The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Abstract
The ability to determine trabecular bone tissue elastic and failure properties has biological and clinical importance. To date, trabecular tissue yield strains remain unknown due to experimental difficulties, and elastic moduli studies have reported controversial results. We hypothesized that the elastic and tensile and compressive yield properties of trabecular tissue are similar to those of cortical tissue. Effective tissue modulus and yield strains were calibrated for cadaveric human femoral neck specimens taken from 11 donors, using a combination of apparent-level mechanical testing and specimen-specific, high-resolution, nonlinear finite element modeling. The trabecular tissue properties were then compared to measured elastic modulus and tensile yield strain of human femoral diaphyseal cortical bone specimens obtained from a similar cohort of 34 donors. Cortical tissue properties were obtained by statistically eliminating the effects of vascular porosity. Results indicated that mean elastic modulus was 10% lower (p<0.05) for the trabecular tissue (18.0+/-2.8 GPa) than for the cortical tissue (19.9+/-1.8 GPa), and the 0.2% offset tensile yield strain was 15% lower for the trabecular tissue (0.62+/-0.04% vs. 0.73+/-0.05%, p<0.001). The tensile-compressive yield strength asymmetry for the trabecular tissue, 0.62 on average, was similar to values reported in the literature for cortical bone. We conclude that while the elastic modulus and yield strains for trabecular tissue are just slightly lower than those of cortical tissue, because of the cumulative effect of these differences, tissue strength is about 25% greater for cortical bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [142]
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,456
Zysset, P. K., Guo, X.-D. E., Hoffler, C. E., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,001
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationAging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Cited by
Sorted by citations
Items 301–400 of 1,000
Dental implants press fit phenomena: Biomechanical analysis considering bone inelastic response
NATALI, A. N., Carniel, E. L., & Pavan, P. G. (2009) · Dental Materials · doi:10.1016/j.dental.2008.11.002 · Cited by 32
“Experimental data show that hardening phenomena within bone tissue develop according to an almost linear trend [25,26].”
BackgroundPostmortem Change and its Effect on Evaluation of Fractures
Kemp, W. L. (2016) · Academic Forensic Pathology · doi:10.23907/2016.004 · Cited by 31
The structure and mechanical properties of bone
Currey, J. D. (2008) · Elsevier eBooks · doi:10.1533/9781845694227.1.3 · Cited by 31
Aldieri, A., Terzini, M., Osella, G., Priola, A. M., Angeli, A., Veltri, A., Audenino, A. L., & Bignardi, C. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4040586 · Cited by 30
Júnior, E. J. M. D. M., & Francischone, C. E. (2019) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.09.015 · Cited by 31
Analysis of micro fracture in human Haversian cortical bone under compression
Jonvaux, J., Hoc, T. P., & Budyn, É. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2478 · Cited by 30
“The calibration is initialised by the tensile strength value of t D 108 MPa that has been determined for bone in the literature [24].”
BackgroundBone architecture and fracture
Currey, J. D. (2005) · Current Osteoporosis Reports · doi:10.1007/s11914-005-0004-z · Cited by 31
“It seems that in aged humans at least the cancellous material yields, both in tension and compression, at slightly lower strains than the compact material [ 18 ].”
BackgroundÖzçivici, E., & Judex, S. (2014) · Bone · doi:10.1016/j.bone.2014.05.009 · Cited by 30
“3 [35–37].”
Nha, K. W., Chang, Y. M., Shon, O., et al. (2018) · The Journal of Knee Surgery · doi:10.1055/s-0038-1641144 · Cited by 31
Effects of Loading Orientation on the Morphology of the Predicted Yielded Regions in Trabecular Bone
Shi, X., Wang, X., & Niebur, G. L. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9619-4 · Cited by 30
Self-citationOsteogenesis of 3D printed macro-pore size biphasic calcium phosphate scaffold in rabbit calvaria
Liu, F., Liu, Y., Li, X., Wang, X., Li, D., Chung, S., Chen, C., & Lee, I.-S. (2019) · Journal of Biomaterials Applications · doi:10.1177/0885328218825177 · Cited by 30
Effect of repeated in vivo microCT imaging on the properties of the mouse tibia
Oliviero, S., Giorgi, M., Laud, P. J., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225127 · Cited by 30
“(adapted from [23]) of either -10300 με in compression or +8000 με in tension [24].”
