CoChat

Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body

Open access
Jang, Hyun-June, Cho, Won-Ju · 2014 · Scientific Reports

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; none of the 24 sources its claims cite is checked for support yet.

Abstract

Ultra-thin-body dual-gate ISFET with enhanced sensitivity and stability via capacitive coupling.

Overview

CoChat Summary

TL;DR

This paper shows that making a dual-gate ISFET ultra-thin can substantially improve capacitive coupling, boosting pH sensitivity and reducing leakage-related instability. A 4.3 nm body device achieved 425.89 mV/pH sensitivity and better linearity, hysteresis, and drift than thicker-body devices.

Key findings

  • The ultra-thin-body (UTB) DG ISFET with a 4.3 nm body achieved a sensitivity of 425.89 mV/pH, which the paper says is more than twice that of an 85 nm body device.
  • For DG operation, sensitivity increased as body thickness decreased; by contrast, in SG operation the sensitivity stayed in a similar range of 39.82 to 47.19 mV/pH.
  • Linearity improved with thinner bodies: 99.72% (±0.08%) at 4.3 nm, 98.24% (±0.32%) at 30 nm, and 97.69% (±0.96%) at 61 nm.
  • The UTB device reduced leakage currents and made the experimental amplification factor nearly match the ideal one, with an error of 1.41%; thicker-body devices showed larger deviations and worse hysteresis/drift.

Methods

  • The study fabricated DG ISFETs on fully depleted p-type (100) SOI substrates with a 107 nm top silicon layer and 224 nm BOX, then thinned the silicon using 2.38% TMAH etching to produce bodies including 4.3 nm, 30 nm, 61 nm, and 85 nm.
  • Device geometry included a 10 μm × 10 μm active channel; sensing used a 23 nm SiO2 membrane, pH buffer solutions, and Ag/AgCl reference electrodes measured with a Hewlett-Packard 4156B analyzer.
  • Analysis compared DG vs SG transfer behavior, extracted sensitivity, linearity, amplification factor, hysteresis width, and drift rate, and used ATLAS (Silvaco) simulations for coupling-ratio/body-thickness effects.

Limitations

  • The paper explicitly notes that thick body devices suffer from inversion-lopsided coupling, leakage fluctuations, and unstable coupling ratios, which degrade performance; this is presented as a device limitation rather than a study design limitation.
  • The Methods section states the body thickness of the thick-device comparison is important because the channel condition can affect whether the other interface is fully depleted; the text makes evident that results depend on specific fabricated SOI/SiO2 devices, so generalization to other materials or architectures is not directly established (inferred from the paper’s device-specific setup).
  • Not stated in the paper.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/srep05284

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 A cross-sectional schematic image of the DG ISFET.
Figure 1 A cross-sectional schematic image of the DG ISFET.CC BY · PubMed Central
Figure 2 Transfer curves measured by primary gate with the constant secondary gate biases for (a) an 85-nm-thick body, and (b) 4.3-nm-thick body devices. The drain bias was set at 50 mV.
Figure 2 Transfer curves measured by primary gate with the constant secondary gate biases for (a) an 85-nm-thick body, and (b) 4.3-nm-thick body devices. The drain bias was set at 50 mV.CC BY · PubMed Central
Figure 3 (a) VS versus plot of an 85-nm-thick body, extracted from Figure 2a. (b) VS versus and the reciprocal curve of versus VP of an 85-nm-thick body and a 4.3-nm-thick body devices.
Figure 3 (a) VS versus plot of an 85-nm-thick body, extracted from Figure 2a. (b) VS versus and the reciprocal curve of versus VP of an 85-nm-thick body and a 4.3-nm-thick body devices.CC BY · PubMed Central
Figure 4 TCAD device (ATLAS, Silvaco™) simulation results of the ideal AF, based on various fabrication elements as a function of body thickness. (a) dielectric constant, (b) BOX, and (c) body doping concentration influence.
Figure 4 TCAD device (ATLAS, Silvaco™) simulation results of the ideal AF, based on various fabrication elements as a function of body thickness. (a) dielectric constant, (b) BOX, and (c) body doping concentration influence.CC BY · PubMed Central
Figure 5 Transfer curves of (a) 85-nm-, (b) 61-nm-, (c) 30-nm-, and (d) 4.3-nm-thick DG ISFETs for the various pH buffer solutions. The drain bias is set at 50 mV.
Figure 5 Transfer curves of (a) 85-nm-, (b) 61-nm-, (c) 30-nm-, and (d) 4.3-nm-thick DG ISFETs for the various pH buffer solutions. The drain bias is set at 50 mV.CC BY · PubMed Central
Figure 6 (a) Linearity and (b) experimental AF distribution depending on body thickness, extracted from various IR.
Figure 6 (a) Linearity and (b) experimental AF distribution depending on body thickness, extracted from various IR.CC BY · PubMed Central
Figure 7 Transfer curves of an 85-nm body device according to applied secondary gate voltage of (a) 0 V, (b) −1 V, and (c) −2 V. The drain bias is set at 50 mV.
Figure 7 Transfer curves of an 85-nm body device according to applied secondary gate voltage of (a) 0 V, (b) −1 V, and (c) −2 V. The drain bias is set at 50 mV.CC BY · PubMed Central
Figure 8 Sensitivity and linearity distribution of an 85-nm body device depending on the negative VS, extracted from various IR.
Figure 8 Sensitivity and linearity distribution of an 85-nm body device depending on the negative VS, extracted from various IR.CC BY · PubMed Central
Figure 9 (a) Drift distribution measured by the DG operation in the pH 7 buffer solution for 12 hours. (b) Hysteresis distribution for three buffer solutions, measured by the DG operation mode. All evaluations were repeated 5 times.
Figure 9 (a) Drift distribution measured by the DG operation in the pH 7 buffer solution for 12 hours. (b) Hysteresis distribution for three buffer solutions, measured by the DG operation mode. All evaluations were repeated 5 times.CC BY · PubMed Central
Figure 10 Hysteresis width of (a) an 85-nm body and (b) a 4.3-nm body device, respectively.
Figure 10 Hysteresis width of (a) an 85-nm body and (b) a 4.3-nm body device, respectively.CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 15 Not checked · 63 Own results and interpretations

47 more claims

Create a free account to see all 78 claims and to verify the 7 references still open.

See all claims — free account
  • It may state two separate claims as one. 22
  • The quote only partly states this claim. 3
  • Probably not a substantial claim. 6

Create a free account to see these claims.

Citations

Cites

Research works printed but not linked: 1

  1. Bergveld P. ISFET, theory and practice. Proceedings of the IEEE Sensor Conference Toronto, Ontario, Oct., 1– 26 (2003).

Cited by

See all 103

Metadata

Authors
Jang, H.-J., & Cho, W.-J.
Affiliations
Kwangwoon University (KR)
Corresponding author
Cho, Won-Ju
Venue
Scientific Reports
Published
2014-06-13
Volume
4
Issue
1
Pages
5284-5284
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2032237132
Cited by
103
References
28
Citations by year
2026: 3 · 2025: 5 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 12 · 2020: 12 · 2019: 13 · 2018: 8 · 2017: 18 · 2016: 6 · 2015: 8 · 2014: 2
FWCI
7.85
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • National Research Foundation
  • National Research Foundation of Korea (2013R1A1A2A10011202, No. 2013R1A1A2A10011202)
  • Ministry of Education, Science and Technology (2013R1A1A2A10011202)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
ion-sensitive field-effect transistor, dual-gate structure, capacitive coupling, ultra-thin body, thin-film transistors, leakage control, device stability, sensitivity enhancement, biosensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.