The DOI matches its Crossref record; 139 of the 139 references it cites were found in a registry or an index.
Microfluidics: reframing biological enquiry
Open accessAbstract
The underlying physical properties of microfluidic tools have led to new biological insights through the development of microsystems that can manipulate, mimic and measure biology at a resolution that has not been possible with macroscale tools. Microsystems readily handle sub-microlitre volumes, precisely route predictable laminar fluid flows and match both perturbations and measurements to the length scales and timescales of biological systems. The advent of fabrication techniques that do not require highly specialized engineering facilities is fuelling the broad dissemination of microfluidic systems and their adaptation to specific biological questions. We describe how our understanding of molecular and cell biology is being and will continue to be advanced by precision microfluidic approaches and posit that microfluidic tools — in conjunction with advanced imaging, bioinformatics and molecular biology approaches — will transform biology into a precision science.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mizgerd, J. P., Kubo, H., Kutkoski, G. J., Bhagwan, S. D., Scharffetter-Kochanek, K., Beaudet, A. L., & Doerschuk, C. M. (1997) · The Journal of Experimental Medicine · doi:10.1084/jem.186.8.1357 · Cited by 7,306
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Cell mechanics and the cytoskeleton
Fletcher, D. A., & Mullins, R. D. (2010) · Nature · doi:10.1038/nature08908 · Cited by 2,989
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Causal Protein-Signaling Networks Derived from Multiparameter Single-Cell Data
Sachs, K., Perez, O., Pe'er, D., Lauffenburger, D. A., & Nolan, G. P. (2005) · Science · doi:10.1126/science.1105809 · Cited by 1,708
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Nishida, N., Yano, H., Nishida, T., Kamura, T., & Kojiro, M. (2006) · Vascular Health and Risk Management · doi:10.2147/vhrm.2006.2.3.213 · Cited by 1,434
CEL-seq: single-cell RNA-seq by multiplexed linear amplification
Hashimshony, T., Wagner, F., Sher, N., & Yanai, I. (2012) · Cell Reports · doi:10.1016/j.celrep.2012.08.003 · Cited by 1,231
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Genome-Wide Detection of Single-Nucleotide and Copy-Number Variations of a Single Human Cell
Zong, C., Lu, S., Chapman, A. R., & Xie, X. S. (2012) · Science · doi:10.1126/science.1229164 · Cited by 1,154
Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Characterization of human embryonic stem cell lines by the International Stem Cell Initiative
Initiative, T. I. S. C. (2007) · Nature Biotechnology · doi:10.1038/nbt1318 · Cited by 1,073
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Robust Growth of Escherichia coli
Wang, P., Robert, L., Pelletier, J., Dang, W. L., Taddei, F., Wright, A., & Jun, S. (2010) · Current Biology · doi:10.1016/j.cub.2010.04.045 · Cited by 1,014
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Physical plasticity of the nucleus in stem cell differentiation
Pajerowski, J. D., Dahl, K. N., Zhong, F. L., Sammak, P. J., & Discher, D. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702576104 · Cited by 833
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Hydrodynamic stretching of single cells for large population mechanical phenotyping
Gossett, D. R., Tse, H. T. K., Lee, S. A., Ying, Y., Lindgren, A. G., Yang, O. O., Rao, J., Clark, A. T., & Di Carlo, D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200107109 · Cited by 775
Micro- and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices
Kirby, B. J. (2010) · Cited by 753
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Hjertén, S. (1967) · Chromatographic Reviews · doi:10.1016/0009-5907(67)80003-6 · Cited by 728
Dynamic single cell culture array
Carlo, D. D., Wu, L. Y., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b605937f · Cited by 707
Quantitative assessment of single-cell RNA-sequencing methods
Wu, A. R., Neff, N. F., Kalisky, T., Dalerba, P., Treutlein, B., Rothenberg, M. E., Mburu, F. M., Mantalas, G. L., Sim, S., Clarke, M. F., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2694 · Cited by 696
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Regulation of cytoplasmic mRNA decay
Schoenberg, D. R., & Maquat, L. E. (2012) · Nature Reviews Genetics · doi:10.1038/nrg3160 · Cited by 656
The Onset of Turbulence in Pipe Flow
Avila, K., Moxey, D., de Lozar, A., Avila, M., Barkley, D., & Hof, B. (2011) · Science · doi:10.1126/science.1203223 · Cited by 639
Mathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589
A systems approach to measuring the binding energy landscapes of transcription factors.
