Review: Recent Developments in Enzyme-Based Biosensors for Biomedical Analysis
The DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Abstract
The need for simple, rapid, cost-effective, and portable screening methods has boosted the development of practical biosensors with applications in clinical monitoring, and diagnosis of disease. Compared with traditional analytical methods, enzyme-based bioanalytical devices have several distinct advantages such as high sensitivity and specificity, portability, cost-effectiveness, and the possibilities for miniaturization and mass production. Additionally, they can be developed for point-of-care diagnostic testing. This paper reviews recent advances in the development of enzyme biosensors, design characteristics, performances, and applications with a focus on electrochemical and optical sensors. Recent emerging technologies and innovative biosensing designs, such as nanosensors, paper based-sensors, lab-on-a-chip, biochips, and microfluidic devices are discussed. Specific applications in bioanalysis, clinical diagnosis, and pharmacology are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The protein kinase complement of the human genome
Manning, G., Whyte, D. B., Martinez, R., Hunter, T., & Sudarsanam, S. (2002) · Science · doi:10.1126/science.1075762 · Cited by 8,145
Quantum Dots for Live Cells, in Vivo Imaging, and Diagnostics
Michalet, X., Pinaud, F. F., Bentolila, L. A., Tsay, J. M., Doose, S., Li, J. J., Sundaresan, G., Wu, A. M., Gambhir, S. S., & Weiss, S. (2005) · Science · doi:10.1126/science.1104274 · Cited by 7,790 · cited 4×
“As compared to organic fluorophores, nanocrystal quantum confinement results in tunable size and fluorescence emission from visible to infrared wavelengths (Michalet et al. 2005).”
BackgroundInfluentialWhitesides, G. M., & Grzybowski, B. (2002) · Science · doi:10.1126/science.1070821 · Cited by 7,439
Quantum Dot Bioconjugates for Ultrasensitive Nonisotopic Detection
Chan, W. C. W., & Nie, S. (1998) · Science · doi:10.1126/science.281.5385.2016 · Cited by 7,278 · cited 1×
“…oxide (TOPO) coating is replaced through a ligand exchange reaction with various thiol-bearing compounds like mercaptoacetic acid (Chan and Nie 1998), dithiothreitol (Pathak et al. 2001), dihydrolipoic acid (Susumu et al. 2009), phospines (Kim and Bawendi 2003), dendrons (Y. Zhao…”
BackgroundBlume-Jensen, P., & Hunter, T. (2001) · Nature · doi:10.1038/35077225 · Cited by 3,738
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124 · cited 1×
“A relatively new material in the biosensing arena is graphene, a form of carbon with remarkable electrical properties, high surface area, excellent conductivity, and mechanical strength (Shan, Yang et al. 2009; Shao et al. 2010; Wu et al. 2010).”
BackgroundPatterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874 · cited 3×
“These low-cost platforms have been integrated with both colorimetric (Martinez et al. 2007; Dungchai et al. 2010) and electrochemical (Dungchai et al.”
MethodNagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
Applications of nanoparticles in biology and medicine
Salata, O. (2004) · Journal of Nanobiotechnology · doi:10.1186/1477-3155-2-3 · Cited by 2,327
Protein kinases — the major drug targets of the twenty-first century?
Cohen, P. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd773 · Cited by 2,186
Creating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979 · cited 2×
“The need for simple, affordable, and rapid methods of diagnosis has promoted the development of inexpensive portable assays for point-of-care testing (Yager et al. 2006; Rivet et al. 2010).”
BackgroundRonkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707 · cited 4×
“…including optical (Borisov and Wolfbeis 2008) and electrochemical sensors (J. Wang 2008; Ronkainen et al. 2010) for in vivo detection (Wilson and Hu 2000; Wilson and Johnson 2008) and diabetes management (Heller and Feldman 2008; J. Wang 2008) have been discussed in several excellent reviews.”