Luo, C., Wu, X., Wan, Y., et al. (2020) · BioMed Research International · doi:10.1155/2020/6783936 · Cited by 30
“[26] used several theoretical models to explain the effects of external load on the BMD and its trabecular structure.”
MethodSalerno, A., & Netti, P. A. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.682133 · Cited by 31
Alveolar Bone Stress Around Implants With Different Abutment Angulation
Sadrimanesh, R., Siadat, H., Sadr‐Eshkevari, P., et al. (2012) · Implant Dentistry · doi:10.1097/id.0b013e31824c302e · Cited by 30
“The null hypothesis of this study was that stress values associated with labially inclined fixtures are within the nondestructive range (below the yield strengths described in the literature).(31)”
BackgroundDistinct Tissue Mineral Density in Plate- and Rod-like Trabeculae of Human Trabecular Bone
Wang, J., Kazakia, G. J., Zhou, B., Shi, X., & Guo, X. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2498 · Cited by 30
“For the heterogeneous models, 32 material properties were adopted based on the linear correlation between TMD and tissue modulus.((21,22)) For the homogeneous model, the elastic modulus was assumed according to the average TMD based on the linear relation.”
MethodA REVIEW OF FINITE ELEMENT APPLICATIONS IN ORAL AND MAXILLOFACIAL BIOMECHANICS
Doğru, S. C., Cansız, E., & Arslan, Y. Z. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519418300028 · Cited by 30
2D-3D reconstruction of the proximal femur from DXA scans: Evaluation of the 3D-Shaper software
Dudle, A., Gugler, Y., Pretterklieber, M. L., Ferrari, S., Lippuner, K., & Zysset, P. K. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1111020 · Cited by 29
“Overall, these numbers are in line with literature values (Reilly and Burstein, 1974; Cezayirlioglu et al., 1985; Bayraktar et al., 2004; Öhman et al., 2011).”
Tomar, V. (2008) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2008.12.013 · Cited by 29
“Micro-scale finite element models have been used to investigate the elastic, Van Rietbergen et al. [13] and Odgaard et al. [14], and the yield failure properties of trabecular bone, Stolken and Kinney [15], Bayraktar et al. [8], and Bayraktar et al. [ 16 ].”
MethodTowards patient‐specific material modeling of trabecular bone post‐yield behavior
Carretta, R., Lorenzetti, S., & Müller, R. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2516 · Cited by 29
“The values for the parameters of each model are taken from the literature [120,130].”
BackgroundMethodBiesiekierski, A., Lin, J., Li, Y., et al. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.012 · Cited by 29
Altai, Z., Viceconti, M., Offiah, A. C., et al. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1008-9 · Cited by 29
“For human bone these limits have been reported to be 0.73% in tension and 1.04% in compression (Bayraktar et al. 2004).”
BackgroundInfluentialAltai, Z., Montefiori, E., van Veen, B., Paggiosi, M., McCloskey, E. V., Viceconti, M., Mazzà, C., & Li, X. (2021) · PLoS ONE · doi:10.1371/journal.pone.0245121 · Cited by 29
“04% for tensile and compressive strain, respectively) [44].”
BackgroundInfluentialAtlas of Human Skeleton Hardness Obtained Using the Micro‐indentation Technique
Li, S., Wang, J., Yin, B., et al. (2021) · Orthopaedic Surgery · doi:10.1111/os.12841 · Cited by 29
“tested the yield strain(5) and the modulus of trabecular bone from various anatomic sites; Bayraktar et al.(6) compared the elastic and yield properties of the femur; Helgason et al.”
BackgroundBiomechanics of Bone and Age-Related Fractures
Morgan, E. F., & Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00024-0 · Cited by 29
Self-citationNumerical modelling of impact fracture of cortical bone tissue using X-FEM
Abdelwahab, A. A., & Silberschmidt, V. V. (2011) · Loughborough University Institutional Repository (Loughborough University) · Cited by 29
Characterization of loose powder sintered porous titanium and Ti6Al4V alloy
Esen, Z., Bor, E. T., & Bor, Ş. (2009) · DergiPark (Istanbul University) · doi:10.3906/sag-1208-45 · Cited by 29
Lee, D. C., Varela, A., Kostenuik, P. J., Ominsky, M. S., & Keaveny, T. M. (2016) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2830 · Cited by 29
Self-citationYang, X.-J., Wang, F.-Q., Lu, C.-B., Zou, J.-W., Hu, J.-B., Yang, Z., Sang, H.-X., & Zhang, Y. (2020) · Biomedical Materials · doi:10.1088/1748-605x/ab8720 · Cited by 28
“83 GPa, which is comparable to the mechanical properties of natural bones [36, 37].”
