Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; none of the 24 sources its claims cite is checked for support yet.
Abstract
Ultra-thin-body dual-gate ISFET with enhanced sensitivity and stability via capacitive coupling.
Overview
CoChat Summary
TL;DR
This paper shows that making a dual-gate ISFET ultra-thin can substantially improve capacitive coupling, boosting pH sensitivity and reducing leakage-related instability. A 4.3 nm body device achieved 425.89 mV/pH sensitivity and better linearity, hysteresis, and drift than thicker-body devices.
Key findings
- The ultra-thin-body (UTB) DG ISFET with a 4.3 nm body achieved a sensitivity of 425.89 mV/pH, which the paper says is more than twice that of an 85 nm body device.
- For DG operation, sensitivity increased as body thickness decreased; by contrast, in SG operation the sensitivity stayed in a similar range of 39.82 to 47.19 mV/pH.
- Linearity improved with thinner bodies: 99.72% (±0.08%) at 4.3 nm, 98.24% (±0.32%) at 30 nm, and 97.69% (±0.96%) at 61 nm.
- The UTB device reduced leakage currents and made the experimental amplification factor nearly match the ideal one, with an error of 1.41%; thicker-body devices showed larger deviations and worse hysteresis/drift.
Methods
- The study fabricated DG ISFETs on fully depleted p-type (100) SOI substrates with a 107 nm top silicon layer and 224 nm BOX, then thinned the silicon using 2.38% TMAH etching to produce bodies including 4.3 nm, 30 nm, 61 nm, and 85 nm.
- Device geometry included a 10 μm × 10 μm active channel; sensing used a 23 nm SiO2 membrane, pH buffer solutions, and Ag/AgCl reference electrodes measured with a Hewlett-Packard 4156B analyzer.
- Analysis compared DG vs SG transfer behavior, extracted sensitivity, linearity, amplification factor, hysteresis width, and drift rate, and used ATLAS (Silvaco) simulations for coupling-ratio/body-thickness effects.
Limitations
- The paper explicitly notes that thick body devices suffer from inversion-lopsided coupling, leakage fluctuations, and unstable coupling ratios, which degrade performance; this is presented as a device limitation rather than a study design limitation.
- The Methods section states the body thickness of the thick-device comparison is important because the channel condition can affect whether the other interface is fully depleted; the text makes evident that results depend on specific fabricated SOI/SiO2 devices, so generalization to other materials or architectures is not directly established (inferred from the paper’s device-specific setup).
- Not stated in the paper.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
0 Valid · 0 Not valid · 15 Not checked · 63 Own results and interpretations
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The UTB of 4.3 nm serves to not only increase its sensitivity, but also to strongly suppress the leakage components, leading to a better stability of the DG ISFET.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The UTB of 4.3 nm serves to not only increase its sensitivity, but also to strongly suppress the leakage components, leading to a better stability of the DG ISFET.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Abstract
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The sensitivity of a 4.3-nm-thick UTB device is increased by more than twice, compared to an 85 nm body device, and greater stability improvements can be made in this geometrical property.”
- Also stated in: § Sensing performance of the DG ISFET · plain
“In aspect of the fact that the sensitivity is increased by more than twice, compared to an 85 nm body device, the body thickness effect cannot be ignored in the DG ISFET platform.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Sensing performance of the DG ISFET · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“while the secondary interface becomes either inversion or accumulation by the applied biases, an 85-nm body device reveals saturated or uneven shifts from the induced carriers.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Results > Electrical characteristics of the DG MOSFET
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“The other peculiar point in the plot is the shape of the leakage currents; they are randomly fluctuated with thin secondary inverted carriers20; this indicates that parallel shifts do not occur, with the secondary potential changes at regular intervals.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Results > Electrical characteristics of the DG MOSFET
What the sources say
- Not checked — no full text of the sourcecites [20] Colinge J.-P. Transcoductance of silicon-on-insulator (SOI) MOSFET's. IEEE Electron Device Lett. EDL-6, 573– 574 (1985). source
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
47 more claims
Create a free account to see all 78 claims and to verify the 7 references still open.
