The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Open accessAbstract
Computer-controlled microfluidics would advance many types of cellular assays and microscale tissue engineering studies wherever spatiotemporal changes in fluidics need to be defined. However, this goal has been elusive because of the limited availability of integrated, programmable pumps and valves. This paper demonstrates how a refreshable Braille display, with its grid of 320 vertically moving pins, can power integrated pumps and valves through localized deformations of channel networks within elastic silicone rubber. The resulting computerized fluidic control is able to switch among: ( i ) rapid and efficient mixing between streams, ( ii ) multiple laminar flows with minimal mixing between streams, and ( iii ) segmented plug-flow of immiscible fluids within the same channel architecture. The same control method is used to precisely seed cells, compartmentalize them into distinct subpopulations through channel reconfiguration, and culture each cell subpopulation for up to 3 weeks under perfusion. These reliable microscale cell cultures showed gradients of cellular behavior from C2C12 myoblasts along channel lengths, as well as differences in cell density of undifferentiated myoblasts and differentiation patterns, both programmable through different flow rates of serum-containing media. This technology will allow future microscale tissue or cell studies to be more accessible, especially for high-throughput, complex, and long-term experiments. The microfluidic actuation method described is versatile and computer programmable, yet simple, well packaged, and portable enough for personal use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Surface-Directed Liquid Flow Inside Microchannels
Zhao, B., Moore, J. S., & Beebe, D. J. (2001) · Science · doi:10.1126/science.291.5506.1023 · Cited by 765
Microfluidic Device for Single-Cell Analysis
Wheeler, A. R., Throndset, W. R., Whelan, R. J., Leach, A. M., Zare, R. N., Liao, Y. H., Farrell, K., Manger, I. D., & Daridon, A. (2003) · Analytical Chemistry · doi:10.1021/ac0340758 · Cited by 600
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
Patterning cells and their environments using multiple laminar fluid flows in capillary networks
Takayama, S., McDonald, J. C., Ostuni, E., Liang, M. N., Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5545 · Cited by 528
Self-citationSikavitsas, V. I., Bancroft, G. N., Holtorf, H. L., Jansen, J. A., & Mikos, A. G. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2434367100 · Cited by 472
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Morphogens, their identification and regulation
Tabata, T., & Takei, Y. (2004) · Development · doi:10.1242/dev.01043 · Cited by 445
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
A rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383
Enhancement of microfluidic mixing using time pulsing
Glasgow, I., & Aubry, N. (2003) · Lab Chip · doi:10.1039/b302569a · Cited by 370
Sin, A., Chin, K. C., Jamil, M. F., Kostov, Y., Rao, G., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp034077d · Cited by 368
Passively Driven Integrated Microfluidic System for Separation of Motile Sperm
Cho, B. S., Schuster, T. G., Zhu, X., Chang, D., Smith, G. D., & Takayama, S. (2003) · Analytical Chemistry · doi:10.1021/ac020579e · Cited by 356
Self-citationCell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
A Myogenic Cell Line with Altered Serum Requirements for Differentiation
YAFFE, D., & SAXEL, O. (1977) · Differentiation · doi:10.1111/j.1432-0436.1977.tb01507.x · Cited by 313
Emrich, C. A., Tian, H., Medintz, I. L., & Mathies, R. A. (2002) · Analytical Chemistry · doi:10.1021/ac020236g · Cited by 284
Formation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
Selective Chemical Treatment of Cellular Microdomains Using Multiple Laminar Streams
Takayama, S., Ostuni, E., LeDuc, P., Naruse, K., Ingber, D. E., & Whitesides, G. M. (2003) · Chemistry & Biology · doi:10.1016/s1074-5521(03)00019-x · Cited by 210
Self-citationSample Filtration, Concentration, and Separation Integrated on Microfluidic Devices
Broyles, B. S., Jacobson, S. C., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac025503x · Cited by 174
Microfluidic technology for assisted reproduction
Beebe, D. J., Wheeler, M. B., Zeringue, H. C., Walters, E. M., & Raty, S. (2002) · Theriogenology · doi:10.1016/s0093-691x(01)00662-8 · Cited by 157
Mathematical modeling of drop mixing in a slit-type microchannel
Handique, K., & Burns, M. A. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/5/316 · Cited by 116
An evaporation-based microfluidic sample concentration method
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b202473j · Cited by 107
An Evaporation-Based Disposable Micropump Concept for Continuous Monitoring Applications
Effenhauser, C. S., Harttig, H., & Krämer, P. (2002) · Biomedical Microdevices · doi:10.1023/a:1014215728074 · Cited by 64
Ledezma, G. A., Folch, A., Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798043 · Cited by 57
Cited by
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
A microfluidic culture platform for CNS axonal injury, regeneration and transport
Taylor, A. M., Blurton-Jones, M., Rhee, S. W., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Nature Methods · doi:10.1038/nmeth777 · Cited by 1,153
Metadata
- Authors
- Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-10-28
- Volume
- 101
- Issue
- 45
- Pages
- 15861-15866
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2061144522
- Cited by
- 403
- References
- 32
- FWCI
- 20.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.