BackgroundMethodInfluentialIn vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591 · cited 2×
“Early and in situ detection of tumors requires availability of biocompatible delivery vehicles of fluorescent probes to ensure tumor delivery and tissue uptake, as well as probes that are capable of producing bright fluorescence upon specific cleavage of elevated proteases (Weissleder et al. 1999; Funovics et al. 2003…”
BackgroundSapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Nanoparticles – known and unknown health risks
Hoet, P. H., Brüske-Hohlfeld, I., & Salata, O. V. (2004) · Journal of Nanobiotechnology · doi:10.1186/1477-3155-2-12 · Cited by 1,374
Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene
Shan, C., Yang, H., Song, J., Han, D., Ivaska, A., & Niu, L. (2009) · Analytical Chemistry · doi:10.1021/ac802193c · Cited by 1,315
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224 · cited 3×
“2010) and electrochemical (Dungchai et al. 2009; Nie, Nijhuis, et al. 2010; Reches et al. 2010) detection systems.”
BackgroundMethodBorisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766 · cited 1×
“Abe and coworkers (Abe et al. 2008) have developed a multianalyte paper based-microfluidic device with 550 mm-wide flow channels by inkjet printing.”
BackgroundBiocompatible Graphene Oxide-Based Glucose Biosensors
Liu, Y., Yu, D., Zeng, C., Miao, Z., & Dai, L. (2010) · Langmuir · doi:10.1021/la100886x · Cited by 709
Hydroxylated Quantum Dots as Luminescent Probes for in Situ Hybridization
Pathak, S., Choi, S.-K., Arnheim, N., & Thompson, M. E. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0058334 · Cited by 614 · cited 2×
“…is replaced through a ligand exchange reaction with various thiol-bearing compounds like mercaptoacetic acid (Chan and Nie 1998), dithiothreitol (Pathak et al. 2001), dihydrolipoic acid (Susumu et al. 2009), phospines (Kim and Bawendi 2003), dendrons (Y. Zhao et al. 2009), or other ligands (X.…”
BackgroundPhotoactivatable mCherry for high-resolution two-color fluorescence microscopy
Subach, F. V., Patterson, G. H., Manley, S., Gillette, J. M., Lippincott-Schwartz, J., & Verkhusha, V. V. (2009) · Nature Methods · doi:10.1038/nmeth.1298 · Cited by 607
Medintz, I. L., Clapp, A. R., Brunel, F. M., Tiefenbrunn, T., Tetsuo Uyeda, H., Chang, E. L., Deschamps, J. R., Dawson, P. E., & Mattoussi, H. (2006) · Nature Materials · doi:10.1038/nmat1676 · Cited by 550 · cited 3×
“, broad excitation, narrow emission, high photostability) (Medintz et al. 2006).”
BackgroundInfluentialA bright and photostable photoconvertible fluorescent protein
McKinney, S. A., Murphy, C. S., Hazelwood, K. L., Davidson, M. W., & Looger, L. L. (2009) · Nature Methods · doi:10.1038/nmeth.1296 · Cited by 547
The role of proteases during apoptosis
Patel, T., Gores, G. J., & Kaufmann, S. H. (1996) · The FASEB Journal · doi:10.1096/fasebj.10.5.8621058 · Cited by 544 · cited 3×
“monogenic disorders, stroke, cancer, Alzheimer’s disease, degenerative diseases due to apoptosis (Patel et al. 1996).”
BackgroundInfluentialUsefulness of lactate dehydrogenase and its isoenzymes as indicators of lung damage or inflammation
Drent, M., Cobben, N., Henderson, R., Wouters, E., & van Dieijen-Visser, M. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09081736 · Cited by 532 · cited 2×
“…adenine dinucleotide) coenzyme of LDH (lactate dehydrogenase) was exploited to quantitatively detect levels of LDH (Ren et al. 2010) which are elevated in serum of patients with ischemia, injury, lung damage and inflammation (Drent et al. 1996), liver diseases (Rotenberg et al. 1989), and so forth.”