- It may state two separate claims as one. 22
- The quote only partly states this claim. 3
- Probably not a substantial claim. 6
Citations
Cites
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Threshold voltage of thin-film Silicon-on-insulator (SOI) MOSFET's
Lim, H.-K., & Fossum, J. G. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21282 · Cited by 695
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Matsuo, T., & Esashi, M. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80006-6 · Cited by 343
Ultimately thin double-gate SOI MOSFETs
Ernst, T., Cristoloveanu, S., Ghibaudo, G., Ouisse, T., Horiguchi, S., Ono, Y., Takahashi, Y., & Murase, K. (2003) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2003.811371 · Cited by 245
A physical model for drift in pH ISFETs
Jamasb, S., Collins, S., & Smith, R. L. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00040-9 · Cited by 239
The role of buried OH sites in the response mechanism of inorganic-gate pH-sensitive ISFETs
Bousse, L., & Bergveld, P. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80028-1 · Cited by 198
Research works printed but not linked: 1
- Bergveld P. ISFET, theory and practice. Proceedings of the IEEE Sensor Conference Toronto, Ontario, Oct., 1– 26 (2003).
Cited by
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Singh, S., Anil, A. G., Kumar, V., Kapoor, D., Subramanian, S., Singh, J., & Ramamurthy, P. C. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2021.131996 · Cited by 295
Flexible Field-Effect Transistor-Type Sensors Based on Conjugated Molecules
Lee, Y. H., Jang, M., Lee, M. Y., Kweon, O. Y., & Oh, J. H. (2017) · Chem · doi:10.1016/j.chempr.2017.10.005 · Cited by 200
Qin, Y., Kwon, H.-J., Howlader, M. M. R., & Deen, M. J. (2015) · RSC Advances · doi:10.1039/c5ra11291e · Cited by 196
Lowe, B. M., Sun, K., Zeimpekis, I., Skylaris, C., & Green, N. G. (2017) · The Analyst · doi:10.1039/c7an00455a · Cited by 169
Quasi-Two-Dimensional Metal Oxide Semiconductors Based Ultrasensitive Potentiometric Biosensors
Chen, H., Rim, Y. S., Wang, I. C., Li, C., Zhu, B., Sun, M., Goorsky, M. S., He, X., & Yang, Y. (2017) · ACS Nano · doi:10.1021/acsnano.7b00628 · Cited by 101
Interface Engineering of Metal Oxide Semiconductors for Biosensing Applications
Rim, Y. S., Chen, H., Zhu, B., Bae, S., Zhu, S., Li, P. J., Wang, I. C., & Yang, Y. (2017) · Advanced Materials Interfaces · doi:10.1002/admi.201700020 · Cited by 101
A comprehensive review of FET‐based pH sensors: materials, fabrication technologies, and modeling
Sinha, S., & Pal, T. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100147 · Cited by 118
Recent Advances of Field-Effect Transistor Technology for Infectious Diseases
Panahi, A., Sadighbayan, D., Forouhi, S., & Ghafar‐Zadeh, E. (2021) · Biosensors · doi:10.3390/bios11040103 · Cited by 84
Kumar, N. C., Kumar, J., & Panda, S. (2016) · IEEE Electron Device Letters · doi:10.1109/led.2016.2536359 · Cited by 80
Lee, I., Lee, K. H., Lee, S., & Cho, W.-J. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am506805a · Cited by 69
Self-citationSpecific and label-free immunosensing of protein-protein interactions with silicon-based immunoFETs
Bhattacharyya, I. M., Cohen, S., Shalabny, A., Bashouti, M. Y., Akabayov, B., & Shalev, G. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.03.003 · Cited by 60
Flexible organic thin-film transistor immunosensor printed on a one-micron-thick film
