The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Non-Invasive Optical Guided Tumor Metastasis/Vessel Imaging by Using Lanthanide Nanoprobe with Enhanced Down-Shifting Emission beyond 1500 nm
Abstract
Visualization of tumor vessels/metastasis and cerebrovascular architecture is vitally important for analyzing pathological states of brain diseases and a tumor’s abnormal blood vessels to improve cancer diagnoses. In vivo fluorescence imaging using second near-infrared emission beyond 1500 nm (NIR-IIb) has emerged as a next generation optical imaging method with significant improvement in imaging sensitivity and spatial resolution. Unfortunately, a highly biocompatible probe capable of generating NIR-IIb emission with sufficient brightness and uniformed size is still scarce. Here, we have proposed the poly(acrylic acid) (PAA)-modified NaLnF 4:40Gd/20Yb/2Er nanorods (Ln = Y, Yb, Lu, PAA-Ln-NRs) with enhanced downshifting NIR-IIb emission, high quantum yield (QY), relatively narrow bandwidth (∼160 nm), and high biocompatibility via Ce 3+ doping for high performance NIR-IIb bioimaging. The downshifting emission beyond 1500 nm is improved by 1.75–2.2 times with simultaneously suppressing the upconversion (UC) path in Y, Yb, and Lu hosts via Ce 3+ doping. Moreover, compared with the traditionally used Y-based host, the QY of NIR-IIb emission in the Lu-based probe in water is improved from 2.2% to 3.6%. The explored bright NIR-IIb emitted PAA-Lu-NRs were used for high sensitivity small tumor (∼4 mm)/metastatic tiny tumor detection (∼3 mm), tumor vessel visualization with high spatial resolution (41 μm), and brain vessel imaging. Therefore, our findings open up the opportunity of utilizing the lanthanide based NIR-IIb probe with bright 1525 nm emission for in vivo optical-guided tumor vessel/metastasis and noninvasive brain vascular imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Blood–brain barrier breakdown as a therapeutic target in traumatic brain injury
Shlosberg, D., Benifla, M., Kaufer, D., & Friedman, A. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.74 · Cited by 897
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Bright quantum dots emitting at ∼1,600 nm in the NIR-IIb window for deep tissue fluorescence imaging
Zhang, M., Yue, J., Cui, R., Ma, Z., Wan, H., Wang, F., Zhu, S., Zhou, Y., Kuang, Y., Zhong, Y., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1806153115 · Cited by 432
Qi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Traumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Cited by
Rare-Earth Doping in Nanostructured Inorganic Materials
Zheng, B., Fan, J., Chen, B., Qin, X., Wang, J., Wang, F., Deng, R., & Liu, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00644 · Cited by 1,204
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Nanoparticle Surface Functionalization: How to Improve Biocompatibility and Cellular Internalization
Sanità, G., Carrese, B., & Lamberti, A. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.587012 · Cited by 765
Liu, Y., Li, Y., Koo, S., Sun, Y., Liu, Y., Liu, X., Pan, Y., Zhang, Z., Du, M., Lu, S., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00553 · Cited by 537
Self-citationLi, Y., Cai, Z., Liu, S., Zhang, H., Wong, S. T. H., Lam, J. W. Y., Kwok, R. T. K., Qian, J., & Tang, B. Z. (2020) · Nature Communications · doi:10.1038/s41467-020-15095-1 · Cited by 464
Self-citation
Metadata
- Authors
- Li, Y., Zeng, S., & Hao, J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-03
- Volume
- 13
- Issue
- 1
- Pages
- 248-259
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2908266099
- Cited by
- 228
- References
- 11
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.