The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
1-Million droplet array with wide-field fluorescence imaging for digital PCR
Abstract
Digital droplet reactors are useful as chemical and biological containers to discretize reagents into picolitre or nanolitre volumes for analysis of single cells, organisms, or molecules. However, most DNA based assays require processing of samples on the order of tens of microlitres and contain as few as one to as many as millions of fragments to be detected. Presented in this work is a droplet microfluidic platform and fluorescence imaging setup designed to better meet the needs of the high-throughput and high-dynamic-range by integrating multiple high-throughput droplet processing schemes on the chip. The design is capable of generating over 1-million, monodisperse, 50 picolitre droplets in 2-7 minutes that then self-assemble into high density 3-dimensional sphere packing configurations in a large viewing chamber for visualization and analysis. This device then undergoes on-chip polymerase chain reaction (PCR) amplification and fluorescence detection to digitally quantify the sample's nucleic acid contents. Wide-field fluorescence images are captured using a low cost 21-megapixel digital camera and macro-lens with an 8-12 cm(2) field-of-view at 1× to 0.85× magnification, respectively. We demonstrate both end-point and real-time imaging ability to perform on-chip quantitative digital PCR analysis of the entire droplet array. Compared to previous work, this highly integrated design yields a 100-fold increase in the number of on-chip digitized reactors with simultaneous fluorescence imaging for digital PCR based assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
A survey of thresholding techniques
Sahoo, P. K., Soltani, S., & Wong, A. K. C. (1988) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(88)90022-9 · Cited by 2,662
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
Current Protocols in Cytometry
(2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471142956 · Cited by 862
El Gamal, A., & Eltoukhy, H. (2005) · IEEE Circuits and Devices Magazine · doi:10.1109/mcd.2005.1438751 · Cited by 801
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Clausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Quantitation of targets for PCR by use of limiting dilution.
Sykes, P. J., Neoh, S. H., Brisco, M. J., Hughes, E., Condon, J. C., & Morley, A. A. (1992) · PubMed · Cited by 618
Beverung, C. J., Radke, C. J., & Blanch, H. W. (1999) · Biophysical Chemistry · doi:10.1016/s0301-4622(99)00082-4 · Cited by 608
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
BEAMing: single-molecule PCR on microparticles in water-in-oil emulsions
Diehl, F., Li, M., He, Y., Kinzler, K. W., Vogelstein, B., & Dressman, D. (2006) · Nature Methods · doi:10.1038/nmeth898 · Cited by 496
Amplification of complex gene libraries by emulsion PCR
Williams, R., Peisajovich, S. G., Miller, O. J., Magdassi, S., Tawfik, D. S., & Griffiths, A. D. (2006) · Nature Methods · doi:10.1038/nmeth896 · Cited by 358
On-Chip, Real-Time, Single-Copy Polymerase Chain Reaction in Picoliter Droplets
Beer, N. R., Hindson, B. J., Wheeler, E. K., Hall, S. B., Rose, K. A., Kennedy, I. M., & Colston, B. W. (2007) · Analytical Chemistry · doi:10.1021/ac701809w · Cited by 358
Miniaturising the laboratory in emulsion droplets
Griffiths, A. D., & Tawfik, D. S. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.009 · Cited by 346
High-Throughput Quantitative Polymerase Chain Reaction in Picoliter Droplets
Kiss, M. M., Ortoleva-Donnelly, L., Beer, N. R., Warner, J., Bailey, C. G., Colston, B. W., Rothberg, J. M., Link, D. R., & Leamon, J. H. (2008) · Analytical Chemistry · doi:10.1021/ac801276c · Cited by 326
Patterning Mammalian Cells Using Elastomeric Membranes
Ostuni, E., Kane, R., Chen, C. S., Ingber, D. E., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000382m · Cited by 316
Multiplex digital PCR: breaking the one target per color barrier of quantitative PCR
Zhong, Q., Bhattacharya, S., Kotsopoulos, S., Olson, J., Taly, V., Griffiths, A. D., Link, D. R., & Larson, J. W. (2011) · Lab on a Chip · doi:10.1039/c1lc20126c · Cited by 297
Shen, F., Du, W., Kreutz, J. E., Fok, A., & Ismagilov, R. F. (2010) · Lab on a Chip · doi:10.1039/c004521g · Cited by 295
Roach, L. S., Song, H., & Ismagilov, R. F. (2005) · Analytical Chemistry · doi:10.1021/ac049061w · Cited by 277
Continuous-Flow Polymerase Chain Reaction of Single-Copy DNA in Microfluidic Microdroplets
Schaerli, Y., Wootton, R. C., Robinson, T., Stein, V., Dunsby, C., Neil, M. A. A., French, P. M. W., deMello, A. J., Abell, C., & Hollfelder, F. (2009) · Analytical Chemistry · doi:10.1021/ac802038c · Cited by 263
Multiplexed Real-Time Polymerase Chain Reaction on a Digital Microfluidic Platform
Hua, Z., Rouse, J. L., Eckhardt, A. E., Srinivasan, V., Pamula, V. K., Schell, W. A., Benton, J. L., Mitchell, T. G., & Pollack, M. G. (2010) · Analytical Chemistry · doi:10.1021/ac902510u · Cited by 248
High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator Arrays