Minamiki, T., Minami, T., Chen, Y.-P., Mano, T., Takeda, Y., Fukuda, K., & Tokito, S. (2021) · Communications Materials · doi:10.1038/s43246-020-00112-z · Cited by 66
Jang, H., Ahn, J., Kim, M., Shin, Y., Jeun, M., Cho, W.-J., & Lee, K. H. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.020 · Cited by 62
Self-citationLee, I.-K., Jeun, M., Jang, H., Cho, W.-J., & Lee, K. H. (2015) · Nanoscale · doi:10.1039/c5nr03146j · Cited by 58
Self-citationCurrent advances and future visions on bioelectronic immunosensing for prostate-specific antigen
Ibau, C., Arshad, M. K. M., & Gopinath, S. C. B. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.049 · Cited by 55
Precision pH Sensor Based on WO 3 Nanofiber-Polymer Composites and Differential Amplification
Choi, S., Savagatrup, S., Kim, Y., Lang, J. H., & Swager, T. M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01579 · Cited by 55
Modeling of gate underlap junctionless double gate MOSFET as bio-sensor
Ajay, Narang, R., Saxena, M. K., & Gupta, M. (2017) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2017.08.008 · Cited by 49
Pulse electrochemical synaptic transistor for supersensitive and ultrafast biosensors
Ji, J., Wang, Z., Zhang, F., Wang, B., Niu, Y., Jiang, X., Qiao, Z., Ren, T., Zhang, W., Sang, S., et al. (2023) · InfoMat · doi:10.1002/inf2.12478 · Cited by 51
High-Performance Double-Gate $\alpha $ -InGaZnO ISFET pH Sensor Using a HfO2 Gate Dielectric
Lu, C.-H., Hou, T., & Pan, T.-M. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2776144 · Cited by 54
High-performance integrated field-effect transistor-based sensors
Adzhri, R., Arshad, M. K. M., Gopinath, S. C. B., Ruslinda, A. R., Fathil, M. F. M., Ayub, R. M., Nor, M. N. M., & Voon, C. H. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.02.042 · Cited by 54
Cho, S.-K., & Cho, W.-J. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128835 · Cited by 45
Self-citationAn Accurate TCAD-Based Model for ISFET Simulation
Mohammadi, E., & Manavizadeh, N. (2018) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2018.2857218 · Cited by 45
Wu, T., Alharbi, A., You, K.-D., Kisslinger, K., Stach, E. A., & Shahrjerdi, D. (2017) · ACS Nano · doi:10.1021/acsnano.7b02986 · Cited by 44
Liu, N., Liu, Y., Feng, P., Zhu, L. Q., Shi, Y., & Wan, Q. C. (2015) · Applied Physics Letters · doi:10.1063/1.4913445 · Cited by 39
Lin, C. F., Kao, C. H., Lin, C. Y., Liu, Y. W., & Wang, C. H. (2020) · Results in Physics · doi:10.1016/j.rinp.2020.102976 · Cited by 39
Ultra‐thin ISFET‐based sensing systems
Baghini, M. S., Vilouras, A., Douthwaite, M., Georgiou, P., & Dahiya, R. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100202 · Cited by 36
Hong, E.-K., & Cho, W.-J. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128827 · Cited by 32
Self-citationUnderstanding the signal amplification in dual-gate FET-based biosensors
Ahn, J., Choi, B., & Choi, S. (2020) · Journal of Applied Physics · doi:10.1063/5.0010136 · Cited by 28
Cho, S.-K., & Cho, W.-J. (2021) · Chemosensors · doi:10.3390/chemosensors9030042 · Cited by 28
Self-citationSrikanya, D., Bhat, A. M., & Sahu, C. (2023) · Microelectronics Journal · doi:10.1016/j.mejo.2023.105811 · Cited by 31
2D Materials‐Based Field‐Effect Transistor Biosensors for Healthcare
Li, J., Wijaya, L. N. A., Jang, D. W., Hu, Y., You, J., Cai, Y., Gao, Z., Mi, Y., & Luo, Z. (2024) · Small · doi:10.1002/smll.202408961 · Cited by 35
UTBB FDSOI: Evolution and opportunities