Taddei, F., Palmadori, I., Taylor, W. R., Heller, M. O. W., Bordini, B., Toni, A., & Schileo, E. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.030 · Cited by 28
“73% tensile) (Bayraktar et al., 2004).”
Shape and function of the diaphysis of the human tibia
Cristofolini, L., Angeli, E., Juszczyk, J., & Juszczyk, M. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.04.026 · Cited by 28
Cheng, Y., Lin, D., Jiang, C., et al. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2820 · Cited by 28
Ovesy, M., Aeschlimann, M., & Zysset, P. K. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109844 · Cited by 28
Yang, X. H., Ma, W., Gu, W., et al. (2021) · RSC Advances · doi:10.1039/d1ra02355a · Cited by 28
Bone: A Composite Natural Material
Fatima, M., Canhão, H. M., & Eurico, J. (2011) · InTech eBooks · doi:10.5772/17523 · Cited by 30
“62 for trabecular bone (Bayraktar et al., 2004).”
Modeling microdamage behavior of cortical bone
Donaldson, F. E., Ruffoni, D., Schneider, P., et al. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0568-6 · Cited by 28
Baharuddin, M. Y., Salleh, S., Zulkifly, A. H., et al. (2014) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-15-30 · Cited by 28
“The results also illustrated that the stem maximum stress (65.38 MPa) did not exceed the bone’s yield strength which was 160 MPa, [16,51] and the intact femur.”
BackgroundInfluentialA novel methodology for generating 3D finite element models of the hip from 2D radiographs
Thevenot, J., Koivumäki, J., Kühn, V., et al. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.004 · Cited by 28
“the Young's modulus (Bayraktar et al., 2004), and an ultimate tensile stress presumed to be 0.”
BackgroundCorrelations between structural and mechanical properties of human trabecular femur bone.
Nikodem, A. (2012) · PubMed · Cited by 28
Architecture of bone tissue and its adaptation to pathological conditions
Bilgiç, E., Boyacıoğlu, Ö., Gizer, M., Korkusuz, P., & Korkusuz, F. (2020) · Comparative Kinesiology of the Human Body · doi:10.1016/b978-0-12-812162-7.00006-0 · Cited by 30
Yang, X., Wu, L., Li, C., Li, S., Hou, W., Hao, Y., Lu, Y., & Li, L. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c16459 · Cited by 29
Baleani, M., Erani, P., Acciaioli, A., et al. (2024) · Bioengineering · doi:10.3390/bioengineering11040395 · Cited by 27
“However, to our knowledge, this value comes from a few reports including two extensive studies [15,16] plus one single specimen within a larger inter-species investigation [17].”
BackgroundResultInfluentialLebrun, N., Dupla, F., Bruhier, H., Prudent, M., Borroto, A., Loughian, C. D., Bourquard, F., Pelletier, J. M., Rousseau, M., Colombier, J., et al. (2024) · Applied Surface Science · doi:10.1016/j.apsusc.2024.160617 · Cited by 27
Effective mechanical properties of diaphyseal cortical bone in the canine femur
Autefage, A., Palierne, S., Charron, C., & Swider, P. (2012) · The Veterinary Journal · doi:10.1016/j.tvjl.2012.04.001 · Cited by 28
Babo, P. S., Santo, V. E., Gomes, M. E., & Reis, R. L. (2016) · Macromolecular Bioscience · doi:10.1002/mabi.201600141 · Cited by 27
Savoldi, F., Tsoi, J. K. H., Paganelli, C., & Matinlinna, J. P. (2017) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2017.0116 · Cited by 27
“60 Lastly, the sutural ligament offered a resistance of 0.7 – 0.2 MPa for the sagittal suture and 0.5 – 0.1 MPa for the coronal suture, 28 compared with 25.8 – 0.7 GPa of the cortical bone, 61 both of which were subject to indentation.”
