Pre-analytical phase management: a review of the procedures from patient preparation to laboratory analysis
The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
The pre-analytical phase encompasses all the procedures before the start of laboratory testing. This phase of the testing process is responsible for the majority of the laboratory errors, since the related procedures involve many sorts of non-laboratory professionals working outside the laboratory setting, thus without direct supervision by the laboratory staff. Therefore, either correct organization or management of both personnel and procedures that regard blood specimen collection by venipuncture are of fundamental importance, since the various steps for performing blood collection represent per se sources of laboratory variability. The aim of this (non-systematic) review addressed to healthcare professionals is to highlight the importance of blood specimen management (from patient preparation to laboratory analyses), as a tool to prevent laboratory errors, with the concept that laboratory results from inappropriate blood specimens are inconsistent and do not allow proper treatment nor monitoring of the patient.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There are other potential factors such as regular or/and recent physical activity, food intake and intake of drugs, over-the-counter medicines, food supplements and herbal preparations, etc. which are known to affect the concentration of certain analytes and it should be verified whether the patient has followed necessary instructions before blood sampling [23], [24], [25].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [23]
In the citing paper
“Education increases the level of confidence and improves quality of procedures [110].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [110]
Citations
Cites
Diagnostic error in internal medicine
Graber, M. L., Franklin, N., & Gordon, R. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.13.1493 · Cited by 1,549
Effects of Drugs on Clinical Laboratory Tests
Young, D. S., Thomas, D. W., Friedman, R. B., & Pestaner, L. C. (1972) · Clinical Chemistry · doi:10.1093/clinchem/18.10.1041 · Cited by 646
Diagnostic Error in Medicine: Analysis of 583 Physician-Reported Errors
Schiff, G. D. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.333 · Cited by 638 · cited 2×
“It is already known that 40% of the diagnostic errors are linked with results from diagnostic services such as imaging (radiology) or laboratory [4,8].”
BackgroundWhy is the laboratory an afterthought for managed care organizations?
Forsman, R. W. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.5.813 · Cited by 387
Interferences from blood collection tube components on clinical chemistry assays
Bowen, R. A. R., & Remaley, A. T. (2014) · Biochemia Medica · doi:10.11613/bm.2014.006 · Cited by 316
Banfi, G., Salvagno, G. L., & Lippi, G. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.110 · Cited by 297
Self-citationActing on Significant Laboratory Results
Lundberg, G. D. (1981) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1981.03310420052033 · Cited by 229
Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories
Lippi, G., Plebani, M., Di Somma, S., & Cervellin, G. (2011) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2011.600228 · Cited by 226
Self-citationThe ‘70% claim’: what is the evidence base?
Hallworth, M. J. (2011) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2011.011177 · Cited by 172
Standardization of collection requirements for fasting samples
Simundic, A. M., Cornes, M., Grankvist, K., Lippi, G., & Nybo, M. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.11.008 · Cited by 156 · cited 2×
“Patient preparation: fasting time should be mandatory [11,15], and physical activities avoided [16] for the mainstream laboratory tests; 2.”
BackgroundSelf-citationIdentification errors in pathology and laboratory medicine
Valenstein, P. N., & Sirota, R. L. (2004) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2004.05.013 · Cited by 132
Pseudohyperkalemia Caused by Fist Clenching during Phlebotomy
Don, B. R., Sebastian, A., Cheitlin, M., Christiansen, M., & Schambelan, M. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005033221806 · Cited by 132 · cited 1×
“The suggestion sometimes made by some phlebotomists to repeated fist clenching before venipuncture is another kind of disturbance of blood collection [56].”
BackgroundCalfee, D. P., & Farr, B. M. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.5.1660-1665.2002 · Cited by 104
Dugan, L., Leech, L., Speroni, K., & Corriher, J. (2005) · Journal of Emergency Nursing · doi:10.1016/j.jen.2005.05.004 · Cited by 103
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C. (2015) · Journal of Medical Biochemistry · doi:10.2478/jomb-2014-0043 · Cited by 102 · cited 3×
“Briefly, main fasting time for the majority of blood tests should be 12 h; any exercise shall be avoided 72 h before blood sampling; moreover, information about therapeutic-drug intake should be made available to laboratory personnel [10,11].”
