Mechanotransduction and flow across the endothelial glycocalyx
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
In this inaugural paper, we shall provide an overview of the endothelial surface layer or glycocalyx in several roles: as a transport barrier, as a porous hydrodynamic interface in the motion of red and white cells in microvessels, and as a mechanotransducer of fluid shearing stresses to the actin cortical cytoskeleton of the endothelial cell. These functions will be examined from a new perspective, the quasiperiodic ultrastructural model proposed in Squire et al. [Squire, J. M., Chew, M., Nneji, G., Neal, C., Barry, J. & Michel, C. (2001)J. Struct. Biol.136, 239–255] for the 3D organization of the endothelial surface layer and its linkage to the submembranous scaffold. We shall show that the core proteins in the bush-like structures comprising the matrix have a flexural rigidity,EI, that is sufficiently stiff to serve as a molecular filter for plasma proteins and as an exquisitely designed transducer of fluid shearing stresses. However,EI is inadequate to prevent the buckling of these protein structures during the intermittent motion of red cells or the penetration of white cell microvilli. In these cellular interactions, the viscous draining resistance of the matrix is essential for preventing adhesive molecular interactions between proteins in the endothelial membrane and circulating cellular components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Transmembrane crosstalk between the extracellular matrix and the cytoskeleton
Geiger, B., Bershadsky, A., Pankov, R., & Yamada, K. M. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35099066 · Cited by 2,209
Flexural rigidity of microtubules and actin filaments measured from thermal fluctuations in shape.
Gittes, F., Mickey, B., Nettleton, J., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.4.923 · Cited by 1,817
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Michel, C. C., & Curry, F. E. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.3.703 · Cited by 811
Force measurements by micromanipulation of a single actin filament by glass needles
Kishino, A., & Yanagida, T. (1988) · Nature · doi:10.1038/334074a0 · Cited by 679
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615
Self-citationRole of Integrins in Endothelial Mechanosensing of Shear Stress
Shyy, J. Y.-J., & Chien, S. (2002) · Circulation Research · doi:10.1161/01.res.0000038487.19924.18 · Cited by 549
Fine structures of capillary and endocapillary layer as revealed by ruthenium red.
Luft, J. H. (1966) · PubMed · Cited by 504
Cited by
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“Endothelial glycocalyx, a carbohydrate-rich layer that is a network of membrane-bound proteoglycans and glycoproteins lining the luminal side of endothelium, may serve as a mechanosensor to transmit mechanical forces into biochemical signals in ECs (181, 470, 608, 610, 635).”
BackgroundThe endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Self-citationSignaling Mechanisms Regulating Endothelial Permeability
Mehta, D., & Malik, A. B. (2006) · Physiological Reviews · doi:10.1152/physrev.00012.2005 · Cited by 1,720
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationLevi, M., & van der Poll, T. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181c98d21 · Cited by 984
Mechanotransduction and endothelial cell homeostasis: the wisdom of the cell
Chien, S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01047.2006 · Cited by 907
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
MICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Mechanisms of Mechanotransduction
Orr, A. W., Helmke, B. P., Blackman, B. R., & Schwartz, M. A. (2006) · Developmental Cell · doi:10.1016/j.devcel.2005.12.006 · Cited by 798
Inflammation, endothelium, and coagulation in sepsis
Schouten, M., Wiersinga, W. J., Levi, M., & van der Poll, T. (2008) · Journal of Leukocyte Biology · doi:10.1189/jlb.0607373 · Cited by 629
Nieuwdorp, M., van Haeften, T. W., Gouverneur, M. C. L. G., Mooij, H. L., van Lieshout, M. H. P., Levi, M., Meijers, J. C. M., Holleman, F., Hoekstra, J. B. L., Vink, H., et al. (2006) · Diabetes · doi:10.2337/diabetes.55.02.06.db05-1103 · Cited by 620
Self-citationSarin, H. (2010) · Journal of Angiogenesis Research · doi:10.1186/2040-2384-2-14 · Cited by 562
Mechanotransduction and strain amplification in osteocyte cell processes