Maerkl, S. J., & Quake, S. R. (2007) · Science · doi:10.1126/science.1131007 · Cited by 584
Chowdhury, F., Na, S., Li, D., Poh, Y.-C., Tanaka, T. S., Wang, F., & Wang, N. (2010) · Nature Materials · doi:10.1038/nmat2563 · Cited by 575
A microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534
Patterning cells and their environments using multiple laminar fluid flows in capillary networks
Takayama, S., McDonald, J. C., Ostuni, E., Liang, M. N., Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5545 · Cited by 528
Hansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.262485199 · Cited by 517
Genome-wide Single-Cell Analysis of Recombination Activity and De Novo Mutation Rates in Human Sperm
Wang, J., Fan, H. C., Behr, B., & Quake, S. R. (2012) · Cell · doi:10.1016/j.cell.2012.06.030 · Cited by 511
Biomimetic model to reconstitute angiogenic sprouting morphogenesis in vitro
Nguyen, D.-H. T., Stapleton, S. C., Yang, M. T., Cha, S. S., Choi, C. K., Galie, P. A., & Chen, C. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221526110 · Cited by 493
Micro- and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices
Kirby, B. J. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9780511760723 · Cited by 486
Stiffness Gradients Mimicking In Vivo Tissue Variation Regulate Mesenchymal Stem Cell Fate
Tse, J. R., & Engler, A. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0015978 · Cited by 455
Electronic Separation of Biological Cells by Volume
Fulwyler, M. J. (1965) · Science · doi:10.1126/science.150.3698.910 · Cited by 454
Ma, C., Fan, R., Ahmad, H., Shi, Q., Comin-Anduix, B., Chodon, T., Koya, R. C., Liu, C.-C., Kwong, G. A., Radu, C. G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2375 · Cited by 441
High-throughput microfluidic single-cell RT-qPCR
White, A. K., VanInsberghe, M., Petriv, O. I., Hamidi, M., Sikorski, D., Marra, M. A., Piret, J., Aparicio, S., & Hansen, C. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019446108 · Cited by 440
Universal process-inert encoding architecture for polymer microparticles
Lee, J., Bisso, P. W., Srinivas, R. L., Kim, J. J., Swiston, A. J., & Doyle, P. S. (2014) · Nature Materials · doi:10.1038/nmat3938 · Cited by 418
Hughes, A. J., Spelke, D. P., Xu, Z., Kang, C.-C., Schaffer, D. V., & Herr, A. E. (2014) · Nature Methods · doi:10.1038/nmeth.2992 · Cited by 415
Self-citationCell Growth and Size Homeostasis in Proliferating Animal Cells
Tzur, A., Kafri, R., LeBleu, V. S., Lahav, G., & Kirschner, M. W. (2009) · Science · doi:10.1126/science.1174294 · Cited by 402
Wang, B. L., Ghaderi, A., Zhou, H., Agresti, J., Weitz, D. A., Fink, G. R., & Stephanopoulos, G. (2014) · Nature Biotechnology · doi:10.1038/nbt.2857 · Cited by 330
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Esch, M. B., King, T. L., & Shuler, M. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124629 · Cited by 328
Microfluidic system for formation of PC-3 prostate cancer co-culture spheroids
Hsiao, A. Y., Torisawa, Y.-S., Tung, Y.-C., Sud, S., Taichman, R. S., Pienta, K. J., & Takayama, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.047 · Cited by 323
Single-cell proteomic chip for profiling intracellular signaling pathways in single tumor cells
Shi, Q., Qin, L., Wei, W., Geng, F., Fan, R., Shik Shin, Y., Guo, D., Hood, L., Mischel, P. S., & Heath, J. R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1110865109 · Cited by 318
The promise of single-cell sequencing
Eberwine, J., Sul, J.-Y., Bartfai, T., & Kim, J. (2014) · Nature Methods · doi:10.1038/nmeth.2769 · Cited by 304
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Analyzing cell mechanics in hematologic diseases with microfluidic biophysical flow cytometry
Rosenbluth, M. J., Lam, W. A., & Fletcher, D. A. (2008) · Lab on a Chip · doi:10.1039/b802931h · Cited by 297
High-resolution dose–response screening using droplet-based microfluidics
Miller, O. J., Harrak, A. E., Mangeat, T., Baret, J.-C., Frenz, L., Debs, B. E., Mayot, E., Samuels, M. L., Rooney, E. K., Dieu, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113324109 · Cited by 286
Nanoliter Reactors Improve Multiple Displacement Amplification of Genomes from Single Cells