Zeng, Y., Novak, R., Shuga, J., Smith, M. T., & Mathies, R. A. (2010) · Analytical Chemistry · doi:10.1021/ac902683t · Cited by 232
Weaver, S., Dube, S., Mir, A., Qin, J., Sun, G., Ramakrishnan, R., Jones, R. C., & Livak, K. J. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.003 · Cited by 220
Controlling the Retention of Small Molecules in Emulsion Microdroplets for Use in Cell-Based Assays
Courtois, F., Olguin, L. F., Whyte, G., Theberge, A. B., Huck, W. T. S., Hollfelder, F., & Abell, C. (2009) · Analytical Chemistry · doi:10.1021/ac802658n · Cited by 212
On-Chip Single-Copy Real-Time Reverse-Transcription PCR in Isolated Picoliter Droplets
Beer, N. R., Wheeler, E. K., Lee-Houghton, L., Watkins, N., Nasarabadi, S., Hebert, N., Leung, P., Arnold, D. W., Bailey, C. G., & Colston, B. W. (2008) · Analytical Chemistry · doi:10.1021/ac800048k · Cited by 209
Digital PCR provides sensitive and absolute calibration for high throughput sequencing
White, R. A., Blainey, P. C., Fan, H. C., & Quake, S. R. (2009) · BMC Genomics · doi:10.1186/1471-2164-10-116 · Cited by 195
Courtois, F., Olguin, L. F., Whyte, G., Bratton, D., Huck, W. T. S., Abell, C., & Hollfelder, F. (2008) · ChemBioChem · doi:10.1002/cbic.200700536 · Cited by 183
Bubner, B., Gase, K., & Baldwin, I. T. (2004) · BMC Biotechnology · doi:10.1186/1472-6750-4-14 · Cited by 162
Droplets as Microreactors for High‐Throughput Biology
Taly, V., Kelly, B. T., & Griffiths, A. D. (2007) · ChemBioChem · doi:10.1002/cbic.200600425 · Cited by 153
The potential of microfluidic water-in-oil droplets in experimental biology
Schaerli, Y., & Hollfelder, F. (2009) · Molecular BioSystems · doi:10.1039/b907578j · Cited by 150
Spinning Disk Platform for Microfluidic Digital Polymerase Chain Reaction
Sundberg, S. O., Wittwer, C. T., Gao, C., & Gale, B. K. (2010) · Analytical Chemistry · doi:10.1021/ac902398c · Cited by 146
PCR Troubleshooting and Optimization: The Essential Guide
Kennedy, S., & Oswald, N. (2011) · Cited by 123
A Mechanistic Model of PCR for Accurate Quantification of Quantitative PCR Data
Boggy, G. J., & WOOLF, P. J. (2010) · PLoS ONE · doi:10.1371/journal.pone.0012355 · Cited by 101
Novel real-time quantitative PCR test for trisomy 21
Zimmermann, B., Holzgreve, W., Wenzel, F., & Hahn, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.2.362 · Cited by 86
Nanodroplet real-time PCR system with laser assisted heating
Kim, H., Dixit, S. S., Green, C. J., & Faris, G. W. (2008) · Optics Express · doi:10.1364/oe.17.000218 · Cited by 74
Tunable 3D droplet self-assembly for ultra-high-density digital micro-reactor arrays
Hatch, A. C., Fisher, J. S., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011) · Lab on a Chip · doi:10.1039/c0lc00553c · Cited by 66
Self-citationTransformation of real-time PCR fluorescence data to target gene quantity
Číkoš, Š., & Koppel, J. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.08.031 · Cited by 66
Single-molecule reverse transcription polymerase chain reaction using water-in-oil emulsion
Nakano, M., Nakai, N., Kurita, H., Komatsu, J., Takashima, K., Katsura, S., & Mizuno, A. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.99.293 · Cited by 46
Uniform amplification of multiple DNAs by emulsion PCR
Hori, M., Fukano, H., & Suzuki, Y. (2006) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2006.11.037 · Cited by 44
1,2-propanediol-trehalose mixture as a potent quantitative real-time PCR enhancer
Horáková, H., Polakovičová, I., Shaik, G. M., et al. (2011) · BMC Biotechnology · doi:10.1186/1472-6750-11-41 · Cited by 44
Quantitative Detection of Bioassays with a Low‐Cost Image‐Sensor Array for Integrated Microsystems
Vykoukal, D. M., Stone, G. P., Gascoyne, P. R. C., Alt, E., & Vykoukal, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901814 · Cited by 28
Calibration Curves for Real-Time PCR
Lai, K.-C., Cook, L., Krantz, E. M., Corey, L., & Jerome, K. R. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.039909 · Cited by 23
Baret, J., Taly, V., Ryckelynck, M., Merten, C. A., & Griffiths, A. D. (2009) · médecine/sciences · doi:10.1051/medsci/2009256-7627 · Cited by 22
Research works printed but not linked: 7
- Gan, 2008, Biotechnol. Prog., 24, 1107, 10.1002/btpr.43 · doi:10.1002/btpr.43
- Sykes, 1992, BioTechniques, 13, 444
- Poussier, 2002, J. Microbiol. Methods, 51, 349, 10.1016/S0167-7012(02)00111-2 · doi:10.1016/s0167-7012(02)00111-2
- Morrison, 1998, BioTechniques, 24, 954
- Shen, 2011, Sens. Actuators, B, 155, 430, 10.1016/j.snb.2011.01.001 · doi:10.1016/j.snb.2011.01.001
- Song, 2005, Biosens. Bioelectron., 20, 2203, 10.1016/j.bios.2004.08.033 · doi:10.1016/j.bios.2004.08.033
- Chapin, 1997, J. Clin. Microbiol., 35, 2157, 10.1128/JCM.35.8.2157-2159.1997 · doi:10.1128/jcm.35.8.2157-2159.1997
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Metadata
- Authors
- Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 22
- Pages
- 3838
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1988955440
- Cited by
- 317
- References
- 49
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.