Automated Early Detection of Diabetic Retinopathy
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Purpose To compare the performance of automated diabetic retinopathy (DR) detection, using the algorithm that won the 2009 Retinopathy Online Challenge Competition in 2009, (‘Challenge2009’) against that of the one currently used in EyeCheck, a large computer-aided early DR detection project. Design Evaluation of diagnostic test or technology. Participants Fundus photographic sets, consisting of two fundus images from each eye, were evaluated from 16,670 patient visits of 16,670 people with diabetes who had not previously been diagnosed with DR. Methods The fundus photographic set from each visit was analyzed by a single retinal expert; 793 of the 16,770 sets were classified as containing more than minimal DR (threshold for referral). The outcomes of the two algorithmic detectors were applied separately to the dataset and compared by standard statistical measures. Main Outcome Measures The area under the Receiver Operating Characteristic curve (AUC), a measure of the sensitivity and specificity of DR detection. Results Agreement was high, and exams containing more than minimal DR were detected with an AUC of 0.839 by the ‘Eyecheck’ algorithm and an AUC of 0.821 for ‘Challenge2009’, a statistically non-significant difference (z-score 1.91). If either of the algorithms detected DR in combination, AUC for detection was 0.86, the same as the theoretically expected maximum. At 90% sensitivity, the specificity of the ‘EyeCheck’ algorithm was 47.7% and the ‘Challenge2009’ algorithm, 43.6%. Conclusions DR detection algorithms appear to be maturing, and further improvements in detection performance cannot be differentiated from best clinical practices, because the performance of competitive algorithm development has now reached the human intra-reader variability limit. Additional validation studies on larger, well-defined, but more diverse populations of patients with diabetes are urgently needed, anticipating cost-effective early detection of DR in millions of people with diabetes to triage those patients who need further care at a time when they have early rather than advanced DR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Self-citationThe Continuing Epidemics of Obesity and Diabetes in the United States
Mokdad, A. H. (2001) · JAMA · doi:10.1001/jama.286.10.1195 · Cited by 2,730
Early Photocoagulation for Diabetic Retinopathy
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38011-7 · Cited by 1,259
Walter, T., Klein, J., Massin, P., & Erginay, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806290 · Cited by 825
Fundus Photographic Risk Factors for Progression of Diabetic Retinopathy
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38014-2 · Cited by 814
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Self-citationAutomatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Self-citationEconomic And Demographic Trends Signal An Impending Physician Shortage
Cooper, R. A., Getzen, T. E., McKee, H. J., & Laud, P. (2002) · Health Affairs · doi:10.1377/hlthaff.21.1.140 · Cited by 477
Niemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Self-citationOptimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs
Quellec, G., Lamard, M., Josselin, P. M., Cazuguel, G., Cochener, B., & Roux, C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.920619 · Cited by 343
Self-citationLin, D. Y., Blumenkranz, M. S., Brothers, R. J., & Grosvenor, D. M. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01522-2 · Cited by 327
Spencer, T., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0021 · Cited by 305
Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Self-citationAn economic analysis of interventions for diabetes.
Klonoff, D. C., & Schwartz, D. M. (2000) · Diabetes Care · doi:10.2337/diacare.23.3.390 · Cited by 267
Philip, S., Fleming, A. D., Goatman, K. A., Fonseca, S., Mcnamee, P., Scotland, G. S., Prescott, G. J., Sharp, P. F., & Olson, J. A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.119453 · Cited by 225
Segmentation of the Optic Disc, Macula and Vascular Arch in Fundus Photographs
Niemeijer, M., Abramoff, M. D., & van Ginneken, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.885336 · Cited by 220
Self-citationFrame, A. J., Undrill, P. E., Cree, M. J., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (1998) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(98)00011-0 · Cited by 215
Teng, T., Lefley, M., & Claremont, D. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347689 · Cited by 179
Hipwell, J. H., Strachan, F., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00338.x · Cited by 177
Olson, J. A., Strachan, F. M., Hipwell, J. H., Goatman, K. A., McHardy, K. C., Forrester, J. V., & Sharp, P. F. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.00969.x · Cited by 164
Bresnick, G. H., Mukamel, D. B., Dickinson, J. C., & Cole, D. R. (2000) · Ophthalmology · doi:10.1016/s0161-6420(99)00010-x · Cited by 163
Automated Detection of Fundus Photographic Red Lesions in Diabetic Retinopathy
Larsen, M., Godt, J., Larsen, N., Lund-Andersen, H., Sjølie, A. K., Agardh, E., Kalm, H., Grunkin, M., & Owens, D. R. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0418 · Cited by 150
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.09.006 · Cited by 146
Self-citationWeb-Based Screening for Diabetic Retinopathy in a Primary Care Population: The EyeCheck Project
Abramoff, M. D., & Suttorp-Schulten, M. S. A. (2005) · Telemedicine and e-Health · doi:10.1089/tmj.2005.11.668 · Cited by 125
Information Fusion for Diabetic Retinopathy CAD in Digital Color Fundus Photographs
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012029 · Cited by 125
Self-citationAutomated Detection of Diabetic Retinopathy in a Fundus Photographic Screening Population
Larsen, N., Godt, J., Grunkin, M., Lund-Andersen, H., & Larsen, M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0417 · Cited by 110
Scotland, G. S., McNamee, P., Philip, S., Fleming, A. D., Goatman, K. A., Prescott, G. J., Fonseca, S., Sharp, P. F., & Olson, J. A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.120972 · Cited by 107
Ophthalmoscopy versus fundus photographs for detecting and grading diabetic retinopathy.
Kinyoun, J. L., Martin, D., Fujimoto, W. Y., & Leonetti, D. L. (1992) · PubMed · Cited by 99
Lymphomas involving the eye and the ocular adnexa
Coupland, S. E., & Damato, B. E. (2006) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e328010948d · Cited by 96
Analysis of Correlated ROC Areas in Diagnostic Testing
Song, H. H. (1997) · Biometrics · doi:10.2307/2533123 · Cited by 83
Automatic classification of retinal vessels into arteries and veins
Niemeijer, M., van Ginneken, B., & Abràmoff, M. D. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.813826 · Cited by 70
Self-citationRuamviboonsuk, P., Teerasuwanajak, K., Tiensuwan, M., & Yuttitham, K. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.11.021 · Cited by 69
Abràmoff, M. D., & Niemeijer, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259622 · Cited by 67
Self-citationLee, P. P. (2007) · Archives of Ophthalmology · doi:10.1001/archopht.125.3.406 · Cited by 57
Hagen, M. D. (1995) · Primary Care Clinics in Office Practice · doi:10.1016/s0095-4543(21)00513-3 · Cited by 39
Early detection of AD using cortical thickness measurements
Spjuth, M., Gravesen, F. H., Eskildsen, S. F., & Østergaard, L. R. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.709806 · Cited by 27
Cited by
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Self-citationArtificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Metadata
- Authors
- Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 117
- Issue
- 6
- Pages
- 1147-1154
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2060968434
- Cited by
- 287
- References
- 40
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.