Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 143 of the 144 references it cites were found in a registry or an index; 36 of the 128 sources its claims cite were checked for support.
Abstract
Deep learning (DL) has the potential to transform medical diagnostics. However, the diagnostic accuracy of DL is uncertain. Our aim was to evaluate the diagnostic accuracy of DL algorithms to identify pathology in medical imaging. Searches were conducted in Medline and EMBASE up to January 2020. We identified 11,921 studies, of which 503 were included in the systematic review. Eighty-two studies in ophthalmology, 82 in breast disease and 115 in respiratory disease were included for meta-analysis. Two hundred twenty-four studies in other specialities were included for qualitative review. Peer-reviewed studies that reported on the diagnostic accuracy of DL algorithms to identify pathology using medical imaging were included. Primary outcomes were measures of diagnostic accuracy, study design and reporting standards in the literature. Estimates were pooled using random-effects meta-analysis. In ophthalmology, AUC’s ranged between 0.933 and 1 for diagnosing diabetic retinopathy, age-related macular degeneration and glaucoma on retinal fundus photographs and optical coherence tomography. In respiratory imaging, AUC’s ranged between 0.864 and 0.937 for diagnosing lung nodules or lung cancer on chest X-ray or CT scan. For breast imaging, AUC’s ranged between 0.868 and 0.909 for diagnosing breast cancer on mammogram, ultrasound, MRI and digital breast tomosynthesis. Heterogeneity was high between studies and extensive variation in methodology, terminology and outcome measures was noted. This can lead to an overestimation of the diagnostic accuracy of DL algorithms on medical imaging. There is an immediate need for the development of artificial intelligence-specific EQUATOR guidelines, particularly STARD, in order to provide guidance around key issues in this field.
Overview
CoChat Summary
TL;DR
This systematic review and meta-analysis found that deep learning algorithms generally achieve high diagnostic accuracy in medical imaging, with pooled AUCs ranging from 0.864 to 1 across ophthalmology, respiratory, and breast imaging. However, high heterogeneity and widespread methodological/reporting deficiencies mean these estimates are uncertain and may overestimate true accuracy.
Key findings
- Across 503 included studies, pooled AUCs were high: ophthalmology 0.933–1 for diabetic retinopathy, age-related macular degeneration, and glaucoma on retinal fundus photographs or OCT; respiratory 0.864–0.937 for lung nodules or lung cancer on chest X-ray or CT; breast 0.868–0.909 for breast cancer on mammogram, ultrasound, MRI, or digital breast tomosynthesis.
- Heterogeneity was high between studies, with many I² values above 75% and often near 99% (e.g., I² 99.9% for diabetic retinopathy on retinal fundus photographs; 99.6% for tuberculosis on X-ray).
- QUADAS-2 assessment classified a majority as high or unclear risk: patient selection 59/82 (72%) ophthalmic, 89/115 (77%) respiratory, 62/82 (76%) breast; flow/timing 66/82 (80%), 93/115 (81%), 70/82 (85%); reference standard applicability concerns 60/82 (73%), 104/115 (90%), 78/82 (95%).
- Only 8 ophthalmology, 10 respiratory, and 6 breast studies mentioned STARD-2015 adherence or included a STARD flow diagram; no studies provided a prespecified sample size calculation, and few used prospective data (8 ophthalmology, 2 respiratory, 0 breast) or external validation (29 ophthalmology, 13 respiratory, 8 breast).
Methods
- Systematic review and meta-analysis conducted per PRISMA-DTA; Medline and EMBASE searched up to 3 January 2020; peer-reviewed English studies reporting diagnostic accuracy of deep learning algorithms on medical imaging in human populations were included.
- Searches identified 11,921 abstracts; 503 studies fulfilled inclusion criteria for the systematic review, with meta-analysis in ophthalmology (82 studies), respiratory medicine (115), and breast cancer (82), plus qualitative synthesis of 224 studies in other specialities.
- Data were extracted independently by two investigators; risk of bias/applicability assessed with QUADAS-2 by three investigators; bivariate models and DerSimonian and Laird random-effects meta-analysis were used, with I² for heterogeneity and SROC where raw data were available; analyses used Stata version 15; PROSPERO CRD42020167503.
Limitations
- The paper states that many included studies had methodological deficiencies or poor reporting, so the pooled diagnostic performance estimates are uncertain and may represent an overestimation of true accuracy; it also states that no quality assessment for transparency of reporting was conducted because STARD-2015 was not designed for deep learning studies.
- The paper states that classical statistical comparison between imaging modalities was not possible, that each modality could not be separated into subsets to break down heterogeneity, and that findings may not generalise to other forms of medical imaging or AI studies.
- Evident from the text: heterogeneity was high across studies (I² often >75%, frequently >99%), most studies were at high or unclear risk of bias on QUADAS-2, and few studies were prospective, externally validated, or had prespecified sample size calculations.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
11 Valid · 3 Not valid · 32 Not checked · 165 Own results and interpretations
None of the sources cited for this claim have been checked yet.
