The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Arrhythmia risk stratification of patients after myocardial infarction using personalized heart models
Open accessAbstract
Sudden cardiac death (SCD) from arrhythmias is a leading cause of mortality. For patients at high SCD risk, prophylactic insertion of implantable cardioverter defibrillators (ICDs) reduces mortality. Current approaches to identify patients at risk for arrhythmia are, however, of low sensitivity and specificity, which results in a low rate of appropriate ICD therapy. Here, we develop a personalized approach to assess SCD risk in post-infarction patients based on cardiac imaging and computational modelling. We construct personalized three-dimensional computer models of post-infarction hearts from patients’ clinical magnetic resonance imaging data and assess the propensity of each model to develop arrhythmia. In a proof-of-concept retrospective study, the virtual heart test significantly outperformed several existing clinical metrics in predicting future arrhythmic events. The robust and non-invasive personalized virtual heart risk assessment may have the potential to prevent SCD and avoid unnecessary ICD implantations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416
Nonparametric statistics for non-statisticians: a step-by-step approach
(2010) · Choice Reviews Online · doi:10.5860/choice.47-3859 · Cited by 1,021
Nonparametric Statistics for Non‐Statisticians: A Step‐by‐Step Approach
Corder, G. W., & Foreman, D. I. (2009) · Wiley eBooks · doi:10.1002/9781118165881 · Cited by 954
Chi-squared and Fisher-Irwin tests of two-by-two tables with small sample recommendations
Campbell, I. (2007) · Statistics in Medicine · doi:10.1002/sim.2832 · Cited by 912 · cited 1×
“The characteristics were compared between the two groups using two-tailed rank-sum test 60 or Fisher’s exact test 61 , as appropriate.”
MethodSchmidt, A., Azevedo, C. F., Cheng, A., Gupta, S. N., Bluemke, D. A., Foo, T. K., Gerstenblith, G., Weiss, R. G., Marbán, E., Tomaselli, G. F., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.653568 · Cited by 823
Self-citationIncreased left ventricular mass and hypertrophy are associated with increased risk for sudden death
Haider, A. W., Larson, M. G., Benjamin, E. J., & Levy, D. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00407-0 · Cited by 800
Fishman, G. I., Chugh, S. S., DiMarco, J. P., Albert, C. M., Anderson, M. E., Bonow, R. O., Buxton, A. E., Chen, P.-S., Estes, M., Jouven, X., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976092 · Cited by 614
Self-citationWu, K. C., Weiss, R. G., Thiemann, D. R., Kitagawa, K., Schmidt, A., Dalal, D., Lai, S., Bluemke, D. A., Gerstenblith, G., Marbán, E., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.03.018 · Cited by 598
Self-citationWhat Causes Sudden Death in Heart Failure?
Tomaselli, G. F., & Zipes, D. P. (2004) · Circulation Research · doi:10.1161/01.res.0000145047.14691.db · Cited by 566
Bayer, J. D., Blake, R. C., Plank, G., & Trayanova, N. A. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0593-5 · Cited by 557
Self-citationStecker, E. C., Vickers, C., Waltz, J., Socoteanu, C., John, B. T., Mariani, R., McAnulty, J. H., Gunson, K., Jui, J., & Chugh, S. S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.045 · Cited by 542
Roes, S. D., Borleffs, C. J. W., van der Geest, R. J., Westenberg, J. J. M., Marsan, N. A., Kaandorp, T. A. M., Reiber, J. H. C., Zeppenfeld, K., Lamb, H. J., de Roos, A., et al. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.826529 · Cited by 461
Roberts, D. E., Hersh, L. T., & Scher, A. M. (1979) · Circulation Research · doi:10.1161/01.res.44.5.701 · Cited by 437
Shape-based interpolation of multidimensional objects
Raya, S. P., & Udupa, J. K. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52980 · Cited by 435
Multivariable Analysis: A Primer for Readers of Medical Research
Katz, M. H. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-8-200304150-00012 · Cited by 403