Marcy, Y., Ishoey, T., Lasken, R. S., Stockwell, T. B., Walenz, B. P., Halpern, A. L., Beeson, K. Y., Goldberg, S. M. D., & Quake, S. R. (2007) · PLoS Genetics · doi:10.1371/journal.pgen.0030155 · Cited by 286
Emrich, C. A., Tian, H., Medintz, I. L., & Mathies, R. A. (2002) · Analytical Chemistry · doi:10.1021/ac020236g · Cited by 284
Li, J. J., Bickel, P. J., & Biggin, M. D. (2014) · PeerJ · doi:10.7717/peerj.270 · Cited by 279
Microfluidic single-cell whole-transcriptome sequencing
Streets, A. M., Zhang, X., Cao, C., Pang, Y., Wu, X., Xiong, L., Yang, L., Fu, Y., Zhao, L., Tang, F., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1402030111 · Cited by 276
Functional single-cell hybridoma screening using droplet-based microfluidics
Debs, B. E., Utharala, R., Balyasnikova, I. V., Griffiths, A. D., & Merten, C. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204514109 · Cited by 276
Highly multiplexed and strand-specific single-cell RNA 5′ end sequencing
Islam, S., Kjällquist, U., Moliner, A., Zajac, P., Fan, J.-B., Lönnerberg, P., & Linnarsson, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.022 · Cited by 272
Quantitative Diagnosis of Malignant Pleural Effusions by Single-Cell Mechanophenotyping
Tse, H. T. K., Gossett, D. R., Moon, Y. S., Masaeli, M., Sohsman, M., Ying, Y., Mislick, K., Adams, R. P., Rao, J., & Di Carlo, D. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006559 · Cited by 266
Programmable on-chip DNA compartments as artificial cells
Karzbrun, E., Tayar, A. M., Noireaux, V., & Bar-Ziv, R. H. (2014) · Science · doi:10.1126/science.1255550 · Cited by 264
Simpson, P. C., Roach, D., Woolley, A. T., Thorsen, T., Johnston, R., Sensabaugh, G. F., & Mathies, R. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.5.2256 · Cited by 234
Sung, J. H., Esch, M. B., Prot, J.-M., Long, C. J., Smith, A., Hickman, J. J., & Shuler, M. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41017j · Cited by 233
Liver-cell patterning lab chip: mimicking the morphology of liver lobule tissue
Ho, C.-T., Lin, R.-Z., Chen, R.-J., Chin, C.-K., Gong, S.-E., Chang, H.-Y., Peng, H.-L., Hsu, L., Yew, T.-R., Chang, S.-F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50402f · Cited by 230
Lee, S. S., Vizcarra, I. A., Huberts, D. H. E. W., Lee, L. P., & Heinemann, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113505109 · Cited by 217
Microfluidics separation reveals the stem-cell–like deformability of tumor-initiating cells
Zhang, W., Kai, K., Choi, D. S., Iwamoto, T., Nguyen, Y. H., Wong, H., Landis, M. D., Ueno, N. T., Chang, J., & Qin, L. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209893109 · Cited by 208
Flow cytometry for high-throughput, high-content screening
Edwards, B. S., Oprea, T., Prossnitz, E. R., & Sklar, L. A. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.06.007 · Cited by 206
Haessler, U., Pisano, M., Wu, M., & Swartz, M. A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014920108 · Cited by 206
Approaches to the study of the cell secretome
Hathout, Y. (2007) · Expert Review of Proteomics · doi:10.1586/14789450.4.2.239 · Cited by 203
Mitochondrial Network Size Scaling in Budding Yeast
Rafelski, S. M., Viana, M. P., Zhang, Y., Chan, Y.-H. M., Thorn, K. S., Yam, P., Fung, J. C., Li, H., Costa, L. D. F., & Marshall, W. F. (2012) · Science · doi:10.1126/science.1225720 · Cited by 197
An open letter to our readers on the use of antibodies
Saper, C. B. (2005) · Journal of Comparative Neurology · doi:10.1002/cne.20839 · Cited by 187
Fordyce, P. M., Gerber, D., Tran, D., Zheng, J., Li, H., DeRisi, J. L., & Quake, S. R. (2010) · Nature Biotechnology · doi:10.1038/nbt.1675 · Cited by 184
Microfluidics-Based Assessment of Cell Deformability
Adamo, A., Sharei, A., Adamo, L., Lee, B., Mao, S., & Jensen, K. F. (2012) · Analytical Chemistry · doi:10.1021/ac300264v · Cited by 183
Kuwano, Y., Spelten, O., Zhang, H., Ley, K., & Zarbock, A. (2010) · Blood · doi:10.1182/blood-2010-01-266122 · Cited by 170
The Potential Impact of Droplet Microfluidics in Biology
Schneider, T., Kreutz, J., & Chiu, D. T. (2013) · Analytical Chemistry · doi:10.1021/ac400257c · Cited by 166
Programmable microfluidic synthesis of spectrally encoded microspheres.
