The DOI matches its Crossref record; 104 of the 104 references it cites were found in a registry or an index.
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Open accessAbstract
This critical review evaluates progress toward viable point-of-care protein biomarker measurements for cancer detection and diagnostics. The ability to measure panels of specific, selective cancer biomarker proteins in physicians' surgeries and clinics has the potential to revolutionize cancer detection, monitoring, and therapy. The dream envisions reliable, cheap, automated, technically undemanding devices that can analyze a patient's serum or saliva in a clinical setting, allowing on-the-spot diagnosis. Existing commercial products for protein assays are reliable in laboratory settings, but have limitations for point-of-care applications. A number of ultrasensitive immunosensors and some arrays have been developed, many based on nanotechnology. Multilabel detection coupled with high capture molecule density in immunosensors and arrays seems to be capable of detecting a wide range of protein concentrations with sensitivity ranging into the sub pg mL(-1) level. Multilabel arrays can be designed to detect both high and ultralow abundance proteins in the same sample. However, only a few of the newer ultrasensitive methods have been evaluated with real patient samples, which is key to establishing clinical sensitivity and selectivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanahan, D., & Weinberg, R. A. (2000) · Cell · doi:10.1016/s0092-8674(00)81683-9 · Cited by 29,219
Sørlie, T., Perou, C. M., Tibshirani, R., Aas, T., Geisler, S., Johnsen, H., Hastie, T., Eisen, M. B., van de Rijn, M., Jeffrey, S. S., et al. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191367098 · Cited by 10,938
Gene expression profiling predicts clinical outcome of breast cancer
van 't Veer, L. J., Dai, H., van de Vijver, M. J., He, Y. D., Hart, A. A. M., Mao, M., Peterse, H. L., van der Kooy, K., Marton, M. J., Witteveen, A. T., et al. (2002) · Nature · doi:10.1038/415530a · Cited by 9,536
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Biomarkers in Cancer Staging, Prognosis and Treatment Selection
Ludwig, J. A., & Weinstein, J. N. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1739 · Cited by 1,666
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Application of Nanoparticles in Electrochemical Sensors and Biosensors
Luo, X., Morrin, A., Killard, A. J., & Smyth, M. R. (2006) · Electroanalysis · doi:10.1002/elan.200503415 · Cited by 1,318
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Sawyers, C. L. (2008) · Nature · doi:10.1038/nature06913 · Cited by 983
Paweletz, C. P., Charboneau, L., Bichsel, V. E., Simone, N. L., Chen, T., Gillespie, J. W., Emmert-Buck, M. R., Roth, M. J., Petricoin III, E. F., & Liotta, L. A. (2001) · Oncogene · doi:10.1038/sj.onc.1204265 · Cited by 956
Prostate-specific antigen and prostate cancer: prediction, detection and monitoring
Lilja, H., Ulmert, D., & Vickers, A. J. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2351 · Cited by 921
Proteomic applications for the early detection of cancer
Wulfkuhle, J. D., Liotta, L. A., & Petricoin, E. F. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1043 · Cited by 907
Li, J., Zhang, Z., Rosenzweig, J., Wang, Y. Y., & Chan, D. W. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.8.1296 · Cited by 893
Haab, B. B., Dunham, M. J., & Brown, P. O. (2001) · Genome Biology · doi:10.1186/gb-2001-2-2-research0004 · Cited by 892
Mining the plasma proteome for cancer biomarkers
Hanash, S. M., Pitteri, S. J., & Faca, V. M. (2008) · Nature · doi:10.1038/nature06916 · Cited by 891
