The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
General Strategy for Biodetection in High Ionic Strength Solutions Using Transistor-Based Nanoelectronic Sensors
Open accessAbstract
Transistor-based nanoelectronic sensors are capable of label-free real-time chemical and biological detection with high sensitivity and spatial resolution, although the short Debye screening length in high ionic strength solutions has made difficult applications relevant to physiological conditions. Here, we describe a new and general strategy to overcome this challenge for field-effect transistor (FET) sensors that involves incorporating a porous and biomolecule permeable polymer layer on the FET sensor. This polymer layer increases the effective screening length in the region immediately adjacent to the device surface and thereby enables detection of biomolecules in high ionic strength solutions in real-time. Studies of silicon nanowire field-effect transistors with additional polyethylene glycol (PEG) modification show that prostate specific antigen (PSA) can be readily detected in solutions with phosphate buffer (PB) concentrations as high as 150 mM, while similar devices without PEG modification only exhibit detectable signals for concentrations ≤10 mM. Concentration-dependent measurements exhibited real-time detection of PSA with a sensitivity of at least 10 nM in 100 mM PB with linear response up to the highest (1000 nM) PSA concentrations tested. The current work represents an important step toward general application of transistor-based nanoelectronic detectors for biochemical sensing in physiological environments and is expected to open up exciting opportunities for in vitro and in vivo biological sensing relevant to basic biology research through medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Self-citationPoly(ethylene glycol) in Drug Delivery: Pros and Cons as Well as Potential Alternatives
Knop, K., Hoogenboom, R., Fischer, D., & Schubert, U. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200902672 · Cited by 3,533
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Self-citationNoncovalent functionalization of carbon nanotubes for highly specific electronic biosensors
Chen, R. J., Bangsaruntip, S., Drouvalakis, K. A., Wong Shi Kam, N., Shim, M., Li, Y., Kim, W., Utz, P. J., & Dai, H. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0837064100 · Cited by 1,442
Poly(Ethylene Glycol) Chemistry: Biotechnical and Biomedical Applications
(1992) · Springer eBooks · doi:10.1007/978-1-4899-0703-5 · Cited by 1,420
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Self-citationEnzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Self-citationMohanty, N., & Berry, V. (2008) · Nano Letters · doi:10.1021/nl802412n · Cited by 1,208
MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
Sarkar, D., Liu, W., Xie, X., Anselmo, A. C., Mitragotri, S., & Banerjee, K. (2014) · ACS Nano · doi:10.1021/nn5009148 · Cited by 1,047
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citationPatolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.227 · Cited by 748
Self-citationPatolsky, F., & Lieber, C. M. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00791-1 · Cited by 699
Self-citationLabel-free detection of DNA hybridization using carbon nanotube network field-effect transistors
Star, A., Tu, E., Niemann, J., Gabriel, J.-C. P., Joiner, C. S., & Valcke, C. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504146103 · Cited by 670
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Analytical Chemistry · doi:10.1021/ac060830g · Cited by 660
Chen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645
Macroporous Nanowire Nanoelectronic Scaffolds for Synthetic Tissues
Jia Liu, B., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., Lieber, C. M., & Tian, B. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 642
Self-citationLabel-Free Biosensors Based on Aptamer-Modified Graphene Field-Effect Transistors
Ohno, Y., Maehashi, K., & Matsumoto, K. (2010) · Journal of the American Chemical Society · doi:10.1021/ja108127r · Cited by 554
