Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Abstract
The ability to determine trabecular bone tissue elastic and failure properties has biological and clinical importance. To date, trabecular tissue yield strains remain unknown due to experimental difficulties, and elastic moduli studies have reported controversial results. We hypothesized that the elastic and tensile and compressive yield properties of trabecular tissue are similar to those of cortical tissue. Effective tissue modulus and yield strains were calibrated for cadaveric human femoral neck specimens taken from 11 donors, using a combination of apparent-level mechanical testing and specimen-specific, high-resolution, nonlinear finite element modeling. The trabecular tissue properties were then compared to measured elastic modulus and tensile yield strain of human femoral diaphyseal cortical bone specimens obtained from a similar cohort of 34 donors. Cortical tissue properties were obtained by statistically eliminating the effects of vascular porosity. Results indicated that mean elastic modulus was 10% lower (p<0.05) for the trabecular tissue (18.0+/-2.8 GPa) than for the cortical tissue (19.9+/-1.8 GPa), and the 0.2% offset tensile yield strain was 15% lower for the trabecular tissue (0.62+/-0.04% vs. 0.73+/-0.05%, p<0.001). The tensile-compressive yield strength asymmetry for the trabecular tissue, 0.62 on average, was similar to values reported in the literature for cortical bone. We conclude that while the elastic modulus and yield strains for trabecular tissue are just slightly lower than those of cortical tissue, because of the cumulative effect of these differences, tissue strength is about 25% greater for cortical bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [142]
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,456
Zysset, P. K., Guo, X.-D. E., Hoffler, C. E., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,001
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationAging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Cited by
Sorted by citations
Items 201–300 of 1,000
Multiscale investigation of the functional properties of the human femur
Cristofolini, L., Taddei, F., Baleani, M., Baruffaldi, F., Stea, S., & Viceconti, M. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0077 · Cited by 49
“Subsequently, the sensitivity of the model to the uncertainties in modelling the geometry and the material properties of a human femur from the CT data needs to be assessed (Keyak et al. 1993; Lengsfeld et al. 1998; Bayraktar et al. 2004; Taddei et al. 2006a).”
BackgroundMethodShah, S. S., Gentile, J. M., Chen, X., et al. (2020) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2020.04.004 · Cited by 49
A bone remodelling model including the directional activity of BMUs
Martínez‐Reina, J., García‐Aznar, J. M., Domínguez, J., & Doblaré, M. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0122-5 · Cited by 49
“The results were compared with the mechanical properties obtained experimentally by other authors ( Bayraktar et al. 2004; Zysset et al. 1999; Bensamoun et al. 2004; Taylor et al. 2002).”
MethodResultInfluentialAldieri, A., Curreli, C., Szyszko, J. A., Mattina, A. A. L., & Viceconti, M. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107727 · Cited by 49
Christen, D., Melton, L. J., Zwahlen, A., Amin, S., Khosla, S., & Müller, R. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1996 · Cited by 47
“75% was assumed,((20)) and the hardening modulus was set to the elastic modulus of collagen (H1⁄4 2MPa).”
BackgroundJian, Y.-T., Yang, Y., Tian, T., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0128138 · Cited by 48
Hambli, R., & Thurner, P. J. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.07.005 · Cited by 48
Arias-Moreno, A. J., Hosseini, S. H., Bevers, M. S. A. M., et al. (2019) · Osteoporosis International · doi:10.1007/s00198-019-04935-6 · Cited by 48
Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.04.014 · Cited by 47
Multiscale modelling of the skeleton for the prediction of the risk of fracture
Viceconti, M., Taddei, F., Jan, S. V. S., Leardini, A., Cristofolini, L., Stea, S., Baruffaldi, F., & Baleani, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.01.009 · Cited by 47
Derikx, L. C., Vis, R., Meinders, T., Verdonschot, N. J. J., & Tanck, E. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.542463 · Cited by 46
Grassi, L., Väänänen, S. P., Ristinmaa, M., Jurvelin, J. S., & Isaksson, H. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0866-2 · Cited by 46
“2003) and yield limit values (Bayraktar et al. 2004) used in this model].”