BackgroundSelf-citationNikolac, N., Šupak Smolčić, V., Šimundić, A.-M., & Ćelap, I. (2013) · Biochemia Medica · doi:10.11613/bm.2013.031 · Cited by 99 · cited 2×
“Although the labelling of primary tubes before- or after-venipuncture is currently seen as an unresolved issue [77], there is no reliable evidence to support a specific recommendation that samples should be labeled prior to blood collection; however, samples shall be labeled in the presence of the patient (otherwise,…”
BackgroundEffects of Drugs on Clinical Laboratory Tests
Kahn, S. E. (2001) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2001-125-844a-eodocl · Cited by 97
Simundic, A.-M., Church, S., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Nikolac, N., van Dongen-Lases, E., Eker, P., Kovalevskaya, S., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1053 · Cited by 95
Self-citationFernandes, C. M. B., Worster, A., Eva, K. W., Hill, S., & McCallum, C. (2006) · Journal of Emergency Nursing · doi:10.1016/j.jen.2005.11.013 · Cited by 94
Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0426 · Cited by 92 · cited 3×
“Interestingly, a recent EFLM survey carried out in 12 European countries reported that compliance of phlebotomy procedures with the CLSI H3A6 guidelines was unacceptably low, thus confirming that both the patient identification and tube labeling still represents a critical issue for preanalytical quality management [7…”
MethodSelf-citationHemolysis detection and management of hemolysed specimens
Simundic, A.-M., Topic, E., Nikolac, N., & Lippi, G. (2010) · Biochemia Medica · doi:10.11613/bm.2010.018 · Cited by 89
Self-citationInfluence of short-term venous stasis on clinical chemistry testing
Lippi, G., Salvagno, G. L., Montagnana, M., Brocco, G., & Guidi, G. C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.146 · Cited by 81
Self-citationLaboratory Automation: Total and Subtotal
Hawker, C. D. (2007) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2007.07.010 · Cited by 78
The “hospital central laboratory”: automation, integration and clinical usefulness
Zaninotto, M., & Plebani, M. (2010) · cclm · doi:10.1515/cclm.2010.192 · Cited by 77
Suitability of a transport box for blood sample shipment over a long period
Lippi, G., Lima-Oliveira, G., Nazer, S. C., Moreira, M. L. L., Souza, R. F. M., Salvagno, G. L., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2011.05.028 · Cited by 76
Self-citationWallin, O., Söderberg, J., Guelpen, B. R. V., Stenlund, H. C., Grankvist, K., & Brulin, C. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.02.016 · Cited by 74
Influence of a light meal on routine haematological tests.
(2010) · PubMed Central · doi:10.2450/2009.0142-09 · Cited by 71
Self-citationSárközi, L., Simson, E., & Ramanathan, L. V. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00020-2 · Cited by 70
Yamada, K., Yamada, K., Katsuda, I., & Hida, T. (2008) · Clinical Anatomy · doi:10.1002/ca.20622 · Cited by 70
Guss, D. A., Chan, T. C., & Killeen, J. P. (2008) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.03.010 · Cited by 69
Wallin, O., Söderberg, J., Grankvist, K., Jonsson, P. A., & Hultdin, J. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.288 · Cited by 68
Short-term venous stasis influences routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000178828.59866.03 · Cited by 66
Self-citationSharratt, C. L., Gilbert, C. J., Cornes, M. C., Ford, C., & Gama, R. (2009) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2008.01981.x · Cited by 66 · cited 2×
“Indeed, the assessment of EDTA in serum or plasma is inexpensive and can be easily implemented in the vast majority of automated analyzers for routine biochemical measurements [69].”