InfluentialThe influence of microstructure on crack propagation in cortical bone at the mesoscale
Gustafsson, A., Wallin, M., & Isaksson, H. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.110020 · Cited by 27
Curtis, K. J., Schiavi, J., Garrigle, M. J. M., Kumar, V., McNamara, L. M., & Niebur, G. L. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2020.0568 · Cited by 27
“However, their stiff substrates were made with polyurethane films which have moduli on the order of GPa, which is three orders of magnitude higher than the hydrogels in our study.”
MethodSelf-citationMolinari, L., Falcinelli, C., Gizzi, A., & Martino, A. C. D. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104359 · Cited by 27
Untaroiu, C. D., Kerrigan, J. R., Kam, C. Y., et al. (2007) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2007-22-0018 · Cited by 27
Allaf, R. M., & Rivero, I. V. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4367-7 · Cited by 27
“[40] Experimental and finite element modeling Human femoral head 35–86 J Mater Sci: Mater Med (2011) 22:1843–1853 1851”
BackgroundHarrison, N. M., & McHugh, P. E. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-009-0188-8 · Cited by 27
Martelli, S., Kersh, M. E., & Pandy, M. G. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.08.001 · Cited by 27
Liu, S., Qi, W., Zhang, Y., Wu, Z., Yan, Y., & Lei, W. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-83 · Cited by 27
“Although the yield stress in cancellous bone occurs at strains of 5-10%, the strain usually exceeds 60% before failure in the cellular structure of cancellous bone [26,35].”
BackgroundWidmer, R. P., Helgason, B., Hazrati, J., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151680 · Cited by 27
“04%, in agreement with the study of [50] (Fig 1).”
Assessment of finite element models for prediction of osteoporotic fracture
Lee, Y., Ogihara, N., & Lee, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.05.018 · Cited by 27
Elias, D., Valério, C. S., de Oliveira, D., et al. (2019) · The International Journal of Prosthodontics · doi:10.11607/ijp.6247 · Cited by 27
Shaunak, S., Dhinsa, B. S., & Khan, W. S. (2017) · Current Stem Cell Research & Therapy · doi:10.2174/1574888x11666160429122238 · Cited by 26
Lee, J.-H., Han, H., Kim, Y.-C., et al. (2017) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2017.06.015 · Cited by 26
“Considering that the maximum tensile strength of cortical bone is 108 MPa, as reported by Bayraktar et al. (Bayraktar et al., 2004), the distribution of stress to the cortical bone (ranging from 83.49 MPa to 92.55 MPa) is considere to be tolerable under all material conditions in our simulation model.”
BackgroundInfluentialFernández, M. P., Dall’Ara, E., Bodey, A. J., Parwani, R., Barber, A. H., Blunn, G. W., & Tozzi, G. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b01044 · Cited by 26
Yadav, R. N., Sihota, P., Uniyal, P., Neradi, D., Bose, J. C., Dhiman, V., Karn, S., Sharma, S., Aggarwal, S., Goni, V. G., et al. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110495 · Cited by 26
Singh, A. P., Rana, M., Pal, B., Datta, P., Majumder, S., & Chowdhury, A. R. (2023) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2023.103959 · Cited by 26
Patient-specific FE analyses of metatarsal bones with inhomogeneous isotropic material properties
Trabelsi, N., Milgrom, C., & Zohar Yosibash, A. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.08.030 · Cited by 26
Validation of a new multiscale finite element analysis approach at the distal radius
Johnson, J. E., & Troy, K. L. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.03.005 · Cited by 26
Numerical Modelling of Femur Fracture and Experimental Validation Using Bone Simulant
Marco, M., Giner, E., Larrainzar‐Garijo, R., Caeiro, J. R., & Miguélez, M. H. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1877-6 · Cited by 26
“either a maximum or a minimum stress/strain criterion is used to localise the fracture point in the numerical models, with different fracture limits for tension and compression [3].”