BackgroundMethodInfluentialAsgari, M., Abi‐Rafeh, J., Hendy, G. N., et al. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.01.024 · Cited by 46
Costa, M. C., Éltes, P. E., Lazáry, Á., Varga, P. P., Viceconti, M., & Dall’Ara, E. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.06.027 · Cited by 47
“Bone plasticity was modelled using an isotropic Von Mises yield criterion, based on a density-strength relationship [Eq (3)] (Morgan and Keaveny, 2001), and including an isotropic hardening rule, with a 95% reduction in the post-yield modulus [Eq (4)] (Morgan et al., 2003; Bayraktar et al., 2004; Morgan and Keaveny, 2…”
MethodRemache, D., Semaan, M., Rossi, J.-M., Pithioux, M., & Milan, J. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103426 · Cited by 46
“12] GPa, reported in the literature [2, 5, 17].”
MethodPreclinical testing of drug delivery systems to bone
van Griensven, M. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.07.006 · Cited by 45
Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Ferguson, S. J., Cripton, P. A., & Helgason, B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.042 · Cited by 45
Nanoindentation of the insertional zones of human meniscal attachments into underlying bone
Hauch, K., Oyen, M. L., Odegard, G. M., & Donahue, T. L. H. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.10.005 · Cited by 45
Bhattacharya, P., Altai, Z., Qasim, M., & Viceconti, M. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1081-0 · Cited by 49
Moon, J. K., Lee, J. I., Hwang, K. T., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-11914-1 · Cited by 45
Imbert, L., Aurégan, J.-C., Pernelle, K., et al. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.12.020 · Cited by 45
“The yield and ultimate stresses are strongly sensitive to these two types of loading (Bayraktar et al., 2004).”
Shi, X., Sherry Liu, X., Wang, X., Edward Guo, X., & Niebur, G. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.05.032 · Cited by 45
“, 2000), and the strain limits in the tissue level constitutive model are consistent with the yield limits measured in cortical bone tissue (Bayraktar et al., 2004; Reilly and Burstein, 1975).”
BackgroundResultInfluentialSelf-citationMarcián, P., Borák, L., Zikmund, T., et al. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104393 · Cited by 44
Gong, H., Zhang, M., Fan, Y., Kwok, W. L., & Leung, P. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0514-7 · Cited by 44
Lin, L., Samuel, J., Zeng, X., & Wang, X. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.08.027 · Cited by 44
“2%) of human bone reported in the literature (Bayraktar et al., 2004; Currey, 2004; Gupta et al., 2006).”
BackgroundMethodResultInfluentialLui, H., Bindra, R. R., Baldwin, J., Ivanovski, S., & Vaquette, C. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900133 · Cited by 44
Obada, D. O., Osseni, S. A., Sina, H., et al. (2021) · Applied Clay Science · doi:10.1016/j.clay.2021.106298 · Cited by 43
Alginate/Chitosan Compact Polyelectrolyte Complexes: A Cell and Bacterial Repellent Material
Phoeung, T., Spanedda, M. V., Roger, E., Heurtault, B., Fournel, S., Reisch, A., Mutschler, A., Perrin‐Schmitt, F., Hemmerlé, J., Collin, D., et al. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b03863 · Cited by 43
Investigation of viscoelastoplastic response of bone tissue in oral implants press fit process
NATALI, A. N., Carniel, E. L., & Pavan, P. G. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31469 · Cited by 43
Hydrogel Coatings of Implants for Pathological Bone Repair
Li, M., Fan, Y., Ran, M., Chen, H., Han, J., Zhai, J., Wang, Z., Ning, C., Shi, Z., & Yu, P. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401296 · Cited by 43
Tuncer, M., Hansen, U. N., & Amis, A. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.04.006 · Cited by 42
Rapagna, S., Berahmani, S., Wyers, C. E., et al. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.04.054 · Cited by 42
“As permanent deformation is being investigated in this study and the yield strain of bone is 7,000 to 10,000 με (Bayraktar et al., 2004; Morgan and Keaveny, 2001), this level of precision error (2–7%) is still deemed acceptable, as it is less than 10% of the nominal strain (Bay et al.”
