Sensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Open accessThe DOI matches its Crossref record; 58 of the 59 references it cites were found in a registry or an index.
Abstract
Conventional leg prostheses do not convey sensory information about motion or interaction with the ground to above-knee amputees, thereby reducing confidence and walking speed in the users that is associated with high mental and physical fatigue 1-4. The lack of physiological feedback from the remaining extremity to the brain also contributes to the generation of phantom limb pain from the missing leg 5,6. To determine whether neural sensory feedback restoration addresses these issues, we conducted a study with two transfemoral amputees, implanted with four intraneural stimulation electrodes 7 in the remaining tibial nerve (ClinicalTrials.gov identifier NCT03350061). Participants were evaluated while using a neuroprosthetic device consisting of a prosthetic leg equipped with foot and knee sensors. These sensors drive neural stimulation, which elicits sensations of knee motion and the sole of the foot touching the ground. We found that walking speed and self-reported confidence increased while mental and physical fatigue decreased for both participants during neural sensory feedback compared to the no stimulation trials. Furthermore, participants exhibited reduced phantom limb pain with neural sensory feedback. The results from these proof-of-concept cases provide the rationale for larger population studies investigating the clinical utility of neuroprostheses that restore sensory feedback.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Stimulation holds tremendous promise for prosthetic information feedback[86,515] and rehabilitation.[329,516,517]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [517]
In the citing paper
“Another clinical trial with two transfemoral amputees has shown that sensory feedback via TIME electrodes ameliorates walking speed, and decreases oxygen and energy consumption, which produces a lower cardiorespiratory burden [103].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [103]
In the citing paper
“While cuffs have been the predominant choice for widespread clinical stimulation applications, newer ultraflexible devices such as the TIME are seeing great success in humans (D'Anna et al., 2019; Petrini et al., 2019).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Petrini et al., 2019
In the citing paper
“Together with a growing interest in the translation of these technologies into human clinical use (Wendelken et al., 2017; D'Anna et al., 2019; Petrini et al., 2019), FBR has become a dominant problem that needs to be actively addressed at the implant design stage.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Petrini et al., 2019
Citations
Cites
Melzack, R., & Wall, P. D. (1965) · Science · doi:10.1126/science.150.3699.971 · Cited by 11,090
Updating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919
(2005) · Cited by 5,977
Farrar, J. T., Young, J. P., LaMoreaux, L., Werth, J. L., & Poole, M. R. (2001) · Pain · doi:10.1016/s0304-3959(01)00349-9 · Cited by 5,808
The Activities-specific Balance Confidence (ABC) Scale
Powell, L. E., & Myers, A. M. (1995) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/50a.1.m28 · Cited by 2,869
A critical review of visual analogue scales in the measurement of clinical phenomena
Wewers, M. E., & Lowe, N. K. (1990) · Research in Nursing & Health · doi:10.1002/nur.4770130405 · Cited by 2,580
Steffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
Development and validation of the Neuropathic Pain Symptom Inventory
Bouhassira, D., Attal, N., Fermanian, J., Alchaar, H., Gautron, M., Masquelier, E., Rostaing, S., Lanteri-Minet, M., Collin, E., Grisart, J., et al. (2004) · Pain · doi:10.1016/j.pain.2003.12.024 · Cited by 1,329
A Review of the Integrate-and-fire Neuron Model: I. Homogeneous Synaptic Input
Burkitt, A. N. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0068-6 · Cited by 1,208
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationPhantom limb pain: a case of maladaptive CNS plasticity?
Flor, H., Nikolajsen, L., & Staehelin Jensen, T. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1991 · Cited by 905
Energy cost of walking of amputees: the influence of level of amputation.
