Liquid crystal elastomers as substrates for 3D, robust, implantable electronics
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Liquid crystal elastomers are used as substrates for robust, implantable electronics that are planar processed then morph into 3D shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“In this type, spiral means that the ability to circumscribe the nerve, which somewhat limits the variation in nerve diameter (nerve growth), unless the electrodes are stretchable spiral cuffs.[302,361]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [361]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactive oxygen species (ROS) homeostasis and redox regulation in cellular signaling
Ray, P. D., Huang, B.-W., & Tsuji, Y. (2012) · Cellular Signalling · doi:10.1016/j.cellsig.2012.01.008 · Cited by 4,373
Programmable and adaptive mechanics with liquid crystal polymer networks and elastomers
White, T. J., & Broer, D. J. (2015) · Nature Materials · doi:10.1038/nmat4433 · Cited by 1,744
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Weyl Semimetals as Hydrogen Evolution Catalysts
Rajamathi, C. R., Gupta, U., Kumar, N., Yang, H., Sun, Y., Süß, V., Shekhar, C., Schmidt, M., Blumtritt, H., Werner, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606202 · Cited by 1,358
Voxelated liquid crystal elastomers
Ware, T. H., McConney, M. E., Wie, J. J., Tondiglia, V. P., & White, T. J. (2015) · Science · doi:10.1126/science.1261019 · Cited by 1,157
Self-citationStimuli-Responsive Polymer Nanocomposites Inspired by the Sea Cucumber Dermis
Capadona, J. R., Shanmuganathan, K., Tyler, D. J., Rowan, S. J., & Weder, C. (2008) · Science · doi:10.1126/science.1153307 · Cited by 962
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Degradability of Polymers for Implantable Biomedical Devices
Lyu, S., & Untereker, D. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10094033 · Cited by 538
Kinetic approach of oxygen inhibition in ultraviolet- and laser-induced polymerizations
Decker, C., & Jenkins, A. D. (1985) · Macromolecules · doi:10.1021/ma00148a034 · Cited by 527
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343
Stable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
RODGER, D., FONG, A., LI, W., AMERI, H., AHUJA, A., GUTIERREZ, C., LAVROV, I., ZHONG, H., MENON, P., & MENG, E. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 325
3D printed reversible shape changing soft actuators assisted by liquid crystal elastomers
Yuan, C., Roach, D. J., Dunn, C. K., Mu, Q., Kuang, X., Yakacki, C. M., Wang, T. J., Yu, K., & Qi, H. J. (2017) · Soft Matter · doi:10.1039/c7sm00759k · Cited by 300
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Yang, H., Buguin, A., Taulemesse, J.-M., Kaneko, K., Méry, S., Bergeret, A., & Keller, P. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905363f · Cited by 281
Characterization of parylene C as an encapsulation material for implanted neural prostheses
Hassler, C., von Metzen, R. P., Ruther, P., & Stieglitz, T. (2010) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31584 · Cited by 264
Soft Actuators Based on Liquid‐Crystalline Elastomers
Yu, Y., & Ikeda, T. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601760 · Cited by 248
Encapsulation of an Integrated Neural Interface Device With Parylene C
Hsu, J.-M., Rieth, L., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241
Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
Cheung, K. C., Renaud, P., Tanila, H., & Djupsund, K. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.035 · Cited by 230
Liquid crystalline elastomers as artificial muscles
Wermter, H., & Finkelmann, H. (2001) · e-Polymers · doi:10.1515/epoly.2001.1.1.111 · Cited by 219
Christenson, E. M., Anderson, J. M., & Hiltner, A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30067 · Cited by 219
Optimized Structural Designs for Stretchable Silicon Integrated Circuits
Kim, D., Liu, Z., Kim, Y., Wu, J., Song, J., Kim, H., Huang, Y., Hwang, K., Zhang, Y., & Rogers, J. A. (2009) · Small · doi:10.1002/smll.200900853 · Cited by 184
