The DOI matches its Crossref record; 132 of the 132 references it cites were found in a registry or an index.
Electrical biosensors and the label free detection of protein disease biomarkers
Abstract
Electrical detection methodologies are likely to underpin the progressive drive towards miniaturised, sensitive and portable biomarker detection protocols. In being easily integrated within standard electronic microfabrication formats, and developing capability in microfluidics, the facile multiplexed detection of a range of proteins in a small analytical volume becomes entirely feasible with something costing just a few thousand pounds and benchtop or handheld in scale. In this review, we focus on recent important advances in label free assays of protein using a number of electrical methods, including those based on electrochemical impedance spectroscopy (EIS), amperometry/voltammetry, potentiometry, conductometry and field-effect methods. We introduce their mechanistic features and examples of application and sensitivity. The current state of the art, real world applications and challenges are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Phases of Biomarker Development for Early Detection of Cancer
Pepe, M. S., Etzioni, R., Feng, Z., Potter, J. D., Thompson, M. L., Thornquist, M., Winget, M., & Yasui, Y. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.14.1054 · Cited by 1,686
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Analytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
Reflections on the history of electrochemical impedance spectroscopy
Macdonald, D. D. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.107 · Cited by 1,001
Sawyers, C. L. (2008) · Nature · doi:10.1038/nature06913 · Cited by 983
Controlled Growth and Structures of Molecular-Scale Silicon Nanowires
Wu, Y., Cui, Y., Huynh, L., Barrelet, C. J., Bell, D. C., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl035162i · Cited by 963
Electrolyte-Gated Graphene Field-Effect Transistors for Detecting pH and Protein Adsorption
Ohno, Y., Maehashi, K., Yamashiro, Y., & Matsumoto, K. (2009) · Nano Letters · doi:10.1021/nl901596m · Cited by 833
Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Cosnier, S. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00024-x · Cited by 768
Aptamer in Bioanalytical Applications
Iliuk, A. B., Hu, L., & Tao, W. A. (2011) · Analytical Chemistry · doi:10.1021/ac201057w · Cited by 762
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Biology of Prostate-Specific Antigen
Balk, S. P., Ko, Y.-J., & Bubley, G. J. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.02.083 · Cited by 718
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
The rational development of molecularly imprinted polymer-based sensors for protein detection
Whitcombe, M. J., Chianella, I., Larcombe, L., Piletsky, S. A., Noble, J., Porter, R., & Horgan, A. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00049c · Cited by 711
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Blood compatibility of polyethylene oxide surfaces
LEE, J., LEE, H., & ANDRADE, J. (1995) · Progress in Polymer Science · doi:10.1016/0079-6700(95)00011-4 · Cited by 703
Engineering novel binding proteins from nonimmunoglobulin domains
Binz, H. K., Amstutz, P., & Plückthun, A. (2005) · Nature Biotechnology · doi:10.1038/nbt1127 · Cited by 676
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Analytical Chemistry · doi:10.1021/ac060830g · Cited by 660
Three-dimensional structures of avidin and the avidin-biotin complex.
