The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
M13 Phage-Functionalized Single-Walled Carbon Nanotubes As Nanoprobes for Second Near-Infrared Window Fluorescence Imaging of Targeted Tumors
Open accessAbstract
Second near-infrared (NIR) window light (950-1400 nm) is attractive for in vivo fluorescence imaging due to its deep penetration depth in tissues and low tissue autofluorescence. Here we show genetically engineered multifunctional M13 phage can assemble fluorescent single-walled carbon nanotubes (SWNTs) and ligands for targeted fluorescence imaging of tumors. M13-SWNT probe is detectable in deep tissues even at a low dosage of 2 μg/mL and up to 2.5 cm in tissue-like phantoms. Moreover, targeted probes show specific and up to 4-fold improved uptake in prostate specific membrane antigen positive prostate tumors compared to control nontargeted probes. This M13 phage-based second NIR window fluorescence imaging probe has great potential for specific detection and therapy monitoring of hard-to-detect areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Longmire, M., Choyke, P. L., & Kobayashi, H. (2008) · Nanomedicine · doi:10.2217/17435889.3.5.703 · Cited by 2,149
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Smart Nanomaterials in Cancer Theranostics: Challenges and Opportunities
Kashyap, B. K., Singh, V. V., Solanki, M. K., Kumar, A., Ruokolainen, J., & Kesari, K. K. (2023) · ACS Omega · doi:10.1021/acsomega.2c07840 · Cited by 348
Biosensing with Fluorescent Carbon Nanotubes
Ackermann, J., Metternich, J. T., Herbertz, S., & Kruss, S. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202112372 · Cited by 280
Carbon nanomaterials: multi-functional agents for biomedical fluorescence and Raman imaging
Bartelmess, J., Quinn, S. J., & Giordani, S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00306c · Cited by 259
Tang, Y., Li, Y., Lu, X., Hu, X., Zhao, H., Hu, W., Lu, F., Fan, Q., & Huang, W. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807376 · Cited by 96
(2023) · doi:10.1016/j.mtbio.2023.100612 · Cited by 71
Li, M., Lu, Z., Zhang, J., Chen, L., Tang, X., Jiang, Q., Hu, Q., Li, L., Liu, J., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202209647 · Cited by 56
(2023) · doi:10.3390/vaccines11050919 · Cited by 50
Piwoński, H., Li, W., Wang, Y., Michinobu, T., & Habuchi, S. (2020) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b00967 · Cited by 36
Ge, R.-T., Xiong, F., Chen, Z.-B., Wang, Y., Zheng, L., Zhou, J., Wu, D., & Zhang, S.-Y. (2025) · Chem · doi:10.1016/j.chempr.2025.102489 · Cited by 28
Zhang, R., He, X., Jiang, J.-M., Li, P.-P., Wang, H.-Y., Li, L., Yang, J.-X., & Kong, L. (2021) · Bioorganic Chemistry · doi:10.1016/j.bioorg.2021.104789 · Cited by 7
New role of bacteriophages in medical oncology
Moradi, M., Ghaleh, H. E. G., Bolandian, M., & Dorostkar, R. (2023) · Biotechnology and Applied Biochemistry · doi:10.1002/bab.2506 · Cited by 2
Metadata
- Authors
- Yi, H., Ghosh, D., Ham, M.-H., Qi, J., Barone, P. W., Strano, M. S., & Belcher, A. M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-06
- Volume
- 12
- Issue
- 3
- Pages
- 1176-1183
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2334075244
- Cited by
- 278
- References
- 4
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.