarajah, A., Middeldorp, M. E., Nalliah, C. J., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx731 · Cited by 275
Poole, J. E., Bahnson, T. D., Monahan, K. H., Johnson, G., Rostami, H., Silverstein, A. P., Al-Khalidi, H. R., Rosenberg, Y., Mark, D. B., Lee, K. L., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.04.065 · Cited by 268
Reiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Wachter, R., Pouliot, E., Ziegler, P. D., & for the REVEAL AF Investigators (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3180 · Cited by 265
Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
Cotter, P. E., Martin, P. J., Ring, L., Warburton, E. A., Belham, M., & Pugh, P. J. (2013) · Neurology · doi:10.1212/wnl.0b013e31828f1828 · Cited by 254
Management of atrial fibrillation
Lip, G. Y., & Tse, H.-F. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61300-2 · Cited by 229
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
Kirchhof, P., Bax, J., Blomstrom-Lundquist, C., Calkins, H., Camm, A. J., Cappato, R., Cosio, F., Crijns, H., Diener, H.-C., Goette, A., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp235 · Cited by 202
Noseworthy, P. A., Kaufman, E. S., Chen, L. Y., Chung, M. K., Elkind, M. S. V., Joglar, J. A., Leal, M. A., McCabe, P. J., Pokorney, S. D., Yao, X., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000740 · Cited by 171
Sanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Hanke, T., Charitos, E. I., Stierle, U., Karluss, A., Kraatz, E., Graf, B., Hagemann, A., Misfeld, M., & Sievers, H. H. (2009) · Circulation · doi:10.1161/circulationaha.108.838474 · Cited by 121
PASSMAN, R., LEONG‐SIT, P., ANDREI, A., HUSKIN, A., TOMSON, T. T., BERNSTEIN, R., ELLIS, E., WAKS, J. W., & ZIMETBAUM, P. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12864 · Cited by 115
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102
Self-citationClinical significance of atrial fibrillation detected by cardiac implantable electronic devices
DeCicco, A. E., Finkel, J. B., Greenspon, A. J., & Frisch, D. R. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.01.001 · Cited by 38
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
Swanson, D. R. (2008) · Medical Hypotheses · doi:10.1016/j.mehy.2008.02.017 · Cited by 27
Monitoring capabilities of cardiac rhythm management devices
Andrikopoulos, G., Tzeis, S., Theodorakis, G., & Vardas, P. (2010) · Europace · doi:10.1093/europace/eup317 · Cited by 5
Metadata
- Authors
- Capucci, A., Santini, M., Padeletti, L., Gulizia, M., Botto, G., Boriani, G., Ricci, R., Favale, S., Zolezzi, F., Di Belardino, N., Molon, G., Drago, F., Villani, G. Q., Mazzini, E., Vimercati, M., & Grammatico, A.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2005-11
- Volume
- 46
- Issue
- 10
- Pages
- 1913-1920
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2044480428
- Cited by
- 401
- References
- 42
- FWCI
- 10.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.