Livnah, O., Bayer, E. A., Wilchek, M., & Sussman, J. L. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5076 · Cited by 652
Chen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645
Single-Walled Carbon Nanotube Biosensors Using Aptamers as Molecular Recognition Elements
So, H.-M., Won, K., Kim, Y. H., Kim, B.-K., Ryu, B. H., Na, P. S., Kim, H., & Lee, J.-O. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053094r · Cited by 579
Keefe, A. J., & Jiang, S. (2012) · Nature Chemistry · doi:10.1038/nchem.1213 · Cited by 576
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Label-Free Biosensors Based on Aptamer-Modified Graphene Field-Effect Transistors
Ohno, Y., Maehashi, K., & Matsumoto, K. (2010) · Journal of the American Chemical Society · doi:10.1021/ja108127r · Cited by 554
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Zwitterionic carboxybetaine polymer surfaces and their resistance to long-term biofilm formation
Cheng, G., Li, G., Xue, H., Chen, S., Bryers, J. D., & Jiang, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.058 · Cited by 523
Selective Covalent Protein Immobilization: Strategies and Applications
Wong, L. S., Khan, F., & Micklefield, J. (2009) · Chemical Reviews · doi:10.1021/cr8004668 · Cited by 489
Genetic selection of peptide aptamers that recognize and inhibit cyclin-dependent kinase 2
Colas, P., Cohen, B., Jessen, T., Grishina, I., McCoy, J., & Brent, R. (1996) · Nature · doi:10.1038/380548a0 · Cited by 459
Considerations in the Evaluation of Surrogate Endpoints in Clinical Trials
De Gruttola, V. G., Clax, P., DeMets, D. L., Downing, G. J., Ellenberg, S. S., Friedman, L., Gail, M. H., Prentice, R., Wittes, J., & Zeger, S. L. (2001) · Controlled Clinical Trials · doi:10.1016/s0197-2456(01)00153-2 · Cited by 427
Nucleic Acid AptamersFrom Selection in Vitro to Applications in Vivo
Famulok, M., Mayer, G., & Blind, M. (2000) · Accounts of Chemical Research · doi:10.1021/ar960167q · Cited by 422
Immobilization of bio-macromolecules on self-assembled monolayers: methods and sensor applications
Samanta, D., & Sarkar, A. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00056f · Cited by 417
Luo, X.-L., Xu, J.-J., Du, Y., & Chen, H.-Y. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.07.005 · Cited by 397
Self-citationComplementary Detection of Prostate-Specific Antigen Using In2O3 Nanowires and Carbon Nanotubes
Li, C., Curreli, M., Lin, H., Lei, B., Ishikawa, F. N., Datar, R., Cote, R. J., Thompson, M. E., & Zhou, C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053761g · Cited by 378
Increased Matrix Metalloproteinase-9 Predicts Poor Wound Healing in Diabetic Foot Ulcers
Liu, Y., Min, D., Bolton, T., Nubé, V., Twigg, S. M., Yue, D. K., & McLennan, S. V. (2009) · Diabetes Care · doi:10.2337/dc08-0763 · Cited by 374
Gupta, R., & Chaudhury, N. K. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.12.025 · Cited by 349
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Okuno, J., Maehashi, K., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.09.038 · Cited by 309
Label-Free Electrochemical Detection for Aptamer-Based Array Electrodes
Xu, D., Xu, D., Yu, X., Liu, Z., He, W., & Ma, Z. (2005) · Analytical Chemistry · doi:10.1021/ac050192m · Cited by 304
Graphene‐Encapsulated Nanoparticle‐Based Biosensor for the Selective Detection of Cancer Biomarkers
Myung, S., Solanki, A., Kim, C., Park, J., Kim, K. S., & Lee, K. (2011) · Advanced Materials · doi:10.1002/adma.201100014 · Cited by 288
Electrochemical Sensors Based on Molecularly Imprinted Polymers
Piletsky, S. A., & Turner, A. P. F. (2002) · Electroanalysis · doi:10.1002/1521-4109(200203)14:5<317::aid-elan317>3.0.co;2-5 · Cited by 282
Kozak, K. R., Amneus, M. W., Pusey, S. M., Su, F., Luong, M. N., Luong, S. A., Reddy, S. T., & Farias-Eisner, R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2033602100 · Cited by 276