Han, Y., Cowin, S. C., Schaffler, M. B., & Weinbaum, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407429101 · Cited by 496
Self-citationMolecular Biology of Atherosclerosis
Hopkins, P. N. (2013) · Physiological Reviews · doi:10.1152/physrev.00004.2012 · Cited by 459
Mechanotransduction and the glycocalyx
TARBELL, J. M., & PAHAKIS, M. Y. (2006) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2006.01620.x · Cited by 435
Investigating cell mechanics with atomic force microscopy
Haase, K., & Pelling, A. E. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0970 · Cited by 396
The role of endothelial glycocalyx components in mechanotransduction of fluid shear stress
Pahakis, M. Y., Kosky, J. R., Dull, R. O., & Tarbell, J. M. (2007) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2007.01.137 · Cited by 390
Mechanobiology in the Third Dimension
Pedersen, J. A., & Swartz, M. A. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8159-4 · Cited by 389
Endothelial permeability, LDL deposition, and cardiovascular risk factors—a review
Mundi, S., Massaro, M., Scoditti, E., Carluccio, M. A., van Hinsbergh, V. W. M., Iruela-Arispe, M. L., & De Caterina, R. (2018) · Cardiovascular Research · doi:10.1093/cvr/cvx226 · Cited by 367
Microvascular blood viscosity in vivo and the endothelial surface layer
Pries, A. R., & Secomb, T. W. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00297.2005 · Cited by 349
Thi, M. M., Tarbell, J. M., Weinbaum, S., & Spray, D. C. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407474101 · Cited by 325
Self-citationOncotic pressures opposing filtration across non‐fenestrated rat microvessels
Adamson, R. H., Lenz, J. F., Zhang, X., Adamson, G. N., Weinbaum, S., & Curry, F. E. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.058255 · Cited by 323
Self-citationEndothelial Glycocalyx: Permeability Barrier and Mechanosensor
Curry, F. E., & Adamson, R. H. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0429-8 · Cited by 312
The endothelial glycocalyx: a potential barrier between health and vascular disease
Nieuwdorp, M., Meuwese, M. C., Vink, H., Hoekstra, J. B., Kastelein, J. J., & Stroes, E. S. (2005) · Current Opinion in Lipidology · doi:10.1097/01.mol.0000181325.08926.9c · Cited by 309
Self-citationGlomerular Endothelial Glycocalyx Constitutes a Barrier to Protein Permeability
Singh, A., Satchell, S. C., Neal, C. R., McKenzie, E. A., Tooke, J. E., & Mathieson, P. W. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007010119 · Cited by 300
Damage of the Endothelial Glycocalyx in Dialysis Patients
Vlahu, C. A., Lemkes, B. A., Struijk, D. G., Koopman, M. G., Krediet, R. T., & Vink, H. (2012) · Journal of the American Society of Nephrology · doi:10.1681/asn.2011121181 · Cited by 274
Self-citationA model for the role of integrins in flow induced mechanotransduction in osteocytes
Wang, Y., McNamara, L. M., Schaffler, M. B., & Weinbaum, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707246104 · Cited by 265
Self-citationReactive oxygen species mediate modification of glycocalyx during ischemia-reperfusion injury
Rubio-Gayosso, I., Platts, S. H., & Duling, B. R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00796.2005 · Cited by 262
Mechanotransduction in endothelial cell migration
Li, S., Huang, N. F., & Hsu, S. (2005) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20614 · Cited by 260
Osteocyte lacunae tissue strain in cortical bone
Nicolella, D. P., Moravits, D. E., Gale, A. M., Bonewald, L. F., & Lankford, J. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.032 · Cited by 253
Salt overload damages the glycocalyx sodium barrier of vascular endothelium
Oberleithner, H., Peters, W., Kusche-Vihrog, K., Korte, S., Schillers, H., Kliche, K., & Oberleithner, K. (2011) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-011-0999-1 · Cited by 235
Yao, Y., Rabodzey, A., & Dewey, C. F. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00162.2007 · Cited by 222
Dendritic processes of osteocytes are mechanotransducers that induce the opening of hemichannels
Burra, S., Nicolella, D. P., Francis, W. L., Freitas, C. J., Mueschke, N. J., Poole, K., & Jiang, J. X. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1009382107 · Cited by 211
“The glycocalyx present in the endothelial extracellular matrix has been shown to act as a transducer of mechanical signals in endothelial cells and is involved in changes in the actin cytoskeletal organization (19, 20).”