Fracture analysis of multi-osteon cortical bone using XFEM
Idkaidek, A., Korić, S., & Jasiuk, I. (2017) · Computational Mechanics · doi:10.1007/s00466-017-1491-3 · Cited by 26
Awadalla, M., Al‐Dirini, R. M. A., O’Rourke, D., Solomon, L. B., Heldreth, M., & Taylor, M. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.23851 · Cited by 26
“Strain was analyzed to examine load transfer and the likelihood of bone failure by quantifying the percent of bone at or above the yield strain (Yield equivalent strain for bone (cancellous and cortical) in tension is approximately 7,000me).(35,36) In addition, clinically strain can be a proxy measure of implant migra…”
MethodDevelopment of a novel TiNbTa material potentially suitable for bone replacement implants
Chicardi, E., Gutiérrez-González, C. F., Sayagués, M. J., et al. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.02.042 · Cited by 26
The effect of short-stem humeral component sizing on humeral bone stress
Langohr, G. D. G., Reeves, J. M., Roche, C. P., Faber, K. J., & Johnson, J. A. (2019) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2019.08.018 · Cited by 26
Ghavidelnia, N., Hedayati, R., Sadighi, M., et al. (2020) · Applied Mathematical Modelling · doi:10.1016/j.apm.2020.03.002 · Cited by 26
Nawathe, S., Yang, H., Fields, A. J., et al. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.02.066 · Cited by 25
“33% in tension, respectively (Bayraktar et al., 2004).”
Self-citationEffect of stem position and length on bone-stem constructs after cementless hip arthroplasty
Kwak, D.-K., Bang, S.-H., Lee, S., Park, J.-H., & Yoo, J. (2021) · Bone and Joint Research · doi:10.1302/2046-3758.104.bjr-2020-0043.r3 · Cited by 25
Zheng, L., Chen, X., Zheng, Y., et al. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04878-2 · Cited by 25
The role of long non‐coding RNAs and circular RNAs in bone regeneration: Modulating miRNAs function
Ping, J., Li, L., Dong, Y., Wu, X., Huang, X., Sun, B., Zeng, B., Xu, F., & Liang, W. (2021) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.3277 · Cited by 25
Finite Element Models of Osteocytes and Their Load-Induced Activation
Smit, T. H. (2022) · Current Osteoporosis Reports · doi:10.1007/s11914-022-00728-9 · Cited by 25
Similar damage initiation but different failure behavior in trabecular and cortical bone tissue
Szabó, M. E., Zekonyte, J., Katsamenis, O. L., Taylor, M., & Thurner, P. J. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.036 · Cited by 25
Trabecular bone failure at the microstructural level
Müller, R., & van Lenthe, H. (2006) · Current Osteoporosis Reports · doi:10.1007/s11914-006-0007-4 · Cited by 26
“Recently, it has been shown that these μFE models can also accurately predict trabecular bone failure for both bovine [51••] and human [ 52 ] trabecular bone.”
BackgroundAssessment of bone quality and strength with new technologies
Engelke, K. (2012) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0b013e32835a2609 · Cited by 25
“The FEA outcome depends on the loading conditions [25,26], on the assigned relationship between BMD and material properties, which, for example, differs for trabecular and cortical bone [27,28]), and the specific simulation algorithm used for FEA simulation [29].”
MethodA three-dimensional finite element analysis of the human hip
Akrami, M., Craig, K., Dibaj, M., et al. (2018) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1576795 · Cited by 25
Sinclair, K. D., Farnsworth, R. W., Pham, T. X., Knight, A. N., Bloebaum, R. D., & Skedros, J. G. (2013) · Journal of Human Evolution · doi:10.1016/j.jhevol.2013.01.003 · Cited by 25
“(1994a,b, 2001), Bayraktar et al. (2004), and Mittra et al.”
BackgroundReich, T., & Gefen, A. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-45 · Cited by 25
“6 g/cm3 for humans, and elastic modulus of cortical bone, 17–20 GPa, ultimate tensile strength, 100–300 MPa, and tensile strain to failure, ~6,000–13,000 μm/m, also overlap [17,21-26].”