(2016) · doi:10.1016/j.sse.2016.07.003 · Cited by 22
Cho, S.-K., & Cho, W.-J. (2021) · Sensors · doi:10.3390/s21124213 · Cited by 20
Self-citationUltrasensitive Coplanar Dual-Gate ISFETs for Point-of-Care Biomedical Applications
Jeon, J.-H., & Cho, W.-J. (2020) · ACS Omega · doi:10.1021/acsomega.0c00427 · Cited by 21
Self-citationKumar, N. C., Sutradhar, M., Kumar, J., & Panda, S. (2016) · Semiconductor Science and Technology · doi:10.1088/1361-6641/aa5584 · Cited by 22
Lim, C.-M., Lee, I., Lee, K. J., Oh, Y. K., Shin, Y., & Cho, W.-J. (2017) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2016.1253409 · Cited by 21
Self-citationPyo, J., & Cho, W.-J. (2017) · Semiconductor Science and Technology · doi:10.1088/1361-6641/aa584b · Cited by 22
Self-citationKenaan, A., Brunel, F., Raimundo, J., & Charrier, A. M. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128147 · Cited by 19
Kumar, N. C., Bhatt, D., Sutradhar, M., & Panda, S. (2020) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2020.105239 · Cited by 22
Lee, S. M., Park, J., Ahn, S., Jang, S. C., Kim, H., & Kim, H. (2024) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.4c01027 · Cited by 21
Dutta, J. C., Thakur, H. R., & Keshwani, G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2904517 · Cited by 21
Ebrahimi, S., Nataj, Z. E., Khodaverdian, S., Khamsavi, A., Abdi, Y., & Khajeh, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3009536 · Cited by 20
In-plane-gate a-IGZO thin-film transistor for high-sensitivity pH sensor applications
Pyo, J., & Cho, W.-J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.08.087 · Cited by 19
Self-citationPyo, J., & Cho, W.-J. (2018) · Japanese Journal of Applied Physics · doi:10.7567/jjap.57.04fp02 · Cited by 17
Self-citationLiao, W., Wei, W., Tong, Y., Wong, A., Chim, W. K., & Zhu, C. (2017) · IEEE Electron Device Letters · doi:10.1109/led.2017.2716959 · Cited by 16
Quantum capacitance-limited MoS 2 biosensors enable remote label-free enzyme measurements
Le, S. T., Guros, N. B., Bruce, R. C., Cardone, A., Amin, N. D., Zhang, S., Klauda, J. B., Pant, H. C., Richter, C. A., & Balijepalli, A. K. (2019) · Nanoscale · doi:10.1039/c9nr03171e · Cited by 17
Ahn, M., Lim, C.-M., & Cho, W.-J. (2017) · Semiconductor Science and Technology · doi:10.1088/1361-6641/aa5138 · Cited by 15
Self-citationCho, S.-K., & Cho, W.-J. (2020) · Thin Solid Films · doi:10.1016/j.tsf.2020.138083 · Cited by 16
Self-citationHigh Sensitivity of Dual Gate ISFETs Using HfO2 and HfO2/Y2O3 Gate Dielectrics
Bhatt, D., & Panda, S. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.1c00391 · Cited by 15
Stacked Top Gate Dielectrics in Dual Gate Ion Sensitive Field Effect Transistors: Role of Interfaces
Bhatt, D., Kumar, N. C., & Panda, S. (2019) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.9b00267 · Cited by 14
Dual-Gate MoS2FET With a Coplanar-Gate Engineering
(2015) · doi:10.1109/ted.2015.2504582 · Cited by 13
Optimum Functionalization of Si Nanowire FET for Electrical Detection of DNA Hybridization
Midahuen, R., Previtali, B., Fontelaye, C., Nonglaton, G., Stambouli, V., & Barraud, S. (2022) · IEEE Journal of the Electron Devices Society · doi:10.1109/jeds.2022.3166683 · Cited by 13
Jeon, J.-H., & Cho, W.-J. (2019) · IEEE Electron Device Letters · doi:10.1109/led.2018.2890741 · Cited by 13
Self-citationPanahi, A., Tabrizi, H. O., Mangannavar, P., Chebotarev, O., Fung, A., & Ghafar‐Zadeh, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3121339 · Cited by 14
