Wearable hydrogel patch with noninvasive, electrochemical glucose sensor for natural sweat detection
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Recent advances in microelectronics and electrochemical sensing platforms have preceded the development of devices for personal monitoring and managing physiological and metabolic information that exploit sweat as a noninvasive, convenient approach for providing information about underlying health conditions, such as glucose level monitoring. Although most sweat glucose sensors have targeted applications during exercise and other active stimulation induced-sweat, natural sweating offers an attractive alternative with minimal effect on users that can be accessed during routine and sedentary activities without impeding personal lifestyle and preserves the correlation between blood and sweat glucose. Here, we present a noninvasive sweat glucose sensor with convenient hydrogel patches for rapid sampling of natural perspiration without external activities that stimulate sweating. The wearable hydrogel patch rapidly takes up natural sweat from the hand and serves as a medium for electrochemical sensing. A prussian blue-doped poly(3,4-ethylenedioxythiophene nanocomposite (PB-PEDOT NC) electrode provides cost-effective, stable and excellent electrocatalytic activity in sweat glucose measurements. We demonstrated sweat glucose sensor functionality by long-term measurements of glucose in sweat from human subjects consuming food and drinks. By enabling the analysis of sweat glucose during routine and sedentary activities, the sweat glucose sensor shows great promise for clinical-grade glucose management and enlarges the scope of next-generation noninvasive sensing systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Mitochondrial dysfunction and type 2 diabetes
Lowell, B. B., & Shulman, G. I. (2005) · Science · doi:10.1126/science.1104343 · Cited by 2,070
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
Skin-Attachable, Stretchable Electrochemical Sweat Sensor for Glucose and pH Detection
Oh, S. Y., Hong, S. Y., Jeong, Y. R., Yun, J., Park, H., Jin, S. W., Lee, G., Oh, J. H., Lee, H., Lee, S.-S., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03342 · Cited by 440
A wearable patch for continuous analysis of thermoregulatory sweat at rest
Nyein, H. Y. Y., Bariya, M., Tran, B., Ahn, C. H., Brown, B. J., Ji, W., Davis, N., & Javey, A. (2021) · Nature Communications · doi:10.1038/s41467-021-22109-z · Cited by 437
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Ricci, F., Amine, A., Palleschi, G., & Moscone, D. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00169-0 · Cited by 349
Wang, Y., Zhao, C., Wang, J., Luo, X., Xie, L., Zhan, S., Kim, J., Wang, X., Liu, X., & Ying, Y. (2021) · Science Advances · doi:10.1126/sciadv.abe4553 · Cited by 340
Eyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Antifouling strategies in advanced electrochemical sensors and biosensors
Lin, P.-H., & Li, B. (2019) · The Analyst · doi:10.1039/c9an02017a · Cited by 295
Self-citationNon‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Zhang, Y., Guo, H., Kim, S. B., Wu, Y., Ostojich, D., Park, S. H., Wang, X., Weng, Z., Li, R., Bandodkar, A. J., et al. (2019) · Lab on a Chip · doi:10.1039/c9lc00103d · Cited by 250
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Wang, R., Zhai, Q., An, T., Gong, S., & Cheng, W. (2021) · Talanta · doi:10.1016/j.talanta.2020.121484 · Cited by 193
A paper strip based non-invasive glucose biosensor for salivary analysis
Soni, A., & Jha, S. K. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.042 · Cited by 173
Zhang, Z., Chen, Z., Cheng, F., Zhang, Y., & Chen, L. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.090 · Cited by 169
Glove-based sensors for multimodal monitoring of natural sweat
Bariya, M., Li, L., Ghattamaneni, R., Ahn, C. H., Nyein, H. Y. Y., Tai, L.-C., & Javey, A. (2020) · Science Advances · doi:10.1126/sciadv.abb8308 · Cited by 154
Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01727 · Cited by 114
Body-Interfaced Chemical Sensors for Noninvasive Monitoring and Analysis of Biofluids
Zhao, J., Guo, H., Li, J., Bandodkar, A. J., & Rogers, J. A. (2019) · Trends in Chemistry · doi:10.1016/j.trechm.2019.07.001 · Cited by 95
Detection of low glucose levels in sweat with colorimetric wearable biosensors
Vaquer, A., Barón, E., & de la Rica, R. (2021) · The Analyst · doi:10.1039/d1an00283j · Cited by 89
Agustini, D., Bergamini, M. F., & Junior, L. H. M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.035 · Cited by 86
Co3O4 needles on Au honeycomb as a non-invasive electrochemical biosensor for glucose in saliva
Coyle, V. E., Kandjani, A. E., Field, M. R., Hartley, P. G., Chen, M., Sabri, Y. M., & Bhargava, S. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111479 · Cited by 84
Sweat Secretion from Palmar and Dorsal Surfaces of the Hands During Passive and Active Heating
Machado-Moreira, C. A., Caldwell, J. N., Mekjavic, I. B., & Taylor, N. A. S. (2008) · Aviation, Space, and Environmental Medicine · doi:10.3357/asem.2354.2008 · Cited by 54
Wang, J., Wang, Y., Cui, M., Xu, S., & Luo, X. (2016) · Microchimica Acta · doi:10.1007/s00604-016-2025-y · Cited by 44
Hooton, K., & Li, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01988 · Cited by 43
Electrochemical monitoring of alcohol in sweat
Biscay, J., Findlay, E., & Dennany, L. (2020) · Talanta · doi:10.1016/j.talanta.2020.121815 · Cited by 39
Comparison of Glucose Levels in Capillary Blood Samples Obtained from a Variety of Body Sites
Peled, N., Wong, D., & Gwalani, S. L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/15209150252924067 · Cited by 35
Souza, S. L., Graça, G., & Oliva, A. (2018) · Skin Research and Technology · doi:10.1111/srt.12412 · Cited by 34
In situ electrochemical preparation and characterization of PEDOT–Prussian blue composite materials
Lupu, S. (2011) · Synthetic Metals · doi:10.1016/j.synthmet.2010.12.015 · Cited by 28
Lin, P.-H., Chang, W.-L., Sheu, S.-C., & Li, B. (2020) · iScience · doi:10.1016/j.isci.2020.101658 · Cited by 24
Self-citationHsieh, Y.-L., Chen, C.-W., Lin, W.-H., & Li, B. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00249 · Cited by 10
Self-citation
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Li, Q.-F., Chen, X., Wang, H., Liu, M., & Peng, H.-L. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c20543 · Cited by 255
Metadata
- Authors
- Lin, P.-H., Sheu, S.-C., Chen, C.-W., Huang, S.-C., & Li, B.-R.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 241
- Pages
- 123187
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W4205429484
- Cited by
- 232
- References
- 42
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.