CoChat

User adaptation in Myoelectric Man-Machine Interfaces

Open access
Hahne, Janne M., Markovic, Marko, Farina, Dario · 2017 · Scientific Reports
Cited by 121

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

State of the art clinical hand prostheses are controlled in a simple and limited way that allows the activation of one function at a time. More advanced laboratory approaches, based on machine learning, offer a significant increase in functionality, but their clinical impact is limited, mainly due to lack of reliability. In this study, we analyse two conceptually different machine learning approaches, focusing on their robustness and performance in a closed loop application. A classification (finite number of classes) and a regression (continuous mapping) based projection of EMG into external commands were applied while artificially introducing non-stationarities in the EMG signals. When tested on ten able-bodied individuals and one transradial amputee, the two methods were similarly influenced by non-stationarities when tested offline. However, in online tests, where the user could adapt his muscle activation patterns to the changed conditions, the regression-based approach was significantly less influenced by the changes in signal features than the classification approach. This observation demonstrates, on the one hand, the importance of online tests with users in the loop for assessing the performance of myocontrol approaches. On the other hand, it also demonstrates that regression allows for a better user correction of control commands than classification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-017-04255-x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 31

  1. Sherman, E. D. A Russian Bioelectric-Controlled Prosthesis. Can. Med. Assoc. J. 91, 1268–1270 (1964).
  2. Muzumdar, A. Powered upper limb prostheses: control, implementation and clinical application. (Springer, 2004). · DOI
  3. Belter, J. T., Segil, J. L., Dollar, A. M. & Weir, R. F. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review. J. Rehabil. Res. Dev. 50, 599–618 (2013). · DOI · Paper page
  4. Hahne, J. M., Graimann, B. & Muller, K. R. Spatial filtering for robust myoelectric control. IEEE Trans. Biomed. Eng. 59, 1436–1443 (2012). · DOI
  5. Parker, P., Englehart, K. & Hudgins, B. Myoelectric signal processing for control of powered limb prostheses. J. Electromyogr. Kinesiol. 16, 541–8 (2006). · DOI · Paper page
  6. Scheme, E. & Englehart, K. Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use. J. Rehabil. Res. Dev. 48, 643–659 (2011). · DOI · Paper page
  7. Peerdeman, B. et al. Myoelectric forearm prostheses: State of the art from a user-centered perspective. J. Rehabil. Res. Dev. 48, 719 (2011). · DOI · Paper page
  8. Castellini, C. & van der Smagt, P. Surface {EMG} in advanced hand prosthetics. Biol. Cybern. 100, 35–47 (2009). · DOI · Paper page
  9. Young, A., Smith, L., Rouse, E. & Hargrove, L. Classification of Simultaneous Movements using Surface {EMG} Pattern Recognition. Biomed. Eng. IEEE Trans. 60, 1250–1258 (2013). · DOI · Paper page
  10. Jiang, N., Englehart, K. B. & Parker, P. A. Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal. IEEE Trans. Biomed. Eng. 56, 1070–1080 (2009). · DOI · Paper page
  11. Nielsen, J. L. et al. Simultaneous and Proportional Force Estimation for Multifunction Myoelectric Prostheses Using Mirrored Bilateral Training. IEEE Trans. Biomed. Eng. 58, 681–688 (2011). · DOI · Paper page
  12. Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B. & Parker, P. A. Support vector regression for improved real-time, simultaneous myoelectric control. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 1198–1209 (2014). · DOI · Paper page
  13. Muceli, S. & Farina, D. Simultaneous and Proportional Estimation of Hand Kinematics From EMG During Mirrored Movements at Multiple Degrees-of-Freedom. IEEE Trans. Neural Syst. Rehabil. Eng. 20, 371–378 (2012). · DOI · Paper page
  14. Hahne, J. M. et al. Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 269–279 (2014). · DOI · Paper page