BackgroundResultBenca, E., Synek, A., Amini, M., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-46739-y · Cited by 42
Smith, B. T., Bittner, S. M., Watson, E., Smoak, M. M., Díaz-Gómez, L. A., Molina, E. R., Kim, Y. S., Hudgins, C. D., Melchiorri, A. J., Scott, D. W., et al. (2019) · Tissue Engineering Part A · doi:10.1089/ten.tea.2019.0204 · Cited by 43
On the Road to Personalized Medicine: Multiscale Computational Modeling of Bone Tissue
Podshivalov, L., Fischer, A., & Bar‐Yoseph, P. (2014) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9120-1 · Cited by 40
Carnelli, D., Gastaldi, D., Sassi, V., Contro, R., Ortiz, C., & Vena, P. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001358 · Cited by 41
Primary Cilia Exist in a Small Fraction of Cells in Trabecular Bone and Marrow
Coughlin, T. R., Voisin, M. C., Schaffler, M. B., Niebur, G. L., & McNamara, L. M. (2014) · Calcified Tissue International · doi:10.1007/s00223-014-9928-6 · Cited by 41
“Trabecular and cortical bone respond differently to mechanical loading [39] and also have different mechanical properties [40].”
Self-citationKim, J. J., Nam, J., & Jang, I. G. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.11.007 · Cited by 41
Reeves, J. M., Langohr, G. D. G., Athwal, G. S., & Johnson, J. A. (2018) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2018.06.002 · Cited by 41
Wirth, A. J., Mueller, T. L., Vereecken, W., Flaig, C., Arbenz, P., Müller, R., & van Lenthe, H. (2009) · Archive of Applied Mechanics · doi:10.1007/s00419-009-0387-x · Cited by 41
“As well, it has been shown that at the apparent level, these μFE models can accurately predict trabecular bone failure for bovine [32] as well as for human trabecular bone [33]; the μFE-predicted apparent stresses and strains at failure were equal to experimentally measured values for the same bone specimens.”
BackgroundTomar, V. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2903434 · Cited by 41
Frank, M., Reisinger, A., Andriotis, O. G., Pahr, D. H., & Thurner, P. J. (2024) · JBMR Plus · doi:10.1093/jbmrpl/ziae049 · Cited by 48
“This statement is flawed, however, as it is clear, from this and other studies, 38,50–52, 54– 57, 62 , 63 that trabecular and cortical bone are two In this context, a significant reduction of cortical bone and increase of trabecular bone at the femoral neck would firstly reduce the compressive and…”
ResultComparison of patellar bone strain in the natural and implanted knee during simulated deep flexion
Fitzpatrick, C. K., Baldwin, M. A., Ali, A. A., Laz, P. J., & Rullkoetter, P. J. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21211 · Cited by 40
Cortical bone fracture analysis using XFEM – case study
Idkaidek, A., & Jasiuk, I. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2809 · Cited by 40
“4% is used as a failure criterion [18, 19] as described in Equation 2.”
MethodBerahmani, S., Janssen, D. W., & Verdonschot, N. J. J. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.07.023 · Cited by 40
Altai, Z., Qasim, M., Li, X., et al. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.06.004 · Cited by 40
“04% for tensile and compressive strains, respectively (Bayraktar et al., 2004).”
BackgroundLee, J.-I., Lee, Y., Kim, Y., et al. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.08.021 · Cited by 40
Bae, J. Y., Kwak, D., Park, K. S., & Jeon, I. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0851-1 · Cited by 39
Developing CT based computational models of pediatric femurs
Li, X., Viceconti, M., Cohen, M. C., Reilly, G. C., Carré, M., & Offiah, A. C. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.03.027 · Cited by 39
“This would affect the validity of the yield strain used in this study, which is based on previous experiments from adult bones (Bayraktar et al., 2004).”
InfluentialRidzwan, M. I. Z., Sukjamsri, C., Pal, B., et al. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23669 · Cited by 39
“04%, respectively.(30,31) Assessing the FE-predicted fracture type based on just one element or a small area that first reaches the critical failure threshold was not considered sufficiently accurate, since an initial failure may get arrested with subsequent failure initiating in another region of the femur.”
BackgroundKim, T. W., Lee, M. C., Cho, J., et al. (2019) · The American Journal of Sports Medicine · doi:10.1177/0363546519869325 · Cited by 39
McDonald, K. A., Little, J. P., Pearcy, M. J., & Adam, C. J. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.04.006 · Cited by 38
Age‐related optimization of screw placement for reduced loosening risk in locked plating
MacLeod, A. R., Simpson, H., & Pankaj, P. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23193 · Cited by 38
“7%, respectively).(59,60) While this study was limited to two bone qualities, it would be possible to incorporate patient-specific bone properties in the models.”