BackgroundEltzschig, H. K., Faigle, M., Knapp, S., Karhausen, J., Ibla, J., Rosenberger, P., Odegard, K. C., Laussen, P. C., Thompson, L. F., & Colgan, S. P. (2006) · Blood · doi:10.1182/blood-2006-02-001016 · Cited by 188
Primary cilia sensitize endothelial cells for fluid shear stress
Hierck, B. P., Van der Heiden, K., Alkemade, F. E., Van de Pas, S., Van Thienen, J. V., Groenendijk, B. C. W., Bax, W. H., Van der Laarse, A., DeRuiter, M. C., Horrevoets, A. J. G., et al. (2008) · Developmental Dynamics · doi:10.1002/dvdy.21472 · Cited by 187
Gao, L., & Lipowsky, H. H. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.06.005 · Cited by 182
“…potential impact on permeability using techniques of electron microscopy (Squire et al., 2001; Van den Berg et al., 2003), intravital microscopy (Henry and Duling, 1999; Vink and Duling, 2000) and mathematical modeling (Stace and Damiano, 2001; Sugihara-Seki et al., 2008; Weinbaum et al., 2003).”
Mechanosensing at the Vascular Interface
Tarbell, J. M., Simon, S. I., & Curry, F.-R. E. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104908 · Cited by 180
“Structures below this surface region are not exposed to fluid shear forces (11, 78).”
BackgroundEndothelial cell dysfunction and glycocalyx – A vicious circle
Zhang, X., Sun, D., Song, J. W., Zullo, J., Lipphardt, M., Coneh-Gould, L., & Goligorsky, M. S. (2018) · Matrix Biology · doi:10.1016/j.matbio.2018.01.026 · Cited by 178
Self-citationThe Effects of Hemodynamic Force on Embryonic Development
CULVER, J. C., & DICKINSON, M. E. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00025.x · Cited by 173
Fu, B. M., & Tarbell, J. M. (2013) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1211 · Cited by 175
The Hydrodynamically Relevant Endothelial Cell Glycocalyx Observed In Vivo Is Absent In Vitro
Potter, D. R., & Damiano, E. R. (2008) · Circulation Research · doi:10.1161/circresaha.107.160226 · Cited by 173
Tissue strain amplification at the osteocyte lacuna: A microstructural finite element analysis
Rath Bonivtch, A., Bonewald, L. F., & Nicolella, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.10.040 · Cited by 168
“…6965. esses: daniel.nicolella@swri.org, i.edu (D.P. Nicolella). tion of osteocyte cell processes within canaliculi have gained the most prominence (Weinbaum et al., 1994, 2003; You et al., 2001; Han et al., 2004; Cowin, 2002) since it has been shown that direct mechanical strain applied to cells…”
Endothelial Mechanosignaling: Does One Sensor Fit All?
Givens, C., & Tzima, E. (2016) · Antioxidants & Redox Signaling · doi:10.1089/ars.2015.6493 · Cited by 165
“Instead, syndecans link to the cytoskeleton through their cytoplasmic termini, providing a possible mechanism for force transfer from shear stress to the cytoskeleton (136, 143, 152).”
BackgroundCardiovascular manifestations of the emerging dengue pandemic
Yacoub, S., Wertheim, H., Simmons, C. P., Screaton, G., & Wills, B. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.40 · Cited by 163
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
The Fluid Mechanics of Cancer and Its Therapy
Koumoutsakos, P., Pivkin, I., & Milde, F. (2013) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101102 · Cited by 129
“…is a fibrous, brush-like structure of long-chained macromolecules and proteins that covers the luminal endothelium in a thin layer (with an estimated thickness between 60 and 570 nm) and is connected to the actin cortical cytoskeleton of the EC (Tarbell et al. 2005, Weinbaum et al. 2003).”
BackgroundStructure and Response to Flow of the Glycocalyx Layer
Cruz-Chu, E. R., Malafeev, A., Pajarskas, T., Pivkin, I. V., & Koumoutsakos, P. (2014) · Biophysical Journal · doi:10.1016/j.bpj.2013.09.060 · Cited by 87
“(15) have presented a quasiperiodic hexagonal arrangement for a glycocalyx with a spacing of 100 nm between proteoglycan clusters.”
The development of the heart and microcirculation: role of shear stress
Poelmann, R. E., Gittenberger-de Groot, A. C., & Hierck, B. P. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0304-4 · Cited by 62
“, integrins and caveolae, but also cell junctions and adhesion molecules [30, 49, 56].”
BackgroundChen, K., Linares, I. M., Trempel, M. A., Feidler, A. M., De Silva, D., Farajollahi, S., Jones, J., Kuebel, J., Kasap, P., Engelhardt, B., et al. (2025) · Advanced Science · doi:10.1002/advs.202508271 · Cited by 9
Metadata
- Authors
- Weinbaum, S., Zhang, X., Han, Y., Vink, H., & Cowin, S. C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-06-16
- Volume
- 100
- Issue
- 13
- Pages
- 7988-7995
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2034248554
- Cited by
- 579
- References
- 38
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.