Gorgels, A. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00191-x · Cited by 350
Mortality and Cost Associated With Cardiovascular Implantable Electronic Device Infections
Sohail, M. R. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.441 · Cited by 350
Solvers for the cardiac bidomain equations
Vigmond, E. J., Weber dos Santos, R., Prassl, A. J., Deo, M., & Plank, G. (2008) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.07.012 · Cited by 344
Klem, I., Weinsaft, J. W., Bahnson, T. D., Hegland, D., Kim, H. W., Hayes, B., Parker, M. A., Judd, R. M., & Kim, R. J. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.070 · Cited by 331
Computational tools for modeling electrical activity in cardiac tissue
Vigmond, E. J., Hughes, M., Plank, G., & Leon, L. J. (2003) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2003.09.017 · Cited by 316
Reynolds, M. R., Cohen, D. J., Kugelmass, A. D., Brown, P. P., Becker, E. R., Culler, S. D., & Simon, A. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.049 · Cited by 291
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Pu, J., & Boyden, P. A. (1997) · Circulation Research · doi:10.1161/01.res.81.1.110 · Cited by 222
A guide to modelling cardiac electrical activity in anatomically detailed ventricles
Clayton, R. H., & Panfilov, A. V. (2008) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.07.004 · Cited by 220
Electrical conductivity values used with the bidomain model of cardiac tissue
Roth, B. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.563303 · Cited by 208
Buxton, A. E., Lee, K. L., Hafley, G. E., Wyse, D. G., Fisher, J. D., Lehmann, M. H., Pires, L. A., Gold, M. R., Packer, D. L., Josephson, M. E., et al. (2002) · Circulation · doi:10.1161/01.cir.0000037224.15873.83 · Cited by 204
Risk set sampling in epidemiologic cohort studies
Goldstein, L., & Langholz, B. (1996) · Statistical Science · doi:10.1214/ss/1032209663 · Cited by 197
Laminar Arrangement of Ventricular Myocytes Influences Electrical Behavior of the Heart
Hooks, D. A., Trew, M. L., Caldwell, B. J., Sands, G. B., LeGrice, I. J., & Smaill, B. H. (2007) · Circulation Research · doi:10.1161/circresaha.107.161075 · Cited by 187
Camelliti, P. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2004.01.027 · Cited by 174
Poelzing, S., Akar, F. G., Baron, E., & Rosenbaum, D. S. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00987.2003 · Cited by 163
Plank, G., Zhou, L., Greenstein, J. L., Cortassa, S. C., Winslow, R. L., O'Rourke, B. P., & Trayanova, N. A. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0112 · Cited by 149
Self-citationModels of cardiac electromechanics based on individual hearts imaging data
Gurev, V., Lee, T. L.-T., Constantino, J. L., Arevalo, H., & Trayanova, N. A. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0235-5 · Cited by 148
Self-citationFeasibility of image-based simulation to estimate ablation target in human ventricular arrhythmia
Ashikaga, H., Arevalo, H., Vadakkumpadan, F., Blake, R., Bayer, J. D., Nazarian, S., Zviman, M. M., Tandri, H. S., Berger, R. D., Calkins, H. G., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.04.015 · Cited by 145
Self-citationRodríguez, B., Li, L., Eason, J. C., Efimov, I. R., & Trayanova, N. A. (2005) · Circulation Research · doi:10.1161/01.res.0000174429.00987.17 · Cited by 135
Self-citationAutomatically Generated, Anatomically Accurate Meshes for Cardiac Electrophysiology Problems
Prassl, A. J., Kickinger, F., Ahammer, H., Grau, V., Schneider, J. E., Hofer, E., Vigmond, E. J., Trayanova, N. A., & Plank, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2014243 · Cited by 126
Self-citationCabo, C., & Boyden, P. A. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00512.2002 · Cited by 112
Wu, K. C., Gerstenblith, G., Güallar, E., Marine, J. E., Dalal, D., Cheng, A., Marbán, E., Lima, J. A. C., Tomaselli, G. F., & Weiss, R. G. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.111.968024 · Cited by 102
Self-citationTachycardia in Post-Infarction Hearts: Insights from 3D Image-Based Ventricular Models
