Quantitative Multiple Reaction Monitoring of Peptide Abundance Introduced via a Capillary Zone Electrophoresis–Electrospray Interface
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We demonstrate the use of capillary zone electrophoresis with an electrokinetic sheath-flow electrospray interface coupled to a triple-quadrupole mass spectrometer for the accurate and precise quantification of Leu-enkephalin in a complex mixture using multiple-reaction monitoring (MRM). Assay time is <6 min, with no re-equilibration required between runs. A standard curve of Leu-enkephalin was performed in the presence of a background tryptic digest of bovine albumin. We demonstrate reasonably reproducible peak heights (21% relative standard deviation), retention times (better than 1% relative standard deviation), and robust electrospray quality. Our limit of detection (3σ) was 60 pM, which corresponds to the injection of 335 zmol of peptide. This is a 10-20-fold improvement in mass sensitivity than we have obtained by nano HPLC/MRM and substantially better than reported for LC/MS/MS. Further quantification was performed in the presence of stable-isotope-labeled versions of the peptides; under these conditions, linearity was observed across nearly 4 orders of magnitude. The concentration detection limit was 240 pM for the stable-isotope-labeled quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Desiere, F. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj040 · Cited by 910
Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Self-citationLi, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128
Self-citationCapillary electrophoresis with Orbitrap-Velos mass spectrometry detection
Wojcik, R., Li, Y., MacCoss, M. J., & Dovichi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.10.048 · Cited by 43
Self-citation
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216
“[19] We also used this first-generation nanospray system for the first multiple reaction monitoring experiment using CZE-MS;[20] we obtained a ~300-zmole peptide detection limit for a standard peptide spiked in bovine serum albumin tryptic digest background.[20] We also generated confident and reproducible detection o…”
Self-citationUltrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Self-citationZhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac303750g · Cited by 103
Self-citationOptimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95
Self-citationCapillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61
Self-citationCE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56
Self-citationZhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55
Self-citationWang, C., Lee, C. S., Smith, R. D., & Tang, K. (2013) · Analytical Chemistry · doi:10.1021/ac401202c · Cited by 46
Wang, C., Lee, C. S., Smith, R. D., & Tang, K. (2012) · Analytical Chemistry · doi:10.1021/ac302616m · Cited by 38
Nguyen, T. T. T. N., Petersen, N. J., & Rand, K. D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.002 · Cited by 33
Boley, D. A., Zhang, Z., & Dovichi, N. J. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.07.022 · Cited by 29
Self-citationMou, S., Sun, L., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac402858a · Cited by 22
Self-citation
Metadata
- Authors
- Li, Y., Wojcik, R., Dovichi, N. J., & Champion, M. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-27
- Volume
- 84
- Issue
- 14
- Pages
- 6116-6121
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2035411948
- Cited by
- 52
- References
- 7
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.