The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Retinal Prostheses: Current Clinical Results and Future Needs
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Self-citationAhuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Self-citationWhat blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179
Deep Brain Stimulation Devices: A Brief Technical History and Review
Coffey, R. J. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2008.00620.x · Cited by 178
MORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158
Self-citationSommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
Cited by
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya-Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Di Paolo, M., Di Marco, S., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 290
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Morphologic studies in severe human RP patients reveal moderate preservation of inner retinal neurons: 70e80% of the bipolar cells and 25e40% of the ganglion cells (Humayun et al., 1999b; Santos et al., 1997; Weiland et al., 2011).”
Self-citationDeveloping a hippocampal neural prosthetic to facilitate human memory encoding and recall
Hampson, R. E., Song, D., Robinson, B. S., Fetterhoff, D., Dakos, A. S., Roeder, B. M., She, X., Wicks, R. T., Witcher, M. R., Couture, D. E., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaaed7 · Cited by 224
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
‘Visual’ Acuity of the Congenitally Blind Using Visual-to-Auditory Sensory Substitution
Striem-Amit, E., Guendelman, M., & Amedi, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033136 · Cited by 117
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
“Indeed, clinical trials with prototype epiretinal prostheses have shown that electrical stimulation based on signals from an external camera can induce artificial visual percepts and allow patients to perform simple visual tasks (for review, see Weiland et al., 2011).”
BackgroundActivation of ganglion cells and axon bundles using epiretinal electrical stimulation
Grosberg, L. E., Ganesan, K., Goetz, G. A., Madugula, S. S., Bhaskhar, N., Fan, V., Li, P., Hottowy, P., Dabrowski, W., Sher, A., et al. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00750.2016 · Cited by 70
The response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38
“In recent years, there have been several significant advancements towards the goal of restoring vision in blind patients using retinal prosthetics [1–5] (for review, see [6]).”
BackgroundHigh-Fidelity Reproduction of Visual Signals by Electrical Stimulation in the Central Primate Retina
Gogliettino, A. R., Madugula, S. S., Grosberg, L. E., Vilkhu, R. S., Brown, J., Nguyen, H., Kling, A., Hottowy, P., Dąbrowski, W., Sher, A., et al. (2023) · The Journal of Neuroscience · doi:10.1523/jneurosci.1091-22.2023 · Cited by 30
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35
Focal electrical stimulation of human retinal ganglion cells for vision restoration
Madugula, S. S., Gogliettino, A. R., Zaidi, M., Aggarwal, G., Kling, A., Shah, N. P., Brown, J. B., Vilkhu, R., Hays, M. R., Nguyen, H., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/aca5b5 · Cited by 26
High-fidelity reproduction of visual signals by electrical stimulation in the central primate retina
Gogliettino, A. R., Madugula, S. S., Grosberg, L. E., Vilkhu, R. S., Brown, J., Nguyen, H., Kling, A., Hottowy, P., Dąbrowski, W., Sher, A., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.05.24.493162 · Cited by 30
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3913 · Cited by 24
Esler, T. B., Kerr, R. R., Tahayori, B., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193598 · Cited by 28
Chapter 1—restoring vision to the blind: the new age of implanted visual prostheses
(2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.7.3 · Cited by 21
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Buchs, G., Maidenbaum, S., Levy-Tzedek, S., & Amedi, A. (2015) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-150592 · Cited by 8
Metadata
- Authors
- Weiland, J. D., Cho, A. K., & Humayun, M. S.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 118
- Issue
- 11
- Pages
- 2227-2237
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2150813291
- Cited by
- 199
- References
- 12
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.