Nanomaterial-based electrochemical biosensors
Wang, J. (2005) · The Analyst · doi:10.1039/b414248a · Cited by 881
Strategies for discovering novel cancer biomarkers through utilization of emerging technologies
Kulasingam, V., & Diamandis, E. P. (2008) · Nature Clinical Practice Oncology · doi:10.1038/ncponc1187 · Cited by 771
Drivers of biodiagnostic development
Giljohann, D. A., & Mirkin, C. A. (2009) · Nature · doi:10.1038/nature08605 · Cited by 749
Weston, A. D., & Hood, L. (2004) · Journal of Proteome Research · doi:10.1021/pr0499693 · Cited by 731
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
Patolsky, F., Zheng, G., & Lieber, C. M. (2006) · Analytical Chemistry · doi:10.1021/ac069419j · Cited by 710
Mechanisms of Disease: oncogene addiction—a rationale for molecular targeting in cancer therapy
Weinstein, I. B., & Joe, A. K. (2006) · Nature Clinical Practice Oncology · doi:10.1038/ncponc0558 · Cited by 705
Nanomaterial-based Electrochemical Biosensors
Şensoy, K. G., Akpınar, F., & Muti, M. (2024) · Current Nanoscience · doi:10.2174/1573413718666220819143711 · Cited by 701
Interleukin-8 and human cancer biology
Xie, K. (2001) · Cytokine & Growth Factor Reviews · doi:10.1016/s1359-6101(01)00016-8 · Cited by 689
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Self-citationWang, J., Liu, G., & Jan, M. R. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031723w · Cited by 682
Smith, R. A., Cokkinides, V., Brooks, D., Saslow, D., & Brawley, O. W. (2010) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20063 · Cited by 660
Lahiri, J., Isaacs, L., Tien, J., & Whitesides, G. M. (1999) · Analytical Chemistry · doi:10.1021/ac980959t · Cited by 601
McDonnell, J. M. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00251-9 · Cited by 594
Multiplexed protein profiling on microarrays by rolling-circle amplification
Schweitzer, B., Roberts, S., Grimwade, B., Shao, W., Wang, M., Fu, Q., Shu, Q., Laroche, I., Zhou, Z., Tchernev, V. T., et al. (2002) · Nature Biotechnology · doi:10.1038/nbt0402-359 · Cited by 573
Biosensors for cancer markers diagnosis
Tothill, I. E. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.015 · Cited by 552
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Mani, V., Chikkaveeraiah, B. V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800863w · Cited by 532
Self-citationCarbon Nanotubes for Electronic and Electrochemical Detection of Biomolecules
Kim, S. N., Rusling, J. F., & Papadimitrakopoulos, F. (2007) · Advanced Materials · doi:10.1002/adma.200700665 · Cited by 502
Self-citationIn Situ Assembly of Colloidal Particles into Miniaturized Biosensors
Velev, O. D., & Kaler, E. W. (1999) · Langmuir · doi:10.1021/la981729c · Cited by 472
Nanomaterial‐Based Amplified Transduction of Biomolecular Interactions
Wang, J. (2005) · Small · doi:10.1002/smll.200500214 · Cited by 424
St. John, M. A. R., Li, Y., Zhou, X., Denny, P., Ho, C.-M., Montemagno, C., Shi, W., Qi, F., Wu, B., Sinha, U., et al. (2004) · Archives of Otolaryngology–Head & Neck Surgery · doi:10.1001/archotol.130.8.929 · Cited by 422
Multiplexed Detection of Protein Cancer Markers with Biobarcoded Nanoparticle Probes
Stoeva, S. I., Lee, J.-S., Smith, J. E., Rosen, S. T., & Mirkin, C. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0613106 · Cited by 419
Trends in biomarker research for cancer detection
Srinivas, P. R., Kramer, B. S., & Srivastava, S. (2001) · The Lancet Oncology · doi:10.1016/s1470-2045(01)00560-5 · Cited by 411
Mandrekar, S. J., & Sargent, D. J. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2009.22.3701 · Cited by 404
An Electrochemical Metalloimmunoassay Based on a Colloidal Gold Label
