Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; none of the 24 sources its claims cite is checked for support yet.
Abstract
Ultra-thin-body dual-gate ISFET with enhanced sensitivity and stability via capacitive coupling.
Overview
CoChat Summary
TL;DR
This paper shows that making a dual-gate ISFET ultra-thin can substantially improve capacitive coupling, boosting pH sensitivity and reducing leakage-related instability. A 4.3 nm body device achieved 425.89 mV/pH sensitivity and better linearity, hysteresis, and drift than thicker-body devices.
Key findings
- The ultra-thin-body (UTB) DG ISFET with a 4.3 nm body achieved a sensitivity of 425.89 mV/pH, which the paper says is more than twice that of an 85 nm body device.
- For DG operation, sensitivity increased as body thickness decreased; by contrast, in SG operation the sensitivity stayed in a similar range of 39.82 to 47.19 mV/pH.
- Linearity improved with thinner bodies: 99.72% (±0.08%) at 4.3 nm, 98.24% (±0.32%) at 30 nm, and 97.69% (±0.96%) at 61 nm.
- The UTB device reduced leakage currents and made the experimental amplification factor nearly match the ideal one, with an error of 1.41%; thicker-body devices showed larger deviations and worse hysteresis/drift.
Methods
- The study fabricated DG ISFETs on fully depleted p-type (100) SOI substrates with a 107 nm top silicon layer and 224 nm BOX, then thinned the silicon using 2.38% TMAH etching to produce bodies including 4.3 nm, 30 nm, 61 nm, and 85 nm.
- Device geometry included a 10 μm × 10 μm active channel; sensing used a 23 nm SiO2 membrane, pH buffer solutions, and Ag/AgCl reference electrodes measured with a Hewlett-Packard 4156B analyzer.
- Analysis compared DG vs SG transfer behavior, extracted sensitivity, linearity, amplification factor, hysteresis width, and drift rate, and used ATLAS (Silvaco) simulations for coupling-ratio/body-thickness effects.
Limitations
- The paper explicitly notes that thick body devices suffer from inversion-lopsided coupling, leakage fluctuations, and unstable coupling ratios, which degrade performance; this is presented as a device limitation rather than a study design limitation.
- The Methods section states the body thickness of the thick-device comparison is important because the channel condition can affect whether the other interface is fully depleted; the text makes evident that results depend on specific fabricated SOI/SiO2 devices, so generalization to other materials or architectures is not directly established (inferred from the paper’s device-specific setup).
- Not stated in the paper.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
0 Valid · 0 Not valid · 15 Not checked · 63 Own results and interpretations
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The UTB of 4.3 nm serves to not only increase its sensitivity, but also to strongly suppress the leakage components, leading to a better stability of the DG ISFET.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The UTB of 4.3 nm serves to not only increase its sensitivity, but also to strongly suppress the leakage components, leading to a better stability of the DG ISFET.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Abstract
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The sensitivity of a 4.3-nm-thick UTB device is increased by more than twice, compared to an 85 nm body device, and greater stability improvements can be made in this geometrical property.”
- Also stated in: § Sensing performance of the DG ISFET · plain
“In aspect of the fact that the sensitivity is increased by more than twice, compared to an 85 nm body device, the body thickness effect cannot be ignored in the DG ISFET platform.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Sensing performance of the DG ISFET · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“while the secondary interface becomes either inversion or accumulation by the applied biases, an 85-nm body device reveals saturated or uneven shifts from the induced carriers.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Results > Electrical characteristics of the DG MOSFET
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“The other peculiar point in the plot is the shape of the leakage currents; they are randomly fluctuated with thin secondary inverted carriers20; this indicates that parallel shifts do not occur, with the secondary potential changes at regular intervals.”
§ Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body > Results > Electrical characteristics of the DG MOSFET
What the sources say
- Not checked — no full text of the sourcecites [20] Colinge J.-P. Transcoductance of silicon-on-insulator (SOI) MOSFET's. IEEE Electron Device Lett. EDL-6, 573– 574 (1985). source
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
47 more claims
Create a free account to see all 78 claims and to verify the 7 references still open.