In the paper
“With increasing demands upon existing radiologists (especially in low-to-middle-income countries)6–8, there is a growing need for diagnosis automation.”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Introduction
What the sources say
- Could not verifycites [6] Wahl B Cossy-Gantner A Germann S Schwalbe NR Artificial intelligence (AI) and global health: how can AI contribute to health in resource-poor settings? BMJ Glob. Health 2018 3 e000798 e000798 10.1136/bmjgh-2018-000798 30233828 PMC6135465 sourceExperimental — accuracy not yet measured
The citation is attached to the claim about increasing demands on radiologists, especially in low- and middle-income countries. The passages in “Unanswered questions and remaining challenges” discuss AI-assisted diagnosis in resource-poor settings, but do not address radiologists’ workloads. Searches for radiologists and healthcare-worker shortages found no passage establishing that point. (LLM, conf=0.72)
- Could not verifycites [7] Zhang L Wang H Li Q Zhao M-H Zhan Q-M Big data and medical research in China BMJ 2018 360 j5910 10.1136/bmj.j5910 29437562 PMC5797979 sourceExperimental — accuracy not yet measured
The citation is attached to the claim about increasing demands on radiologists, especially in low-to-middle-income countries. The “Medical Research in China” passage discusses machine learning replacing some radiologists’ work in China, but does not address radiologist workload or demand, or the specified country group (page not available). Searches for radiologist demand, workload, and shortages found no passage addressing that point. (LLM, conf=0.76)
- Not checked yetcites [8] Nakajima Y Yamada K Imamura K Kobayashi K Radiologist supply and workload: international comparison Radiat. Med. 2008 26 455 465 10.1007/s11604-008-0259-2 18975046 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Twenty-five studies17,28,29,35,37,39,40,44–61 compared algorithm performance against healthcare professionals.”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Ophthalmology imaging
What the sources say
- Supportedcites [17] Gulshan V Performance of a deep-learning algorithm vs manual grading for detecting diabetic retinopathy in India JAMA Ophthalmol 2019 137 987 993 10.1001/jamaophthalmol.2019.2004 31194246 PMC6567842 source
The Discussion reports that this study compared an automated algorithm with retinal specialists and trained graders in a prospective clinical setting. It supports citing this paper as one of the studies making that comparison; the count of 25 describes the citing paper’s group of studies, not a finding attributed to this individual source. (LLM, conf=0.93)
- Not checked yetcites [28] Gulshan V Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs JAMA 2016 316 2402 2410 10.1001/jama.2016.17216 27898976 source
- Supportedcites [29] Hwang DK Artificial intelligence-based decision-making for age-related macular degeneration Theranostics 2019 9 232 245 10.7150/thno.28447 30662564 PMC6332801 source
The source is one of the studies cited for the comparison, not the source of the citing authors’ count of 25. In “Verification of final AI models and comparison between reviewers and AI,” it describes comparing its AI models with retinal specialists and medical students; the comparison section reports their relative performance. (LLM, conf=0.93)
- Not checked yetcites [35] Liu S A deep learning-based algorithm identifies glaucomatous discs using monoscopic fundus photographs Ophthalmol. Glaucoma 2018 1 15 22 10.1016/j.ogla.2018.04.002 32672627 source
- Supportedcites [37] Phene S Deep learning and glaucoma specialists: the relative importance of optic disc features to predict glaucoma referral in fundus photographs Ophthalmology 2019 126 1627 1639 10.1016/j.ophtha.2019.07.024 31561879 source
The Results report that 10 eye-care providers graded the same images used to evaluate the algorithm, and their performance was plotted for comparison. This paper therefore qualifies as one of the studies identified in the citing sentence; the total of 25 is the citing paper’s count, not a finding attributed to this individual study. (LLM, conf=0.93)
- Supportedcites [39] Raumviboonsuk P Deep learning versus human graders for classifying diabetic retinopathy severity in a nationwide screening program npj Digital Med. 2019 2 25 10.1038/s41746-019-0099-8 PMC6550283 31304372 source
The Abstract describes a diabetic-retinopathy study that compared a deep learning algorithm with human graders, so this paper qualifies as one of the cited ophthalmology studies. The count of 25 is the citing document’s count across its listed studies, not a count attributed to this individual source. (LLM, conf=0.92)
- Not checked yetcites [40] Sayres R Using a deep learning algorithm and integrated gradients explanation to assist grading for diabetic retinopathy Ophthalmology 2019 126 552 564 10.1016/j.ophtha.2018.11.016 30553900 source
- Not checked yetcites [44] Van Grinsven MJ van Ginneken B Hoyng CB Theelen T Sánchez CI Fast convolutional neural network training using selective data sampling: application to hemorrhage detection in color fundus images IEEE Trans. Med. Imaging 2016 35 1273 1284 10.1109/TMI.2016.2526689 26886969 source
- Supportedcites [45] Rogers TW Evaluation of an AI system for the automated detection of glaucoma from stereoscopic optic disc photographs: the European Optic Disc Assessment Study Eye 2019 33 1791 1797 10.1038/s41433-019-0510-3 31267086 PMC7002599 source
The Methods state that this study compared the Pegasus AI system’s performance with that of ophthalmologists and optometrists. The Results report that comparison, so this paper is one of the studies identified by the citing sentence; the sentence does not attribute the total of 25 studies to this paper alone. (LLM, conf=0.94)
- Not checked yetcites [46] Al-Aswad LA Evaluation of a deep learning system for identifying glaucomatous optic neuropathy based on color fundus photographs J. Glaucoma 2019 28 1029 1034 10.1097/IJG.0000000000001319 31233461 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Only eight studies14–21 used prospectively collected data”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Ophthalmology imaging
What the sources say
- Supportedcites [14] Abràmoff MD Lavin PT Birch M Shah N Folk JC Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices npj Digital Med. 2018 1 39 10.1038/s41746-018-0040-6 PMC6550188 31304320 source
The Methods (Study design; page not available) state that 900 participants were prospectively enrolled in this ophthalmology study. That supports citing this trial as an example of a study using prospectively collected data; this source alone does not establish the total of eight studies. (LLM, conf=0.91)
- Not checked yetcites [15] Bellemo V Artificial intelligence using deep learning to screen for referable and vision-threatening diabetic retinopathy in Africa: a clinical validation study Lancet Digital Health 2019 1 e35 e44 10.1016/S2589-7500(19)30004-4 33323239 source
- Supportedcites [16] Christopher M Performance of deep learning architectures and transfer learning for detecting glaucomatous optic neuropathy in fundus photographs Sci. Rep. 2018 8 16685 10.1038/s41598-018-35044-9 30420630 PMC6232132 source
The Methods > Data Collection passage says participants came from two prospective longitudinal studies that periodically collected fundus images, supporting this paper's inclusion among studies using prospectively collected data. The count of eight is the citing paper's count across citations 14–21, not a finding attributed to this individual source. (LLM, conf=0.90)
- Supportedcites [17] Gulshan V Performance of a deep-learning algorithm vs manual grading for detecting diabetic retinopathy in India JAMA Ophthalmol 2019 137 987 993 10.1001/jamaophthalmol.2019.2004 31194246 PMC6567842 source
The Study Population section describes this as a prospective study and gives the enrollment and data-collection periods at two eye care centers. As one of the studies cited in the sentence, it supports the claim that it used prospectively collected data; the count of eight is the citing paper’s own tally. (LLM, conf=0.92)
- Could not verifycites [18] Keel S Wu J Lee PY Scheetz J He M Visualizing deep learning models for the detection of referable diabetic retinopathy and glaucoma JAMA Ophthalmol. 2019 137 288 292 10.1001/jamaophthalmol.2018.6035 30570648 PMC6440231 sourceExperimental — accuracy not yet measured
The Methods describe selecting images from existing validation data sets and call the study’s use of those images retrospective. They do not say whether the images were originally collected prospectively. This paper also cannot establish the citing sentence’s count of eight studies. (LLM, conf=0.76)
- Supportedcites [19] Sandhu HS Automated diagnosis and grading of diabetic retinopathy using optical coherence tomography Investig. Ophthalmol. Vis. Sci. 2018 59 3155 3160 10.1167/iovs.17-23677 30029278 PMC6018370 source