New Trends in Impedimetric Biosensors for the Detection of Foodborne Pathogenic Bacteria
Wang, Y., Ye, Z., & Ying, Y. (2012) · Sensors · doi:10.3390/s120303449 · Cited by 268
Chua, J. H., Chee, R.-E., Agarwal, A., Wong, S. M., & Zhang, G.-J. (2009) · Analytical Chemistry · doi:10.1021/ac901157x · Cited by 266
Electrochemical Sensor for Multiplex Biomarkers Detection
Wei, F., Patel, P., Liao, W., Chaudhry, K., Zhang, L., Arellano-Garcia, M., Hu, S., Elashoff, D., Zhou, H., Shukla, S., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-0050 · Cited by 257
Ion Selective Electrodes (ISEs) and interferences—A review
Dimeski, G., Badrick, T., & John, A. S. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.12.005 · Cited by 253
Leenaars, M., & Hendriksen, C. F. M. (2005) · ILAR Journal · doi:10.1093/ilar.46.3.269 · Cited by 253
Electrochemical Impedance Immunosensor Based on Three-Dimensionally Ordered Macroporous Gold Film
Chen, X., Wang, Y., Zhou, J., Yan, W., Li, X., & Zhu, J.-J. (2008) · Analytical Chemistry · doi:10.1021/ac7021376 · Cited by 250
Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors
Kim, A., Ah, C. S., Yu, H. Y., Yang, J.-H., Baek, I.-B., Ahn, C.-G., Park, C. W., Jun, M. S., & Lee, S. (2007) · Applied Physics Letters · doi:10.1063/1.2779965 · Cited by 250
Electrochemical Sensors Based on Molecularly Imprinted Polymers
Piletsky, S. A., & Turner, A. P. F. (2002) · Electroanalysis · Cited by 245
Carbon nanomaterials field-effect-transistor-based biosensors
Liu, S., & Guo, X. (2012) · NPG Asia Materials · doi:10.1038/am.2012.42 · Cited by 243
Erickson, D., Mandal, S., Yang, A. H. J., & Cordovez, B. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0198-8 · Cited by 242
Electrochemically deposited nanocomposite of chitosan and carbon nanotubes for biosensor application
Luo, X.-L., Xu, J.-J., Wang, J.-L., & Chen, H.-Y. (2005) · Chemical Communications · doi:10.1039/b419197h · Cited by 235
Self-citationBiorecognition Layer Engineering: Overcoming Screening Limitations of Nanowire-Based FET Devices
Elnathan, R., Kwiat, M., Pevzner, A., Engel, Y., Burstein, L., Khatchtourints, A., Lichtenstein, A., Kantaev, R., & Patolsky, F. (2012) · Nano Letters · doi:10.1021/nl302434w · Cited by 231
Ishikawa, F. N., Chang, H.-K., Curreli, M., Liao, H.-I., Olson, C. A., Chen, P.-C., Zhang, R., Roberts, R. W., Sun, R., Cote, R. J., et al. (2009) · ACS Nano · doi:10.1021/nn900086c · Cited by 223
Self-assembly of poly(ethylene glycol)-based block copolymers for biomedical applications
Otsuka, H., Nagasaki, Y., & Kataoka, K. (2001) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(00)00082-0 · Cited by 222
An optimised electrochemical biosensor for the label-free detection of C-reactive protein in blood
Bryan, T., Luo, X., Bueno, P. R., & Davis, J. J. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.051 · Cited by 215
Self-citationMolecular and cellular aspects of protein misfolding and disease
Herczenik, E., & Gebbink, M. F. B. G. (2008) · The FASEB Journal · doi:10.1096/fj.07-099671 · Cited by 205
Silicon Nanoribbons for Electrical Detection of Biomolecules
Elfström, N., Karlström, A. E., & Linnros, J. (2008) · Nano Letters · doi:10.1021/nl080094r · Cited by 185
Single Conducting Polymer Nanowire Chemiresistive Label-Free Immunosensor for Cancer Biomarker
Bangar, M. A., Shirale, D. J., Chen, W., Myung, N. V., & Mulchandani, A. (2009) · Analytical Chemistry · doi:10.1021/ac802319f · Cited by 184
Wang, Y., Zhang, Z., Jain, V., Yi, J., Mueller, S., Sokolov, J., Liu, Z., Levon, K., Rigas, B., & Rafailovich, M. H. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.02.032 · Cited by 180
Label-free protein recognition using an aptamer-based impedance measurement assay