Gerver, R., Gómez-Sjöberg, R., Baxter, B., Thorn, K., Fordyce, P., Diaz-Botia, C., Helms, B., & Derisi, J. (2012) · Lab on a Chip · doi:10.1039/c2lc40699c · Cited by 166
Neveu, G., Barouch‐Bentov, R., Ziv-Av, A., Gerber, D., Jacob, Y., & Einav, S. (2012) · PLoS Pathogens · doi:10.1371/journal.ppat.1002845 · Cited by 161
Observation of spatial propagation of amyloid assembly from single nuclei
Knowles, T. P. J., White, D. A., Abate, A. R., Agresti, J. J., Cohen, S. I. A., Sperling, R. A., De Genst, E. J., Dobson, C. M., & Weitz, D. A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105555108 · Cited by 158
(2013) · Nature Methods · doi:10.1038/nmeth.2801 · Cited by 145
External and internal constraints on eukaryotic chemotaxis
Fuller, D., Chen, W., Adler, M., Groisman, A., Levine, H., Rappel, W., & Loomis, W. F. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911178107 · Cited by 144
Pinched-flow hydrodynamic stretching of single-cells
Dudani, J. S., Gossett, D. R., Tse, H. T. K., & Carlo, D. D. (2013) · Lab on a Chip · doi:10.1039/c3lc50649e · Cited by 142
Hansen, A. S., & O’Shea, E. K. (2013) · Molecular Systems Biology · doi:10.1038/msb.2013.56 · Cited by 142
Desai, B. K., Dixon, K., Farrant, E., Feng, Q., Gibson, K. R., van Hoorn, W. P., Mills, J. E. J., Morgan, T., Parry, D. M., Ramjee, M. K., et al. (2013) · Journal of Medicinal Chemistry · doi:10.1021/jm400099d · Cited by 142
Droplet-based microfluidic platforms for single T cell secretion analysis of IL-10 cytokine
Konry, T., Dominguez‐Villar, M., Baecher‐Allan, C., Hafler, D. A., & Yarmush, M. L. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.006 · Cited by 134
Neeves, K. B., Illing, D. A. R., & Diamond, S. L. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2009.12.4275 · Cited by 134
Sung, J. H., Srinivasan, B., Esch, M. B., McLamb, W., Bernabini, C., Shuler, M. L., & Hickman, J. J. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214529397 · Cited by 133
Structure of the transcriptional network controlling white‐opaque switching in C andida albicans
Hernday, A. D., Lohse, M. B., Fordyce, P. M., Nobile, C. J., DeRisi, J. L., & Johnson, A. D. (2013) · Molecular Microbiology · doi:10.1111/mmi.12329 · Cited by 131
Massively parallel measurements of molecular interaction kinetics on a microfluidic platform
Geertz, M., Shore, D., & Maerkl, S. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1206011109 · Cited by 126
Probabilistic error correction for RNA sequencing
Le, H.-S., Schulz, M. H., McCauley, B. S., Hinman, V. F., & Bar‐Joseph, Z. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt215 · Cited by 125
Tracking lineages of single cells in lines using a microfluidic device
Rowat, A. C., Bird, J., Agresti, J. J., Rando, O. J., & Weitz, D. A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903163106 · Cited by 121
Molecular phenotyping of aging in single yeast cells using a novel microfluidic device
Xie, Z., Zhang, Y., Zou, K., Brandman, O., Luo, C., Ouyang, Q., & Li, H. (2012) · Aging Cell · doi:10.1111/j.1474-9726.2012.00821.x · Cited by 121
Migration of cells in a social context
Vedel, S., Tay, S., Johnston, D. M., Bruus, H., & Quake, S. R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204291110 · Cited by 116
A microfluidic device and computational platform for high-throughput live imaging of gene expression
Busch, W., Moore, B. T., Martsberger, B., Mace, D., Twigg, R. W., Jung, J. W., Pruteanu-Malinici, I., Kennedy, S. J., Fricke, G. K., Clark, R. L., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2185 · Cited by 115