BackgroundLima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66 · cited 1×
“procedure described in CLSI H03-A6 standard [53].”
Self-citationPhysical activity - an important preanalytical variable
Sanchis-Gomar, F., & Lippi, G. (2014) · Biochemia Medica · doi:10.11613/bm.2014.009 · Cited by 65
Self-citationSöderberg, J., Brulin, C., Grankvist, K., & Wallin, O. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.048 · Cited by 64
Influence of a regular, standardized meal on clinical chemistry analytes
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Gelati, M., Montagnana, M., Danese, E., Picheth, G., & Guidi, G. C. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2012.32.4.250 · Cited by 63
Self-citationLippi, G., Cornes, M. P., Grankvist, K., Nybo, M., & Simundic, A.-M. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1274 · Cited by 59
Self-citationLippi, G., Salvagno, G. L., Lima-Oliveira, G., Brocco, G., Danese, E., & Guidi, G. C. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.11.024 · Cited by 57 · cited 2×
“Patient posture: patient should be kept in a standardized posture for 15–20min in order to reduce laboratory variability [32,34]; however, this might impact on the workflow of blood collection sites, but can be eased by scheduling blood collections; 4.”
BackgroundSelf-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Pitanguiera Manguera, C. L., Sumita, N. M., Picheth, G., Guidi, G. C., & Scartezini, M. (2011) · Biochemia Medica · doi:10.11613/bm.2011.024 · Cited by 56
Self-citationLippi, G., Salvagno, G. L., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.172 · Cited by 56
Self-citationVenous stasis and routine hematologic testing
LIPPI, G., SALVAGNO, G. L., MONTAGNANA, M., FRANCHINI, M., & GUIDI, G. C. (2006) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2006.00818.x · Cited by 53
Self-citationKeshgegian, A. A., & Bull, G. E. (1992) · American Journal of Clinical Pathology · doi:10.1093/ajcp/97.4.535 · Cited by 51
Hawker, C. D., Roberts, W. L., Garr, S. B., Hamilton, L. T., Penrose, J. R., Ashwood, E. R., & Weiss, R. L. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.10.1761 · Cited by 49
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.03.007 · Cited by 47
Self-citationRecommended "order of draw" for collecting blood specimens into additive-containing tubes.
Calam, R. R., & Cooper, M. H. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.6.1399 · Cited by 47
LIMA‐OLIVEIRA, G., LIPPI, G., SALVAGNO, G. L., MONTAGNANA, M., SCARTEZINI, M., GUIDI, G. C., & PICHETH, G. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01305.x · Cited by 46 · cited 1×
“Impact of physiology disturbance on vein caused by two different source of variability (vein stasis by tourniquet application and cold with vibration by BuzzyR ) on routine haematological testing [48,55].”
BackgroundSelf-citationPosture and the composition of plasma.
Dixon, M., & Paterson, C. R. (1978) · Clinical Chemistry · doi:10.1093/clinchem/24.5.824 · Cited by 42
Lippi, G., Salvagno, G. L., Danese, E., Lima-Oliveira, G., Brocco, G., & Guidi, G. C. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.05.028 · Cited by 42
Self-citationThe order of draw: myth or science?
Salvagno, G., Lima-Oliveira, G., Brocco, G., Danese, E., Guidi, G. C., & Lippi, G. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0412 · Cited by 42
Self-citationTransillumination Mapping Prior To Ambulatory Phlebectomy
WEISS, R. A., & GOLDMAN, M. P. (1998) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1998.tb04186.x · Cited by 41
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.037 · Cited by 40
Self-citationPreanalytical management: serum vacuum tubes validation for routine clinical chemistry
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.021 · Cited by 39
Self-citationElimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
Self-citationColour coding for blood collection tube closures – a call for harmonisation
Šimundić, A.-M., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Ceriotti, F., Theodorsson, E., & Panteghini, M. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0927 · Cited by 36
Self-citationTo mix or not to mix venous blood samples collected in vacuum tubes?
