The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Open accessAbstract
Magnetic Particle Imaging (MPI) is a new tracer imaging modality that is gaining significant interest from NMR and MRI researchers. While the physics of MPI differ substantially from MRI, it employs hardware and imaging concepts that are familiar to MRI researchers, such as magnetic excitation and detection, pulse sequences, and relaxation effects. Furthermore, MPI employs the same superparamagnetic iron oxide (SPIO) contrast agents that are sometimes used for MR angiography and are often used for MRI cell tracking studies. These SPIOs are much safer for humans than iodine or gadolinium, especially for chronic kidney disease (CKD) patients. The weak kidneys of CKD patients cannot safely excrete iodine or gadolinium, leading to increased morbidity and mortality after iodinated X-ray or CT angiograms, or after gadolinium MRA studies. Iron oxides, on the other hand, are processed in the liver, and have been shown to be safe even for CKD patients. Unlike the “black blood” contrast generated by SPIOs in MRI due to increased T2* dephasing, SPIOs in MPI generate positive, “bright blood” contrast. With this ideal contrast, even prototype MPI scanners can already achieve fast, high-sensitivity, and high-contrast angiograms with millimeter-scale resolutions in phantoms and in animals. Moreover, MPI shows great potential for an exciting array of applications, including stem cell tracking in vivo, first-pass contrast studies to diagnose or stage cancer, and inflammation imaging in vivo. So far, only a handful of prototype small-animal MPI scanners have been constructed worldwide. Hence, MPI is open to great advances, especially in hardware, pulse sequence, and nanoparticle improvements, with the potential to revolutionize the biomedical imaging field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Regeneration of ischemic cardiac muscle and vascular endothelium by adult stem cells
Jackson, K. A., Majka, S. M., Wang, H., Pocius, J., Hartley, C. J., Majesky, M. W., Entman, M. L., Michael, L. H., Hirschi, K. K., & Goodell, M. A. (2001) · Journal of Clinical Investigation · doi:10.1172/jci12150 · Cited by 1,960
Kim, J.-H., Auerbach, J. M., Rodríguez-Gómez, J. A., Velasco, I., Gavin, D., Lumelsky, N., Lee, S.-H., Nguyen, J., Sánchez-Pernaute, R., Bankiewicz, K., et al. (2002) · Nature · doi:10.1038/nature00900 · Cited by 1,607
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Tissue-Penetrating Delivery of Compounds and Nanoparticles into Tumors
Sugahara, K. N., Teesalu, T., Karmali, P. P., Kotamraju, V. R., Agemy, L., Girard, O. M., Hanahan, D., Mattrey, R. F., & Ruoslahti, E. (2009) · Cancer Cell · doi:10.1016/j.ccr.2009.10.013 · Cited by 1,136
Contrast-Induced Acute Kidney Injury
McCullough, P. A., Choi, J. P., Feghali, G. A., Schussler, J. M., Stoler, R. M., Vallabahn, R. C., & Mehta, A. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.05.099 · Cited by 1,067
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,018
Magnetic relaxation switches capable of sensing molecular interactions
Perez, J. M., Josephson, L., O'Loughlin, T., Högemann, D., & Weissleder, R. (2002) · Nature Biotechnology · doi:10.1038/nbt720 · Cited by 889
Contrast-Induced Acute Kidney Injury
McCullough, P. A. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.12.035 · Cited by 822
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Xu, J., Kochanek, K. D., Murphy, S. L., & Tejada‐Vera, B. (2010) · PubMed · Cited by 650
Bone marrow–derived stem cells initiate pancreatic regeneration
Hess, D., Li, L., Martin, M., Sakano, S., Hill, D., Strutt, B., Thyssen, S., Gray, D. A., & Bhatia, M. (2003) · Nature Biotechnology · doi:10.1038/nbt841 · Cited by 614
Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI
Arbab, A. S., Yocum, G. T., Kalish, H., Jordan, E. K., Anderson, S. A., Khakoo, A. Y., Read, E. J., & Frank, J. A. (2004) · Blood · doi:10.1182/blood-2004-02-0655 · Cited by 529
Biomimetic amplification of nanoparticle homing to tumors
Simberg, D., Duza, T., Park, J. H., Essler, M., Pilch, J., Zhang, L., Derfus, A. M., Yang, M., Hoffman, R. M., Bhatia, S., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610298104 · Cited by 471
FDA report: Ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease
Lu, M., Cohen, M. H., Rieves, D., & Pazdur, R. (2010) · American Journal of Hematology · doi:10.1002/ajh.21656 · Cited by 443
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
Stem cell‐based cell therapy in neurological diseases: A review
Kim, S. U., & de Vellis, J. (2009) · Journal of Neuroscience Research · doi:10.1002/jnr.22054 · Cited by 426
Goodwill, P. W., & Conolly, S. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2052284 · Cited by 395
Self-citationTwieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
Signal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345
Collidge, T. A., Thomson, P. C., Mark, P. B., Traynor, J. P., Jardine, A. G., Morris, S. T. W., Simpson, K., & Roditi, G. H. (2007) · Radiology · doi:10.1148/radiol.2451070353 · Cited by 319
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Self-citationX‐Space MPI: Magnetic Nanoparticles for Safe Medical Imaging
Goodwill, P. W., Saritas, E. U., Croft, L. R., Kim, T. N., Krishnan, K. M., Schaffer, D. V., & Conolly, S. M. (2012) · Advanced Materials · doi:10.1002/adma.201200221 · Cited by 301
Self-citationA simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
Broome, D. R. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.02.011 · Cited by 283
Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years
Ferrucci, J. T., & Stark, D. D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120963 · Cited by 279 · cited 1×
“SPIO contrast agents are processed in the liver rather than the kidneys [19,20], and have been shown to be safe for CKD patients [21].”