BackgroundSyahrom, A., Kadir, M. R. A., Abdullah, J. B., & Öchsner, A. Ö. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0833-0 · Cited by 38
In vitro evidence of the structural optimization of the human skeletal bones
Cristofolini, L. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.010 · Cited by 38
Luo, Y., Ferdous, Z., & Leslie, W. D. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911424975 · Cited by 38
Yao, B., Zhang, Z., Li, Z., et al. (2024) · Powder Technology · doi:10.1016/j.powtec.2024.119856 · Cited by 37
Püschel, T. A., & Sellers, W. I. (2015) · American Journal of Physical Anthropology · doi:10.1002/ajpa.22882 · Cited by 37
“Even though several material properties for primate cortical and trabecular bone have been published especially for humans (e.g., Currey and Butler, 1975; Williams and Lewis, 1982; Currey, 1988; Dechow et al., 1993; Ding et al., 1998; Zysset et al., 1999; Margulies and Thibault, 2000; Phelps et al., 2000; Dechow and H…”
BackgroundPrevalence of Poor Bone Quality in Women Undergoing Spinal Fusion Using Biomechanical-CT Analysis
Burch, S., Feldstein, M., Hoffmann, P., & Keaveny, T. M. (2015) · Spine · doi:10.1097/brs.0000000000001175 · Cited by 36
Self-citationLiu, X. S., Wang, J., Zhou, B., Stein, E. M., Shi, X., Adams, M., Shane, E. J., & Guo, X.-D. E. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1919 · Cited by 36
“81% strain in compression, respectively.((51)) After the yield point, the postyield modulus was decreased to approximately 5% of the initial value.”
BackgroundMethodDeformation of anodic aluminum oxide nano-honeycombs during nanoindentation
Ng, K. Y., Lin, Y., & Ngan, A. H. W. (2009) · Acta Materialia · doi:10.1016/j.actamat.2009.02.025 · Cited by 36
Bhuiyan, D. B., Middleton, J. C., Tannenbaum, R., & Wick, T. M. (2016) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2016.1184121 · Cited by 34
Intraoperative biomechanics of lumbar pedicle screw loosening following successful arthrodesis
Pearson, H. B., Dobbs, C. J., Grantham, E., Niebur, G. L., Chappuis, J. L., & Boerckel, J. D. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23575 · Cited by 36
“Reported yield stresses for spinal trabecular bone range from 3 to 96MPa.(49,50) Using the von Mises stress as a measure of failure propensity, we calculated local stresses at the screw entry point of 50MPa at median pedicle/instrumentation geometries, suggesting that local stresses may contribute to loosening through…”
BackgroundSelf-citationPatient-specific finite element analysis of femurs with cemented hip implants
Katz, Y., Lubovsky, O., & Yosibash, Z. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.06.012 · Cited by 37
“The yield load in stance position is the load resulting in a maximum408 principal strain in tension equal to 7300 µstrain (Bayraktar et al., 2004).409 FFB1L and FFB1R, loaded at 15o, experienced yielding at the neck at ∼8100 N and410 7600 N and brittle-like tensile fracture at 8600 and 8100 N…”
BackgroundBoughton, O. R., Ma, S., Cai, X., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-43686-6 · Cited by 36
Cortical bone mapping improves finite element strain prediction accuracy at the proximal femur
Schileo, E., Pitocchi, J., Falcinelli, C., & Taddei, F. (2020) · Bone · doi:10.1016/j.bone.2020.115348 · Cited by 36
Liebl, H., García, E. G., Holzner, F., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0116907 · Cited by 36
“To include only elements with high density for the analysis a BMD threshold value of 500 mg/cm(3) was used as previously published to differentiate between cortical and trabecular bone [33,34].”