Cai, H., Lee, T. M.-H., & Hsing, I.-M. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.06.017 · Cited by 175
Cantilever Sensors: Nanomechanical Tools for Diagnostics
Datar, R., Kim, S., Jeon, S., Hesketh, P., Manalis, S., Boisen, A., & Thundat, T. (2009) · MRS Bulletin · doi:10.1557/mrs2009.121 · Cited by 163
Nanowire sensors for multiplexed detection of biomolecules
He, B., Morrow, T. J., & Keating, C. D. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.08.027 · Cited by 159
mRNA display: ligand discovery, interaction analysis and beyond
Takahashi, T. T., Austin, R. J., & Roberts, R. W. (2003) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(03)00036-7 · Cited by 158
Affinity Biosensors Based on Electropolymerized Films
Cosnier, S. (2005) · Electroanalysis · doi:10.1002/elan.200503308 · Cited by 157
Engineered proteins as specific binding reagents
Binz, H. K., & Plückthun, A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2005.06.005 · Cited by 157
The light-addressable potentiometric sensor for multi-ion sensing and imaging
Yoshinobu, T., Iwasaki, H., Ui, Y., Furuichi, K., Ermolenko, Y. Е., Mourzina, Y. G., Wagner, T., Näther, N., & Schöning, M. J. (2005) · Methods · doi:10.1016/j.ymeth.2005.05.020 · Cited by 153
Chikkaveeraiah, B. V., Bhirde, A. A., Malhotra, R., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · Analytical Chemistry · doi:10.1021/ac9018022 · Cited by 151
Zwitterionic poly(carboxybetaine) hydrogels for glucose biosensors in complex media
Yang, W. M., Xue, H., Carr, L. R., Wang, J., & Jiang, S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.031 · Cited by 149
The label free picomolar detection of insulin in blood serum
Xu, M., Luo, X., & Davis, J. J. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.014 · Cited by 144
Self-citationA potentiometric protein sensor built with surface molecular imprinting method
Wang, Y., Zhou, Y., Sokolov, J., Rigas, B., Levón, K., & Rafailovich, M. H. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.04.010 · Cited by 129
Lerner, M. B., D’Souza, J. W., Pazina, T., Dailey, J., Goldsmith, B. R., Robinson, M. K., & Johnson, A. T. C. (2012) · ACS Nano · doi:10.1021/nn300819s · Cited by 128
ELISA microarray technology as a high-throughput system for cancer biomarker validation
Zangar, R. C., Daly, D. S., & White, A. M. (2006) · Expert Review of Proteomics · doi:10.1586/14789450.3.1.37 · Cited by 120
Krivitsky, V., Hsiung, L.-C., Lichtenstein, A., Brudnik, B., Kantaev, R., Elnathan, R., Pevzner, A., Khatchtourints, A., & Patolsky, F. (2012) · Nano Letters · doi:10.1021/nl3021889 · Cited by 116
A highly sensitive aptasensor towards Plasmodium lactate dehydrogenase for the diagnosis of malaria
Lee, S., Song, K.-M., Jeon, W., Jo, H., Shim, Y., & Ban, C. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.003 · Cited by 113
Ciani, I., Schulze, H., Corrigan, D. K., et al. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.004 · Cited by 110
Gold nanoparticles mediated label-free capacitance detection of cardiac troponin I
Bhalla, V., Carrara, S., Sharma, P., Nangia, Y., & Suri, C. R. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.029 · Cited by 108
Insulin Oxidation and Determination at Carbon Electrodes
Zhang, M., Mullens, C. P., & Górski, W. (2005) · Analytical Chemistry · doi:10.1021/ac0508752 · Cited by 107
Ultrasensitive Label Free Electrical Detection of Insulin in Neat Blood Serum
Luo, X., Xu, M., Freeman, C., James, T. J., & Davis, J. J. (2013) · Analytical Chemistry · doi:10.1021/ac4002657 · Cited by 107
Self-citationImpedimetric immunosensor using avidin–biotin for antibody immobilization
Ouerghi, O., Touhami, A., Jaffrezic-Renault, N. J., Martelet, C., Ouada, H. B., & Cosnier, S. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(02)00029-4 · Cited by 104
Multifunctional protein labeling via enzymatic N-terminal tagging and elaboration by click chemistry