Microfluidic analysis of red blood cell deformability
Guo, Q., Duffy, S. P., Matthews, K., Santoso, A. T., Scott, M. D., & Ma, H. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.03.038 · Cited by 114
Sun, J., Masterman-Smith, M. D., Graham, N. A., Jiao, J., Mottahedeh, J., Laks, D. R., Ohashi, M., DeJesus, J., Kamei, K., Lee, K., et al. (2010) · Cancer Research · doi:10.1158/0008-5472.can-10-0076 · Cited by 111
Biased migration of confined neutrophil-like cells in asymmetric hydraulic environments
Prentice-Mott, H. V., Chang, C.-H., Mahadevan, L., Mitchison, T. J., Irimia, D., & Shah, J. V. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317441110 · Cited by 106
High-Throughput Microfluidic Single-Cell Digital Polymerase Chain Reaction
White, A. K., Heyries, K. A., Doolin, C., VanInsberghe, M. A., & Hansen, C. L. (2013) · Analytical Chemistry · doi:10.1021/ac400896j · Cited by 104
Fish and Chips: a microfluidic perfusion platform for monitoring zebrafish development
Choudhury, D., van Noort, D., Iliescu, C., Zheng, B., Poon, K., Korzh, S., Korzh, V. P., & Yu, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20351g · Cited by 102
Single-Cell Western Blotting after Whole-Cell Imaging to Assess Cancer Chemotherapeutic Response
Kang, C., Lin, J.-M. G., Xu, Z., Kumar, S., & Herr, A. E. (2014) · Analytical Chemistry · doi:10.1021/ac502932t · Cited by 99
Self-citationMicrofluidic Cardiac Cell Culture Model (μCCCM)
Giridharan, G. A., Nguyen, M.-D., Estrada, R., Parichehreh, V., Hamid, T., Ismahil, M. A., Prabhu, S. D., & Sethu, P. (2010) · Analytical Chemistry · doi:10.1021/ac1012893 · Cited by 92
Automated protein-DNA interaction screening of Drosophila regulatory elements
Hens, K., Feuz, J., Isakova, A., Hafner, A., Massouras, A., Bryois, J., Callaerts, P., Celniker, S., & Deplancke, B. (2011) · Nature Methods · doi:10.1038/nmeth.1763 · Cited by 85
1,2,3,4-Tetrahydroisoquinolinyl sulfamic acids as phosphatase PTP1B inhibitors
Klopfenstein, S. R., Evdokimov, A. G., Colson, A., Fairweather, N. T., Neuman, J. J., Maier, M. B., Gray, J. L., Gerwe, G. S., Stake, G. E., Howard, B. W., et al. (2006) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2005.12.051 · Cited by 84
Wilson, K. A., Das, M., Wahl, K. J., Colton, R. J., & Hickman, J. J. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011042 · Cited by 82
Sen, A., Rothenberg, M. E., Mukherjee, G., Feng, N., Tomer Kalisky, C., Nair, N., Johnstone, I. M., Clarke, M. F., & Greenberg, H. B. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1212188109 · Cited by 80
Su, X., Young, E. W. K., Underkofler, H. A. S., Kamp, T. J., January, C. T., & Beebe, D. J. (2010) · SLAS DISCOVERY · doi:10.1177/1087057110386218 · Cited by 76
Yu, J., Zhou, J., Sutherland, A., Wei, W., Shin, Y. S., Xue, M., & Heath, J. R. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020323 · Cited by 74
Exploring Living Multicellular Organisms, Organs, and Tissues Using Microfluidic Systems
Sivagnanam, V., & Gijs, M. A. M. (2013) · Chemical Reviews · doi:10.1021/cr200432q · Cited by 73
Fordyce, P. M., Pincus, D., Kimmig, P., Nelson, C. S., El‐Samad, H., Walter, P., & DeRisi, J. L. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1212457109 · Cited by 73
Systematic reconstruction of RNA functional motifs with high-throughput microfluidics
Martin, L., Meier, M., Lyons, S. M., Sit, R. V., Marzluff, W. F., Quake, S. R., & Chang, H. Y. (2012) · Nature Methods · doi:10.1038/nmeth.2225 · Cited by 72