BackgroundMethodIntegration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Biochemically functionalized silica nanoparticles
Qhobosheane, M., Santra, S., Zhang, P., & Tan, W. (2001) · The Analyst · doi:10.1039/b101489g · Cited by 452
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434 · cited 4×
“…designs including optical (Borisov and Wolfbeis 2008) and electrochemical sensors (J. Wang 2008; Ronkainen et al. 2010) for in vivo detection (Wilson and Hu 2000; Wilson and Johnson 2008) and diabetes management (Heller and Feldman 2008; J. Wang 2008) have been discussed in several excellent…”
BackgroundInfluentialEmulating biology: Building nanostructures from the bottom up
Seeman, N. C., & Belcher, A. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.221458298 · Cited by 419
Oligomeric Ligands for Luminescent and Stable Nanocrystal Quantum Dots
Kim, S., & Bawendi, M. G. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0368094 · Cited by 411
Use of multiple colorimetric indicators for paper-based microfluidic devices
Dungchai, W., Chailapakul, O., & Henry, C. S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.019 · Cited by 364 · cited 3×
“These low-cost platforms have been integrated with both colorimetric (Martinez et al. 2007; Dungchai et al. 2010) and electrochemical (Dungchai et al.”
BackgroundMethodInfluentialMicrofluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356 · cited 2×
“The need for simple, affordable, and rapid methods of diagnosis has promoted the development of inexpensive portable assays for point-of-care testing (Yager et al. 2006; Rivet et al. 2010).”
BackgroundSynthesis and Application of Quantum Dots FRET-Based Protease Sensors
Shi, L., De Paoli, V., Rosenzweig, N., & Rosenzweig, Z. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063509o · Cited by 352
Hossain, S. M. Z., Luckham, R. E., Smith, A. M., Lebert, J. M., Davies, L. M., Pelton, R. H., Filipe, C. D. M., & Brennan, J. D. (2009) · Analytical Chemistry · doi:10.1021/ac900660p · Cited by 317 · cited 1×
“The bioassay was characterized by good detection limits (100 nM for paraoxon and 30 nM for aflatoxin B1) and rapid response times of <5min (Hossain et al. 2009).”
MethodEnzyme-Doped Graphene Nanosheets for Enhanced Glucose Biosensing
Alwarappan, S., Liu, C., Kumar, A., & Li, C.-Z. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp103273z · Cited by 309 · cited 1×
“2D graphene has been used as a new bio-immobilization matrix (Alwarappan et al. 2010; Liu et al. 2010) providing superior enzyme binding abilities.”
MethodRecent advances in material science for developing enzyme electrodes
Sarma, A. K., Vatsyayan, P., Goswami, P., & Minteer, S. D. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.026 · Cited by 303
Sensing Caspase 3 Activity with Quantum Dot−Fluorescent Protein Assemblies
Boeneman, K., Mei, B. C., Dennis, A. M., Bao, G., Deschamps, J. R., Mattoussi, H., & Medintz, I. L. (2009) · Journal of the American Chemical Society · doi:10.1021/ja809721j · Cited by 285 · cited 4×
“Recently, investigators have developed hybrid bioconjugates, which link FPs to QDs via biotin-streptavidin interactions or poly-histidine peptide tags, thus enabling FRET interactions (Dennis and Bao 2008; Lu et al. 2008; Boeneman et al. 2009; Medintz et al. 2009).”
BackgroundMethodInfluentialGold nanoparticles-based protease assay
Guarise, C., Pasquato, L., De Filippis, V., & Scrimin, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509372103 · Cited by 284 · cited 2×
“For instance, aggregation of AuNPs through crosslinking was induced by dithiol-containing substrate in the absence of enzyme activity, whereas presence of protease thrombin inhibited aggregation (Guarise et al. 2006).”
BackgroundMethodWang, Z., Lévy, R., Fernig, D. G., & Brust, M. (2006) · Journal of the American Chemical Society · doi:10.1021/ja058135y · Cited by 276 · cited 1×
“Their aggregation determines color change of the assay solution (Guarise et al. 2006; Z. X. Wang et al. 2006).”
MethodQuantum Dot/Bioluminescence Resonance Energy Transfer Based Highly Sensitive Detection of Proteases
Yao, H., Zhang, Y., Xiao, F., Xia, Z., & Rao, J. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700280 · Cited by 275 · cited 3×
“As MMPs cleaved the specific substrate, the BRET signal was suppressed (Figure 3) (Yao et al. 2007).”
BackgroundCastillo, J., Gáspár, S., Leth, S., Niculescu, M., Mortari, A., Bontidean, I., Soukharev, V., Dorneanu, S. A., Ryabov, A. D., & Csöregi, E. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.04.084 · Cited by 272 · cited 1×
“Concurrent detection and quantification can occur without prior separation or derivatization (Castillo et al. 2004).”