Targeting atherosclerosis by using modular, multifunctional micelles
Peters, D., Kastantin, M., Kotamraju, V. R., Karmali, P. P., Gujraty, K., Tirrell, M., & Ruoslahti, E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903369106 · Cited by 271
In Vivo Tracking of Stem Cells for Clinical Trials in Cardiovascular Disease
Frangioni, J. V., & Hajjar, R. J. (2004) · Circulation · doi:10.1161/01.cir.0000149840.46523.fc · Cited by 269
Neuwelt, E. A., Hamilton, B. E., Varallyay, C. G., Rooney, W. R., Edelman, R. D., Jacobs, P. M., & Watnick, S. G. (2009) · Kidney International · doi:10.1038/ki.2008.496 · Cited by 267
A simulation study on the resolution and sensitivity of magnetic particle imaging
Weizenecker, J., Borgert, J., & Gleich, B. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/001 · Cited by 267
MEDICAL MAGNETIC RESONANCE (MR) PROCEDURES: PROTECTION OF PATIENTS
(2004) · Health Physics · doi:10.1097/00004032-200408000-00008 · Cited by 243
Reddan, D. N., Szczech, L. A., Tuttle, R. H., Shaw, L. K., Jones, R. H., Schwab, S. J., Smith, M. S., Califf, R. M., Mark, D. B., & Owen, W. F. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000083900.92829.f5 · Cited by 242
LaConte, L., Nitin, N., & Bao, G. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00893-x · Cited by 229
Contrast-induced nephrotoxicity: Clinical landscape
Katzberg, R. W., & Haller, C. (2006) · Kidney International · doi:10.1038/sj.ki.5000366 · Cited by 224
Optimization of nanoparticle core size for magnetic particle imaging
Ferguson, R. M., Minard, K. R., & Krishnan, K. M. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.083 · Cited by 222
Neuwelt, E. A., Várallyay, P., Bagó, A. G., Muldoon, L. L., Nesbit, G., & Nixon, R. (2004) · Neuropathology and Applied Neurobiology · doi:10.1111/j.1365-2990.2004.00557.x · Cited by 219
Magnetic nanoparticle temperature estimation
Weaver, J. B., Rauwerdink, A. M., & Hansen, E. W. (2009) · Medical Physics · doi:10.1118/1.3106342 · Cited by 209
Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles
Schmitz, S. A., Taupitz, M., Wagner, S., Wolf, K., Beyersdorff, D., & Hamm, B. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1194 · Cited by 208
Projection X-Space Magnetic Particle Imaging
Goodwill, P. W., Konkle, J. J., Zheng, B., Saritas, E. U., & Conolly, S. T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2185247 · Cited by 185
Self-citationGoldfarb, S., McCullough, P. A., McDermott, J., & Gay, S. B. (2009) · Mayo Clinic Proceedings · doi:10.4065/84.2.170 · Cited by 183
Ix, J. H., Mercado, N., Shlipak, M. G., Lemos, P. A., Boersma, E., Lindeboom, W., O'Neill, W. W., Wijns, W., & Serruys, P. W. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.10.010 · Cited by 182
Ferromagnetic particles as contrast agents for magnetic resonance imaging of liver and spleen
Dias, M. H. M., & Lauterbur, P. C. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030218 · Cited by 180
MR angiography by selective inversion recovery
Nishimura, D. G., Macovski, A., Pauly, J. M., & Conolly, S. M. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040214 · Cited by 171
Self-citationAnalysis of a 3-D System Function Measured for Magnetic Particle Imaging
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188639 · Cited by 171
Magnetic particle imaging using a field free line
Weizenecker, J., Gleich, B., & Borgert, J. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/10/105009 · Cited by 170
Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging
Ferguson, R. M., Minard, K. R., Khandhar, A. P., & Krishnan, K. M. (2011) · Medical Physics · doi:10.1118/1.3554646 · Cited by 162
Macromolecular MRI contrast agents for imaging tumor angiogenesis
Barrett, T., Kobayashi, H., Brechbiel, M. W., & Choyke, P. L. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.025 · Cited by 150
Várallyay, P., Nesbit, G. M., Muldoon, L. L., Nixon, R. R., Delashaw, J. B., Cohen, J. I., Petrillo, A., Rink, D., & Neuwelt, E. A. (2002) · PubMed Central · Cited by 149
Relaxation in X-Space Magnetic Particle Imaging
Croft, L. R., Goodwill, P. W., & Conolly, S. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2217979 · Cited by 143
