The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluidsThe Science and Application of Droplets in Microfluidic Devices.Electronic supplementary information (ESI) available: five video clips showing: high-speed transport of a droplet of blood across 4 electrodes; sample injection into an on-chip reservoir using an external pipette; droplet formation from an on-chip reservoir using only electrowetting forces; droplets moving in-phase on a 3-phase transport bus; and a pipelined glucose assay, showing sample and reagent droplet formation, mixing, splitting and colorimetric reaction. See http://www.rsc.org/suppdata/lc/b4/b403341h/
Abstract
Clinical diagnostics is one of the most promising applications for microfluidic lab-on-a-chip systems, especially in a point-of-care setting. Conventional microfluidic devices are usually based on continuous-flow in microchannels, and offer little flexibility in terms of reconfigurability and scalability. Handling of real physiological samples has also been a major challenge in these devices. We present an alternative paradigm--a fully integrated and reconfigurable droplet-based "digital" microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. The microdroplets, which act as solution-phase reaction chambers, are manipulated using the electrowetting effect. Reliable and repeatable high-speed transport of microdroplets of human whole blood, serum, plasma, urine, saliva, sweat and tear, is demonstrated to establish the basic compatibility of these physiological fluids with the electrowetting platform. We further performed a colorimetric enzymatic glucose assay on serum, plasma, urine, and saliva, to show the feasibility of performing bioassays on real samples in our system. The concentrations obtained compare well with those obtained using a reference method, except for urine, where there is a significant difference due to interference by uric acid. A lab-on-a-chip architecture, integrating previously developed digital microfluidic components, is proposed for integrated and automated analysis of multiple analytes on a monolithic device. The lab-on-a-chip integrates sample injection, on-chip reservoirs, droplet formation structures, fluidic pathways, mixing areas and optical detection sites, on the same substrate. The pipelined operation of two glucose assays is shown on a prototype digital microfluidic lab-on-chip, as a proof-of-concept.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Rapid droplet mixers for digital microfluidic systems
Paik, P., Pamula, V. K., & Fair, R. B. (2003) · Lab Chip · doi:10.1039/b307628h · Cited by 497
Self-citationMicrofabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
Tüdős, A. J., Besselink, G. A. J., & Schasfoort, R. B. M. (2001) · Lab Chip · doi:10.1039/b106958f · Cited by 426
Paik, P., Pamula, V. K., Pollack, M. G., & Fair, R. B. (2003) · Lab on a Chip · doi:10.1039/b210825a · Cited by 327
Self-citationSrinivasan, V., Pamula, V. K., Pollack, M. C., & Fair, R. B. (2003) · Cited by 122
Self-citation
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Flexible Electronics: The Next Ubiquitous Platform
Nathan, A., Ahnood, A., Cole, M. T., Lee, S., Suzuki, Y., Hiralal, P., Bonaccorso, F., Hasan, T., Garcia-Gancedo, L., Dyadyusha, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2190168 · Cited by 1,000
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Clausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Self-citationSaliva diagnostics – Current views and directions
Kaczor-Urbanowicz, K. E., Martin Carreras-Presas, C., Aro, K., Tu, M., Garcia-Godoy, F., & Wong, D. T. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370216681550 · Cited by 472
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Colloidal Self-Assembly Approaches to Smart Nanostructured Materials
Li, Z., Fan, Q., & Yin, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00482 · Cited by 468
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Harrach, M. F., & Drossel, B. (2014) · The Journal of Chemical Physics · doi:10.1063/1.4872239 · Cited by 395
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Wettability Switching Techniques on Superhydrophobic Surfaces
Verplanck, N., Coffinier, Y., Thomy, V., & Boukherroub, R. (2007) · Nanoscale Research Letters · doi:10.1007/s11671-007-9102-4 · Cited by 310
Monodispersed microfluidic droplet generation by shear focusing microfluidic device
Tan, Y.-C., Cristini, V., & Lee, A. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.06.008 · Cited by 305
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Droplet digital PCR of viral DNA/RNA, current progress, challenges, and future perspectives
Kojabad, A. A., Farzanehpour, M., Galeh, H. E. G., Dorostkar, R., Jafarpour, A., Bolandian, M., & Nodooshan, M. M. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26846 · Cited by 297
Moon, H., Wheeler, A. R., Garrell, R. L., Loo, J. A., & Kim, C.-J. ?. (2006) · Lab on a Chip · doi:10.1039/b601954d · Cited by 296
Heterogeneous immunoassays using magnetic beads on a digital microfluidic platform
Sista, R. S., Eckhardt, A. E., Srinivasan, V., Pollack, M. G., Palanki, S., & Pamula, V. K. (2008) · Lab on a Chip · doi:10.1039/b807855f · Cited by 294
Self-citationFlexible two-dimensional indium tin oxide fabricated using a liquid metal printing technique
Datta, R. S., Syed, N., Zavabeti, A., Jannat, A., Mohiuddin, M., Rokunuzzaman, M., Yue Zhang, B., Rahman, M. A., Atkin, P., Messalea, K. A., et al. (2020) · Nature Electronics · doi:10.1038/s41928-019-0353-8 · Cited by 289
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Ultrahigh-throughput–directed enzyme evolution by absorbance-activated droplet sorting (AADS)
Gielen, F., Hours, R., Emond, S., Fischlechner, M., Schell, U., & Hollfelder, F. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1606927113 · Cited by 269
Molecular Structure and Dynamics in Thin Water Films at the Silica and Graphite Surfaces
Argyris, D., Tummala, N. R., Striolo, A., & Cole, D. R. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp803234a · Cited by 263
Development and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
Digital Microfluidics with In-Line Sample Purification for Proteomics Analyses with MALDI-MS
Wheeler, A. R., Moon, H., Bird, C. A., Ogorzalek Loo, R. R., Kim, C.-J. “. J. ”., Loo, J. A., & Garrell, R. L. (2005) · Analytical Chemistry · doi:10.1021/ac048754+ · Cited by 255
Choi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K. (2012) · Lab on a Chip · doi:10.1039/c2lc21203j · Cited by 77
Metadata
- Authors
- Srinivasan, V., Pamula, V. K., & Fair, R. B.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 4
- Pages
- 310
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1902734869
- Cited by
- 1,066
- References
- 9
- FWCI
- 38.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.