Cited by 28Luminescence and Fluorescent MaterialsMolecular Sensors and Ion DetectionOptical Imaging and Spectroscopy Techniques

Indocyanine polymethine fluorophores with extended π-conjugation emitting beyond 1,200 nm for enhanced NIR-II imaging

Ge, Rui-Tian, Xiong, Feng, Chen, Zhen-Bang, Wang, Yuanjie, Zheng, Lin, Zhou, Jia, Wu, Di, Zhang, Shu-Yu·2025·Chem

Integrity signals

Registry

Crossref · 10.1016/j.chempr.2025.102489

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Zhang et al. first reported the design of novel indocyanine polymethine fluorophores (Cy15s), achieving record-breaking emission wavelengths beyond 1200 nm.

    “Zhang et al. first reported the design of novel indocyanine polymethine fluorophores (Cy15s), achieving record-breaking emission wavelengths beyond 1200 nm (Fig. 14b)101.”
  • In murine models, SJ-1271-Micelles facilitated high-contrast NIR-IIb vascular imaging, with SNRs of 6.79 (hindlimb), 3.39 (abdomen), and 5.87 (brain).

    “In murine models, SJ-1271-Micelles facilitated high-contrast NIR-IIb vascular imaging, with SNRs of 6.79 (hindlimb), 3.39 (abdomen), and 5.87 (brain).”
  • Cy15 emission represented the longest wavelength reported for an indocyanine polymethine dye.

    “This emission represented the longest wavelength reported for an indocyanine polymethine dye.”
  • Zhang et al. developed indocyanine pentadecamethine fluorophores (Cy15s) via a π-chain elongation strategy, achieving ultra-long emission wavelengths and enhanced brightness.

    “Zhang et al. developed indocyanine pentadecamethine fluorophores (Cy15s) via a π-chain elongation strategy, achieving ultra-long emission wavelengths and enhanced brightness (Fig. 3b)101.”
  • Cy15 fluorophores displayed absorption and emission maxima at 1241 nm and 1287 nm, respectively.

    “The resulting Cy15 fluorophores displayed profoundly red-shifted optical properties, with absorption and emission maxima at 1241 nm and 1287 nm, respectively.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ge, R.-T., Xiong, F., Chen, Z.-B., Wang, Y., Zheng, L., Zhou, J., Wu, D., & Zhang, S.-Y.
Affiliations
Shanghai Jiao Tong University (CN)
Corresponding author
  • Wu, Di
  • Zhang, Shu-Yu
Venue
Chem
Publisher
Elsevier BV
Published
2025-07
Volume
11
Issue
7
Pages
102489
ISSN
2451-9294 (ISSN-L)
OpenAlex
W4408290752
Cited by
28
References
40
Citations by year
2026: 18 · 2025: 10
FWCI
5.91
Type
journal article
Language
en
Open access
closed
Locations
Chem (publishedVersion)
Funders
  • Shanghai Jiao Tong University (YG2022ZD021)
  • Key Scientific Research Project of Colleges and Universities in Henan Province (24A330005)
  • National Key Research and Development Program of China
  • Fundamental Research Funds for the Central Universities
  • Key Technologies Research and Development Program (2021YFF0701800)
  • Shanghai Municipality Science and Technology Commission
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
NIR-II fluorescence imaging, extended π-conjugation, deep tissue imaging, angiography, tissue penetration depth

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review