Cited by 919Systemic Lupus Erythematosus ResearchBlood Coagulation and Thrombosis MechanismsVenous Thromboembolism Diagnosis and Management

A comparison of two intensities of warfarin for the prevention of recurrent thrombosis in patients with the antiphospholipid antibody syndrome

Open access
Crowther, Mark A., Ginsberg, Jeff S., Julian, Jim, Denburg, Judah, Hirsh, Jack, Douketis, James, Laskin, Carl, Fortin, Paul +11 more·2003·New England Journal of Medicine

Abstract

BACKGROUND: Many patients with the antiphospholipid antibody syndrome and recurrent thrombosis receive doses of warfarin adjusted to achieve an international normalized ratio (INR) of more than 3.0. However, there are no prospective data to support this approach to thromboprophylaxis. METHODS: We performed a randomized, double-blind trial in which patients with antiphospholipid antibodies and previous thrombosis were assigned to receive enough warfarin to achieve an INR of 2.0 to 3.0 (moderate intensity) or 3.1 to 4.0 (high intensity). Our objective was to show that high-intensity warfarin was more effective in preventing thrombosis than moderate-intensity warfarin. RESULTS: A total of 114 patients were enrolled in the study and followed for a mean of 2.7 years. Recurrent thrombosis occurred in 6 of 56 patients (10.7 percent) assigned to receive high-intensity warfarin and in 2 of 58 patients (3.4 percent) assigned to receive moderate-intensity warfarin (hazard ratio for the high-intensity group, 3.1; 95 percent confidence interval, 0.6 to 15.0). Major bleeding occurred in three patients assigned to receive high-intensity warfarin and four patients assigned to receive moderate-intensity warfarin (hazard ratio, 1.0; 95 percent confidence interval, 0.2 to 4.8). CONCLUSIONS: High-intensity warfarin was not superior to moderate-intensity warfarin for thromboprophylaxis in patients with antiphospholipid antibodies and previous thrombosis. The low rate of recurrent thrombosis among patients in whom the target INR was 2.0 to 3.0 suggests that moderate-intensity warfarin is appropriate for patients with the antiphospholipid antibody syndrome.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa035241

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In patients with antiphospholipid syndrome and first venous thrombosis, there is no additional benefit of a vitamin K antagonist target INR of 3-4 versus 2-3, based on an RCT and pooled data from five studies that included a majority with venous events.

    “Data from an RCT21 reporting exclusively on patients with venous events and pooled data from five studies that included a majority with venous events21–25 showed no additional benefit of a target INR of 3–4 vs INR of 2–3.”

    From EULAR recommendations for the management of antiphospholipid syndrome in adults (2019) · cites this paper as [21]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • In one trial that provided data specifically on patients with arterial thrombosis, there was no difference in recurrences between those treated to a target INR of 2-3 or INR of 3-4 but without statistical significance (HR 3.1 (0.3-30.0)), although the sample was small and achievement of a target INR of 3-4 was low.

    “In one trial that provided data specifically on patients with arterial thrombosis, there was no difference in recurrences between those treated to a target INR of 2–3 or INR of 3–4 but without statistical significance (HR 3.1 (0.3–30.0)), although the sample was small and the achievement of a target INR of 3–4 was low.21”
  • Pooled data from two retrospective studies and two RCTs showed no statistically significant difference in thrombosis recurrences between vitamin K antagonist target INR 3-4 and INR 2-3 (relative risk 0.46 (0.06-3.52)).

    “Pooled data from two retrospective studies and two RCTs21–24 showed that there was no statistically significant difference in thrombosis recurrences between treatment with VKA with a target INR of 3–4 and treatment with INR of 2–3 (relative risk (RR) 0.46 (0.06–3.52)).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. Crowther MA, Ginsberg JS. Antiphos- pholipid antibody syndrome. In: Goldhaber SZ, Ridker PM, eds. Thrombosis and throm- boembolism. Vol. 44 of Fundamental and clinical cardiology. New York: Marcel Dek- ker, 2002:49-66.
  2. Khamashta MA, Cuadrado MJ, Mujic F, Taub NA, Hunt BJ, Hughes GRV. The man- agement of thrombosis in the antiphospho- lipid-antibody syndrome. N Engl J Med 1995;332:993-7.
  3. Kearon C, Gent M, Hirsh J, et al. A com- parison of three months of anticoagulation with extended anticoagulation for a first ep- isode of idiopathic venous thromboembo- lism. N Engl J Med 1999;340:901-7. [
  4. Erra- tum, N Engl J Med 1999;341:298.]

Cited by

Sorted by citations

Authors
Crowther, M. A., Ginsberg, J. S., Julian, J., Denburg, J., Hirsh, J., Douketis, J., Laskin, C., Fortin, P., Anderson, D., Kearon, C., Clarke, A., Geerts, W., Forgie, M., Green, D., Costantini, L., Yacura, W., Wilson, S., Gent, M., & Kovacs, M. J.
Affiliations
  • McMaster University (CA)
  • University of Toronto (CA)
  • Dalhousie University (CA)
  • McGill University (CA)
  • University of Ottawa (CA)
  • Northwestern University (US)
  • Western University (CA)
Venue
New England Journal of Medicine
Published
2003-09-18
Volume
349
Issue
12
Pages
1133-1138
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2053081517
Cited by
919
References
10
Citations by year
2026: 8 · 2025: 21 · 2024: 31 · 2023: 24 · 2022: 23 · 2021: 32 · 2020: 34 · 2019: 37 · 2018: 38 · 2017: 28 · 2016: 37 · 2015: 42 · 2014: 35 · 2013: 34 · 2012: 47
FWCI
34.28
Type
journal article
Language
en
Open access
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Heart and Stroke Foundation of Canada
  • Arthritis Society
  • University of Toronto
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
Keywords
antiphospholipid syndrome, warfarin, recurrent thrombosis, thromboprophylaxis, international normalized ratio, anticoagulation intensity, major bleeding, antithrombotic therapy
MeSH terms
Adult, Aged, Aged, 80 and over, Anticoagulants, Double-Blind Method, Female, Follow-Up Studies, Hemorrhage, Humans, Male, Middle Aged, Myocardial Infarction, Pulmonary Embolism, Warfarin, Antiphospholipid Syndrome, Antibodies, Antiphospholipid, International Normalized Ratio, Venous Thrombosis, Stroke, Secondary Prevention

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›