Heal, W. P., Wright, M. H., Thinon, E., & Tate, E. W. (2011) · Nature Protocols · doi:10.1038/nprot.2011.425 · Cited by 104
Immobilization of histidine-tagged proteins on electrodes
Ley, C., Holtmann, D., Mangold, K., & Schrader, J. (2011) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2011.07.044 · Cited by 89
Elshafey, R., Tlili, C., Abulrob, A., Tavares, A. C., & Zourob, M. M. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.049 · Cited by 89
The robust electrochemical detection of a Parkinson's disease marker in whole blood sera
Bryan, T., Luo, X., Forsgren, L., Morozova‐Roche, L. A., & Davis, J. J. (2012) · Chemical Science · doi:10.1039/c2sc21221h · Cited by 87
Self-citationRapid, Label-Free, Electrical Whole Blood Bioassay Based on Nanobiosensor Systems
Chang, H.-K., Ishikawa, F. N., Zhang, R., Datar, R. H., Côté, R. J., Thompson, M. E., & Zhou, C. (2011) · ACS Nano · doi:10.1021/nn2035796 · Cited by 87
Kim, A., Ah, C. S., Park, C. W., Yang, J., Kim, T., Ahn, C.-G., Park, S. H., & Sung, G. Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.026 · Cited by 84
Moreira, F. T. C., Dutra, R. F., Noronha, J. P., Cunha, A. L., & Sales, M. G. F. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.026 · Cited by 83
Jia, Y., Qin, M., Zhang, H., et al. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.01.018 · Cited by 82
Takahashi, M., Figus, C., Malfatti, L., et al. (2012) · NPG Asia Materials · doi:10.1038/am.2012.40 · Cited by 79
Sensitive Affimer and Antibody Based Impedimetric Label-Free Assays for C-Reactive Protein
Johnson, A., Song, Q., Ferrigno, P. K., Bueno, P. R., & Davis, J. J. (2012) · Analytical Chemistry · doi:10.1021/ac300835b · Cited by 75
Self-citationReagentless aptamer based impedance biosensor for monitoring a neuro-inflammatory cytokine PDGF
Liao, W., & Cui, X. T. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.04.004 · Cited by 75
Juretzka, M. M., Barakat, R. R., Dennis, S., Iasonos, A. E., Dupont, J., Abu‐Rustum, N. R., Poynor, E. A., Aghajanian, C. A., Spriggs, D. R., Hensley, M. L., et al. (2006) · Gynecologic Oncology · doi:10.1016/j.ygyno.2006.07.027 · Cited by 74
Qu, L., Xia, S., Bian, C., Sun, J., & Han, J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.077 · Cited by 72
Lin, J., Wei, Z., Zhang, H., & Shao, M. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.051 · Cited by 68
de Vasconcelos, E. A., Peres, N. G., Pereira, C. O., da Silva, V. L., da Silva, E. F., & Dutra, R. F. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.050 · Cited by 65
Rapid Development of New Protein Biosensors Utilizing Peptides Obtained via Phage Display
Wu, J., Park, J. P., Dooley, K., Cropek, D. M., West, A. C., & Banta, S. A. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024948 · Cited by 60
Soluble triggering receptor expressed on myeloid cells 1 and the diagnosis of sepsis
Barati, M., Rahimi‐Bashar, F., Shahrami, R., et al. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2009.10.004 · Cited by 59
Multiplexed detection of cardiac biomarkers in serum with nanowire arrays using readout ASIC
Zhang, G., Chai, K. T. C., Luo, H., Huang, J. M., Tay, I., Lim, A. E.-J., & Je, M. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.02.052 · Cited by 57
Sezgintürk, M. K. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.03.025 · Cited by 55
Single-walled carbon nanotube chemoresistive label-free immunosensor for salivary stress biomarkers
Tlili, C., Cella, L. N., Myung, N. V., Shetty, V., & Mulchandani, A. (2010) · The Analyst · doi:10.1039/c0an00332h · Cited by 54
Analytical aspects of fet-based biosensors
Xu, J. (2005) · Frontiers in bioscience · doi:10.2741/1538 · Cited by 52
Electrical impedimetric biosensors for liver function detection
