The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Origin of nanomechanical cantilever motion generated from biomolecular interactions
Open accessAbstract
Generation of nanomechanical cantilever motion from biomolecular interactions can have wide applications, ranging from high-throughput biomolecular detection to bioactuation. Although it has been suggested that such motion is caused by changes in surface stress of a cantilever beam, the origin of the surface-stress change has so far not been elucidated. By using DNA hybridization experiments, we show that the origin of motion lies in the interplay between changes in configurational entropy and intermolecular energetics induced by specific biomolecular interactions. By controlling entropy change during DNA hybridization, the direction of cantilever motion can be manipulated. These thermodynamic principles were also used to explain the origin of motion generated from protein–ligand binding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The tension of metallic films deposited by electrolysis
Stoney, G. G. (1909) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1909.0021 · Cited by 4,872
Smith, S. B., Cui, Y., & Bustamante, C. (1996) · Science · doi:10.1126/science.271.5250.795 · Cited by 2,770
Single myosin molecule mechanics: piconewton forces and nanometre steps
Finer, J. T., Simmons, R. M., & Spudich, J. A. (1994) · Nature · doi:10.1038/368113a0 · Cited by 1,915
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
The Way Things Move: Looking Under the Hood of Molecular Motor Proteins
Vale, R. D., & Milligan, R. A. (2000) · Science · doi:10.1126/science.288.5463.88 · Cited by 1,503
Thermodynamics and Kinetics of a Brownian Motor
Astumian, R. D. (1997) · Science · doi:10.1126/science.276.5314.917 · Cited by 1,411
Fleer, G. J., Stuart, M. A. C., Scheutjens, J. M. H. M., Cosgrove, T., & Vincent, B. (1998) · Springer eBooks · doi:10.1007/978-94-011-2130-9 · Cited by 1,403
Ionic effects on the elasticity of single DNA molecules
Baumann, C. G., Smith, S. B., Bloomfield, V. A., & Bustamante, C. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6185 · Cited by 1,001
Fluctuation driven ratchets: Molecular motors
Astumian, R. D., & Bier, M. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.1766 · Cited by 923
Cited by
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Erbas-Cakmak, S., Leigh, D. A., McTernan, C. T., & Nussbaumer, A. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00146 · Cited by 1,982
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Self-citationThe effect of surface probe density on DNA hybridization
Peterson, A. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.24.5163 · Cited by 976
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
High-throughput screening assays for the identification of chemical probes
Inglese, J., Johnson, R. L., Simeonov, A., Xia, M., Zheng, W., Austin, C. P., & Auld, D. S. (2007) · Nature Chemical Biology · doi:10.1038/nchembio.2007.17 · Cited by 614
McKendry, R., Zhang, J., Arntz, Y., Strunz, T., Hegner, M., Lang, H. P., Baller, M. K., Certa, U., Meyer, E., Güntherodt, H.-J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152330199 · Cited by 598
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Single cell detection with micromechanical oscillators
Ilic, B., Czaplewski, D., Zalalutdinov, M., Craighead, H. G., Neuzil, P., Campagnolo, C., & Batt, C. (2001) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.1421572 · Cited by 443
Biosensors: the new wave in cancer diagnosis
Mousa, S. (2010) · Nanotechnology, Science and Applications · doi:10.2147/nsa.s13465 · Cited by 381
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Nanotechnology for Early Cancer Detection
Choi, Y.-E., Kwak, J.-W., & Park, J. W. (2010) · Sensors · doi:10.3390/s100100428 · Cited by 329
Micromechanical cantilever as an ultrasensitive pH microsensor
Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A. (2002) · Applied Physics Letters · doi:10.1063/1.1514825 · Cited by 300
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
MOSFET-Embedded Microcantilevers for Measuring Deflection in Biomolecular Sensors
Shekhawat, G., Tark, S.-H., & Dravid, V. P. (2006) · Science · doi:10.1126/science.1122588 · Cited by 286
A label-free immunosensor array using single-chain antibody fragments
Backmann, N., Zahnd, C., Huber, F., Bietsch, A., Plückthun, A., Lang, H.-P., Güntherodt, H.-J., Hegner, M., & Gerber, C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504917102 · Cited by 284
Surface grafted polymer brushes as ideal building blocks for “smart” surfaces
Zhou, F., & Huck, W. T. S. (2006) · Phys. Chem. Chem. Phys. · doi:10.1039/b606415a · Cited by 283
Dissipation in nanoelectromechanical systems
Imboden, M., & Mohanty, P. (2014) · Physics Reports · doi:10.1016/j.physrep.2013.09.003 · Cited by 273
Shen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Wee, K. W., Kang, G. Y., Park, J., Kang, J. Y., Yoon, D. S., Park, J. H., & Kim, T. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.023 · Cited by 272
Biosensor Recognition Elements
(2008) · Current Issues in Molecular Biology · doi:10.21775/cimb.010.001 · Cited by 264
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Microcantilever resonance-based DNA detection with nanoparticle probes
Su, M., Li, S., & Dravid, V. P. (2003) · Applied Physics Letters · doi:10.1063/1.1576915 · Cited by 253
Kinsella, J. M., & Ivanisevic, A. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.313 · Cited by 65
Metadata
- Authors
- Wu, G., Ji, H., Hansen, K., Thundat, T., Datar, R., Cote, R., Hagan, M. F., Chakraborty, A. K., & Majumdar, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-02-06
- Volume
- 98
- Issue
- 4
- Pages
- 1560-1564
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2156720029
- Cited by
- 415
- References
- 20
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.