Arevalo, H., Plank, G., Helm, P. A., Halperin, H. R., & Trayanova, N. A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068872 · Cited by 100
Self-citationNot Everyone With an Ejection Fraction ≤30% Should Receive an ICD
Buxton, A. E. (2005) · Circulation · doi:10.1161/01.cir.0000165057.88551.2c · Cited by 80
The Role of Photon Scattering in Optical Signal Distortion during Arrhythmia and Defibrillation
Bishop, M. J., Rodríguez, B., Qu, F., Efimov, I. R., Gavaghan, D. J., & Trayanova, N. A. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.110981 · Cited by 74
Self-citationDeng, D., Arevalo, H., Pashakhanloo, F., Prakosa, A., Ashikaga, H., McVeigh, E. R., Halperin, H. R., & Trayanova, N. A. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00282 · Cited by 60
Self-citationDecker, K. F., & Rudy, Y. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00362.2010 · Cited by 54
Modeling the Role of the Coronary Vasculature During External Field Stimulation
Bishop, M. J., Boyle, P. M., Plank, G., Welsh, D. G., & Vigmond, E. J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051227 · Cited by 49
Cheng, A., Dalal, D., Butcher, B., Norgard, S., Zhang, Y., Dickfeld, T. M., ELDADAH, Z. A., Ellenbogen, K. A., Güallar, E., & Tomaselli, G. F. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.000083 · Cited by 47
Rantner, L. J., Arevalo, H., Constantino, J. L., Efimov, I. R., Plank, G., & Trayanova, N. A. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.229088 · Cited by 36
Self-citationModeling of heterogeneous electrophysiology in the human heart with respect to ECG genesis
Weiss, D. L., Seemann, G., Keller, D. U. J., Farina, D., Sachse, F. B., & Dössel, O. (2007) · Computers in cardiology · doi:10.1109/cic.2007.4745418 · Cited by 21
Piccini, J. P., Hafley, G. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., Buxton, A. E., & for the MUSTT Investigators (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01469.x · Cited by 19
Bayer, J. D., Beaumont, J., & Król, A. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5624-z · Cited by 18
Programmed Ventricular Stimulation: Not Dead
Buxton, A. E. (2014) · Circulation · doi:10.1161/circulationaha.113.007747 · Cited by 11
Implantable Cardioverter-Defibrillators
Lampert, R. J., & Goldberger, Z. D. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-424-7_6 · Cited by 6
Josephson, M. E. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12412 · Cited by 6
Cited by
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero, J., Margara, F., Marciniak, M., Rodero, C., Loncaric, F., Feng, Y., Gilbert, A., Fernandes, J. F., Bukhari, H. A., Wajdan, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa159 · Cited by 932
Computational models in cardiology
Niederer, S. A., Lumens, J., & Trayanova, N. A. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0104-y · Cited by 434
Self-citationHalliday, B. P., Baksi, A. J., Gulati, A., Ali, A., Newsome, S., Izgi, C., Arzanauskaite, M., Lota, A., Tayal, U., Vassiliou, V. S., et al. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.07.015 · Cited by 331
Computationally guided personalized targeted ablation of persistent atrial fibrillation
Boyle, P. M., Zghaib, T., Zahid, S., Ali, R. L., Deng, D., Franceschi, W. H., Hakim, J. B., Murphy, M. J., Prakosa, A., Zimmerman, S. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0437-9 · Cited by 312
Self-citationThe openCARP simulation environment for cardiac electrophysiology
Plank, G., Loewe, A., Neic, A., Augustin, C., Huang, Y.-L., Gsell, M. A. F., Karabelas, E., Nothstein, M., Prassl, A. J., Sánchez, J., et al. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106223 · Cited by 264
Metadata
- Authors
- Arevalo, H. J., Vadakkumpadan, F., Guallar, E., Jebb, A., Malamas, P., Wu, K. C., & Trayanova, N. A.
- Venue
- Nature Communications
- Published
- 2016-05-10
- Volume
- 7
- Issue
- 1
- Pages
- 11437-11437
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2367512715
- Cited by
- 465
- References
- 57
- FWCI
- 33.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.