Self-citationNarrowband Magnetic Particle Imaging
Goodwill, P. W., Scott, G., Stang, P. P., & Conolly, S. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013849 · Cited by 137
Self-citationInflammation Imaging in Atherosclerosis
Rudd, J. H. F., Hyafil, F., & Fayad, Z. A. (2009) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.108.165563 · Cited by 130
An x-space magnetic particle imaging scanner
Goodwill, P. W., Lu, K., Zheng, B., & Conolly, S. (2012) · Review of Scientific Instruments · doi:10.1063/1.3694534 · Cited by 128
Self-citationJohansson, L. O., Bjørnerud, A., Ahlstrom, H. K., Ladd, D. L., & Fujii, D. K. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1086 · Cited by 112
Knopp, T., Biederer, S., Sattel, T. F., Erbe, M., & Buzug, T. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2113188 · Cited by 105
Orringer, D. A., Koo, Y., Chen, T., Kopelman, R., Sagher, O., & Philbert, M. A. (2009) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2008.296 · Cited by 103
Imaging Inflammation in Acute Brain Ischemia
Jander, S., Schroeter, M., & Saleh, A. (2007) · Stroke · doi:10.1161/01.str.0000250048.42916.ad · Cited by 101
Measurement of molecular binding using the Brownian motion of magnetic nanoparticle probes
Rauwerdink, A. M., & Weaver, J. B. (2010) · Applied Physics Letters · doi:10.1063/1.3291063 · Cited by 97
Ferrohydrodynamic relaxometry for magnetic particle imaging
Goodwill, P. W., Tamrazian, A., Croft, L. R., Lu, C.-N., Johnson, E., Pidaparthi, R., Ferguson, R. M., Khandhar, A. P., Krishnan, K. M., & Conolly, S. (2011) · Applied Physics Letters · doi:10.1063/1.3604009 · Cited by 91
Self-citationThree‐dimensional flow‐independent peripheral angiography
Brittain, J. H., Olcott, E. W., Szuba, A., Gold, G. E., Wright, G. A., Pablo Irarrázaval, M., & Nishimura, D. G. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380302 · Cited by 90
Rudnick, M. R., Goldfarb, S., & Tumlin, J. A. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04951107 · Cited by 84
Weinberg, I. N., Stepanov, P. Y., Fricke, S. T., Probst, R., Urdaneta, M., Warnow, D. M., Sanders, H. D., Glidden, S. C., McMillan, A. B., Starewicz, P. M., et al. (2012) · Medical Physics · doi:10.1118/1.3702775 · Cited by 55
Field-free line formation in a magnetic field
Knopp, T., Sattel, T. F., Biederer, S., & Buzug, T. M. (2009) · Journal of Physics A Mathematical and Theoretical · doi:10.1088/1751-8113/43/1/012002 · Cited by 48
Erbe, M., Knopp, T., Sattel, T. F., Biederer, S., & Buzug, T. M. (2011) · Medical Physics · doi:10.1118/1.3626481 · Cited by 39
Generation of a static magnetic field-free line using two Maxwell coil pairs
Knopp, T., Erbe, M., Sattel, T. F., Biederer, S., & Buzug, T. M. (2010) · Applied Physics Letters · doi:10.1063/1.3486118 · Cited by 30
Safety Limits for Human-Size Magnetic Particle Imaging Systems
Sarıtaş, E. Ü., Goodwill, P. W., Zhang, G. Z., Yu, W., & Conolly, S. (2012) · Springer proceedings in physics · doi:10.1007/978-3-642-24133-8_52 · Cited by 18
Self-citationThird Generation X-Space MPI Mouse and Rat Scanner
Goodwill, P. W., Croft, L., Konkle, J., Lu, K., Sarıtaş, E. Ü., Zheng, B., & Conolly, S. (2012) · Springer proceedings in physics · doi:10.1007/978-3-642-24133-8_42 · Cited by 11
Self-citationExperimental 3D X-Space Magnetic Particle Imaging Using Projection Reconstruction
Konkle, J., Goodwill, P. W., Carrasco‐Zevallos, O. M., & Conolly, S. (2012) · Springer proceedings in physics · doi:10.1007/978-3-642-24133-8_39 · Cited by 5
Self-citation
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Yu, E. Y., Bishop, M., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04865 · Cited by 366
Self-citationRezaei, B., Yari, P., Sanders, S. M., Wang, H., Chugh, V. K., Liang, S., Mostufa, S., Xu, K., Wang, J., Gómez‐Pastora, J., et al. (2024) · Small · doi:10.1002/smll.202304848 · Cited by 366
Metadata
- Authors
- Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-04
- Volume
- 229
- Pages
- 116-126
- ISSN
- 1090-7807 (ISSN-L)
- OpenAlex
- W2039708097
- Cited by
- 307
- References
- 70
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.