MethodThe effect of impact direction on the fracture load of osteoporotic proximal femurs
Wakao, N., Harada, A., Matsui, Y., Takemura, M., Shimokata, H., Mizuno, M., Ito, M., Matsuyama, Y., & Ishiguro, N. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.07.010 · Cited by 36
A Review of the Impacts of Implant Stiffness on Fracture Healing
Mori, Y., Kamimura, M., Ito, K., Koguchi, M., Tanaka, H., Kurishima, H., Koyama, T., Mori, N., Masahashi, N., & Aizawa, T. (2024) · Applied Sciences · doi:10.3390/app14062259 · Cited by 38
“Indeed, Young’s moduli of Ti6Al4V alloy and CP-Ti, although lower than that of stainless steel, are still considerably higher than that of the human cortical bone, which typically ranges from 11 GPa to 20 GPa [47].”
BackgroundGrossman, G., Waninger, K. N., Voloshin, A., et al. (2008) · Journal of Dance Medicine & Science · doi:10.1177/1089313x0801200404 · Cited by 35
Strain distribution in the lumbar vertebrae under different loading configurations
Cristofolini, L., Brandolini, N., Danesi, V., Juszczyk, M., Erani, P., & Viceconti, M. (2013) · The Spine Journal · doi:10.1016/j.spinee.2013.06.014 · Cited by 35
Edwards, W. B., Schnitzer, T. J., & Troy, K. L. (2013) · Bone · doi:10.1016/j.bone.2013.12.012 · Cited by 37
“The non-linear phase was modeled as bilinear elastic–plastic with a post-yield modulus equal to 5% of the pre-yield modulus [35]; yield was defined using Hill's conventional criterion for orthotropic materials.”
MethodBhuiyan, D. B., Jablonsky, M. J., Kolesov, I., Middleton, J., Wick, T. M., & Tannenbaum, R. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.044 · Cited by 35
Nawathe, S., Juillard, F., & Keaveny, T. M. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.02.011 · Cited by 35
“Such yielding comprised a modified von-Mises criterion with tension-compression strength asymmetry (Bayraktar et al., 2004; Niebur et al., 2000), which was achieved by introducing pseudo-kinematic hardening to shift the yield envelope.”
InfluentialSelf-citationAjaxon, I., Acciaioli, A., Lionello, G., Ginebra, M., Öhman‐Mägi, C., Baleani, M., & Persson, C. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.06.023 · Cited by 35
Ovesy, M., Indermaur, M., & Zysset, P. K. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.06.024 · Cited by 35
Obata, Y., Bale, H., Barnard, H. S., Parkinson, D., Alliston, T. N., & Acevedo, C. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103887 · Cited by 35
Gustafsson, A., Tognini, M., Bengtsson, F., Gasser, T. C., Isaksson, H., & Grassi, L. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104118 · Cited by 36
Biomechanics of immature human cortical bone: A systematic review
Szabo, E., & Rimnac, C. M. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104889 · Cited by 35
Integrated remodeling-to-fracture finite element model of human proximal femur behavior
Hambli, R., Lespessailles, É., & Benhamou, C.-L. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.08.011 · Cited by 35
Investigation of bone inelastic response in interaction phenomena with dental implants
NATALI, A. N., Carniel, E. L., & Pavan, P. G. (2008) · Dental Materials · doi:10.1016/j.dental.2007.11.024 · Cited by 35
“Permanent strain phenomena can develop when heavy loading conditions are applied [35,36,14].”
BackgroundSimulation of vertebral trabecular bone loss using voxel finite element analysis
Donnell, P. M., Harrison, N. M., Liebschner, M. A. K., & McHugh, P. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.038 · Cited by 35
Falcinelli, C., Martino, A. C. D., Gizzi, A., Vairo, G., & Denaro, V. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.01.014 · Cited by 34
Zhai, X., Gao, J., Nie, Y., Guo, Z., Kedir, N., Claus, B., Sun, T., Fezzaa, K., Xiao, X., & Chen, W. W. (2019) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2019.07.010 · Cited by 34
Terzini, M., Aldieri, A., Rinaudo, L., Osella, G., Audenino, A. L., & Bignardi, C. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00220 · Cited by 35
“element centroid, a Risk of Fracture (RF) was computed dividing the prevailing principal strain, evaluated comparing tensile and compressive principal strains, by the respective threshold value (Bayraktar et al., 2004).”