The Results section states that OCT scans were collected prospectively, confirming this paper as an example among the studies cited. This source alone does not establish the citing document’s total of eight studies. (LLM, conf=0.93)
- Not checked yetcites [20] Zheng C Detecting glaucoma based on spectral domain optical coherence tomography imaging of peripapillary retinal nerve fiber layer: a comparison study between hand-crafted features and deep learning model Graefes Arch. Clin. Exp. Ophthalmol. 2020 258 577 585 10.1007/s00417-019-04543-4 31811363 source
- Supportedcites [21] Kanagasingam Y Evaluation of artificial intelligence-based grading of diabetic retinopathy in primary care JAMA Netw. Open 2018 1 e182665 e182665 10.1001/jamanetworkopen.2018.2665 30646178 PMC6324474 source
The Methods section (‘Deployment in a Primary Care Practice’; page unavailable) describes inviting patients during a six-month deployment and acquiring their retinal images as they participated. This supports citing the paper as an example of a study using prospectively collected data; the citation does not ask this individual study to establish the total of eight. (LLM, conf=0.88)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Only eight studies in ophthalmology imaging14,21,32,33,43,55,108,109, ten studies in respiratory imaging64,66,70,72,75,79,82,87,89,110 and six studies in breast imaging62,91,97,104,106,111 mentioned adherence to the STARD-2015 guidelines or had a STARD flow diagram in the manuscript.”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Variation of reporting
What the sources say
- Partly supportedcites [14] Abràmoff MD Lavin PT Birch M Shah N Folk JC Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices npj Digital Med. 2018 1 39 10.1038/s41746-018-0040-6 PMC6550188 31304320 sourceExperimental — accuracy not yet measured
The Results (Study population; page unavailable) identify this as an ophthalmology imaging study and refer to Fig. 1 when accounting for enrolled, completed, and analyzable participants. Our copy does not identify that figure as a STARD flow diagram or mention adherence to STARD-2015. This single study also cannot establish the citing paper’s count of eight studies. (LLM, conf=0.72)
- Supportedcites [21] Kanagasingam Y Evaluation of artificial intelligence-based grading of diabetic retinopathy in primary care JAMA Netw. Open 2018 1 e182665 e182665 10.1001/jamanetworkopen.2018.2665 30646178 PMC6324474 source
The Methods section states that the trial was conducted according to the Standards for Reporting of Diagnostic Accuracy (STARD) reporting guideline. The paper is a diabetic-retinopathy imaging study, so it supports its inclusion as an example among the ophthalmology studies; it is not cited as the source of the total count of eight. (LLM, conf=0.91)
- Could not verifycites [32] Li F Automatic detection of diabetic retinopathy in retinal fundus photographs based on deep learning algorithm Transl. Vis. Sci. Technol. 2019 8 4 10.1167/tvst.8.6.4 31737428 PMC6855298 sourceExperimental — accuracy not yet measured
The Methods section describes a flowchart of the algorithm’s image-processing steps (Figure 1), but does not identify it as a STARD flow diagram. Searches for STARD-2015, diagnostic-accuracy reporting standards, and a patient-flow diagram found no passage in our copy establishing that this study met either condition. This paper alone also cannot establish the count of eight studies. (LLM, conf=0.75)
- Not checked yetcites [33] Li Z An automated grading system for detection of vision-threatening referable diabetic retinopathy on the basis of color fundus photographs Diabetes Care 2018 41 2509 2516 10.2337/dc18-0147 30275284 source
- Supportedcites [43] Verbraak FD Diagnostic accuracy of a device for the automated detection of diabetic retinopathy in a primary care setting Diabetes Care 2019 42 651 10.2337/dc18-0148 30765436 source
The Results section refers to “STARD diagrams [Figs. 1 and 2],” and the Conclusions label both figures as STARD diagrams. This confirms that the cited ophthalmology study had a STARD flow diagram; the count of eight is the citing paper’s tally across studies. (LLM, conf=0.93)
- Partly supportedcites [55] Li F Deep learning-based automated detection of retinal diseases using optical coherence tomography images Biomed. Opt. Express 2019 10 6204 6226 10.1364/BOE.10.006204 31853395 PMC6913386 sourceExperimental — accuracy not yet measured
Section 2.2 (p. 5) identifies this as an ophthalmology imaging study and says Fig. 2 displays its dataset selection and stratification process. Our copy does not identify that figure as a STARD flow diagram or mention adherence to STARD-2015. This individual paper also cannot establish the citing document’s count of eight studies. (LLM, conf=0.75)
- Not checked yetcites [108] Li Z Efficacy of a deep learning system for detecting glaucomatous optic neuropathy based on color fundus photographs Ophthalmology 2018 125 1199 1206 10.1016/j.ophtha.2018.01.023 29506863 source
- Could not verifycites [109] Lin H Diagnostic efficacy and therapeutic decision-making capacity of an artificial intelligence platform for childhood cataracts in eye clinics: a multicentre randomized controlled trial EClinicalMedicine 2019 9 52 59 10.1016/j.eclinm.2019.03.001 31143882 PMC6510889 sourceExperimental — accuracy not yet measured
The Methods (Study Design and Participants; page unavailable) state that the trial followed CONSORT guidelines, while the Results label Fig. 1 a “Trial profile.” Searches for STARD-2015 and a STARD flow diagram found no passage establishing either criterion for this paper. This source also cannot establish the citing document’s count of eight studies. (LLM, conf=0.72)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“eight91–98 studies validated algorithms on external data”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Breast imaging
What the sources say
- Not checked yetcites [91] Becker AS Deep learning in mammography: diagnostic accuracy of a multipurpose image analysis software in the detection of breast cancer Investig. Radio. 2017 52 434 440 10.1097/RLI.0000000000000358 28212138 source
- Not checked yetcites [92] Ciritsis A Automatic classification of ultrasound breast lesions using a deep convolutional neural network mimicking human decision-making Eur. Radio. 2019 29 5458 5468 10.1007/s00330-019-06118-7 30927100 source
- Not checked yetcites [93] Cogan T Cogan M Tamil L RAMS: remote and automatic mammogram screening Comput. Biol. Med. 2019 107 18 29 10.1016/j.compbiomed.2019.01.024 30771549 source
- Supportedcites [94] McKinney SM International evaluation of an AI system for breast cancer screening Nature 2020 577 89 94 10.1038/s41586-019-1799-6 31894144 source
The Generalisation across populations section (p. 4) says the authors trained the AI system only on UK data and evaluated it on a US test set, supporting this paper as one example of external-data validation. The eight-study count refers to the group of cited studies, not to eight studies conducted in this paper. (LLM, conf=0.92)
- Not checked yetcites [95] Peng W Mayorga RV Hussein EMA An automated confirmatory system for analysis of mammograms Comput. Methods Prog. Biomed. 2016 125 134 144 10.1016/j.cmpb.2015.09.019 26742491 source
- Supportedcites [96] Ribli D Horváth A Unger Z Pollner P Csabai I Detecting and classifying lesions in mammograms with deep learning Sci. Rep. 2018 8 4165 10.1038/s41598-018-22437-z 29545529 PMC5854668 source
The Data section states that the model was trained on DDSM and Semmelweis University data and tested on the separate public INbreast dataset. That supports citing this paper as one study that validated an algorithm on external data; the paper does not itself establish the citing sentence’s total of eight studies. (LLM, conf=0.88)
- Not checked yetcites [97] Rodríguez-Ruiz A Detection of Breast cancer with mammography: effect of an artificial intelligence support system Radiology 2018 290 305 314 10.1148/radiol.2018181371 30457482 source
- Supportedcites [98] Rodriguez-Ruiz A Stand-alone artificial intelligence for breast cancer detection in mammography: comparison with 101 radiologists J. Natl Cancer Inst. 2019 111 916 922 10.1093/jnci/djy222 30834436 PMC6748773 source
The Artificial Intelligence System section (p. 3) says the mammograms used in this study had never been used to train, validate, or test the algorithms. This supports citing the paper as one of the studies that evaluated an algorithm on external data; the count of eight refers to the citing document’s group of studies, not to this paper alone. (LLM, conf=0.92)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
131 more claims · 3 with their cited sources checked
Create a free account to see all 211 claims and to verify the 92 references still open.