- It may state two separate claims as one. 22
- The quote only partly states this claim. 3
- Probably not a substantial claim. 6
Citations
Cites
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Threshold voltage of thin-film Silicon-on-insulator (SOI) MOSFET's
Lim, H.-K., & Fossum, J. G. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21282 · Cited by 695
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Matsuo, T., & Esashi, M. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80006-6 · Cited by 343
Ultimately thin double-gate SOI MOSFETs
Ernst, T., Cristoloveanu, S., Ghibaudo, G., Ouisse, T., Horiguchi, S., Ono, Y., Takahashi, Y., & Murase, K. (2003) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2003.811371 · Cited by 245
A physical model for drift in pH ISFETs
Jamasb, S., Collins, S., & Smith, R. L. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00040-9 · Cited by 239
The role of buried OH sites in the response mechanism of inorganic-gate pH-sensitive ISFETs
Bousse, L., & Bergveld, P. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80028-1 · Cited by 198
ISFET Based Microsensors for Environmental Monitoring
Jimenez-Jorquera, C., Orozco, J., & Baldi, A. (2009) · Sensors · doi:10.3390/s100100061 · Cited by 184
Comparison of the hysteresis of Ta2O5 and Si3N4 pH-sensing insulators
Bousse, L., Mostarshed, S., van der Schoot, B., & de Rooij, N. F. (1994) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(94)87044-6 · Cited by 177
Dual‐Gate Thin‐Film Transistors, Integrated Circuits and Sensors
Spijkman, M., Myny, K., Smits, E. C. P., Heremans, P., Blom, P. W. M., & de Leeuw, D. M. (2011) · Advanced Materials · doi:10.1002/adma.201101493 · Cited by 176
Lee, J., Park, J.-S., Pyo, Y. S., Lee, D. B., Kim, E. H., Stryakhilev, D., Kim, T. W., Jin, D. U., & Mo, Y.-G. (2009) · Applied Physics Letters · doi:10.1063/1.3232179 · Cited by 168
Dual‐Gate Organic Field‐Effect Transistors as Potentiometric Sensors in Aqueous Solution
Spijkman, M., Brondijk, J. J., Geuns, T. C. T., Smits, E. C. P., Cramer, T., Zerbetto, F., Stoliar, P., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901830 · Cited by 154
Ultra-thin fully-depleted SOI MOSFETs: Special charge properties and coupling effects
Eminente, S., Cristoloveanu, S., Clerc, R., Ohata, A., & Ghibaudo, G. (2007) · Solid-State Electronics · doi:10.1016/j.sse.2007.01.016 · Cited by 139
Chou, J.-C., & Liao, L. P. (2004) · Thin Solid Films · doi:10.1016/j.tsf.2004.09.061 · Cited by 137
Beyond the Nernst-limit with dual-gate ZnO ion-sensitive field-effect transistors
Spijkman, M., Smits, E. C. P., Cillessen, J. F. M., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2011) · Applied Physics Letters · doi:10.1063/1.3546169 · Cited by 135
Chou, J. C., & Wang, Y. F. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00147-8 · Cited by 114
Gonçalves, D., Prazeres, D. M. F., Chu, V., & Conde, J. P. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.05.006 · Cited by 97
Huang, W., Besar, K., LeCover, R., Dulloor, P., Sinha, J., Martínez Hardigree, J. F., Pick, C., Swavola, J., Everett, A. D., Frechette, J., et al. (2014) · Chem. Sci. · doi:10.1039/c3sc52638k · Cited by 83
Creatinine sensitive biosensor based on ISFETs and creatinine deiminase immobilised in BSA membrane
Soldatkin, A. P. (2002) · Talanta · doi:10.1016/s0039-9140(02)00283-7 · Cited by 83
Jang, H.-J., Gu, J.-G., & Cho, W.-J. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.02.056 · Cited by 76
Self-citationChemical and biological sensors using polycrystalline silicon TFTs
Estrela, P., & Migliorato, P. (2006) · Journal of Materials Chemistry · doi:10.1039/b612469k · Cited by 56
Transconductance of Silicon-on-insulator (SOI) MOSFET's
Colinge, J.-P. (1985) · IEEE Electron Device Letters · doi:10.1109/edl.1985.26234 · Cited by 41
Correct biasing rules for virtual DG mode operation in SOI-MOSFETs
Ohata, A., Pretet, J., Cristoloveanu, S., & Zaslavsky, A. (2004) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2004.841273 · Cited by 35
Correct biasing rules for virtual DG mode operation in SOI--MOSFETs
(2005) · Cited by 30
Effect of the size of receptor in allergy detection using field effect transistor biosensor
Hideshima, S., Kuroiwa, S., Kimura, M., Cheng, S., & Ōsaka, T. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.07.113 · Cited by 17
Research works printed but not linked: 1
- Bergveld P. ISFET, theory and practice. Proceedings of the IEEE Sensor Conference Toronto, Ontario, Oct., 1– 26 (2003).
Cited by
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Singh, S., Anil, A. G., Kumar, V., Kapoor, D., Subramanian, S., Singh, J., & Ramamurthy, P. C. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2021.131996 · Cited by 295
Flexible Field-Effect Transistor-Type Sensors Based on Conjugated Molecules
Lee, Y. H., Jang, M., Lee, M. Y., Kweon, O. Y., & Oh, J. H. (2017) · Chem · doi:10.1016/j.chempr.2017.10.005 · Cited by 200
Qin, Y., Kwon, H.-J., Howlader, M. M. R., & Deen, M. J. (2015) · RSC Advances · doi:10.1039/c5ra11291e · Cited by 196
Lowe, B. M., Sun, K., Zeimpekis, I., Skylaris, C., & Green, N. G. (2017) · The Analyst · doi:10.1039/c7an00455a · Cited by 169
Metadata
- Authors
- Jang, H.-J., & Cho, W.-J.
- Affiliations
- Kwangwoon University (KR)
- Corresponding author
- Cho, Won-Ju
- Venue
- Scientific Reports
- Published
- 2014-06-13
- Volume
- 4
- Issue
- 1
- Pages
- 5284-5284
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC4055887
- OpenAlex
- W2032237132
- Semantic Scholar
- 02d62c28e412500b38196e905f387243ae84f8fb
- Cited by
- 103
- References
- 28
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 12 · 2020: 12 · 2019: 13 · 2018: 8 · 2017: 18 · 2016: 6 · 2015: 8 · 2014: 2
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Research Foundation
- National Research Foundation of Korea (2013R1A1A2A10011202, No. 2013R1A1A2A10011202)
- Ministry of Education, Science and Technology (2013R1A1A2A10011202)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- ion-sensitive field-effect transistor, dual-gate structure, capacitive coupling, ultra-thin body, thin-film transistors, leakage control, device stability, sensitivity enhancement, biosensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.