  15. Hwang, H.-J., Hahne, J. M. & Müller, K.-R. Channel selection for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom. J. Neural Eng. 11, 56008 (2014). · DOI
  16. Ison, M., Vujaklija, I., Whitsell, B., Farina, D. & Artemiadis, P. High-Density Electromyography and Motor Skill Learning for Robust Long-Term Control of a 7-DoF Robot Arm. IEEE Trans. Neural Syst. Rehabil. Eng. 24, 424–433 (2016). · DOI
  17. Jiang, N., Dosen, S., Muller, K. R. & Farina, D. Myoelectric control of artificial limbsis there a need to change focus? [In the Spotlight]. IEEE Signal Processing Magazine 29, 148–152 (2012).
  18. Almström, C., Herberts, P. & Körner, L. Experience with swedish multifunctional prosthetic hands controlled by pattern recognition of multiple myoelectric signals. Int. Orthop. 5, 15–21 (1981). · DOI
  19. Lorrain, T., Jiang, N. & Farina, D. Influence of the training set on the accuracy of surface EMG classification in dynamic contractions for the control of multifunction prostheses. J. Neuroeng. Rehabil. 8, 25 (2011). · DOI · Paper page
  20. Farina, D. et al. The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: Emerging Avenues and Challenges. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 797–809 (2014). · DOI · Paper page
  21. Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K. & Stavdahl, Ø. Resolving the Limb Position Effect in Myoelectric Pattern Recognition. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 644–651 (2011). · DOI · Paper page
  22. Vidovic, M. M.-C. et al. Improving the Robustness of Myoelectric Pattern Recognition for Upper Limb Prostheses by Covariate Shift Adaptation. IEEE Trans. Neural Syst. Rehabil. Eng. 24, 961–970 (2016). · DOI · Paper page
  23. He, J. et al. User adaptation in long-term, open-loop myoelectric training: implications for EMG pattern recognition in prosthesis control. J. Neural Eng. 12, 46005 (2015). · DOI · Paper page
  24. Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B. & Farina, D. Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control? IEEE Trans. Neural Syst. Rehabil. Eng. 22, 549–558 (2014). · DOI · Paper page
  25. Bishop, C. M. Pattern Recognition and Machine Learning. (Springer, 2007).
  26. Hahne, J., Dahne, S., Hwang, H.-J., Muller, K.-R. & Parra, L. Concurrent Adaptation of Human and Machine Improves Simultaneous and Proportional Myoelectric Control. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 644–651 (2015).
  27. Hahne, J. M., Farina, D., Jiang, N. & Liebetanz, D. A Novel Percutaneous Electrode Implant for Improving Robustness in Advanced Myoelectric Control. Front. Neurosci. 10, (2016). · DOI
  28. Williams, M. R. & Kirsch, R. F. Evaluation of Head Orientation and Neck Muscle EMG Signals as Command Inputs to a Human–Computer Interface for Individuals With High Tetraplegia. IEEE Trans. Neural Syst. Rehabil. Eng. 16, 485–496 (2008). · DOI · Paper page
  29. Scheme, E. J. & Englehart, K. B. Validation of a selective ensemble-based classification scheme for myoelectric control using a three-dimensional fitts’ law test. IEEE Trans. Neural Syst. Rehabil. Eng. 21, 616–623 (2013). · DOI · Paper page
  30. Sturma, A., Herceg, M., Bischof, B., Fialka-Moser, V. & Aszmann, O. C. In Replace, Repair, Restore, Relieve – Bridging Clinical and and Engineering Solutions in Neurorehabilitation. 169–177, doi:10.1007/978-3-319-08072-7_33 (Springer International Publishing, 2014). · DOI
  31. Scheme, E. J., Englehart, K. B. & Hudgins, B. S. Selective classification for improved robustness of myoelectric control under nonideal conditions. IEEE Trans. Biomed. Eng. 58, 1698–1705 (2011). · DOI · Paper page

Cited by

See all 121

Metadata

Authors
Hahne, J. M., Markovic, M., & Farina, D.
Venue
Scientific Reports
Published
2017-06-30
Volume
7
Issue
1
Pages
4437-4437
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2712146091
Cited by
121
References
8
FWCI
6.63
Type
journal article
Language
en
Open access
gold
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.