BackgroundAmperometric Detection of Dopamine in Vivo with an Enzyme Based Carbon Fiber Microbiosensor
Njagi, J., Chernov, M. M., Leiter, J. C., & Andreescu, S. (2010) · Analytical Chemistry · doi:10.1021/ac9022605 · Cited by 264
Self-citationWu, P., Shao, Q., Hu, Y., Jin, J., Yin, Y., Zhang, H., & Cai, C. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.07.079 · Cited by 254 · cited 2×
“A relatively new material in the biosensing arena is graphene, a form of carbon with remarkable electrical properties, high surface area, excellent conductivity, and mechanical strength (Shan, Yang et al. 2009; Shao et al. 2010; Wu et al. 2010).”
BackgroundThread as a Matrix for Biomedical Assays
Reches, M., Mirica, K. A., Dasgupta, R., Dickey, M. D., Butte, M. J., & Whitesides, G. M. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am1002266 · Cited by 250
Quantum Dot/Bioluminescence Resonance Energy Transfer Based Highly Sensitive Detection of Proteases
Yao, H., Zhang, Y., Xiao, F., Xia, Z., & Rao, J. (2007) · Angewandte Chemie · doi:10.1002/ange.200700280 · Cited by 249
Potential clinical applications of quantum dots
Clapp, A. (2008) · International Journal of Nanomedicine · doi:10.2147/ijn.s614 · Cited by 233
Molecular Electronic Devices Based on Single-Walled Carbon Nanotube Electrodes
Feldman, A. K., Steigerwald, M. L., Guo, X., & Nuckolls, C. P. (2008) · Accounts of Chemical Research · doi:10.1021/ar8000266 · Cited by 227 · cited 1×
“Molecular electronic devices have been developed as inexpensive low power systems (Feldman et al. 2008; Roberts et al. 2009) for medical care (Macaya et al.”
Fluorescent-conjugated polymer superquenching facilitates highly sensitive detection of proteases
Kumaraswamy, S., Bergstedt, T., Shi, X., Rininsland, F., Kushon, S., Xia, W., Ley, K., Achyuthan, K., McBranch, D., & Whitten, D. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402367101 · Cited by 216 · cited 2×
“Fluorescence quenching of the fully integrated sensor was reversed in presence of different enzymes for instance b-secretase, an important target enzyme for Alzeimer disease therapeutics (Kumaraswamy et al. 2004).”
BackgroundMethodProtease-activated quantum dot probes
Chang, E., Miller, J. S., Sun, J., Yu, W. W., Colvin, V. L., Drezek, R., & West, J. L. (2005) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2005.07.028 · Cited by 214 · cited 2×
“Chang et al. (2005) developed optically-quenched QDs tethered to gold nanoparticles by specific peptide sequence.”
BackgroundQuantitative analysis of gene expression with an improved green fluorescent protein
Scholz, O., Thiel, A., Hillen, W., & Niederweis, M. (2000) · European Journal of Biochemistry · doi:10.1046/j.1432-1327.2000.01170.x · Cited by 201
Susumu, K., Mei, B. C., & Mattoussi, H. (2009) · Nature Protocols · doi:10.1038/nprot.2008.247 · Cited by 201 · cited 2×
“2001), dihydrolipoic acid (Susumu et al. 2009), phospines (Kim and Bawendi 2003), dendrons (Y.”
BackgroundMaterial and device considerations for organic thin-film transistor sensors
Roberts, M. E., Sokolov, A. N., & Bao, Z. (2009) · Journal of Materials Chemistry · doi:10.1039/b816386c · Cited by 198 · cited 2×
“Molecular electronic devices have been developed as inexpensive low power systems (Feldman et al. 2008; Roberts et al. 2009) for medical care (Macaya et al.”
BackgroundYuan, J., Guo, W., & Wang, E. (2008) · Analytical Chemistry · doi:10.1021/ac0713048 · Cited by 196 · cited 1×
“The CdTe QDs quenching by electron transfer was also used to quantitatively detect levels of toxic phenolic compounds, in the presence of H2O2 and horseradish peroxidase (Yuan et al. 2008).”