Parenmark, A., & Landberg, E. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.705 · Cited by 33 · cited 2×
“Although either vigorous or gentle tube mixing immediately after blood collection have similar effects on laboratory results for clinical chemistry, hematology, and coagulation analyses [73], avoidance of mixing primary evacuated tubes does not carry a substantial risk of clotting [71,72].”
BackgroundLima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e32835b72ea · Cited by 33
Self-citationEffects of vigorous mixing of blood vacuum tubes on laboratory test results
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Gelati, M., Volanski, W., Boritiza, K. C., Picheth, G., & Guidi, G. C. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.10.033 · Cited by 33
Self-citationDevelopment of Standards for Laboratory Automation
Hawker, C. D., & Schlank, M. R. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.5.746 · Cited by 33
Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33 · cited 1×
“In contrast to these findings, inaccurate results of both serum potassium and calcium were reported with a dedicated-syringe for blood gas analyses, contaminated by EDTA from a previous evacuated tube [68].”
ResultSelf-citationLima-Oliveira, G., Guidi, G. C., Salvagno, G. L., Brocco, G., Danese, E., & Lippi, G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.07.007 · Cited by 33
Self-citationTo avoid fasting time, more risk than benefits
Guidi, G. C., Šimundić, A.-M., Salvagno, G. L., Aquino, J. L., & Lima-Oliveira, G. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1013 · Cited by 32
Self-citationHawker, C. D., Garr, S. B., Hamilton, L. T., Penrose, J. R., Ashwood, E. R., & Weiss, R. L. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.10.1751 · Cited by 32
Lima-Oliveira, G., Salvagno, G. L., Danese, E., Favaloro, E. J., Guidi, G. C., & Lippi, G. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12301 · Cited by 30
Self-citationCould light meal jeopardize laboratory coagulation tests?
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Danese, E., Gelati, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2014) · Biochemia Medica · doi:10.11613/bm.2014.036 · Cited by 30
Self-citationEffects of contamination of blood specimens with liquid potassium-EDTA anticoagulant
Davidson, D. F. (2002) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563021901973 · Cited by 30
Multi-centre observational study of spurious hyperkalaemia due to EDTA contamination.
Cornes, M. P., Davidson, F., Darwin, L., Gay, C., Redpath, M., Waldron, J. L., Ford, C., & Gama, R. M. (2010) · PubMed · Cited by 29
Is Phlebotomy Part of the Dark Side in the Clinical Laboratory Struggle for Quality?
Lima-Oliveira, G., Guidi, G. C., Salvagno, G. L., Montagnana, M., Rego, F. G. M., Lippi, G., & Picheth, G. (2012) · Laboratory Medicine · doi:10.1309/lmz7yard6zsdiid · Cited by 28
Self-citationInfluence of posture on routine hemostasis testing
Lippi, G., Salvagno, G. L., Lima-Oliveira, G., Danese, E., Favaloro, E. J., & Guidi, G. C. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000326 · Cited by 27 · cited 1×
“Patient posture: patient should be kept in a standardized posture for 15–20min in order to reduce laboratory variability [32,34]; however, this might impact on the workflow of blood collection sites, but can be eased by scheduling blood collections; 4.”
