The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Inertial microfluidics
Abstract
Despite the common wisdom that inertia does not contribute to microfluidic phenomena, recent work has shown a variety of useful effects that depend on fluid inertia for applications in enhanced mixing, particle separation, and bioparticle focusing. Due to the robust, fault-tolerant physical effects employed and high rates of operation, inertial microfluidic systems are poised to have a critical impact on high-throughput separation applications in environmental cleanup and physiological fluids processing, as well as bioparticle focusing applications in clinical diagnostics. In this review I will discuss the recent accelerated progress in developing prototype inertial microfluidic systems for a variety of applications and attempt to clarify the fundamental fluid dynamic effects that are being exploited. Finally, since this a nascent area of research, I will suggest some future promising directions exploiting fluid inertia on the microscale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationBerger, S. A., Talbot, L., & Yao, L. S. (1983) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.15.010183.002333 · Cited by 1,363
Radial Particle Displacements in Poiseuille Flow of Suspensions
SEGRÉ, G., & SILBERBERG, A. (1961) · Nature · doi:10.1038/189209a0 · Cited by 1,206
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Inertial migration of rigid spheres in two-dimensional unidirectional flows
Ho, B. P., & Leal, L. G. (1974) · Journal of Fluid Mechanics · doi:10.1017/s0022112074001431 · Cited by 821
Inertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
Continuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Mixing, Chaotic Advection, and Turbulence
Ottino, J. M. (1990) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.22.010190.001231 · Cited by 612
Controlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Self-citation
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Self-citationHydrodynamic stretching of single cells for large population mechanical phenotyping
Gossett, D. R., Tse, H. T. K., Lee, S. A., Ying, Y., Lindgren, A. G., Yang, O. O., Rao, J., Clark, A. T., & Di Carlo, D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200107109 · Cited by 775
Self-citationIsolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationDesign of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationInertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Circulating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
Size-selective collection of circulating tumor cells using Vortex technology
Sollier, E., Go, D. E., Che, J., Gossett, D. R., O'Byrne, S., Weaver, W. M., Kummer, N., Rettig, M., Goldman, J., Nickols, N., et al. (2014) · Lab Chip · doi:10.1039/c3lc50689d · Cited by 498
Self-citationCell separation using tilted-angle standing surface acoustic waves
Ding, X., Peng, Z., Lin, S.-C. S., Geri, M., Li, S., Li, P., Chen, Y., Dao, M., Suresh, S., & Huang, T. J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1413325111 · Cited by 490
Wörner, M. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0940-8 · Cited by 438
Moon, H.-S., Kwon, K., Kim, S.-I., Han, H., Sohn, J., Lee, S., & Jung, H.-I. (2011) · Lab on a Chip · doi:10.1039/c0lc00345j · Cited by 437
Rapid prototyping polymers for microfluidic devices and high pressure injections
Sollier, E., Murray, C., Maoddi, P., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20514e · Cited by 407
Self-citationHydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
High-throughput single-microparticle imaging flow analyzer
Goda, K., Ayazi, A., Gossett, D. R., Sadasivam, J., Lonappan, C. K., Sollier, E., Fard, A. M., Hur, S. C., Adam, J., Murray, C., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204718109 · Cited by 384
Self-citationSheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368
Self-citationBhagat, A. A. S., Hou, H. W., Li, L. D., Lim, C. T., & Han, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00633e · Cited by 350
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
Ahn, J. C., Teng, P., Chen, P., Posadas, E., Tseng, H., Lu, S. C., & Yang, J. D. (2021) · Hepatology · doi:10.1002/hep.31165 · Cited by 338
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Continuous scalable blood filtration device using inertial microfluidics
Mach, A. J., & Di Carlo, D. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22833 · Cited by 334
Self-citationIndustrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Yang, S., Kim, J. Y., Lee, S. J., Lee, S. S., & Kim, J. M. (2011) · Lab Chip · doi:10.1039/c0lc00102c · Cited by 306
Kemna, E. W. M., Schoeman, R. M., Wolbers, F., Vermes, I., Weitz, D. A., & van den Berg, A. (2012) · Lab on a Chip · doi:10.1039/c2lc00013j · Cited by 303
Double spiral microchannel for label-free tumor cell separation and enrichment
Sun, J., Li, M., Liu, C., Zhang, Y., Liu, D., Liu, W., Hu, G., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40679a · Cited by 293
Particle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
Automated cellular sample preparation using a Centrifuge-on-a-Chip
Mach, A. J., Kim, J. H., Arshi, A., Hur, S. C., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20330d · Cited by 280
Self-citationGuan, G., Wu, L., Bhagat, A. A., Li, Z., Chen, P. C. Y., Chao, S., Ong, C. J., & Han, J. (2013) · Scientific Reports · doi:10.1038/srep01475 · Cited by 279
A comparison of microfluidic methods for high-throughput cell deformability measurements
Urbanska, M., Muñoz, H. E., Shaw Bagnall, J., Otto, O., Manalis, S. R., Di Carlo, D., & Guck, J. (2020) · Nature Methods · doi:10.1038/s41592-020-0818-8 · Cited by 277
Self-citationRecent progress of particle migration in viscoelastic fluids
Yuan, D., Zhao, Q., Yan, S., Tang, S.-Y., Alici, G., Zhang, J., & Li, W. (2018) · Lab on a Chip · doi:10.1039/c7lc01076a · Cited by 258
Droplet-based single cell RNAseq tools: a practical guide
Salomon, R., Kaczorowski, D., Valdes-Mora, F., Nordon, R. E., Neild, A., Farbehi, N., Bartonicek, N., & Gallego-Ortega, D. (2019) · Lab on a Chip · doi:10.1039/c8lc01239c · Cited by 109
Metadata
- Authors
- Di Carlo, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 21
- Pages
- 3038
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W4253260323
- Cited by
- 1,627
- References
- 20
- FWCI
- 26.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.