Tutorial: a computational framework for the design and optimization of peripheral neural interfaces
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Peripheral neural interfaces have been successfully used in the recent past to restore sensory-motor functions in disabled subjects and for the neuromodulation of the autonomic nervous system. The optimization of these neural interfaces is crucial for ethical, clinical and economic reasons. In particular, hybrid models (HMs) constitute an effective framework to simulate direct nerve stimulation and optimize virtually every aspect of implantable electrode design: the type of electrode (for example, intrafascicular versus extrafascicular), their insertion position and the used stimulation routines. They are based on the combined use of finite element methods (to calculate the voltage distribution inside the nerve due to the electrical stimulation) and computational frameworks such as NEURON (https://neuron.yale.edu/neuron/) to determine the effects of the electric field generated on the neural structures. They have already provided useful results for different applications, but the overall usability of this powerful approach is still limited by the intrinsic complexity of the procedure. Here, we illustrate a general, modular and expandable framework for the application of HMs to peripheral neural interfaces, in which the correct degree of approximation required to answer different kinds of research questions can be readily determined and implemented. The HM workflow is divided into the following tasks: identify and characterize the fiber subpopulations inside the fascicles of a given nerve section, determine different degrees of approximation for fascicular geometries, locate the fibers inside these geometries and parametrize electrode geometries and the geometry of the nerve–electrode interface. These tasks are examined in turn, and solutions to the most relevant issues regarding their implementation are described. Finally, some examples related to the simulation of common peripheral neural interfaces are provided. Neural interfaces with implantable electrodes are used to modulate and restore function to the peripheral nervous system. Hybrid modeling described in this protocol is used to optimize each aspect of the implantable electrode design and operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“In the framework of quasi-static electrical stimulation 7,31 , a biological tissue can be characterized by means of rank-2 conductivity tensors.”
BackgroundFUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“PNS is intrinsically linked with the concepts of selectivity and invasiveness 91 .”
BackgroundSelf-citationAnalysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681 · cited 3×
“(1) Generation of nerve section geometry: choice between two alternative solutions, namely (1a) nerve sections obtained via manual segmentation of histological sections can be simplified into circular or elliptical fascicle geometries or (1b) ex novo generation of nerve section (R, nerve section radius; N, number of f…”
BackgroundA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 12×
“21 , which highlights the very different electric fi eld shapes generate by a FINE and a TIME.”
MethodInfluentialA Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435 · cited 1×
“5 The possibility of linking the model to higher neural pathway processing models to simulate the modulating action of higher centers (for example, spinal ganglia 10 ).”
BackgroundSelf-citationTHE INTRANEURAL TOPOGRAPHY OF THE RADIAL, MEDIAN AND ULNAR NERVES
SUNDERLAND, S. (1945) · Brain · doi:10.1093/brain/68.4.243 · Cited by 426 · cited 2×
“The locations of functional groups with de fi nite motor or sensory targets in humans have been studied for decades, providing a useful body of information, especially for large nerves such as the median 33,35,37,39,40,44,45 and sciatic 36,38,41,46 – 48 nerves.”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Bioelectronic medicines: a research roadmap
Birmingham, K., Gradinaru, V., Anikeeva, P., Grill, W. M., Pikov, V., McLaughlin, B., Pasricha, P., Weber, D., Ludwig, K., & Famm, K. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4351 · Cited by 322
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“We identify low maximum gain and high linearity as two desirable characteristics of a recruitment curve, which facilitates controllability and simpli fi es the design of the relative controller 105,106 .”
BackgroundSafety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Rattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Self-citationSchiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148
Fascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 1×
“The perineurial sheath is assumed to have a thickness of 0.03 times the fascicle effective diameter 32 (the diameter of an equivalent circle).”
BackgroundInfluentialSelectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121
Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111 · cited 1×
“Recruitment is directly linked to motion or sensation, and thresholds for palpable muscle contraction are generally set to a recruitment of 10% of the fi bers in a population 103 .”