- Probably not a substantial claim. 38
- It may state two separate claims as one. 46
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Without sufficient and diverse datasets, deep models trained on histopathology images from one hospital may fail to generalize well on data from a different hospital (out-ofdistribution) 2 .”
From Federated Learning and Differential Privacy for Medical Image Analysis (2021) · cites this paper as [2]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Use of STARD-AI can aid the comprehensive reporting of research that assesses AI diagnostic accuracy using either single or combined test data and can be applied across a broad range of diagnostic modalities.”
From The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence (2025) · cites this paper as [32]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This review built upon the findings of a prior systematic review conducted by members of the STARD-AI team, which evaluated the diagnostic accuracy of deep learning in medical imaging and highlighted widespread variability in study design, methodological quality and reporting practices 32 .”
From The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence (2025) · cites this paper as [32]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“Two hundred seventy-three studies were included for meta-analysis, 82 in ophthalmology, 115 in respiratory medicine and 82 in breast cancer (see Fig. 1).”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Search and study selection
Reported 273 · recomputed 279
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Ophthalmology imaging
“specificity was 0.907 (95% CI 0.907–1.066).”
§ Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis > Results > Search and study selection
“| RFP | ROP | | | | 0.96 | 0.913–1.008 | 99.5 | 0.907 | 0.749–1.066 | 99.8 |”
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
the CONSORT Group, Schulz, K. F., Altman, D. G., & Moher, D. (2010) · BMC Medicine · doi:10.1186/1741-7015-8-18 · Cited by 13,371
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450
CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
Schulz, K. F., Altman, D. G., Moher, D., & for the CONSORT Group (2010) · BMJ · doi:10.1136/bmj.c332 · Cited by 9,329
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
SPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials
Chan, A.-W., Tetzlaff, J. M., Altman, D. G., Laupacis, A., Gøtzsche, P. C., Krleža-Jerić, K., Hróbjartsson, A., Mann, H., Dickersin, K., Berlin, J. A., et al. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-3-201302050-00583 · Cited by 7,363
A guide to deep learning in healthcare
Esteva, A., Robicquet, A., Ramsundar, B., Kuleshov, V., DePristo, M., Chou, K., Cui, C., Corrado, G., Thrun, S., & Dean, J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0316-z · Cited by 5,312
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · BMJ · doi:10.1136/bmj.g7594 · Cited by 4,388
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660
Predicting the future - big data, machine learning, and clinical medicine
Obermeyer, Z., & Emanuel, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmp1606181 · Cited by 3,652 · cited 2×
“Therefore, the aim of this review is to (1) quantify the diagnostic accuracy of DL in speciality-specific radiological imaging modalities to identify or classify disease, and (2) to appraise the variation in methodology and reporting of DL-based radiological diagnosis, in order to highlight the most common flaws that…”
BackgroundReitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.639 · Cited by 3,293
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Self-citationMcInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Key challenges for delivering clinical impact with artificial intelligence
Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1426-2 · Cited by 3,136
Self-citationClinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Self-citationBig Data and Machine Learning in Health Care
Beam, A. L., & Kohane, I. S. (2018) · JAMA · doi:10.1001/jama.2017.18391 · Cited by 2,506
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Self-citationArdila, D., Kiraly, A. P., Bharadwaj, S., Choi, B., Reicher, J. J., Peng, L., Tse, D., Etemadi, M., Ye, W., Corrado, G., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0447-x · Cited by 2,167
(2010) · doi:10.5555/1756006.1859921 · Cited by 1,924
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Lakhani, P., & Sundaram, B. (2017) · Radiology · doi:10.1148/radiol.2017162326 · Cited by 1,775
Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002683 · Cited by 1,719
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Rajpurkar, P., Irvin, J., Ball, R. L., Zhu, K., Yang, B., Mehta, H., Duan, T., Ding, D., Bagul, A., Langlotz, C. P., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002686 · Cited by 1,449
Big data and machine learning algorithms for health-care delivery
Ngiam, K. Y., & Khor, I. W. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30149-4 · Cited by 1,424
Liu, X., Cruz Rivera, S., Moher, D., Calvert, M. J., Denniston, A. K., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Chan, A.-W., Darzi, A., Holmes, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1034-x · Cited by 1,421
Self-citationAutomated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Radiology · doi:10.1148/radiol.2015151516 · Cited by 1,337
Setio, A. A. A., Ciompi, F., Litjens, G., Gerke, P., Jacobs, C., van Riel, S. J., Wille, M. M. W., Naqibullah, M., Sanchez, C. I., & van Ginneken, B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2536809 · Cited by 1,258
Benjamens, S., Dhunnoo, P., & Meskó, B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00324-0 · Cited by 1,215
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Darzi, A., Holmes, C., Yau, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1037-7 · Cited by 933
Self-citationLi, Z., He, Y., Keel, S., Meng, W., Chang, R. T., & He, M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.023 · Cited by 830
Wahl, B., Cossy-Gantner, A., Germann, S., & Schwalbe, N. R. (2018) · BMJ Global Health · doi:10.1136/bmjgh-2018-000798 · Cited by 796
A Deep Learning Mammography-based Model for Improved Breast Cancer Risk Prediction
Yala, A., Lehman, C., Schuster, T., Portnoi, T., & Barzilay, R. (2019) · Radiology · doi:10.1148/radiol.2019182716 · Cited by 758
Artificial Intelligence and the ‘Good Society’: the US, EU, and UK approach
Cath, C., Wachter, S., Mittelstadt, B., Taddeo, M., & Floridi, L. (2017) · Science and Engineering Ethics · doi:10.1007/s11948-017-9901-7 · Cited by 733
Reporting of artificial intelligence prediction models
Collins, G. S., & Moons, K. G. M. (2019) · The Lancet · doi:10.1016/s0140-6736(19)30037-6 · Cited by 701
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Deep Neural Networks Improve Radiologists’ Performance in Breast Cancer Screening
Wu, N., Phang, J., Park, J., Shen, Y., Huang, Z., Zorin, M., Jastrzebski, S., Fevry, T., Katsnelson, J., Kim, E., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2945514 · Cited by 689
Burlina, P. M., Joshi, N., Pekala, M., Pacheco, K. D., Freund, D. E., & Bressler, N. M. (2017) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2017.3782 · Cited by 671
Brown, J. M., Campbell, J. P., Beers, A., Chang, K., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1934 · Cited by 657
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Krause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
What is the State of Neural Network Pruning?