Dequaire, M., Degrand, C., & Limoges, B. (2000) · Analytical Chemistry · doi:10.1021/ac000781m · Cited by 379
Malhotra, R., Patel, V., Vaqué, J. P., Gutkind, J. S., & Rusling, J. F. (2010) · Analytical Chemistry · doi:10.1021/ac902802b · Cited by 361
Self-citationGervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Adams, J., Carder, P. J., Downey, S. E., Forbes, M. A., MacLennan, K. A., Allgar, V. L., Kaufman, S., Hallam, S., Bicknell, R., Walker, J. J., et al. (2000) · PubMed · Cited by 339
Leethanakul, C., Patel, V., Gillespie, J., Pallente, M., Ensley, J. F., Koontongkaew, S., Liotta, L. A., Emmert-Buck, M., & Gutkind, J. S. (2000) · Oncogene · doi:10.1038/sj.onc.1203703 · Cited by 295
Self-citationRecent Developments in Protein Microarray Technology
Wilson, D. S., & Nock, S. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390150 · Cited by 294
Progress in protein and antibody microarray technology
Angenendt, P. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03392-1 · Cited by 289
Deiss, F., LaFratta, C. N., Symer, M., Blicharz, T. M., Sojic, N., & Walt, D. R. (2009) · Journal of the American Chemical Society · doi:10.1021/ja901876z · Cited by 269
Electrochemical Sensor for Multiplex Biomarkers Detection
Wei, F., Patel, P., Liao, W., Chaudhry, K., Zhang, L., Arellano-Garcia, M., Hu, S., Elashoff, D., Zhou, H., Shukla, S., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-0050 · Cited by 257
Electrochemical Immunosensors for the Simultaneous Detection of Two Tumor Markers
Wilson, M. S. (2005) · Analytical Chemistry · doi:10.1021/ac0485278 · Cited by 245
Human papillomavirus in cervical and head-and-neck cancer
Psyrri, A., & DiMaio, D. (2008) · Nature Clinical Practice Oncology · doi:10.1038/ncponc0984 · Cited by 243
Sehr, P., Zumbach, K., & Pawlita, M. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00376-3 · Cited by 222
An immunological Interleukine-6 capacitive biosensor using perturbation with a potentiostatic step
Berggren, C., Bjarnason, B., & Johansson, G. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00058-x · Cited by 212
Smith, R. A., Cokkinides, V., & Brawley, O. W. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0017 · Cited by 211
Cancer BiomarkersAn Invitation to the Table
Dalton, W. S., & Friend, S. H. (2006) · Science · doi:10.1126/science.1125948 · Cited by 202
Nishizuka, S., Chen, S.-T., Gwadry, F. G., Alexander, J., Major, S. M., Scherf, U., Reinhold, W. C., Waltham, M. C., Charboneau, L., Young, L., et al. (2003) · PubMed · Cited by 202
Development of biosensors for cancer clinical testing
Rasooly, A., & Jacobson, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.003 · Cited by 200
Patel, V., Hood, B. L., Molinolo, A. A., Lee, N. H., Conrads, T. P., Braisted, J. C., Krizman, D. B., Veenstra, T. D., & Gutkind, J. S. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-1497 · Cited by 192
Self-citationProteomic patterns: their potential for disease diagnosis
Xiao, Z., Prieto, D., Conrads, T. P., Veenstra, T. D., & Issaq, H. J. (2005) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2004.10.010 · Cited by 188
Kim, D., Daniel, W. L., & Mirkin, C. A. (2009) · Analytical Chemistry · doi:10.1021/ac9018389 · Cited by 174
Kojima, K., Hiratsuka, A., Suzuki, H., Yano, K., Ikebukuro, K., & Karube, I. (2003) · Analytical Chemistry · doi:10.1021/ac0257391 · Cited by 167
Detection of picomolar levels of interleukin-8 in human saliva by SPR
Yang, C.-Y., Brooks, E., Li, Y., Denny, P., Ho, C.-M., Qi, F., Shi, W., Wolinsky, L., Wu, B., Wong, D. T. W., et al. (2005) · Lab on a Chip · doi:10.1039/b504737d · Cited by 165
Serum levels of interleukin-6 in patients with primary head and neck squamous cell carcinoma.