BackgroundSelf-citationTatsumi, N., Okuda, K., & Tsuda, I. (1999) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00179-5 · Cited by 26
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Poli, G., Solero, G. P., Picheth, G., & Guidi, G. C. (2013) · British Journal of Biomedical Science · doi:10.1080/09674845.2013.11669922 · Cited by 23
Self-citationIncorrect order of draw of blood samples does not cause potassium EDTA sample contamination
Cornes, M. P., Sulaiman, R. A., Whitehead, S. J., Othonos, N., Ford, C., & Gama, R. M. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12069141 · Cited by 22
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Brocco, G., Gaino, S., Dima, F., Volaski, W., Rego, F. G., Picheth, G., & Guidi, G. C. (2014) · Biopreservation and Biobanking · doi:10.1089/bio.2013.0043 · Cited by 22
Self-citationLima-Oliveira, G., Salvagno, G. L., Danese, E., Brocco, G., Guidi, G. C., & Lippi, G. (2014) · Biochemia Medica · doi:10.11613/bm.2014.038 · Cited by 21
Self-citationK3EDTA Vacuum Tubes Validation for Routine Hematological Testing
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Poli, G., Solero, G. P., Picheth, G., & Guidi, G. C. (2012) · ISRN Hematology · doi:10.5402/2012/875357 · Cited by 21
Self-citationErnst, D. J., & Ernst, C. T. (2002) · Home Healthcare Now · doi:10.1097/00004045-200203000-00005 · Cited by 20
Avoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis
Salvagno, G. L., Danese, E., Lima-Oliveira, G., Guidi, G. C., & Lippi, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.023 · Cited by 20 · cited 2×
“Cleansing and selection of the venipuncture site: avoidance of drying disinfectant at venipuncture site does not damage erythrocytes [40], whereas basilica vein should be avoided to reduce hemolysis rates [43]; 5.”
BackgroundSelf-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Dima, F., Brocco, G., Picheth, G., & Guidi, G. C. (2013) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12143 · Cited by 19
Self-citationDeviations from venous blood specimen collection guideline adherence among senior nursing students
Nilsson, K., Grankvist, K., Juthberg, C., Brulin, C., & Söderberg, J. (2013) · Nurse Education Today · doi:10.1016/j.nedt.2013.06.018 · Cited by 15
Blood Collection From Intravenous Lines: Is One Drawing Site Better Than Others?
Lippi, G., Avanzini, P., Aloe, R., & Cervellin, G. (2014) · Laboratory Medicine · doi:10.1309/lm2xcv5sqml1ontm · Cited by 15
Self-citationDoes Laboratory Automation for the Preanalytical Phase Improve Data Quality?
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Danese, E., Montagnana, M., Brocco, G., Voi, M., Picheth, G., & Guidi, G. C. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068213488892 · Cited by 15
Self-citationA new device to relieve venipuncture pain can affect haematology test results.
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Campelo, M. D., Tajra, K. S. A., Gomes, F. D. S., Valentim, C. D., Romano, S. J. C., Picheth, G., & Guidi, G. C. (2014) · Europe PMC (PubMed Central) · doi:10.2450/2013.0002-13 · Cited by 14
Self-citationThe impact of fist clenching and its maintenance during venipuncture on routine hematology testing
Lima-Oliveira, G., Guidi, G. C., Salvagno, G. L., & Lippi, G. (2016) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22108 · Cited by 12
Self-citationLima-Oliveira, G., Salvagno, G. L., Lippi, G., Brocco, G., Voi, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Accreditation and Quality Assurance · doi:10.1007/s00769-013-0995-6 · Cited by 11
Self-citationSpecimen labelling: before or after collection?
Hawkins, R. C. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.737 · Cited by 11
Baxter, A. L., & Lawson, M. L. (2014) · Europe PMC (PubMed Central) · doi:10.2450/2013.0244-13 · Cited by 7
Development and Validation of an Automated Thawing and Mixing Workcell
Hawker, C. D., Roberts, W. L., Dasilva, A., Stam, G. D., Owen, W. E., Curtis, D., Choi, B.-S., & Ring, T. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.094185 · Cited by 7
Circulating cardiac troponin T is not influenced by postural changes during venous blood collection
Lippi, G., Salvagno, G. L., Lima-Oliveira, G., Montagnana, M., Danese, E., & Guidi, G. C. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.10.018 · Cited by 6
Self-citationDoes fist pumping/clenching during venipuncture activate blood coagulation?