Self-citationParylene-based flexible neural probes with PEDOT coated surface for brain stimulation and recording
Castagnola, V., Descamps, E., Lecestre, A., Dahan, L., Remaud, J., Nowak, L. G., & Bergaud, C. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.004 · Cited by 183
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
Fabrication of Responsive, Softening Neural Interfaces
Ware, T., Simon, D., Arreaga‐Salas, D. E., Reeder, J., Rennaker, R., Keefer, E. W., & Voit, W. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200200 · Cited by 165
Self-citationUltra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle
Xiang, Z., Yen, S.-C., Xue, N., Sun, T., Tsang, W. M., Zhang, S., Liao, L.-D., Thakor, N. V., & Lee, C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/6/065015 · Cited by 159
3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Yu, L., Gutierrez, C. A., Hoang, T. Q., Pikov, V, & Meng, E. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155
Browning, M. B., Cereceres, S. N., Luong, P. T., & Cosgriff-Hernandez, E. M. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35096 · Cited by 133
Elastomeric substrates with embedded stiff platforms for stretchable electronics
Romeo, A., Liu, Q., Suo, Z., & Lacour, S. P. (2013) · Applied Physics Letters · doi:10.1063/1.4799653 · Cited by 117
Monolithic Encapsulation of Implantable Neuroprosthetic Devices Using Liquid Crystal Polymers
Lee, S. W., Min, K. S., Jeong, J., Kim, J., & Kim, S. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2136341 · Cited by 116
Minnikanti, S., Diao, G., Pancrazio, J. J., Xie, X., Rieth, L. W., Solzbacher, F., & Peixoto, N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.031 · Cited by 113
Self-citationSilicone substrate with in situ strain relief for stretchable thin-film transistors
Graz, I. M., Cotton, D. P. J., Robinson, A., & Lacour, S. P. (2011) · Applied Physics Letters · doi:10.1063/1.3570661 · Cited by 111
Mechanically adaptive nanocomposites for neural interfacing
Capadona, J. R., Tyler, D. J., Zorman, C. A., Rowan, S. J., & Weder, C. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.97 · Cited by 101
Toward Bioelectronic Medicine—Neuromodulation of Small Peripheral Nerves Using Flexible Neural Clip
Lee, S., Peh, W. Y. X., Wang, J., Yang, F., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2017) · Advanced Science · doi:10.1002/advs.201700149 · Cited by 96
Lai, H.-Y., Liao, L.-D., Lin, C.-T., Hsu, J.-H., He, X., Chen, Y.-Y., Chang, J.-Y., Chen, H.-F., Tsang, S., & Shih, Y.-Y. I. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036001 · Cited by 83
A Flexible Depth Probe Using Liquid Crystal Polymer
Lee, S. E., Jun, S. B., Lee, H. J., Kim, J., Lee, S. W., Im, C., Shin, H.-C., Chang, J. W., & Kim, S. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2196274 · Cited by 83
Melatonin improves quality and longevity of chronic neural recording
Golabchi, A., Wu, B., Li, X., Carlisle, D. L., Kozai, T. D. Y., Friedlander, R. M., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.026 · Cited by 80
Responsive, 3D Electronics Enabled by Liquid Crystal Elastomer Substrates
Kim, H., Gibson, J., Maeng, J., Saed, M. O., Pimentel, K., Rihani, R. T., Pancrazio, J. J., Georgakopoulos, S. V., & Ware, T. H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b04189 · Cited by 73
Self-citationThe effects of porosity on endothelialization of ePTFE implanted in subcutaneous and adipose tissue
Salzmann, D. L., Kleinert, L. B., Berman, S. S., & Williams, S. K. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19970315)34:4<463::aid-jbm7>3.0.co;2-i · Cited by 68
Antioxidant inhibition of poly(carbonate urethane) in vivo biodegradation
Christenson, E. M., Anderson, J. M., & Hiltner, A. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30506 · Cited by 64
Dempsey, D. K., Carranza, C., Chawla, C. P., Gray, P., Eoh, J. H., Cereceres, S., & Cosgriff‐Hernandez, E. M. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35037 · Cited by 62
Weems, A. C., Wacker, K. T., Carrow, J. K., Boyle, A. J., & Maitland, D. J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.06.030 · Cited by 62
Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer
Wang, K., Liu, C.-C., & Durand, D. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926691 · Cited by 57
Corrosion Behavior of Parylene-Metal-Parylene Thin Films in Saline
Li, W., Rodger, D., Menon, P., & Tai, Y.-C. (2008) · ECS Transactions · doi:10.1149/1.2897437 · Cited by 50
Joshi‐Imre, A., Black, B., Abbott, J., Kanneganti, A., Rihani, R. T., Chakraborty, B., Danda, V. R., Maeng, J., Sharma, R., Rieth, L. W., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab1bc8 · Cited by 46
Self-citationSchubert, M. A., Wiggins, M. J., Anderson, J. M., & Hiltner, A. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19970315)34:4<493::aid-jbm10>3.0.co;2-e · Cited by 41
On‐Demand Wrinkling Patterns in Thin Metal Films Generated from Self‐Assembling Liquid Crystals
de Haan, L. T., Leclère, P. E. L. G., Damman, P., Schenning, A. P. H. J., & Debije, M. G. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201403399 · Cited by 34
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
Self-citationHydrolysis of the Nafion ® precursor studied by X-ray scattering and in-situ atomic force microscopy
Elliott, J. A., James, P. J., McMaster, T. J., Newton, J. M., Elliott, A. M. S., Hanna, S., & Miles, M. J. (2001) · e-Polymers · doi:10.1515/epoly.2001.1.1.210 · Cited by 29
Environmental Aging and Deadhesion of Polyimide Dielectric Films
Murray, S., Hillman, C., & Pecht, M. (2004) · Journal of Electronic Packaging · doi:10.1115/1.1773853 · Cited by 27
Polymer-based interconnection cables to integrate with flexible penetrating microelectrode arrays
Oh, K., Byun, D., & Kim, S. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0217-9 · Cited by 19
Rajamathi, C. R., Gupta, U., Kumar, N., Yang, H., Sun, Y., Süβ, V., Shekhar, C., Schmidt, M., Yan, B., Parkin, S., et al. (2016) · arXiv · doi:10.48550/arxiv.1608.03783 · Cited by 3
Research works printed but not linked: 3
- Thannickal, 2000, Am. J. Physiol.: Lung Cell. Mol. Physiol., 279, L1005
- Zeng, 2017, Adv. Mater., 29, 1
- Browning, 2014, J. Biomed. Mater. Res., Part A, 102, 4244
Cited by
Liquid Crystals: Versatile Self-Organized Smart Soft Materials
Bisoyi, H. K., & Li, Q. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00761 · Cited by 794
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine
Balakrishnan, G., Song, J., Mou, C., & Bettinger, C. J. (2022) · Advanced Materials · doi:10.1002/adma.202106787 · Cited by 137
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Processing advances in liquid crystal elastomers provide a path to biomedical applications
Ambulo, C. P., Tasmim, S., Wang, S., Abdelrahman, M. K., Zimmern, P. E., & Ware, T. H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021143 · Cited by 107
Self-citation
Metadata
- Authors
- Maeng, J., Rihani, R. T., Javed, M., Rajput, J. S., Kim, H., Bouton, I. G., Criss, T. A., Pancrazio, J. J., Black, B. J., & Ware, T. H.
- Affiliations
- The University of Texas at Dallas (US)
- Qualia Inc.
- Corresponding author
- Ware, Taylor H.
- ORCID
- Venue
- Journal of Materials Chemistry B
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2020
- Volume
- 8
- Issue
- 29
- Pages
- 6286-6295
- ISSN
- 2050-750X (ISSN-L)
- 2050-7518
- OpenAlex
- W3017222569
- Cited by
- 31
- References
- 55
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 11 · 2020: 1
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Materials Chemistry B (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (1711383, 1752846)
- Defense Advanced Research Projects Agency (140D6318C0097)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- liquid crystal elastomers, implantable electronics, twisted nematic liquid crystal, photolithography, chemical durability, hydrolytic stability, stretchable electrodes, electrode arrays, neural interfaces, biosensors
- MeSH terms
- Equipment Design, Biosensing Techniques, Prostheses and Implants, Elastomers, Liquid Crystals, Electrical Equipment and Supplies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.