Size Independent pH Sensitivity for Ion Sensitive FinFETs Down to 10 nm Width
Gupta, M., Santermans, S., Veloso, A., Tao, Z., Li, W., Hellings, G., Lagae, L., Roy, W. V., & Martens, K. M. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2912503 · Cited by 14
A numerical simulation tool for nanoscale ion‐sensitive field‐effect transistor
Abdolkader, T. M. (2016) · International Journal of Numerical Modelling Electronic Networks Devices and Fields · doi:10.1002/jnm.2170 · Cited by 10
Kim, Y.-U., & Cho, W.-J. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/acb0d9 · Cited by 10
Self-citationSensitivity Enhancement of Dual Gate Field-Effect Transistors Using Stacked Bottom Gate Dielectrics
Bhatt, D., & Panda, S. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00257 · Cited by 10
Ultrahigh-Sensitive CMOS pH Sensor Developed in the BEOL of Standard 28 nm UTBB FDSOI
Ayele, G. T., Monfray, S., Ecoffey, S., Bœuf, F., Cloarec, J., Drouin, D., & Souifi, A. (2018) · IEEE Journal of the Electron Devices Society · doi:10.1109/jeds.2018.2861622 · Cited by 14
Negative Capacitance Dual-Gated ISFETs as Ultra-Sensitive pH Sensors
Sakib, F. I., Hasan, M. A., Mohona, M. D., & Hossain, M. (2023) · ACS Omega · doi:10.1021/acsomega.3c05716 · Cited by 9
Hong, E.-K., & Cho, W.-J. (2018) · AIP Advances · doi:10.1063/1.5059376 · Cited by 8
Self-citationShafi, N., Bhat, A. M., Parmar, J. S., Sahu, C., & Periasamy, C. (2022) · Silicon · doi:10.1007/s12633-022-01709-4 · Cited by 10
Cao, X., Liu, H., Jiang, W., Ning, Z., Li, R., & Yu, D. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/8/085204 · Cited by 8
Ayele, G. T., Monfray, S., Bœuf, F., Cloarec, J., Ecoffey, S., Drouin, D., Puyoo, E., & Souifi, A. (2017) · European Solid-State Device Research Conference · doi:10.1109/essderc.2017.8066642 · Cited by 7
High sensitivity pH sensing on the BEOL of industrial FDSOI transistors
Rahhal, L., Ayele, G. T., Monfray, S., Cloarec, J., Fornacciari, B., Pardoux, É., Chevalier, C., Ecoffey, S., Drouin, D., Morin, P., et al. (2017) · Solid-State Electronics · doi:10.1016/j.sse.2017.05.005 · Cited by 8
Kim, Y.-U., & Cho, W.-J. (2022) · Chemosensors · doi:10.3390/chemosensors10040122 · Cited by 6
Self-citationWang, H., & Tang, N. (2021) · Materials Research Express · doi:10.1088/2053-1591/ac1d68 · Cited by 5
Midahuen, R., Previtali, B., Fontelaye, C., Nonglaton, G., Barraud, S., & Stambouli, V. (2021) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc53450.2021.9567751 · Cited by 6
Nazeer, T., & Ahsan, S. A. (2024) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.4c00650 · Cited by 5
Field Effect Transistor Technologies for Biological and Chemical Sensors
Salaün, A., Bihan, F. L., & Pichon, L. (2020) · Wiley eBooks · doi:10.1002/9781119587422.ch2 · Cited by 4
Garg, M., Chaubey, V. K., & Sinha, S. (2019) · International Conference on Internet of Everything, Microwave Engineering, Communication and Networks (IEMECON) · doi:10.1109/iemeconx.2019.8877019 · Cited by 4
Investigation of pH sensor based on liquid-solid dual-gated IGZO thin-film transistor
Cai, G., Yang, P., Wang, X., Pei, Y., & Wang, G. (2019) · Materials Research Express · doi:10.1088/2053-1591/ab2c93 · Cited by 5
Yarlagadda, N., Wadhwa, G., Kaur, P., Thakur, A., Singh, S. S., & Mani, P. (2025) · Micro and Nanostructures · doi:10.1016/j.micrna.2025.208286 · Cited by 3
Liquid Gate and Back Gate Capacitive Coupling Effects in pH Sensing Performance of FinFETs