Chuang, Y.-H., Chang, Y.-T., Liu, K.-L., Chang, H., & Yew, T. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.049 · Cited by 52
Liao, H.-I., Olson, C. A., Hwang, S., Deng, H., Wong, E., Baric, R. S., Roberts, R. W., & Sun, R. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m901547200 · Cited by 51
Ultrasensitive protein detection using an aptamer-functionalized single polyaniline nanowire
Luo, X., Lee, I., Huang, J., Yun, M., & Cui, X. T. (2011) · Chemical Communications · doi:10.1039/c1cc11353d · Cited by 50
Self-citationStadler, L. K. J., Hoffmann, T., Tomlinson, D. C., Song, Q., Lee, T., Busby, M., Nyathi, Y., Gendra, E., Tiede, C., Flanagan, K., et al. (2011) · Protein Engineering Design and Selection · doi:10.1093/protein/gzr019 · Cited by 49
Self-citationLarge libraries reveal diverse solutions to an RNA recognition problem
Barrick, J. E., Takahashi, T. T., Ren, J., Xia, T., & Roberts, R. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.221467798 · Cited by 48
Modifying Randles Circuit for Analysis of Polyoxometalate Layer-by-Layer Films
Vyas, R. N., Li, K., & Wang, B. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp105075t · Cited by 43
Park, J.-W., Kallempudi, S. S., Niazi, J. H., Gürbüz, Y., Youn, B., & Gu, M. B. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.05.036 · Cited by 39
Vallina-García, R., Garcı́a-Suárez, M. D. M., Fernández-Abedul, M. T., Méndez, F. J., & Costa‐García, A. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.04.001 · Cited by 35
Yang, Y., Guo, L., Qu, N., Wei, M., Zhao, L., & Wan, B. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.033 · Cited by 34
Cancer Biomarker Detection by Surface Plasmon Resonance Biosensors
Reddy, P. J., Sadhu, S., Ray, S., & Srivastava, S. (2011) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2011.11.002 · Cited by 33
Hoffmann, T., Stadler, L. K. J., Busby, M., Song, Q., Buxton, A. T., Wagner, S. D., Davis, J. J., & Ferrigno, P. K. (2010) · Protein Engineering Design and Selection · doi:10.1093/protein/gzq012 · Cited by 33
Self-citationJia, Y., Gao, C., He, J., Feng, D., Xing, K., Wu, M. J., Liu, Y., Cai, W., & Feng, X. (2012) · The Analyst · doi:10.1039/c2an35188a · Cited by 30
Yeo, J., Park, J., Bae, W. J., Lee, L. Y. S., Kim, B. H., Cho, Y., & Park, S. (2009) · Analytical Chemistry · doi:10.1021/ac900301h · Cited by 26
Chen, C.-S., Chang, K.-N., Chen, Y., Lee, C., Lee, B. Y.-J., & Lee, A. S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.11.051 · Cited by 25
May, K. M. L., Vogt, A. P., Bachas, L. G., & Anderson, K. W. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3224-2 · Cited by 24
Cancer Prognostics by Direct Detection of p53‐Antibodies on Gold Surfaces by Impedance Measurements
Prats‐Alfonso, E., Sisquella, X., Zine, N., Gabriel, G., Guimerà‐Brunet, A., del Campo, F. J., Villa, R., Eisenberg, A. H., Mrksich, M., Errachid, A., et al. (2012) · Small · doi:10.1002/smll.201102724 · Cited by 23
Zur Anwendung der Transformations-Impedanzspektrometrie
Lorenz, W. E., & SCHULZE, K. (1975) · Journal of Electroanalytical Chemistry (1959) · doi:10.1016/0368-1874(75)85112-4 · Cited by 23
Peptide Aptamer Microarrays: Bridging the bio–detector interface
Song, Q., Stadler, L. K. J., Peng, J., & Ferrigno, P. K. (2010) · Faraday Discussions · doi:10.1039/c005376g · Cited by 16
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Impedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Self-citationOptical Biosensors for the Detection of Pathogenic Microorganisms
Yoo, S. M., & Lee, S. Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.012 · Cited by 571
Metadata
- Authors
- Luo, X., & Davis, J. J.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 42
- Issue
- 13
- Pages
- 5944
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2147015275
- Cited by
- 460
- References
- 132
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.