MethodZhai, X., Nauman, E. A., Moryl, D. L., Lycke, R., & Chen, W. W. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103597 · Cited by 34
Liu, F., Liu, C., Zheng, B., et al. (2020) · Polymers · doi:10.3390/polym12010069 · Cited by 34
“It is noted that the compressive strength (i.e., 1.020 ± 0.122 MPa) of the SF/SPI/β-TCP scaffold is similar to that of the natural trabecular bone (1–7 MPa) [44].”
BackgroundInfluentialDubey, D. K., & Tomar, V. (2007) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2007.10.011 · Cited by 33
“Micro-scale finite element models have been used to investigate the elastic (Van Rietbergen et al., 2000) and the yield properties of trabecular bone ( Bayraktar et al., 2004a ).”
BackgroundEdwards, W. B., Simonian, N., Troy, K. L., & Schnitzer, T. J. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2474 · Cited by 37
“with a postyield modulus that was 5% of the pre-yield modulus((31)); yield was defined using the quadratic Hill criterion for orthotropic materials.”
BackgroundGupta, A. K., Bayraktar, H. H., Fox, J. C., Keaveny, T. M., & Papadopoulos, P. (2006) · Computational Mechanics · doi:10.1007/s00466-006-0082-5 · Cited by 33
“Although trabecular bone is stronger in compression than in tension [18, 19 ], some of these studies have used the von Mises failure criterion that assumes equal compressive and tensile strength [14, 20].”
ResultSelf-citationvan Lenthe, H., & Müller, R. (2006) · Drug Discovery Today Technologies · doi:10.1016/j.ddtec.2006.06.001 · Cited by 34
Donaldson, F. E., Pankaj, P., Cooper, D. M. L., Thomas, C. D. L., Clement, J. G., & Simpson, H. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/2041303310395675 · Cited by 33
Tai, B. L., Kao, Y.-T., Payne, N., et al. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.08.004 · Cited by 33
Kok, J., Širka, A., Grassi, L., Raina, D. B., Tarasevičius, Š., Tägil, M., Lidgren, L., & Isaksson, H. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.03.008 · Cited by 33
Winsor, C., Li, X., Qasim, M., Henak, C. R., Pickhardt, P. J., Ploeg, H., & Viceconti, M. (2020) · Bone · doi:10.1016/j.bone.2020.115759 · Cited by 33
Kinzl, M., Böger, A., Zysset, P. K., et al. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.02.012 · Cited by 33
“This value was calculated from the back-calculated elastic modulus and a tissue yield strain of 1.1% (taken from Bayraktar et al., 2004).”
BackgroundMethodInfluentialOliviero, S., Lü, Y., Viceconti, M., et al. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.10.026 · Cited by 33
“We assumed that tibia fails when 2% of the nodes reach a critical strain level (adapted from (Pistoia et al., 2002)), which was asymmetric for compression ( 10,300 me) or tension (8000 me) (Bayraktar et al., 2004). respectively.”
BackgroundRamesh, N., Ratnayake, J. T., Moratti, S. C., et al. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2020.05.269 · Cited by 32
Gebert, A., Peters, J., Bishop, N. E., et al. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.04.007 · Cited by 32
Constrained topological optimization of a football helmet facemask based on brain response
Johnson, K. L., Chowdhury, S., Lawrimore, W. B., Mao, Y., Mehmani, A., Prabhu, R. K., Rush, G. A., & Horstemeyer, M. F. (2016) · Materials & Design · doi:10.1016/j.matdes.2016.08.064 · Cited by 32
Metadata
- Authors
- Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of Notre Dame (US)
- Corresponding author
- Bayraktar, Harun H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 37
- Issue
- 1
- Pages
- 27-35
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2089968363
- Cited by
- 1,142
- References
- 36
- Citations by year
- 2026: 60 · 2025: 62 · 2024: 68 · 2023: 51 · 2022: 55 · 2021: 74 · 2020: 90 · 2019: 75 · 2018: 67 · 2017: 56 · 2016: 68 · 2015: 59 · 2014: 62 · 2013: 50 · 2012: 49
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- University of California, San Francisco
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784, AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- trabecular bone, cortical bone, femoral neck, elastic modulus, yield strain, tensile yield strength, compressive yield strength, finite element analysis
- MeSH terms
- Aged, Aged, 80 and over, Cadaver, Computer Simulation, Elasticity, Femur Head, Humans, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Stress, Mechanical, Tensile Strength, Reproducibility of Results, Weight-Bearing, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review