BackgroundA three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82 · cited 2×
“In case of extraneural FINE-like electrodes (for example, FINE and SC-FINE 51 ) as well as TIME-like electrodes (for example, TIME and SELINE 52 ), the implantation of neural interfaces (see Section 3) affects the intraneural topography both in the location of fascicles in the nerve cross-section…”
MethodSelf-citationCurrent approaches to model extracellular electrical neural microstimulation
Joucla, S., Glière, A., & Yvert, B. (2014) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2014.00013 · Cited by 78 · cited 2×
“95,97,98 .”
MethodFascicular topography of the human median nerve for neuroprosthetic surgery
Delgado-Martínez, I., Badia, J., Pascual-Font, A., Rodríguez-Baeza, A., & Navarro, X. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00286 · Cited by 77 · cited 2×
“A rough description of peripheral nerve branching can be found in classical neuroanatomy textbooks such as ref, 34 : such indications must be supported by quantitative descriptions of the most frequent anatomical variants for the nerve under study 35,36 .”
BackgroundSpatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73 · cited 1×
“Moreover, our HM has also been used to optimize intraneural stimulation for vision restoration 28 and hand function restoration (Badi-Dubois, under preparation).”
MethodSelf-citationImproved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
Quantification of human upper extremity nerves and fascicular anatomy
Brill, N. A., & Tyler, D. J. (2017) · Muscle & Nerve · doi:10.1002/mus.25534 · Cited by 64
Raspopovic, S., Capogrosso, M., Badia, J., Navarro, X., & Micera, S. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189021 · Cited by 63 · cited 5×
“25 , we refer here to Fig.”
BackgroundMethodInfluentialSelf-citationMultielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62 · cited 2×
“It is well known that different fi ber types are characterized by different typical diameters 77 , which relate to the conduction velocity 78 and fi ber excitability 79,80 .”
BackgroundHallin, R. G. (1990) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.9.736 · Cited by 62
AxonSeg: open source software for axon and myelin segmentation and morphometric analysis
Zaimi, A., Duval, T., Gasecka, A., Côté, D., Stikov, N., & Cohen-Adad, J. (2016) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2016.00037 · Cited by 57
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · cited 2×
“4, block 2a) represent the fraction of active fi bers for a given magnitude of the stimulation 102 and are used mainly with three concurrent issues in mind: threshold identi fi cation, recruitment steepness and recruitment order.”
Background
Cited by
Vallone, F., Ottaviani, M. M., Dedola, F., Cutrone, A., Romeni, S., Panarese, A. M., Bernini, F., Cracchiolo, M., Strauss, I., Gabisonia, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d42 · Cited by 35
“To understand the distribution of the electrical field potential within a nerve, we employed the hybrid modeling framework previously described by us [49–51].”
InfluentialSelf-citationA machine learning framework to optimize optic nerve electrical stimulation for vision restoration
Romeni, S., Zoccolan, D., & Micera, S. (2021) · Patterns · doi:10.1016/j.patter.2021.100286 · Cited by 17
“The natural choice here would be to insert a hybrid model 35 to compute the response of the optic nerve fibers to electrical stimulation via detailed finite element modeling and neural computation simulation.”
Self-citationA computational model to design wide field-of-view optic nerve neuroprostheses
Micera, S., Romeni, S., De Luca, D., Pierantoni, L., Toni, L., Marino, G., & Moccia, S. (2023) · doi:10.21203/rs.3.rs-3218482/v1 · Cited by 2
Self-citation
Metadata
- Authors
- Romeni, S., Valle, G., Mazzoni, A., & Micera, S.
- Venue
- Nature Protocols
- Published
- 2020-09-28
- Volume
- 15
- Issue
- 10
- Pages
- 3129-3153
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W3091627004
- Cited by
- 76
- References
- 31
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.