Sample treatments based on dispersive (micro)extraction
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Sample treatment has evolved in the last few years following basic trends, simplification, automation and miniaturization being the most remarkable ones. Microextraction techniques, including solid phase microextraction (SPME) and liquid phase microextraction (LPME), have emerged in this context showing very competitive features if they are compared with their classic counterparts. Essentially, extraction techniques are surface dependent processes since their kinetics depend directly on the contact surface between the sample and the extractant phase. This aspect, which is important in any extraction procedure, becomes critical when the amount of extractant is reduced to the microscale. In this context, dispersive-based procedures have gained importance as rapid and efficient sample treatment methodologies. This review article deals with the use of dispersion in micro-solid phase extraction (μ-SPE) and LPME. The main techniques as well as their powerful combinations will be described in depth with references to the most relevant applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Leong, M.-I., & Huang, S.-D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.111 · Cited by 413
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Wu, Q., Wang, C., Liu, Z., Wu, C., Zeng, X., Wen, J., & Wang, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.062 · Cited by 174
The roles of ionic liquids in sorptive microextraction techniques
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.009 · Cited by 171
Self-citationRezaee, M., Yamini, Y., Khanchi, A., Faraji, M., & Saleh, A. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.02.006 · Cited by 166
Yamini, Y., Rezaee, M., Khanchi, A., Faraji, M., & Saleh, A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.046 · Cited by 165
One-step in-syringe ionic liquid-based dispersive liquid–liquid microextraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.040 · Cited by 154
Self-citationChang, C.-C., & Huang, S.-D. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.003 · Cited by 152
Leong, M.-I., & Huang, S.-D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.004 · Cited by 151
Separation and Preconcentration by Dispersive Liquid–Liquid Microextraction Procedure: A Review
Bosch Ojeda, C., & Sánchez Rojas, F. (2009) · Chromatographia · doi:10.1365/s10337-009-1104-1 · Cited by 124
Lili, L., Xu, H., Song, D., Cui, Y., Hu, S., & Zhang, G. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.081 · Cited by 123
Huang, K.-J., Wei, C.-Y., Liu, W.-L., Xie, W.-Z., Zhang, J.-F., & Wang, W. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.070 · Cited by 89
Ionic liquid based dispersive liquid–liquid microextraction of aromatic amines in water samples
Fan, Y. C., Hu, Z. L., Chen, M. L., Tu, C. S., & Zhu, Y. (2008) · Chinese Chemical Letters · doi:10.1016/j.cclet.2008.05.024 · Cited by 70
Bai, H., Zhou, Q., Xie, G., & Xiao, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.011 · Cited by 67
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Self-citationA ionic liquid for dispersive liquid-liquid microextraction of phenols
Fan, Y. C., Chen, M. L., Shen-Tu, C., & Zhu, Y. (2009) · Journal of Analytical Chemistry · doi:10.1134/s1061934809100074 · Cited by 43
Research works printed but not linked: 60
- Cudjoe, 2009, J. Pharm. Biomed. Anal., 50, 556, 10.1016/j.jpba.2008.07.014 · doi:10.1016/j.jpba.2008.07.014
- Berladi, 1989, Water Pollut. Res. J. Can., 24, 179, 10.2166/wqrj.1989.010 · doi:10.2166/wqrj.1989.010
- Arthur, 1990, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
- Liu, 1996, Anal. Chem., 68, 1817, 10.1021/ac960145h · DOI · Paper page
- He, 1997, Anal. Chem., 69, 4634, 10.1021/ac970242q · DOI · Paper page
- Baltussen, 1999, J. Microcolumn Sep., 11, 737, 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO;2-4 · DOI · Paper page
- Alcudia-León, 2009, Anal. Chem., 81, 8957, 10.1021/ac9016192 · DOI · Paper page
- Alcudia-León, 2011, J. Chromatogr., A, 1218, 869, 10.1016/j.chroma.2010.12.075 · DOI
- Alcudia-León, 2011, J. Chromatogr., A, 1218, 2176, 10.1016/j.chroma.2011.02.033 · DOI
- Ritcher, 2009, J. Chromatogr., A, 1216, 8598, 10.1016/j.chroma.2009.10.044 · DOI
- Nguyen, 2011, Ultrason. Sonochem., 18, 382, 10.1016/j.ultsonch.2010.07.003 · DOI · Paper page
- Witham, 2005, J. Volcanol. Geotherm. Res., 141, 299, 10.1016/j.jvolgeores.2004.11.010 · DOI · Paper page
- Lehotay, 2007, J. AOAC Int., 90, 485, 10.1093/jaoac/90.2.485 · DOI
- Plössl, 2006, J. Chromatogr., A, 1135, 19, 10.1016/j.chroma.2006.09.033 · DOI · Paper page