MethodProtease sensors for bioimaging
Funovics, M., Weissleder, R., & Tung, C.-H. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2199-0 · Cited by 186 · cited 2×
“Early and in situ detection of tumors requires availability of biocompatible delivery vehicles of fluorescent probes to ensure tumor delivery and tissue uptake, as well as probes that are capable of producing bright fluorescence upon specific cleavage of elevated proteases (Weissleder et al. 1999; Funovics et al. 2003…”
BackgroundQuantum Dot−Fluorescent Protein Pairs as Novel Fluorescence Resonance Energy Transfer Probes
Dennis, A. M., & Bao, G. (2008) · Nano Letters · doi:10.1021/nl080358+ · Cited by 184 · cited 2×
“Recently, investigators have developed hybrid bioconjugates, which link FPs to QDs via biotin-streptavidin interactions or poly-histidine peptide tags, thus enabling FRET interactions (Dennis and Bao 2008; Lu et al. 2008; Boeneman et al. 2009; Medintz et al. 2009).”
BackgroundIn-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178 · cited 1×
“…including optical (Borisov and Wolfbeis 2008) and electrochemical sensors (J. Wang 2008; Ronkainen et al. 2010) for in vivo detection (Wilson and Hu 2000; Wilson and Johnson 2008) and diabetes management (Heller and Feldman 2008; J. Wang 2008) have been discussed in several excellent reviews.”
BackgroundZhao, W., Chiuman, W., Lam, J. C. F., Brook, M. A., & Li, Y. (2007) · Chemical Communications · doi:10.1039/b705335e · Cited by 178 · cited 1×
“Aggregation by non-crosslinking was proposed by W. A. Zhao et al. (2007) where a colorimetric change was observed when alkaline phosphatase induced dephosphorylation of ATP capped AuNPs and further their aggregation.”
BackgroundIntracellular Delivery of Quantum Dot−Protein Cargos Mediated by Cell Penetrating Peptides
Medintz, I. L., Pons, T., Delehanty, J. B., Susumu, K., Brunel, F. M., Dawson, P. E., & Mattoussi, H. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800089r · Cited by 167
Schuhmann, W. (2002) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00058-7 · Cited by 166 · cited 1×
“This electron transfer process results in generation of current that is proportional with the concentration of analyte (Schuhmann 2002).”
BackgroundWang, X.-S., Dykstra, T. E., Salvador, M. R., Manners, I., Scholes, G. D., & Winnik, M. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0489339 · Cited by 164
Simple glucose sensors with micromolar sensitivity based on organic electrochemical transistors
Macaya, D. J., Nikolou, M., Takamatsu, S., Mabeck, J. T., Owens, R. M., & Malliaras, G. G. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.038 · Cited by 161 · cited 1×
“Molecular electronic devices have been developed as inexpensive low power systems (Feldman et al. 2008; Roberts et al. 2009) for medical care (Macaya et al. 2007).”
BackgroundZhang, Q., Qiao, Y., Hao, F., Zhang, L., Wu, S., Li, Y., Li, J., & Song, X. (2010) · Chemistry - A European Journal · doi:10.1002/chem.201000684 · Cited by 160 · cited 2×
“…in the field of electrochemical enzyme biosensors involve the use of novel electrode materials and immobilization strategies to ensure more efficient and stable attachment of the enzyme, provide biocompatibility and enhance surface area and electrochemical signals (Q. A. Zhang et al. 2010).”
BackgroundMahajan, N. P., Harrison-Shostak, D. C., Michaux, J., & Herman, B. (1999) · Chemistry & Biology · doi:10.1016/s1074-5521(99)80051-9 · Cited by 145 · cited 2×
“Mahajan et al. (1999) reported in vitro detection of caspase-1 and caspase-30s activity using specific tetrapeptide sequence substrates between blue FP (BFP) and GFP such that FRET was disrupted when purified substrates were exposed to purified enzymes.”