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Label-free detection of small-molecule–protein interactions by using nanowire nanosensors
Wang, W. U., Chen, C., Lin, K.-H., Fang, Y., & Lieber, C. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406368102 · Cited by 534
Self-citationNanowire Sensors for Medicine and The Life Sciences
Patolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nanomedicine · doi:10.2217/17435889.1.1.51 · Cited by 489
Self-citationRamgir, N. S., Yang, Y., & Zacharias, M. (2010) · Small · doi:10.1002/smll.201000972 · Cited by 383
Complementary Detection of Prostate-Specific Antigen Using In2O3 Nanowires and Carbon Nanotubes
Li, C., Curreli, M., Lin, H., Lei, B., Ishikawa, F. N., Datar, R., Cote, R. J., Thompson, M. E., & Zhou, C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053761g · Cited by 378
Duan, X., Li, Y., Rajan, N. K., Routenberg, D. A., Modis, Y., & Reed, M. A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.82 · Cited by 366
Frenken, J. W. M., Oosterkamp, T. H., Hendriksen, B. L. M., & Rost, M. J. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00842-4 · Cited by 323
Graphene Field‐Effect Transistor and Its Application for Electronic Sensing
Zhan, B., Li, C., Yang, J., Jenkins, G., Huang, W., & Dong, X. (2014) · Small · doi:10.1002/smll.201400463 · Cited by 312
Latour, R. A. (2015) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35235 · Cited by 296
Biorecognition Layer Engineering: Overcoming Screening Limitations of Nanowire-Based FET Devices
Elnathan, R., Kwiat, M., Pevzner, A., Engel, Y., Burstein, L., Khatchtourints, A., Lichtenstein, A., Kantaev, R., & Patolsky, F. (2012) · Nano Letters · doi:10.1021/nl302434w · Cited by 231
Detection beyond the Debye Screening Length in a High-Frequency Nanoelectronic Biosensor
Kulkarni, G. S., & Zhong, Z. (2012) · Nano Letters · doi:10.1021/nl203666a · Cited by 208
Arnold, K., Herrmann, A., Pratsch, L., & Gawrisch, K. (1985) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(85)90381-5 · Cited by 147
Chen, C., Ganguly, A., Lu, C.-Y., Chen, T., Kuo, C.-C., Chen, R.-S., Tu, W.-H., Fischer, W. B., Chen, K., & Chen, L. (2011) · Analytical Chemistry · doi:10.1021/ac102489y · Cited by 146
ZnO nanowire biosensors for detection of biomolecular interactions in enhancement mode
Choi, A., Kim, K., Jung, H., & Lee, S. Y. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.04.049 · Cited by 132
Kinked p–n Junction Nanowire Probes for High Spatial Resolution Sensing and Intracellular Recording
Jiang, Z., Qing, Q., Xie, P., Gao, R., & Lieber, C. M. (2012) · Nano Letters · doi:10.1021/nl300256r · Cited by 131
Self-citationEngineering the pH‐Responsive Catalytic Behavior of AuNPs by DNA
Zhan, P., Wang, J., Wang, Z., & Ding, B. (2013) · Small · doi:10.1002/smll.201301931 · Cited by 117
25th Anniversary Article: Label‐Free Electrical Biodetection Using Carbon Nanostructures
Balasubramanian, K., & Kern, K. (2014) · Advanced Materials · doi:10.1002/adma.201304912 · Cited by 94
Agarwal, S. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781316146743 · Cited by 67
Gettens, R. T. T., Bai, Z., & Gilbert, J. L. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30218 · Cited by 57
Cited by
Carbon Nanomaterials for Biological Imaging and Nanomedicinal Therapy
Hong, G., Diao, S., Antaris, A. L., & Dai, H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00008 · Cited by 1,394
Self-citationDiverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationZhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Self-citationDetection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Two-dimensional nanomaterial-based field-effect transistors for chemical and biological sensing
Mao, S., Chang, J., Pu, H., Lu, G., He, Q., Zhang, H., & Chen, J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00827e · Cited by 404
Metadata
- Authors
- Gao, N., Zhou, W., Jiang, X., Hong, G., Fu, T.-M., & Lieber, C. M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-02-16
- Volume
- 15
- Issue
- 3
- Pages
- 2143-2148
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2054586727
- Cited by
- 268
- References
- 41
- FWCI
- 18.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.