Lippi, G., Lima-Oliveira, G., & Guidi, G. C. (2016) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000429 · Cited by 6
Self-citationBiochemical characterisation of urease from urease-positive thermophilic Campylobacter (UPTC)
Tazumi, A., Nakajima, T., Sekizuka, A., Arikawa, K., Nakanishi, N., Hayashi, H., Tasaki, T., Moore, J. E., Millar, B. C., & Matsuda, M. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.11669913 · Cited by 4
Lima-Oliveira, G. (2014) · Journal of Medical Diagnostic Methods · doi:10.4172/2168-9784.1000e111 · Cited by 2
Self-citationStandardizing Patient’s Posture During Blood Collection by Venipuncture
Lima-Oliveira, G. (2016) · Avicenna Journal of Medical Biochemistry · doi:10.17795/ajmb-33936 · Cited by 2
Self-citationBlood collection systems in clinical laboratories: Local adaptation of the EFLM guidelines
Giavarina, D., Banfi, G., Daves, M., Dolci, A., Santarcangeli, D. F., Lima-Oliveira, G., Miconi, V., Milanesi, B., Montagnana, M., Morandini, M., et al. (2016) · Archivio Istituzionale della Ricerca - Università Vita-Salute San Raffaele · doi:10.19186/bc_2016.032 · Cited by 2
Self-citation
Research works printed but not linked: 10
- Clinical Laboratory Standards Institute, 2013, Quality management system: development and management of laboratory documents. CLSI QMSo2-A6 document
- Lippi G, 2010, Blood Transfus, 8, 94
- International Organization for Standardization (ISO)., 2001, Stainless steel needle tubing for manufacture of medical devices. Amendment 1. ISO 9626 document
- International Organization for Standardization (ISO), 2012, Medical laboratories: requirements for quality and competence ISO document 15189
- Clinical Laboratory Standards Institute, 2007, Procedures for the collection of diagnostic blood specimens by venipuncture. CLSI H3-A6 document
- World Health Organization (WHO), 2010, WHO guidelines on drawing blood: best practices in phlebotomy
- Baxter A, 2014, Blood Transfus, 12, S3
- Lima-Oliveira G, 2014, Blood Transfus, 12, s6
- Cornes MP, 2010, Clin Lab, 56, 597
- Giavarina D, 2016, Biochimica Clinica, 40, 347
Cited by
Burla, B., Arita, M., Arita, M., Bendt, A. K., Cazenave-Gassiot, A., Dennis, E. A., Ekroos, K., Han, X., Ikeda, K., Liebisch, G., et al. (2018) · Journal of Lipid Research · doi:10.1194/jlr.s087163 · Cited by 312
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationCauses, consequences and management of sample hemolysis in the clinical laboratory
Heireman, L., Geel, P. V., Musger, L., Heylen, E., Uyttenbroeck, W., & Mahieu, B. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.09.013 · Cited by 174
Impact of intermittent fasting on the lipid profile: Assessment associated with diet and weight loss
Santos, H. O., & Macedo, R. C. O. (2018) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2018.01.002 · Cited by 173
Hypogonadism in Exercising Males: Dysfunction or Adaptive-Regulatory Adjustment?
Hackney, A. C. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00011 · Cited by 118
Metadata
- Authors
- Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C.
- Affiliations
- University of Verona (IT)
- Universidade Federal do Paraná (BR)
- Corresponding author
- Lima-Oliveira, Gabriel
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2017-03-07
- Volume
- 77
- Issue
- 3
- Pages
- 153-163
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2594178814
- Semantic Scholar
- 2162697a3061c121e955373716f887bc13b73cb8
- Cited by
- 117
- References
- 93
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 15 · 2023: 16 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 10 · 2018: 11 · 2017: 10
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- pre-analytical phase, laboratory errors, blood sampling, venipuncture, patient preparation, laboratory variability, specimen management, laboratory quality management
- MeSH terms
- Blood Specimen Collection, Diagnostic Errors, Fasting, Hematology, Humans, Laboratories, Total Quality Management, Phlebotomy, Patient Positioning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.