BackgroundRieger, R., Aurégan, J.-C., & Hoc, T. P. (2017) · Morphologie · doi:10.1016/j.morpho.2017.07.175 · Cited by 24
Singh, P. K., Singh, I. B., & Mondal, D. P. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.01.054 · Cited by 23
3D full-field biomechanical testing of a glenoid before and after implant placement
Zhou, Y., Gong, C., Lewis, G. S., et al. (2019) · Extreme Mechanics Letters · doi:10.1016/j.eml.2019.100614 · Cited by 24
Kwak, D.-K., Bang, S.-H., Kim, W., Lee, S., Lee, S., & Yoo, J. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253862 · Cited by 24
Algorithms for a strain‐based plasticity criterion for bone
Pankaj, P., & Donaldson, F. E. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2491 · Cited by 24
Caouette, C., Rauch, F., Villemure, I., et al. (2014) · PubMed · Cited by 24
Bone remodelling around a cementless glenoid component
Suárez, D. R., Weinans, H., & van Keulen, F. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0360-9 · Cited by 25
Femoral head necrosis: A finite element analysis of common and novel surgical techniques
Cilla, M., Checa, S., Preininger, B., Winkler, T., Perka, C., Duda, G. N., & Pumberger, M. (2017) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2017.07.005 · Cited by 24
“…1999): ROF= ε/ εlim Where ε is the maximum absolute principal strain at each element of the femur (either compressive or tensile) and εlim is the corresponding ultimate strain (ultimate compressive strain: 0.0104 and ultimate tensile strain: 0.0073) (Bayraktar et al., 2004; Ford et al., 1996).”
InfluentialPalanca, M., Bròdano, G. B., & Cristofolini, L. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4040587 · Cited by 24
Al‐Dirini, R. M. A., Martelli, S., O’Rourke, D., Huff, D. N., Ju, Z., Clement, J. G., Besier, T. F., & Taylor, M. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.013 · Cited by 24
“Also, the yield strain for bone, 7,000 με (Bayraktar et al., 2004), was used as a threshold for identifying areas of potential bone damage.”
MethodLee, J., Lee, J., Lee, J.-W., et al. (2013) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2013.10.003 · Cited by 24
“1) Biomechanically stability was indicated when the maximum VMS of cortical bone was lower than 108 MPa, the maximum yield strength of cortical bone reported by Bayraktar et al.27 2) The maximum VMS of cancellous bone also was taken into consideration when the first criterion failed to delineate the comparison.”
BackgroundCheng, Y., Jiang, C., & Lin, D. (2018) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-018-2104-2 · Cited by 23
“The experimental data for human trabecular bone specimens (Bayraktar et al. 2004) shows that the maximum respective tensile and compressive yield stresses for cancellous bone are 84.9 ± 11.2 MPa and 135.3 ± 34.3MPa.”
BackgroundInfluentialZheng, L., Wong, D. W., Chen, X., et al. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1964488 · Cited by 23
“The yield stress of the titanium alloy was 250MPa approximated from two studies (Namjoshi et al. 2002; Edwards and Ramulu 2014).”
BackgroundInfluentialBori, E., Armaroli, F., & Innocenti, B. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106499 · Cited by 23
Demir, O., Uslan, İ., Büyük, M., & Salamci, M. U. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106207 · Cited by 23
Schwiedrzik, J. J., & Zysset, P. K. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.818665 · Cited by 23
The effects of musculoskeletal loading regimes on numerical evaluations of acetabular component
Mukherjee, K., & Gupta, S. (2016) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411916661368 · Cited by 23
“Moreover, bone failure is often associated with much higher strain values of 7000– 10,000 me.(46,76) Therefore, there was hardly any risk of cortical bone failure owing to the increase in its strains during immediate post-operative condition.”
BackgroundFrank, M., Marx, D., Nedelkovski, V., Fischer, J.-T., Pahr, D. H., & Thurner, P. J. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.07.039 · Cited by 23
Comini, F., Palanca, M., Cristofolini, L., et al. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.01.041 · Cited by 23
Metadata
- Authors
- Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of Notre Dame (US)
- Corresponding author
- Bayraktar, Harun H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 37
- Issue
- 1
- Pages
- 27-35
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2089968363
- Cited by
- 1,142
- References
- 36
- Citations by year
- 2026: 60 · 2025: 62 · 2024: 68 · 2023: 51 · 2022: 55 · 2021: 74 · 2020: 90 · 2019: 75 · 2018: 67 · 2017: 56 · 2016: 68 · 2015: 59 · 2014: 62 · 2013: 50 · 2012: 49
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- University of California, San Francisco
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784, AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- trabecular bone, cortical bone, femoral neck, elastic modulus, yield strain, tensile yield strength, compressive yield strength, finite element analysis
- MeSH terms
- Aged, Aged, 80 and over, Cadaver, Computer Simulation, Elasticity, Femur Head, Humans, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Stress, Mechanical, Tensile Strength, Reproducibility of Results, Weight-Bearing, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review