BackgroundMethodNikkola, J., Vihinen, P., Vlaykova, T. I., Hahka‐Kemppinen, M., Kähäri, V., & Pyrhönen, S. O. (2001) · International Journal of Cancer · doi:10.1002/ijc.1636 · Cited by 144 · cited 1×
“MMPs are responsible for many pathological conditions by accelerating degradation of extracellular matrix, which is conducive to cancer metastasis, osteoarthritis, periodontosis, rheumatoid arthritis, etc. (Nikkola et al. 2002; Uchima et al. 2007).”
BackgroundLu, H., Schöps, O., Woggon, U., & Niemeyer, C. M. (2008) · Journal of the American Chemical Society · doi:10.1021/ja078243f · Cited by 130 · cited 1×
“Recently, investigators have developed hybrid bioconjugates, which link FPs to QDs via biotin-streptavidin interactions or poly-histidine peptide tags, thus enabling FRET interactions (Dennis and Bao 2008; Lu et al. 2008; Boeneman et al. 2009; Medintz et al. 2009).”
BackgroundLuckham, R. E., & Brennan, J. D. (2010) · The Analyst · doi:10.1039/c0an00283f · Cited by 121
Resonance Energy Transfer Between Luminescent Quantum Dots and Diverse Fluorescent Protein Acceptors
Medintz, I. L., Pons, T., Susumu, K., Boeneman, K., Dennis, A. M., Farrell, D. F., Deschamps, J. R., Melinger, J. S., Bao, G., & Mattoussi, H. M. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp9060329 · Cited by 119 · cited 2×
“Recently, investigators have developed hybrid bioconjugates, which link FPs to QDs via biotin-streptavidin interactions or poly-histidine peptide tags, thus enabling FRET interactions (Dennis and Bao 2008; Lu et al. 2008; Boeneman et al. 2009; Medintz et al. 2009).”
BackgroundImaging Calpain Protease Activity by Multiphoton FRET in Living Mice
Stockholm, D., Bartoli, M., Sillon, G., Bourg, N., Davoust, J. M., & Richard, I. (2004) · Journal of Molecular Biology · doi:10.1016/j.jmb.2004.11.039 · Cited by 118 · cited 1×
“Many reports employed FRET between donor and acceptor flanking a substrate to monitor proteases activity (Chang et al. 2005; Stockholm et al. 2005).”
BackgroundElimination of electrochemical interferences in glucose biosensors
Jia, W., Wang, K., & Xia, X. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.01.006 · Cited by 114 · cited 1×
“A key challenge is to remove interferences and provide sufficient selectivity in physiological conditions (Jia et al. 2010).”
BackgroundA Novel Method for Imaging Apoptosis Using a Caspase-1 Near-Infrared Fluorescent Probe
Messerli, S. M., Prabhakar, S., Tang, Y., Shah, K., Cortes, M. L., Murthy, V., Weissleder, R., Breakefield, X. O., & Tung, C.-H. (2004) · Neoplasia · doi:10.1593/neo.03214 · Cited by 113
PEGylated and MMP-2 Specifically DePEGylated Quantum Dots: Comparative Evaluation of Cellular Uptake
Mok, H., Bae, K. H., Ahn, C., & Park, T. G. (2008) · Langmuir · doi:10.1021/la803542v · Cited by 100 · cited 3×
“There is a large interest in developing bioanalytical sensors for detection of matrix metalloproteinase (MMP) activity (Yao et al. 2007; Mok et al. 2009).”
BackgroundChallenges in the use of 1D nanostructures for on-chip biosensing and diagnostics: A review
Balasubramanian, K. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.041 · Cited by 99 · cited 2×
“, silicon, zinc oxide and indium oxide) and nanochannels have been investigated for detection of different biomolecules and integrated on a chip (Balasubramanian 2010).”
Backgroundl-lactate measures in brain tissue with ceramic-based multisite microelectrodes
Burmeister, J. J., Palmer, M. R., & Gerhardt, G. A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.003 · Cited by 93
Are bacterial proteases important virulence factors?