Riedel, F., Zaiss, I., Herzog, D., Götte, K., Naim, R., & Hörmann, K. (2005) · PubMed · Cited by 162
The p53 network in head and neck cancer
Gasco, M., & Crook, T. (2003) · Oral Oncology · doi:10.1016/s1368-8375(02)00163-x · Cited by 160
Mass Spectrometry–Based Biomarker Discovery: Toward a Global Proteome Index of Individuality
Hawkridge, A. M., & Muddiman, D. C. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112942 · Cited by 160
Chikkaveeraiah, B. V., Bhirde, A. A., Malhotra, R., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · Analytical Chemistry · doi:10.1021/ac9018022 · Cited by 151
Self-citationOrchekowski, R. P., Hamelinck, D., Li, L., Gliwa, E., VanBrocklin, M. W., Marrero, J. A., Woude, G. F. V., Feng, Z., Brand, R. E., & Haab, B. B. (2005) · Cancer Research · doi:10.1158/0008-5472.can-05-1436 · Cited by 148
Electrochemical Multianalyte Immunoassays Using an Array-Based Sensor
Wilson, M. S., & Nie, W. (2006) · Analytical Chemistry · doi:10.1021/ac0518452 · Cited by 144
Photoaptamer arrays applied to multiplexed proteomic analysis
Bock, C., Coleman, M., Collins, B. D., Davis, J., Foulds, G., Gold, L., Greef, C., Heil, J., Heilig, J. S., Hicke, B. J., et al. (2004) · PROTEOMICS · doi:10.1002/pmic.200300631 · Cited by 144
Zhou, H., Bouwman, K., Schotanus, M. P., Verweij, C., Marrero, J. A., Dillon, D., Costa, J. C., Lizardi, P. M., & Haab, B. B. (2004) · Genome biology · doi:10.1186/gb-2004-5-4-r28 · Cited by 142
Microarray methods for protein biomarker detection
Lee, H. J., Wark, A. W., & Corn, R. M. (2008) · The Analyst · doi:10.1039/b717527b · Cited by 142
Nanoparticle‐Based Electrochemical Bioassays of Proteins
Wang, J. (2007) · Electroanalysis · doi:10.1002/elan.200603789 · Cited by 138
Urine biomarkers in prostate cancer
Ploussard, G., & TAILLE, A. D. L. (2010) · Nature Reviews Urology · doi:10.1038/nrurol.2009.261 · Cited by 137
Prostate specific antigen: biology, biochemistry and available commercial assays
Ward, A. M., Catto, J. W. F., & Hamdy, F. C. (2001) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563011901055 · Cited by 136
Development of Immunosensors Using Carbon Nanotubes
Veetil, J. V., & Ye, K. (2007) · Biotechnology Progress · doi:10.1021/bp0602395 · Cited by 130
Williams, T. I., Toups, K. L., Saggese, D. A., Kalli, K. R., Cliby, W. A., & Muddiman, D. C. (2007) · Journal of Proteome Research · doi:10.1021/pr070041v · Cited by 128
Ultrasensitive assays for proteins
Zhang, H., Zhao, Q., Li, X., & Le, X. C. (2007) · The Analyst · doi:10.1039/b704256f · Cited by 127
Challenges for Biomarkers in Cancer Detection
Wagner, P. D., Verma, M., & Srivastava, S. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1318.003 · Cited by 123
Munge, B. S., Krause, C. E., Malhotra, R., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.02.044 · Cited by 117
Self-citationKeynote review: Recent advances in biomarkers for cancer diagnosis and treatment
Manne, U., Srivastava, R.-G., & Srivastava, S. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03487-2 · Cited by 110
Teramura, Y., Arima, Y., & Iwata, H. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.07.032 · Cited by 105
Oral Fluid Nanosensor Test (OFNASET) with Advanced Electrochemical‐Based Molecular Analysis Platform
Gau, V., & Wong, D. T. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.005 · Cited by 100
Wei, F., Liao, W., Xu, Z., Yang, Y., Wong, D. T., & Ho, C. (2009) · Small · doi:10.1002/smll.200900369 · Cited by 96
Konry, T., Hayman, R. B., & Walt, D. R. (2009) · Analytical Chemistry · doi:10.1021/ac900694y · Cited by 82
Choi, J., Kang, D.-Y., Jang, Y.-H., Kim, H.-H., Min, J., & Oh, B. (2007) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2007.05.057 · Cited by 78
Advances, Challenges, and Limitations in Serum-Proteome-Based Cancer Diagnosis
Ebert, M. P. A., Korc, M., Malfertheiner, P., & Röcken, C. (2005) · Journal of Proteome Research · doi:10.1021/pr050271e · Cited by 76
Viscidi, R. P., Ahdieh, L., Schneider, M. F., Clayman, B., Massad, L. S., Anastos, K., Burk, R. D., Minkoff, H., Palefsky, J. M., Levine, A., et al. (2003) · The Journal of Infectious Diseases · doi:10.1086/379975 · Cited by 67
Proteomic analysis for early detection of ovarian cancer: A realistic approach?