Waters, R. L., Perry, J., Antonelli, D. J., & Hislop, H. J. (1976) · PubMed · Cited by 873
Energy cost of walking of amputees: the influence of level of amputation
Waters, R., Perry, J., Antonelli, D., & Hislop, H. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00007 · Cited by 842
Real-time neuroimaging and cognitive monitoring using wearable dry EEG
Mullen, T. R., Kothe, C. A. E., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Jung, T.-P., & Cauwenberghs, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481482 · Cited by 795
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Reshaping the Village Test for investigating service brand attachment
Mzahi, C. (2014) · Qualitative Market Research: An International Journal · doi:10.1108/qmr-12-2012-0057 · Cited by 742
Wickens, C., Kramer, A., Vanasse, L., & Donchin, E. (1983) · Science · doi:10.1126/science.6879207 · Cited by 724
EFNS guidelines on neurostimulation therapy for neuropathic pain
Cruccu, G., Aziz, T. Z., Garcia‐Larrea, L., Hansson, P., Jensen, T. S., Lefaucheur, J. ‐., Simpson, B. A., & Taylor, R. S. (2007) · European Journal of Neurology · doi:10.1111/j.1468-1331.2007.01916.x · Cited by 690
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Self-citationAdjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputees
Nolan, L., Wit, A., Dudziñski, K., Lees, A., Lake, M., & Wychowañski, M. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00066-8 · Cited by 454
Distribution and behaviour of glabrous cutaneous receptors in the human foot sole
Kennedy, P. M., & Inglis, J. T. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.013087 · Cited by 438
Energy expenditure and biomechanical characteristics of lower limb amputee gait:
Schmalz, T., Blumentritt, S., & Jarasch, R. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00008-5 · Cited by 428
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationSemi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364
Miller, W. C., Deathe, A. B., Speechley, M., & Koval, J. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25079 · Cited by 360
Phantom pain is associated with preserved structure and function in the former hand area
Makin, T. R., Scholz, J., Filippini, N., Henderson Slater, D., Tracey, I., & Johansen-Berg, H. (2013) · Nature Communications · doi:10.1038/ncomms2571 · Cited by 348
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 345
Self-citationThe Event-Related Brain Potential as an Index of Display-Monitoring Workload
Isreal, J. B., Wickens, C. D., Chesney, G. L., & Donchin, E. (1980) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872088002200210 · Cited by 309
A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302
Assessing Cognitive Distraction in the Automobile
Strayer, D. L., Turrill, J., Cooper, J. M., Coleman, J. R., Medeiros-Ward, N., & Biondi, F. (2015) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720815575149 · Cited by 235
Proprioception from a neurally controlled lower-extremity prosthesis
Clites, T. R., Carty, M. J., Ullauri, J. B., Carney, M. E., Mooney, L. M., Duval, J.-F., Srinivasan, S. S., & Herr, H. M. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8373 · Cited by 233
Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Self-citationEffect of speed on the energy cost of walking in unilateral traumatic lower limb amputees
Genin, J. J., Bastien, G. J., Franck, B., Detrembleur, C., & Willems, P. A. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0764-0 · Cited by 168
Charkhkar, H., Shell, C. E., Marasco, P. D., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac964 · Cited by 131
Hafner, B. J., & Smith, D. G. (2009) · PubMed · Cited by 129
Why traumatic leg amputees are at increased risk for cardiovascular diseases
Naschitz, J. E., & Lenger, R. (2008) · QJM · doi:10.1093/qjmed/hcm131 · Cited by 129
Gait efficiency using the C-Leg
Orendurff, M. S., Segal, A. D., Klute, G. K., McDowell, M. L., Pecoraro, J. A., & Czerniecki, J. M. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0095 · Cited by 128
Zink, R., Hunyadi, B., Huffel, S. V., & Vos, M. D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046017 · Cited by 128
Detrembleur, C., Vanmarsenille, J.-M., Cuyper, F. D., & Dierick, F. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.005 · Cited by 124
Increased cardiovascular disease mortality rates in traumatic lower limb amputees
Modan, M., Peles, E., Halkin, H., Nitzan, H., AZARIA, M., Gitel, S. N., Dolfin, D., & Modan, B. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00601-8 · Cited by 122
GAILEY, R. S., McFarland, L. V., Cooper, R. A., Czerniecki, J. M., Gambel, J. M., Hubbard, S., Maynard, C. C., Smith, D. G., Raya, M. A., & Reiber, G. E. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.04.0039 · Cited by 111
Crea, S., Edin, B. B., Knaepen, K., Meeusen, R., & Vitiello, N. (2017) · Physical Therapy · doi:10.2522/ptj.20150441 · Cited by 110
High-Frequency Electrical Nerve Block for Postamputation Pain: A Pilot Study
Soin, A., Shah, N. S., & Fang, Z.-P. (2015) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12266 · Cited by 104
Leg Prosthesis With Somatosensory Feedback Reduces Phantom Limb Pain and Increases Functionality
Dietrich, C., Nehrdich, S., Seifert, S., Blume, K. R., Miltner, W. H. R., Hofmann, G. O., & Weiss, T. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00270 · Cited by 98
P300 Event-Related Potential as an Indicator of Inattentional Deafness?
Giraudet, L., St-Louis, M.-È., Scannella, S., & Causse, M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118556 · Cited by 93
Traballesi, M., Porcacchia, P., Averna, T., & Brunelli, S. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.01.006 · Cited by 93
Bellmann, M., Schmalz, T., Ludwigs, E., & Blumentritt, S. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.10.017 · Cited by 91
Can vibratory feedback be used to improve postural stability in persons with transtibial limb loss?