Lantz, M. S. (1997) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1997.tb01393.x · Cited by 91
Optical nanoparticle sensors for quantitative intracellular imaging
Lee, Y.-E. K., & Kopelman, R. (2008) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.2 · Cited by 87
Single fiber-optic fluorescence enzyme-based sensor
Fuh, M. R. S., Burgess, L. W., & Christian, G. D. (1988) · Analytical Chemistry · doi:10.1021/ac00156a012 · Cited by 82
Mixed Ceria-Based Metal Oxides Biosensor for Operation in Oxygen Restrictive Environments
Njagi, J. I., Ispas, C., & Andreescu, S. (2008) · Analytical Chemistry · doi:10.1021/ac800808a · Cited by 78
Self-citationWang, J., Wang, L., Di, J., & Tu, Y. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.08.023 · Cited by 74 · cited 1×
“Modern enzyme biosensors are incorporating carbon nanotubes, gold or silver nanoparticles alone or in composite form with conductive polymers and electron mediators in the sensing layer (J. W. Wang et al. 2008).”
BackgroundSingle cells as experimentation units in lab-on-a-chip devices
Gac, S. L., & van den Berg, A. (2009) · Trends in biotechnology · doi:10.1016/j.tibtech.2009.10.005 · Cited by 71
Electrochemical Studies of Ceria as Electrode Material for Sensing and Biosensing Applications
Ispas, C., Njagi, J. I., Cates, M., & Andreescu, S. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2936178 · Cited by 62 · cited 1×
“We proposed a robust and sensitive glucose biosensor with the glucose oxidase enzyme immobilized into a biocompatible matrix of ceria nanoparticles and chitosan (Ispas et al. 2008).”
MethodSelf-citationThe extrinsic apoptosis pathway and its prognostic impact in ovarian cancer
Duiker, E. W., van der Zee, A. G. J., de Graeff, P., Ek, W. B., Hollema, H., de Bock, G. H., de Jong, S., & de Vries, E. G. E. (2009) · Gynecologic Oncology · doi:10.1016/j.ygyno.2009.09.014 · Cited by 55 · cited 1×
“Their activity is inhibited in various tumors to ensure cancer cell survival and they are often used as a prognostic indicator in ovarian cancer (Legge et al. 2005; Duiker et al. 2010).”
BackgroundNjagi, J. I., Erlichman, J. S., Aston, J. W., Leiter, J. C., & Andreescu, S. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.10.029 · Cited by 36
Self-citationShi, H., Xia, T., Nel, A. E., & Yeh, J. I. (2007) · Nanomedicine · doi:10.2217/17435889.2.5.599 · Cited by 31 · cited 1×
“The use of nanoscale electrodes and nanobiosensors and their potential in medical diagnosis have been reviewed by H. Shi et al. (2007) and H. Shi and Yeh (2007).”
MethodBiological characterization of ovarian cancer: prognostic and therapeutic implications
Legge, F., Ferrandina, G., Salutari, V., & Scambia, G. (2005) · Annals of Oncology · doi:10.1093/annonc/mdi916 · Cited by 30
The genetic and molecular bases of monogenic disorders affecting proteolytic systems
Richard, I. (2005) · Journal of Medical Genetics · doi:10.1136/jmg.2004.028118 · Cited by 24
Part I: Recent Developments in Nanoelectrodes for Biological Measurements
Shi, H., & Yeh, J. I. (2007) · Nanomedicine · doi:10.2217/17435889.2.5.587 · Cited by 24
Cited by
Metal–Organic Framework-Based Enzyme Biocomposites
Liang, W., Wied, P., Carraro, F., Sumby, C. J., Nidetzky, B., Tsung, C.-K., Falcaro, P., & Doonan, C. J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01029 · Cited by 784
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Yu, H., Alkhamis, O., Canoura, J., Liu, Y., & Xiao, Y. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202008663 · Cited by 492
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
“Regulation changes of the enzymes’ selective conformation serve as a biorecognition method in biosensors [18].”
MethodRecent Advances in Optical Biosensors for Environmental Monitoring and Early Warning
Long, F., Zhu, A., & Shi, H. (2013) · Sensors · doi:10.3390/s131013928 · Cited by 345
Metadata
- Authors
- Ispas, C. R., Crivat, G., & Andreescu, S.
- Venue
- Analytical Letters
- Publisher
- Informa UK Limited
- Published
- 2012-01
- Volume
- 45
- Issue
- 2-3
- Pages
- 168-186
- ISSN
- 0003-2719 (ISSN-L)
- 1532-236X
- OpenAlex
- W2066047067
- Cited by
- 191
- References
- 91
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.