Alharbi, A. G., & Shafi, N. (2022) · Silicon · doi:10.1007/s12633-022-01953-8 · Cited by 3
Novel Detection Methodology of Milk-Oligopeptides Fingerprints using Ion-Sensitive BioFET
Kumar, N., García, C. P., Dixit, A., Rezaei, A., & Georgiev, V. (2023) · IEEE BioSensors Conference (BioSensors) · doi:10.1109/biosensors58001.2023.10281172 · Cited by 3
Stambouli, V., Aldrin, K., & Bano, E. (2026) · Sensors · doi:10.3390/s26030857 · Cited by 2
Alepidis, M., Delacour, C., Bawedin, M., & Ionica, I. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115439 · Cited by 6
Midahuen, R., Previtali, B., Fontelaye, C., Nonglaton, G., Stambouli, V., & Barraud, S. (2021) · European Solid-State Device Research Conference · doi:10.1109/essderc53440.2021.9631772 · Cited by 1
Electrical readout strategies of GFET biosensors for real-world requirements
Geiwitz, M., Page, O. R., Nichols, M., Marello, T., Hoar, C., Akinwande, D., Meyer, M. M., & Burch, K. S. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118627 · Cited by 5
Jeon, J.-H., Park, J. T., & Cho, W.-J. (2019) · Joint International EUROSOI Workshop and International Conference on Ultimate Integration on Silicon · doi:10.1109/eurosoi-ulis45800.2019.9041867 · Cited by 1
Self-citationWang, Z., Gao, M., Wei, W., Liang, Y. C., & Zhu, C. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3586584 · Cited by 2
Tiwari, A., Sanjay, S., Mamun, N. B., Faruq, A., Hossain, M., & Bhat, N. (2026) · ACS Nano · doi:10.1021/acsnano.5c15447 · Cited by 1
Ayele, G. T. (2019) · theses.fr (ABES) · doi:10.70675/444bfcc6zefe5z4ce2zba7dz73ddc8a5bf57 · Cited by 2
Performance Analysis of FET-Based Nanoiosensors by Computational Method
Talukdar, K., & Malipatil, A. S. (2016) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-5225-1043-7.ch007
Otimização de transistores BESOI MOSFET como plataforma para aplicação em biossensores.
Yojo, L. S. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.3.2022.tde-20042022-084216
Super-Nernstian Floating-Extended Gate Ion Sensitive Field Effect Transistor for pH sensing
Tiwari, A., Sanjay, S., & Bhat, N. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325245
Ion Sensitive Field Effect Transistor for pH Sensing Application: A Simulation Based Analysis
Gajal, L., & Pandey, A. K. (2025) · Lecture notes in electrical engineering · doi:10.1007/978-3-031-84331-0_9
Metadata
- Authors
- Jang, H.-J., & Cho, W.-J.
- Affiliations
- Kwangwoon University (KR)
- Corresponding author
- Cho, Won-Ju
- Venue
- Scientific Reports
- Published
- 2014-06-13
- Volume
- 4
- Issue
- 1
- Pages
- 5284-5284
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC4055887
- OpenAlex
- W2032237132
- Semantic Scholar
- 02d62c28e412500b38196e905f387243ae84f8fb
- Cited by
- 103
- References
- 28
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 12 · 2020: 12 · 2019: 13 · 2018: 8 · 2017: 18 · 2016: 6 · 2015: 8 · 2014: 2
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Research Foundation
- National Research Foundation of Korea (2013R1A1A2A10011202, No. 2013R1A1A2A10011202)
- Ministry of Education, Science and Technology (2013R1A1A2A10011202)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- ion-sensitive field-effect transistor, dual-gate structure, capacitive coupling, ultra-thin body, thin-film transistors, leakage control, device stability, sensitivity enhancement, biosensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.