Rusaw, D., Hagberg, K., Nolan, L., & Ramstrand, N. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.05.0088 · Cited by 87
Raspopovic, S., Petrini, F. M., Zelechowski, M., & Valle, G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2600560 · Cited by 84
Self-citationThe Event Related Cortical Potential as an Index of Task Workload
Wickens, C. D., Isreal, J. B., & Donchin, E. (1977) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/107118137702100404 · Cited by 78
Deeny, S. P., Chicoine, C. L., Hargrove, L. J., Parrish, T. B., & Jayaraman, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112091 · Cited by 72
Does Having a Computerized Prosthetic Knee Influence Cognitive Performance During Amputee Walking?
Williams, R. M., Turner, A. P., Orendurff, M. S., Segal, A. D., Klute, G. K., Pecoraro, J. A., & Czerniecki, J. M. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.03.006 · Cited by 72
Development and Psychometric Properties of the Ambulatory Self-Confidence Questionnaire
Asano, M., Miller, W. C., & Eng, J. J. (2007) · Gerontology · doi:10.1159/000104830 · Cited by 70
A distributed architecture for activating the peripheral nervous system
Andreu, D., Guiraud, D., & Souquet, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026001 · Cited by 69
Self-citationAfferent Sensory Feedback for Lower Extremity Prosthesis
CLIPPINGER, F. W., SEABER, A. V., MCELHANEY, J. H., HARRELSON, J. M., & MAXWELL, G. M. (1982) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198209000-00031 · Cited by 54
de Castro, M. P., Soares, D. P., Mendes, E., & Machado, L. J. (2014) · PM&R · doi:10.1016/j.pmrj.2014.01.019 · Cited by 46
Intuitive Control of a Powered Prosthetic Leg During Ambulation: A Randomized Clinical Trial
Hargrove, L. J., Young, A., & Simon, A. M. (2016) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2016.03.403 · Cited by 31
A new psychometric questionnaire for reporting of somatosensory percepts
Kim, L. H., McLeod, R. S., & Kiss, Z. H. T. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa966a · Cited by 27
Research works printed but not linked: 1
- Melzack, R. & Casey, K. L. Sensory, motivational, and central control determinants of pain: a new conceptual model. In Proc. of the First International Symposium on the Skin Senses (ed. Kenshalo, D. R.) 423–436, (Charles C Thomas Publisher, 1968).
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Combined with potential improvements in the implantation procedure, flexible penetrating nerve implants such as these hold great potential for long-term therapeutic applications and translation into clinical use, as highlighted by the several recent uses of TIMEs in human patients (D’Anna et al., 2019; Petrini et al.,…”
BackgroundInfluentialSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationFleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
“A case study has shown promising preliminary results in improving gait stability, energetic efficiency, and cognitive load evenwith a passive prosthesis [131].”
Background
Metadata
- Authors
- Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., Lechler, K., Lesic, A., Mazic, S., Mijović, B., Guiraud, D., Stieglitz, T., Alexandersson, A., Micera, S., & Raspopovic, S.
- Affiliations
- ETH Zurich (CH)
- Scuola Superiore Sant'Anna (IT)
- mBrainTrain LLC (Serbia) (RS)
- University of Freiburg (DE)
- Institut Mihajlo Pupin (RS)
- Institut national de recherche en sciences et technologies du numérique (FR)
- Össur (Iceland) (IS)
- University of Belgrade (RS)
- ORCID
- Venue
- Nature Medicine
- Published
- 2019-09
- Volume
- 25
- Issue
- 9
- Pages
- 1356-1363
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W2972339980
- Cited by
- 269
- References
- 59
- Citations by year
- 2026: 25 · 2025: 39 · 2024: 38 · 2023: 45 · 2022: 40 · 2021: 57 · 2020: 24 · 2019: 1
- FWCI
- 10.77
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repository for Publications and Research Data (ETH Zurich) (publishedVersion, other-oa)
- HAL (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- ETH Zürich Research Collection
- Funders
- National Science Foundation
- European Commission (759998, 754497)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (176006)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- transfemoral amputation, phantom limb pain, intraneural stimulation, tibial nerve, neural prostheses, prosthetic leg, walking speed, walking confidence, fatigue
- MeSH terms
- Walking Speed, Adult, Amputees, Artificial Limbs, Biomechanical Phenomena, Humans, Knee, Male, Middle Aged, Phantom Limb, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.