Blalock, D., Ortiz, J. J. G., Frankle, J., & Guttag, J. (2020) · arXiv · doi:10.48550/arxiv.2003.03033 · Cited by 560
Grassmann, F., Mengelkamp, J., Brandl, C., Harsch, S., Zimmermann, M. E., Linkohr, B., Peters, A., Heid, I. M., Palm, C., & Weber, B. H. F. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.02.037 · Cited by 549
Nam, J. G., Park, S., Hwang, E. J., Lee, J. H., Jin, K.-N., Lim, K. Y., Vu, T. H., Sohn, J. H., Hwang, S., Goo, J. M., et al. (2019) · Radiology · doi:10.1148/radiol.2018180237 · Cited by 539
Artificial intelligence and machine learning in clinical development: a translational perspective
Shah, P., Kendall, F., Khozin, S., Goosen, R., Hu, J., Laramie, J., Ringel, M., & Schork, N. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0148-3 · Cited by 498
Vollmer, S., Mateen, B. A., Bohner, G., Király, F. J., Ghani, R., Jonsson, P., Cumbers, S., Jonas, A., McAllister, K. S. L., Myles, P., et al. (2020) · BMJ · doi:10.1136/bmj.l6927 · Cited by 497
Automated deep-neural-network surveillance of cranial images for acute neurologic events
Titano, J. J., Badgeley, M., Schefflein, J., Pain, M., Su, A., Cai, M., Swinburne, N., Zech, J., Kim, J., Bederson, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0147-y · Cited by 458
Hwang, E. J., Park, S., Jin, K.-N., Kim, J. I., Choi, S. Y., Lee, J. H., Goo, J. M., Aum, J., Yim, J.-J., Cohen, J. G., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.1095 · Cited by 447
van Grinsven, M. J. J. P., van Ginneken, B., Hoyng, C. B., Theelen, T., & Sanchez, C. I. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2526689 · Cited by 426
Bellemo, V., Lim, Z. W., Lim, G., Nguyen, Q. D., Xie, Y., Yip, M. Y. T., Hamzah, H., Ho, J., Lee, X. Q., Hsu, W., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30004-4 · Cited by 419
Self-citationSayres, R., Taly, A., Rahimy, E., Blumer, K., Coz, D., Hammel, N., Krause, J., Narayanaswamy, A., Rastegar, Z., Wu, D., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.11.016 · Cited by 418
Walsh, S. L. F., Calandriello, L., Silva, M., & Sverzellati, N. (2018) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30286-8 · Cited by 390
Challenges to the Reproducibility of Machine Learning Models in Health Care
Beam, A. L., Manrai, A. K., & Ghassemi, M. (2020) · JAMA · doi:10.1001/jama.2019.20866 · Cited by 366
Long, E., Lin, H., Liu, Z., Wu, X., Wang, L., Jiang, J., An, Y., Lin, Z., Li, X., Chen, J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0024 · Cited by 358
Becker, A. S., Marcon, M., Ghafoor, S., Wurnig, M. C., Frauenfelder, T., & Boss, A. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000358 · Cited by 352
Peng, Y., Dharssi, S., Chen, Q., Keenan, T. D., Agrón, E., Wong, W. T., Chew, E. Y., & Lu, Z. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.11.015 · Cited by 349
Bluemke, D. A., Moy, L., Bredella, M. A., Ertl-Wagner, B. B., Fowler, K. J., Goh, V. J., Halpern, E. F., Hess, C. P., Schiebler, M. L., & Weiss, C. R. (2020) · Radiology · doi:10.1148/radiol.2019192515 · Cited by 343
Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
How to read a funnel plot in a meta-analysis
Sedgwick, P., & Marston, L. (2015) · BMJ · doi:10.1136/bmj.h4718 · Cited by 318
Liu, H., Li, L., Wormstone, I. M., Qiao, C., Zhang, C., Liu, P., Li, S., Wang, H., Mou, D., Pang, R., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.3501 · Cited by 307
Self-citationTowards automatic pulmonary nodule management in lung cancer screening with deep learning
Ciompi, F., Chung, K., van Riel, S. J., Setio, A. A. A., Gerke, P. K., Jacobs, C., Scholten, E. T., Schaefer-Prokop, C., Wille, M. M. W., Marchianò, A., et al. (2017) · Scientific Reports · doi:10.1038/srep46479 · Cited by 304
Automated Triaging of Adult Chest Radiographs with Deep Artificial Neural Networks
Annarumma, M., Withey, S. J., Bakewell, R. J., Pesce, E., Goh, V., & Montana, G. (2019) · Radiology · doi:10.1148/radiol.2018180921 · Cited by 303
Gulshan, V., Rajan, R. P., Widner, K., Wu, D., Wubbels, P., Rhodes, T., Whitehouse, K., Coram, M., Corrado, G., Ramasamy, K., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.2004 · Cited by 303
Qin, Z. Z., Sander, M. S., Rai, B., Titahong, C. N., Sudrungrot, S., Laah, S. N., Adhikari, L. M., Carter, E. J., Puri, L., Codlin, A. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-51503-3 · Cited by 289
(2017) · Radboud Repository (Radboud University) · Cited by 284
Majkowska, A., Mittal, S., Steiner, D. F., Reicher, J. J., McKinney, S. M., Duggan, G. E., Eswaran, K., Cameron Chen, P.-H., Liu, Y., Kalidindi, S. R., et al. (2020) · Radiology · doi:10.1148/radiol.2019191293 · Cited by 277
Truhn, D., Schrading, S., Haarburger, C., Schneider, H., Merhof, D., & Kuhl, C. (2019) · Radiology · doi:10.1148/radiol.2018181352 · Cited by 273
Sounderajah, V., Ashrafian, H., Aggarwal, R., De Fauw, J., Denniston, A. K., Greaves, F., Karthikesalingam, A., King, D., Liu, X., Markar, S. R., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0941-1 · Cited by 270
Self-citationGómez-Valverde, J. J., Antón, A., Fatti, G., Liefers, B., Herranz, A., Santos, A., Sánchez, C. I., & Ledesma-Carbayo, M. J. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.000892 · Cited by 265