Martin, J. G., Gupta, M., Xu, Y., Akella, S., Liu, J., Dordick, J. S., & Linhardt, R. J. (2009) · Journal of the American Chemical Society · doi:10.1021/ja903038d · Cited by 69
Çiftlik, A. T., Lehr, H., & Gijs, M. A. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211273110 · Cited by 66
Modeling of cancer metastasis and drug resistance via biomimetic nano-cilia and microfluidics
Kuo, C.-T., Chiang, C.-L., Chang, C.-H., Liu, H.-K., Huang, G.-S., Huang, R. Y.-J., Lee, H., Huang, C.-S., & Wo, A. M. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.008 · Cited by 65
Uckun, F. M., Ma, H., Zhang, J., Özer, Z., Dovat, S., Mao, C., Ishkhanian, R., Goodman, P. A., & Qazi, S. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209828109 · Cited by 64
Microfluidic Investigation of BDNF‐Enhanced Neural Stem Cell Chemotaxis in CXCL12 Gradients
Xu, H., & Heilshorn, S. C. (2012) · Small · doi:10.1002/smll.201202208 · Cited by 60
Protein Signaling Networks from Single Cell Fluctuations and Information Theory Profiling
Shin, Y. S., Remacle, F., Fan, R., Hwang, K., Wei, W., Ahmad, H. M. N., Levine, R. D., & Heath, J. R. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.04.025 · Cited by 58
Christophis, C., Taubert, I., Meseck, G. R., Schubert, M., Grunze, M., Ho, A. D., & Rosenhahn, A. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.05.045 · Cited by 55
Kravchenko‐Balasha, N., Wang, J., Remacle, F., Levine, R. D., & Heath, J. R. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1404462111 · Cited by 54
Huberts, D. H. E. W., Lee, S. S., González, J., Janssens, G. E., Vizcarra, I. A., & Heinemann, M. (2013) · Nature Protocols · doi:10.1038/nprot.2013.060 · Cited by 43
Shuga, J., Zeng, Y., Novak, R., Lan, Q., Tang, X., Rothman, N., Vermeulen, R. C. H., Li, L., Hubbard, A., Zhang, L., et al. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt613 · Cited by 38
Kim, M. S., Kwon, S., Kim, T., Lee, E. S., & Park, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.040 · Cited by 35
Optimization of 3-D organotypic primary colonic cultures for organ-on-chip applications
Ahmad, A. A., Wang, Y., Gracz, A. D., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2014) · Journal of Biological Engineering · doi:10.1186/1754-1611-8-9 · Cited by 35
A yeast one‐hybrid and microfluidics‐based pipeline to map mammalian gene regulatory networks
Gubelmann, C., Waszak, S. M., Isakova, A., Holcombe, W., Hens, K., Hafner, A., Feuz, J., Raghav, S. K., Simicevic, J., & Deplancke, B. (2013) · Molecular Systems Biology · doi:10.1038/msb.2013.38 · Cited by 34
Lin, L., Ma, C., Wei, B., Aziz, N., Rajalingam, R., Yusung, S. A., Erlich, H. A., Trachtenberg, E., Targan, S. R., McGovern, D. P. B., et al. (2014) · The Journal of Immunology · doi:10.4049/jimmunol.1400093 · Cited by 33
Morel, M., Shynkar, V. V., Galas, J.-C., Dupin, I., Bouzigues, C., Studer, V., & Dahan, M. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.08.040 · Cited by 31
Rauch, J. N., Nie, J., Buchholz, T. J., Gestwicki, J. E., & Kennedy, R. T. (2013) · Analytical Chemistry · doi:10.1021/ac4023082 · Cited by 30
Hughes, A. J., Tentori, A. M., & Herr, A. E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3064292 · Cited by 24
Self-citationDamped oscillations in the adaptive response of the iron homeostasis network of E. coli
Amir, A., Meshner, S., Beatus, T., & Stavans, J. (2010) · Molecular Microbiology · doi:10.1111/j.1365-2958.2010.07111.x · Cited by 22
