Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Pulse oximetry has revolutionized the ability to monitor oxygenation in a continuous, accurate, and non-invasive fashion. Despite its ubiquitous use, it is our impression and supported by studies that many providers do not know the basic principles behind its mechanism of function. This knowledge is important because it provides the conceptual basis of appreciating its limitations and recognizing when pulse oximeter readings may be erroneous. In this review, we discuss how pulse oximeters are able to distinguish oxygenated hemoglobin from deoxygenated hemoglobin and how they are able to recognize oxygen saturation only from the arterial compartment of blood. Based on these principles, we discuss the various conditions that can cause spurious readings and the mechanisms underlying them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zijlstra, W. G., Buursma, A., & Meeuwsen-van der Roest, W. P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1633 · Cited by 665
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Pulmonary Complications of Sickle Cell Disease
Gladwin, M. T., & Vichinsky, E. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0804411 · Cited by 470 · cited 1×
“Complications of sickle cell disease, such as vasoocclusive crisis and acute chest syndrome, are often precipitated or exacerbated by hypoxemia, and can result in a vicious cycle of additional sickling and vasoocclusive crises.(11) Thus, accurate detection of hypoxemia in these patients plays an important role in miti…”
BackgroundTremper, K. K., & Barker, S. J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00019 · Cited by 435
Clinical Problem Solving: Assessment of Phonological Disorders
Miccio, A. W. (2002) · American Journal of Speech-Language Pathology · doi:10.1044/1058-0360(2002/023 · Cited by 313
The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Barker, S. J., & Tremper, K. K. (1987) · Anesthesiology · doi:10.1097/00000542-198705000-00014 · Cited by 281
Kelleher, J. F. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01618369 · Cited by 202
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Effects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
Schnapp, L. M., & Cohen, N. H. (1990) · Chest · doi:10.1378/chest.98.5.1244 · Cited by 193
Cited by
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
Ultraflexible Near‐Infrared Organic Photodetectors for Conformal Photoplethysmogram Sensors
Park, S., Fukuda, K., Wang, M., Lee, C., Yokota, T., Jin, H., Jinno, H., Kimura, H., Zalar, P., Matsuhisa, N., et al. (2018) · Advanced Materials · doi:10.1002/adma.201802359 · Cited by 275
Fetal pulse oximetry for fetal assessment in labour
East, C. E., Begg, L., Colditz, P. B., & Lau, R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004075.pub4 · Cited by 211
Gottlieb, E. R., Ziegler, J., Morley, K., Rush, B., & Celi, L. A. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.2587 · Cited by 134
Racial discrepancy in pulse oximeter accuracy in preterm infants
Vesoulis, Z., Tims, A., Lodhi, H., Lalos, N., & Whitehead, H. (2022) · Journal of Perinatology · doi:10.1038/s41372-021-01230-3 · Cited by 120
Chatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
“, A(λ) = ∆A(λ)/Adiastolic(λ)), were used to quantify the absorbance modulation ratio of RM [49]: RM = A(red) A(IR) .”
MethodSpaccarotella, C., Polimeni, A., Mancuso, C., Pelaia, G., Esposito, G., & Indolfi, C. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11061467 · Cited by 65
“The major advantage of this method is that it is non-invasive and has other benefits such as ease of use so that it can be used for multiple out-of-hospital measurements [1].”
BackgroundNon-Contact SpO2 Prediction System Based on a Digital Camera
Al-Naji, A., Khalid, G. A., Mahdi, J. F., & Chahl, J. (2021) · Applied Sciences · doi:10.3390/app11094255 · Cited by 61
Critical Bias in Critical Care Devices
Charpignon, M.-L., Byers, J., Cabral, S., Celi, L. A., Fernandes, C., Gallifant, J., Lough, M. E., Mlombwa, D., Moukheiber, L., Ong, B. A., et al. (2023) · Critical Care Clinics · doi:10.1016/j.ccc.2023.02.005 · Cited by 35
Vahlsing, T., Delbeck, S., Leonhardt, S., & Heise, H. M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818798347 · Cited by 28
Perfusion Changes at the Forehead Measured by Photoplethysmography during a Head-Down Tilt Protocol
Ysehak Abay, T., Shafqat, K., & Kyriacou, P. A. (2019) · Biosensors · doi:10.3390/bios9020071 · Cited by 22
The Big Consequences of Small Discrepancies: Why Racial Differences in Pulse Oximetry Errors Matter
Holder, A. L., & Wong, A.-K. I. (2022) · Critical Care Medicine · doi:10.1097/ccm.0000000000005447 · Cited by 13
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12
“A PO evaluates absorbance with time, a first-order derivative of the above equation concerning time [2]: The ratio R of light transmitted to incident light from the red and IR wavelengths of the light source is expressed as From the R-value extinction coefficient of haemoglobin, SaO 2 can be…”
BackgroundMethodInfluentialZhou, L., Aljiffry, A., Lee, Y. J., Matthews, J., Seitter, B., Soltis, I., Huang, Y., Maher, K., & Yeo, W.-H. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117372 · Cited by 9
Wearable Physiological Stress Monitoring System—A Proof-of-Concept Study
Ong, S. W., Sundar, R., Bandla, A., & Kim, N. (2021) · IRC-SET 2020 · doi:10.1007/978-981-15-9472-4_54 · Cited by 4
Soft, all-in-one, nanomembrane wearable system for advancing neonatal health monitoring in Ethiopia
Zhou, L., Joseph, M., Lee, Y. J., Yadav, D., Nayak, L., Woodall, J., Matthews, J., Soltis, I., Mekuria, F. M., Yeshanew, K. H., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01974-8 · Cited by 3
“The resulting ratio is paired with an experimentally derived calibration curve to estimate SpO2 15 – 18 .”
Influential
Metadata
- Authors
- Chan, E. D., Chan, M. M., & Chan, M. M.
- Venue
- Respiratory Medicine
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 107
- Issue
- 6
- Pages
- 789-799
- ISSN
- 0954-6111 (ISSN-L)
- OpenAlex
- W2071229756
- Cited by
- 710
- References
- 43
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.