Li, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255
Self-citationHuman–machine partnership with artificial intelligence for chest radiograph diagnosis
Patel, B. N., Rosenberg, L., Willcox, G., Baltaxe, D., Lyons, M., Irvin, J., Rajpurkar, P., Amrhein, T., Gupta, R., Halabi, S., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0189-7 · Cited by 254
Byra, M., Galperin, M., Ojeda‐Fournier, H., Olson, L., O'Boyle, M., Comstock, C., & Andre, M. (2019) · Medical Physics · doi:10.1002/mp.13361 · Cited by 253
Development of a deep residual learning algorithm to screen for glaucoma from fundus photography
Shibata, N., Tanito, M., Mitsuhashi, K., Fujino, Y., Matsuura, M., Murata, H., & Asaoka, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-33013-w · Cited by 249
Sim, Y., Chung, M. J., Kotter, E., Yune, S., Kim, M., Do, S., Han, K., Kim, H., Yang, S., Lee, D.-J., et al. (2020) · Radiology · doi:10.1148/radiol.2019182465 · Cited by 248
Hwang, E. J., Park, S., Jin, K.-N., Kim, J. I., Choi, S. Y., Lee, J. H., Goo, J. M., Aum, J., Yim, J.-J., Park, C. M., et al. (2019) · Clinical Infectious Diseases · doi:10.1093/cid/ciy967 · Cited by 241
Ruamviboonsuk, P., Krause, J., Chotcomwongse, P., Sayres, R., Raman, R., Widner, K., Campana, B. J. L., Phene, S., Hemarat, K., Tadarati, M., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0099-8 · Cited by 233
Burlina, P., Pacheco, K. D., Joshi, N., Freund, D. E., & Bressler, N. M. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.01.018 · Cited by 219
Taylor, A. G., Mielke, C., & Mongan, J. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002697 · Cited by 212
A Deep Learning Model to Triage Screening Mammograms: A Simulation Study
Yala, A., Schuster, T., Miles, R., Barzilay, R., & Lehman, C. (2019) · Radiology · doi:10.1148/radiol.2019182908 · Cited by 210
Assessment of Convolutional Neural Networks for Automated Classification of Chest Radiographs
Dunnmon, J. A., Yi, D., Langlotz, C. P., Ré, C., Rubin, D. L., & Lungren, M. P. (2019) · Radiology · doi:10.1148/radiol.2018181422 · Cited by 206
Lin, H., Li, R., Liu, Z., Chen, J., Yang, Y., Chen, H., Lin, Z., Lai, W., Long, E., Wu, X., et al. (2019) · EClinicalMedicine · doi:10.1016/j.eclinm.2019.03.001 · Cited by 199
Deep learning in chest radiography: Detection of findings and presence of change
Singh, R., Kalra, M. K., Nitiwarangkul, C., Patti, J. A., Homayounieh, F., Padole, A., Rao, P., Putha, P., Muse, V. V., Sharma, A., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0204155 · Cited by 195
Li, F., Chen, H., Liu, Z., Zhang, X.-D., Jiang, M.-S., Wu, Z.-Z., & Zhou, K.-Q. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.006204 · Cited by 193
Artificial intelligence-based decision-making for age-related macular degeneration
Hwang, D.-K., Hsu, C.-C., Chang, K.-J., Chao, D., Sun, C.-H., Jheng, Y.-C., Yarmishyn, A. A., Wu, J.-C., Tsai, C.-Y., Wang, M.-L., et al. (2019) · Theranostics · doi:10.7150/thno.28447 · Cited by 189
Deep Learning and Glaucoma Specialists
Phene, S., Dunn, R. C., Hammel, N., Liu, Y., Krause, J., Kitade, N., Schaekermann, M., Sayres, R., Wu, D. J., Bora, A., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.024 · Cited by 186
Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care
Kanagasingam, Y., Xiao, D., Vignarajan, J., Preetham, A., Tay-Kearney, M.-L., & Mehrotra, A. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.2665 · Cited by 185
Meta-analyses: how to read a funnel plot
Sedgwick, P. (2013) · BMJ · doi:10.1136/bmj.f1342 · Cited by 183
Fujioka, T., Kubota, K., Mori, M., Kikuchi, Y., Katsuta, L., Kasahara, M., Oda, G., Ishiba, T., Nakagawa, T., & Tateishi, U. (2019) · Japanese Journal of Radiology · doi:10.1007/s11604-019-00831-5 · Cited by 177
Rankin, D., Black, M., Bond, R., Wallace, J., Mulvenna, M., & Epelde, G. (2020) · JMIR Medical Informatics · doi:10.2196/18910 · Cited by 169
Zhang, C., Sun, X., Dang, K., Li, K., Guo, X.-W., Chang, J., Yu, Z.-Q., Huang, F.-Y., Wu, Y.-S., Liang, Z., et al. (2019) · The Oncologist · doi:10.1634/theoncologist.2018-0908 · Cited by 168
Alqudah, A. M. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02066-y · Cited by 168
Deep Learning for Chest Radiograph Diagnosis in the Emergency Department
Hwang, E. J., Nam, J. G., Lim, W. H., Park, S. J., Jeong, Y. S., Kang, J. H., Hong, E. K., Kim, T. M., Goo, J. M., Park, S., et al. (2019) · Radiology · doi:10.1148/radiol.2019191225 · Cited by 164
Becker, A. S., Mueller, M., Stoffel, E., Marcon, M., Ghafoor, S., & Boss, A. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20170576 · Cited by 157
Zhou, J., Luo, L., Dou, Q., Chen, H., Chen, C., Li, G., Jiang, Z., & Heng, P. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26721 · Cited by 154
Big data and medical research in China
Zhang, L., Wang, H., Li, Q., Zhao, M.-H., & Zhan, Q.-M. (2018) · BMJ · doi:10.1136/bmj.j5910 · Cited by 148
Li, F., Liu, Z., Chen, H., Jiang, M., Zhang, X., & Wu, Z. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.6.4 · Cited by 144