Shamloo, A., Manchandia, M., Ferreira, M. M., Mani, M., Nguyen, C. D., Jahn, T., Weinberg, K. I., & Heilshorn, S. C. (2013) · Integrative Biology · doi:10.1039/c3ib40025e · Cited by 17
Microfluidic interrogation and mathematical modeling of multi-regime calcium signaling dynamics
Jović, A., Wade, S. M., Neubig, R. R., Linderman, J. J., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40032h · Cited by 12
In vivo measurement of signaling cascade dynamics
McClean, M. N., Hersen, P., & Ramanathan, S. (2009) · Cell Cycle · doi:10.4161/cc.8.3.7450 · Cited by 8
Research works printed but not linked: 9
- Lanier, L. L. Just the FACS. J. Immunol. 193, 2043–2044 (2014). · doi:10.4049/jimmunol.1401725
- Dovichi, N. J. & Zhang, J. Z. How capillary electrophoresis sequenced the human genome. Angew. Chem. Int. Ed. Engl. 39, 4463–4468 (2000). · doi:10.1002/1521-3773(20001215)39:24<4463::aid-anie4463>3.0.co;2-8
- Akagi, J. et al. Integrated chip-based physiometer for automated fish embryo toxicity biotests in pharmaceutical screening and ecotoxicology. Cytometry A 85, 537–547 (2014). · doi:10.1002/cyto.a.22464
- Akagi, J. et al. Opensource lab-on-a-chip physiometer for accelerated zebrafish embryo biotests. Curr. Protoc. Cytom. 67, 9.44.1–9.44.16 (2014). · doi:10.1002/0471142956.cy0944s67
- Zheng, C. et al. Fish in chips: an automated microfluidic device to study drug dynamics in vivo using zebrafish embryos. Chem. Commun. 50, 981–984 (2014). · doi:10.1039/c3cc47285j
- Chiang, Y.-Y. & West, J. Ultrafast cell switching for recording cell surface transitions: new insights into epidermal growth factor receptor signalling. Lab Chip 13, 1031–1034 (2013). · doi:10.1039/c3lc41297k
- Fazelinia, H., Xu, M., Cheng, H. & Roder, H. Ultrafast hydrogen exchange reveals specific structural events during the initial stages of folding of cytochrome c. J. Am. Chem. Soc. 136, 733–740 (2014). Ultra-fast microfluidic mixing for hydrogen–deuterium exchange enabled researchers to determine that decreased chain dimensions during the early stages of cytochrome c folding are due to specific α-helix interactions and not a general hydrophobic collapse of the protein. · doi:10.1021/ja410437d
- Granieri, L., Baret, J. C., Griffiths, A. D. & Merten, C. A. High-throughput screening of enzymes by retroviral display using droplet-based microfluidics. Chem. Biol. 17, 229–235 (2010). · doi:10.1016/j.chembiol.2010.02.011
- Kazuo, H. & Ryutaro, M. A pneumatically-actuated three-way microvalve fabricated with polydimethylsiloxane using the membrane transfer technique. J. Micromech. Microeng. 10, 415 (2000). · doi:10.1088/0960-1317/10/3/317
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Comparative Analysis of Droplet-Based Ultra-High-Throughput Single-Cell RNA-Seq Systems
Zhang, X., Li, T., Liu, F., Chen, Y., Yao, J., Li, Z., Huang, Y., & Wang, J. (2019) · Molecular Cell · doi:10.1016/j.molcel.2018.10.020 · Cited by 383
Clogging of microfluidic systems
Dressaire, E., & Sauret, A. (2017) · Soft Matter · doi:10.1039/c6sm01879c · Cited by 370
The revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
Metadata
- Authors
- Duncombe, T. A., Tentori, A. M., & Herr, A. E.
- Venue
- Nature Reviews Molecular Cell Biology
- Published
- 2015-08-21
- Volume
- 16
- Issue
- 9
- Pages
- 554-567
- ISSN
- 1471-0072 (ISSN-L)
- 1471-0080
- OpenAlex
- W1179069838
- Cited by
- 345
- References
- 139
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.