- Laganà, 2002, Anal. Chim. Acta, 462, 187, 10.1016/S0003-2670(02)00351-3 · DOI
- Lagarda, 2006, J. Pharm. Biomed. Anal., 41, 1486, 10.1016/j.jpba.2006.02.052 · DOI · Paper page
- Barker, 1989, J. Chromatogr., A, 475, 353, 10.1016/S0021-9673(01)89689-8 · DOI · Paper page
- Tsai, 2008, J. Chromatogr., A, 1216, 2263, 10.1016/j.chroma.2009.01.034 · DOI · Paper page
- Galán-Cano, 2011, Anal. Methods, 3, 991, 10.1039/c1ay05033h · doi:10.1039/c1ay05033h
- Alcudia-León, 2009, Anal. Chem., 81, 1184, 10.1021/ac801507n · DOI
- Garg, 2011, Anal. Bioanal. Chem., 399, 955, 10.1007/s00216-010-4337-9 · doi:10.1007/s00216-010-4337-9
- Valcárcel, 2008, Anal. Bioanal. Chem., 391, 1881, 10.1007/s00216-008-2130-9 · DOI
- Lucena, 2011, J. Chromatogr., A, 1218, 620, 10.1016/j.chroma.2010.10.069 · DOI · Paper page
- Yu, 2010, Anal. Chim. Acta, 678, 50, 10.1016/j.aca.2010.08.012 · DOI
- Zhang, 2010, Anal. Chim. Acta, 665, 167, 10.1016/j.aca.2010.03.026 · doi:10.1016/j.aca.2010.03.026
- Xu, 2011, Anal. Bioanal. Chem., 400, 517, 10.1007/s00216-011-4799-4 · doi:10.1007/s00216-011-4799-4
- López-Lorente, 2011, Anal. Bioanal. Chem., 399, 43, 10.1007/s00216-010-4110-0 · DOI
- Lin, 2010, Anal. Methods, 2, 1874, 10.1039/c0ay00575d · DOI
- Meng, 2011, J. Chromatogr., A, 1218, 1585, 10.1016/j.chroma.2011.01.057 · DOI
- Guan, 2010, Talanta, 83, 337, 10.1016/j.talanta.2010.09.023 · DOI
- Liu, 2009, Talanta, 77, 1037, 10.1016/j.talanta.2008.08.013 · DOI
- Li, 2008, J. Chromatogr., A, 1180, 24, 10.1016/j.chroma.2007.10.067 · DOI
- Zhao, 2008, J. Chromatogr., A, 1188, 140, 10.1016/j.chroma.2008.02.069 · DOI · Paper page
- Faraji, 2010, Talanta, 81, 831, 10.1016/j.talanta.2010.01.023 · DOI
- Ballesteros-Gómez, 2009, Anal. Chem., 81, 9012, 10.1021/ac9016264 · DOI
- Abismaïl, 1999, Ultrason. Sonochem., 6, 75, 10.1016/S1350-4177(98)00027-3 · DOI · Paper page
- Tsai, 2009, J. Chromatogr., A, 1216, 5171, 10.1016/j.chroma.2009.04.086 · DOI
- Xie, 2010, Microchim. Acta, 168, 253, 10.1007/s00604-010-0291-7 · DOI
- Hashemi, 2009, Anal. Chim. Acta, 655, 60, 10.1016/j.aca.2009.09.034 · DOI · Paper page
- Farajzadeh, 2009, J. Sep. Sci., 32, 3191, 10.1002/jssc.200900109 · DOI · Paper page
- Farajzadeh, 2010, Talanta, 81, 1360, 10.1016/j.talanta.2010.02.035 · DOI
- Chou, 2009, Talanta, 80, 493, 10.1016/j.talanta.2009.07.005 · DOI
- Melwanki, 2008, J. Chromatogr., A, 1207, 24, 10.1016/j.chroma.2008.08.052 · DOI
- Chen, 2010, Talanta, 81, 176, 10.1016/j.talanta.2009.11.054 · DOI
- Li, 2009, Spectrochim. Acta, Part B, 64, 666, 10.1016/j.sab.2009.05.023 · DOI · Paper page
- Wu, 2010, J. Chromatogr., A, 1217, 1773, 10.1016/j.chroma.2010.01.060 · DOI · Paper page
- Saleh, 2009, J. Chromatogr., A, 1216, 6673, 10.1016/j.chroma.2009.08.001 · DOI · Paper page
- Xu, 2009, Anal. Chim. Acta, 636, 28, 10.1016/j.aca.2009.01.028 · DOI · Paper page
- Chen, 2010, J. Chromatogr., A, 1217, 1244, 10.1016/j.chroma.2009.12.062 · DOI · Paper page
- Palacio, 2008, Adv. Mater., 20, 1194, 10.1002/adma.200702006 · DOI
- Anderson, 2006, Anal. Chem., 78, 2892, 10.1021/ac069394o · DOI · Paper page
- Gharehbaghi, 2009, Int. J. Environ. Anal. Chem., 89, 21, 10.1080/03067310802272994 · DOI · Paper page
- Pena, 2009, J. Chromatogr., A, 1216, 6356, 10.1016/j.chroma.2009.07.032 · DOI · Paper page
- He, 2009, Anal. Chim. Acta, 655, 52, 10.1016/j.aca.2009.09.044 · DOI · Paper page
- Bertona, 2009, Anal. Chim. Acta, 640, 40, 10.1016/j.aca.2009.03.028 · DOI
- Baghdadi, 2009, Anal. Chim. Acta, 634, 186, 10.1016/j.aca.2008.12.017 · DOI · Paper page
- Shi, 2010, Anal. Chem., 82, 1540, 10.1021/ac9023632 · DOI · Paper page
- O'Reilly, 2005, J. Sep. Sci., 28, 2010, 10.1002/jssc.200500244 · DOI
- Hutchinson, 2007, J. Chromatogr., A, 1149, 127, 10.1016/j.chroma.2007.02.117 · DOI · Paper page
- Vuckovic, 2008, Anal. Chem., 80, 6870, 10.1021/ac800936r · DOI
Cited by
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Recent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0101 · Cited by 50
“Since the invention of DLLME in 2006, the number of studies concerning its application in the determination of PAHs has been continually growing [68, 108-112].”
BackgroundRivera-Vera, C., Lasarte-Aragonés, G., Bravo, M. A., Muñoz-Lira, D., Salazar, R., & Toledo-Neira, C. (2019) · Food Control · doi:10.1016/j.foodcont.2019.06.011 · Cited by 43
Metadata
- Authors
- Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M.
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 3
- Issue
- 8
- Pages
- 1719
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W1979365826
- Cited by
- 82
- References
- 22
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.