Jammal, A. A., Thompson, A. C., Mariottoni, E. B., Berchuck, S. I., Urata, C. N., Estrela, T., Wakil, S. M., Costa, V. P., & Medeiros, F. A. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.11.006 · Cited by 125
Dalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Detection and characterization of MRI breast lesions using deep learning
Herent, P., Schmauch, B., Jehanno, P., Dehaene, O., Saillard, C., Balleyguier, C., Arfi-Rouche, J., & Jégou, S. (2019) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2019.02.008 · Cited by 117
Ciritsis, A., Rossi, C., Eberhard, M., Marcon, M., Becker, A. S., & Boss, A. (2019) · European Radiology · doi:10.1007/s00330-019-06118-7 · Cited by 117
Verbraak, F. D., Abramoff, M. D., Bausch, G. C. F., Klaver, C., Nijpels, G., Schlingemann, R. O., & van der Heijden, A. A. (2019) · Diabetes Care · doi:10.2337/dc18-0148 · Cited by 115
Visualizing Deep Learning Models for the Detection of Referable Diabetic Retinopathy and Glaucoma
Keel, S., Wu, J., Lee, P. Y., Scheetz, J., & He, M. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.6035 · Cited by 114
A Deep Learning-Based Algorithm Identifies Glaucomatous Discs Using Monoscopic Fundus Photographs
Liu, S., Graham, S. L., Schulz, A., Kalloniatis, M., Zangerl, B., Cai, W., Gao, Y., Chua, B., Arvind, H., Grigg, J., et al. (2018) · Ophthalmology Glaucoma · doi:10.1016/j.ogla.2018.04.002 · Cited by 107
Choi, J. S., Han, B.-K., Ko, E. S., Bae, J. M., Ko, E. Y., Song, S. H., Kwon, M.-R., Shin, J. H., & Hahn, S. Y. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0530 · Cited by 104
Matsuba, S., Tabuchi, H., Ohsugi, H., Enno, H., Ishitobi, N., Masumoto, H., & Kiuchi, Y. (2018) · International Ophthalmology · doi:10.1007/s10792-018-0940-0 · Cited by 99
Nakajima, Y., Yamada, K., Imamura, K., & Kobayashi, K. (2008) · Radiation Medicine · doi:10.1007/s11604-008-0259-2 · Cited by 97
Li, L., Liu, Z., Huang, H., Lin, M., & Luo, D. (2019) · Thoracic Cancer · doi:10.1111/1759-7714.12931 · Cited by 86
Keel, S., Li, Z., Scheetz, J., Robman, L., Phung, J., Makeyeva, G., Aung, K., Liu, C., Yan, X., Meng, W., et al. (2019) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.13575 · Cited by 85
Park, S., Lee, S. M., Lee, K. H., Jung, K.-H., Bae, W., Choe, J., & Seo, J. B. (2019) · European Radiology · doi:10.1007/s00330-019-06532-x · Cited by 85
Uthoff, J., Stephens, M. J., Newell, J. D., Hoffman, E. A., Larson, J., Koehn, N., De Stefano, F. A., Lusk, C. M., Wenzlaff, A. S., Watza, D., et al. (2019) · Medical Physics · doi:10.1002/mp.13592 · Cited by 84
Diabetic retinopathy screening using deep neural network
Ramachandran, N., Hong, S. C., Sime, M. J., & Wilson, G. (2017) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.13056 · Cited by 83
Ting, D. S. W., Cheung, C. Y., Nguyen, Q., Sabanayagam, C., Lim, G., Lim, Z. W., Tan, G. S. W., Soh, Y. Q., Schmetterer, L., Wang, Y. X., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0097-x · Cited by 82
Self-citationAsaoka, R., Tanito, M., Shibata, N., Mitsuhashi, K., Nakahara, K., Fujino, Y., Matsuura, M., Murata, H., Tokumo, K., & Kiuchi, Y. (2019) · Ophthalmology Glaucoma · doi:10.1016/j.ogla.2019.03.008 · Cited by 77
Zhang, Y., Wang, L., Wu, Z., Zeng, J., Chen, Y., Tian, R., Zhao, J., & Zhang, G. (2019) · IEEE Access · doi:10.1109/access.2018.2881042 · Cited by 74
MacCormick, I. J. C., Williams, B. M., Zheng, Y., Li, K., Al-Bander, B., Czanner, S., Cheeseman, R., Willoughby, C. E., Brown, E. N., Spaeth, G. L., et al. (2019) · PLOS ONE · doi:10.1371/journal.pone.0209409 · Cited by 74
Park, S., Lee, S. M., Kim, N., Choe, J., Cho, Y., Do, K.-H., & Seo, J. B. (2019) · European Radiology · doi:10.1007/s00330-019-06130-x · Cited by 71
Liang, C.-H., Liu, Y.-C., Wu, M.-T., Garcia-Castro, F., Alberich-Bayarri, A., & Wu, F.-Z. (2020) · Clinical Radiology · doi:10.1016/j.crad.2019.08.005 · Cited by 69
Al-Aswad, L. A., Kapoor, R., Chu, C. K., Walters, S., Gong, D., Garg, A., Gopal, K., Patel, V., Sameer, T., Rogers, T. W., et al. (2019) · Journal of Glaucoma · doi:10.1097/ijg.0000000000001319 · Cited by 59
Wang, S., Wang, R., Zhang, S., Li, R., Fu, Y., Sun, X., Li, Y., Sun, X., Jiang, X., Guo, X., et al. (2018) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2018.06.03 · Cited by 57
Nagasato, D., Tabuchi, H., Masumoto, H., Enno, H., Ishitobi, N., Kameoka, M., Niki, M., & Mitamura, Y. (2019) · PLoS ONE · doi:10.1371/journal.pone.0223965 · Cited by 57
Performance of Deep Learning Model in Detecting Operable Lung Cancer With Chest Radiographs
Cha, M. J., Chung, M. J., Lee, J. H., & Lee, K. S. (2019) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000388 · Cited by 56
Utility of Deep Learning Methods for Referability Classification of Age-Related Macular Degeneration
Burlina, P., Joshi, N., Pacheco, K. D., Freund, D. E., Kong, J., & Bressler, N. M. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.3799 · Cited by 54
Deep learning-enabled system for rapid pneumothorax screening on chest CT
Li, X., Thrall, J. H., Digumarthy, S. R., Kalra, M. K., Pandharipande, P. V., Zhang, B., Nitiwarangkul, C., Singh, R., Khera, R. D., & Li, Q. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.108692 · Cited by 51