Stevens, E. V., Liotta, L. A., & Kohn, E. C. (2003) · International Journal of Gynecological Cancer · doi:10.1111/j.1525-1438.2003.13358.x · Cited by 48
Huang, R. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.032 · Cited by 45
Detection of Multiple Cytokines by Protein Arrays from Cell Lysate and Tissue Lysate
Lin, Y., Huang, R., Cao, X. D., Wang, S., Shi, Q., & Huang, R. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.023 · Cited by 43
Molecular targeted therapy of head and neck cancer: Review and clinical development challenges
Tourneau, C. L., Faivre, S. J., & Siu, L. L. (2007) · European Journal of Cancer · doi:10.1016/j.ejca.2007.08.016 · Cited by 43
Denaturation and Renaturation of Self-Assembled Yeast Iso-1-cytochrome c on Au
Chah, S., Kumar, C. V., Hammond, M. R., & Zare, R. N. (2004) · Analytical Chemistry · doi:10.1021/ac035416k · Cited by 41
Self-citationRo, H., Koh, B. H., Jung, S. O., Park, H. K., Shin, Y., Kim, M., & Chung, B. H. (2006) · PROTEOMICS · doi:10.1002/pmic.200500635 · Cited by 39
Postgenomics: Proteomics and Bioinformatics in Cancer Research
Bensmail, H., & Haoudi, A. (2003) · BioMed Research International · doi:10.1155/s1110724303209207 · Cited by 39
Characterization of Multienzyme-Antibody-Carbon Nanotube Bioconjugates for Immunosensors
Jensen, G. C., Yu, X., Gong, J. D., Munge, B. S., Bhirde, A. A., Kim, S. N., Papadimitrakopoulos, F., & Rusling, J. F. (2009) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2009.j016 · Cited by 36
Self-citationMurray, E., McKenna, E. O., Burch, L. R., et al. (2007) · Biochemistry · doi:10.1021/bi7008739 · Cited by 33
Recent advances in capillary electrophoresis‐based proteomic techniques for biomarker discovery
Fang, X., Balgley, B. M., & Lee, C. S. (2009) · Electrophoresis · doi:10.1002/elps.200900219 · Cited by 32
Lonergan, K. M., Chari, R., Coe, B. P., Wilson, I. M., Tsao, M., Ng, R. T., MacAulay, C. E., Lam, S. C., & Lam, W. L. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009162 · Cited by 24
Ravaggi, A., Romani, C., Pasinetti, B., Tassi, R. A., Bignotti, E., Bandiera, E., Odicino, F. E., Ragnoli, M., Donzelli, C., Falchetti, M., et al. (2006) · Archives of Virology · doi:10.1007/s00705-006-0787-y · Cited by 24
Tissue Microarrays as a Tool in the Discovery and Validation of Tumor Markers
Hewitt, S. M. (2009) · Methods in molecular biology · doi:10.1007/978-1-60327-811-9_11 · Cited by 16
Electrochemistry of Peroxidases
Ruzgas, T. A., Lindgren, A., Gorton, L. G. O., Hecht, H., Reichelt, J., & Bilitewski, U. (2002) · doi:10.1201/9780203908907-107 · Cited by 5
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Metadata
- Authors
- Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 135
- Issue
- 10
- Pages
- 2496
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2042242299
- Cited by
- 552
- References
- 104
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.