Rogers, T. W., Jaccard, N., Carbonaro, F., Lemij, H. G., Vermeer, K. A., Reus, N. J., & Trikha, S. (2019) · Eye · doi:10.1038/s41433-019-0510-3 · Cited by 47
Bridging the Health Data Divide
Celi, L. A., Davidzon, G., Johnson, A. E., Komorowski, M., Marshall, D. C., Nair, S. S., Phillips, C. T., Pollard, T. J., Raffa, J. D., Salciccioli, J. D., et al. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.6400 · Cited by 46
Automated Diagnosis and Grading of Diabetic Retinopathy Using Optical Coherence Tomography
Sandhu, H. S., Eltanboly, A., Shalaby, A., Keynton, R. S., Schaal, S., & El-Baz, A. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-23677 · Cited by 44
An automated confirmatory system for analysis of mammograms
Peng, W., Mayorga, R. V., & Hussein, E. M. A. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.09.019 · Cited by 43
Chae, K. J., Jin, G. Y., Ko, S. B., Wang, Y., Zhang, H., Choi, E. J., & Choi, H. (2020) · Academic Radiology · doi:10.1016/j.acra.2019.05.018 · Cited by 40
Zheng, C., Xie, X., Huang, L., Chen, B., Yang, J., Lu, J., Qiao, T., Fan, Z., & Zhang, M. (2020) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-019-04543-4 · Cited by 40
Chan, G. C. Y., Kamble, R. M., Müller, H., Shah, S. A. A., Tang, T. B., & Mériaudeau, F. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512371 · Cited by 39
The Ethics of Biomedical ‘Big Data’ Analytics
Mittelstadt, B. (2019) · Philosophy & Technology · doi:10.1007/s13347-019-00344-z · Cited by 38
Bhatia, K. K., Graham, M. S., Terry, L., Wood, A., Tranos, P., Trikha, S., & Jaccard, N. (2019) · Retina · doi:10.1097/iae.0000000000002640 · Cited by 34
Guidelines for Diagnostic Tests and Diagnostic Accuracy in Surgical Research
Jones, C. M., Ashrafian, H., Darzi, A. W., & Athanasiou, T. (2010) · Journal of Investigative Surgery · doi:10.3109/08941930903469508 · Cited by 30
Self-citationRAMS: Remote and automatic mammogram screening
Cogan, T., Cogan, M., & Tamil, L. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.01.024 · Cited by 18
Kim, S. M., Han, H. S., Park, J. M., Choi, Y. J., Yoon, H. S., Sohn, J. H., Baek, M. H., Kim, Y. N., Chae, Y. M., June, J. J., et al. (2012) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-012-9457-7 · Cited by 16
Raumviboonsuk, P., Krause, J., Chotcomwongse, P., Sayres, R., Raman, R., Widner, K., Campana, B. J. L., Phene, S., Hemarat, K., Tadarati, M., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1810.08290 · Cited by 10
Cited by
Large language models in medicine
Thirunavukarasu, A. J., Ting, D. S. J., Elangovan, K., Gutierrez, L., Tan, T. F., & Ting, D. S. W. (2023) · Nature Medicine · doi:10.1038/s41591-023-02448-8 · Cited by 3,944
Self-citationAntimicrobial resistance: a concise update
Ho, C. S., Wong, C. T. H., Aung, T. T., Lakshminarayanan, R., Mehta, J. S., Rauz, S., McNally, A., Kintses, B., Peacock, S. J., de la Fuente-Nunez, C., et al. (2025) · The Lancet Microbe · doi:10.1016/j.lanmic.2024.07.010 · Cited by 634
Self-citationThe STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence
Sounderajah, V., Guni, A., Liu, X., Collins, G. S., Karthikesalingam, A., Markar, S. R., Golub, R. M., Denniston, A. K., Shetty, S., Moher, D., et al. (2025) · Nature Medicine · doi:10.1038/s41591-025-03953-8 · Cited by 592
Self-citationOpening the black box: the promise and limitations of explainable machine learning in cardiology
Petch, J., Di, S., & Nelson, W. (2022) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2021.09.004 · Cited by 552
Federated Learning and Differential Privacy for Medical Image Analysis
Adnan, M., Kalra, S., Cresswell, J. C., Taylor, G. W., & Tizhoosh, H. (2021) · doi:10.21203/rs.3.rs-1005694/v1 · Cited by 464
Metadata
- Authors
- Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A.
- Affiliations
- Imperial College London (GB)
- Singapore National Eye Center (SG)
- Corresponding author
- Ashrafian, Hutan
- ORCID
- Venue
- npj Digital Medicine
- Published
- 2021-04-07
- Volume
- 4
- Issue
- 1
- Pages
- 65-65
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC8027892
- OpenAlex
- W3150212014
- Semantic Scholar
- e35f243b2d2c60d4c3b03379d44901dc597e175d
- Cited by
- 946
- References
- 143
- Citations by year
- 2026: 188 · 2025: 259 · 2024: 196 · 2023: 166 · 2022: 104 · 2021: 31
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Spiral (Imperial College London) (submittedVersion, cc-by)
- Funders
- National Institute for Health and Care Research (NF-SI-0510-10186, NF-SI-0617-10038, CL-2019-21-503, NIHR-INF-0738)
- NIHR Imperial Biomedical Research Centre
- Topics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Keywords
- deep learning, diagnostic accuracy, diagnostic imaging, artificial intelligence in healthcare, diabetic retinopathy, age-related macular degeneration, glaucoma, retinal fundus photographs, optical coherence tomography, pulmonary nodules, lung cancer, breast cancer, mammography, digital breast tomosynthesis, STARD, reporting guidelines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-05, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-05 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.