Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
For almost two decades, caesium fountain primary frequency standards (PFS) have represented the best realization of the definition of the second in the International System of units. Their accuracy has progressively improved with time, reaching a few parts in 10 16 . In this paper, we present the accuracy evaluation of ITCsF2, the new Cs fountain PFS developed at the Italian National Metrological Institute, designed to be operated at cryogenic temperature to reduce the blackbody radiation shift. The short-term stability of the ITCsF2 fountain is 2 × 10 −13 τ −1/2 when operated at high atomic density, and the relative inaccuracy reaches 2.3 × 10 −16 . We also report four calibrations of International Atomic Time with a relative frequency agreement of (−1.7 ± 3.2) × 10 −16 , between ITCsF2 and the average of the other fountains operated in the world during the reference periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Uncertainty of a frequency comparison with distributed dead time and measurement interval offset
Yu, D.-H., Weiss, M., & Parker, T. E. (2007) · Metrologia · doi:10.1088/0026-1394/44/1/014 · Cited by 44
Gravitational redshift at INRIM
Calonico, D., Cina, A., Bendea, I. H., Levi, F., Lorini, L., & Godone, A. (2007) · Metrologia · doi:10.1088/0026-1394/44/5/n03 · Cited by 22
Self-citation
Research works printed but not linked: 38
- Clairon A, 1996, Proc. 5th Symp. on Frequency Standards and Metrology, 49
- Jefferts S R, 2002, Metrologia, 39, 321, 10.1088/0026-1394/39/4/1 · DOI · Paper page
- Gerginov V, 2010, Metrologia, 47, 65, 10.1088/0026-1394/47/1/008 · DOI · Paper page
- Weyers S, 2001, Metrologia, 38, 497, 10.1088/0026-1394/38/4/7 · DOI · Paper page
- Levi F, 2006, Metrologia, 43, 545, 10.1088/0026-1394/43/6/010 · DOI · Paper page
- 10.1109/TUFFC.2012.2208 · DOI · Paper page
- Li R X, 2011, Metrologia, 48, 283, 10.1088/0026-1394/48/5/007 · DOI · Paper page
- Kumagai M, 2008, Metrologia, 45, 139, 10.1088/0026-1394/45/2/003 · DOI
- 10.1109/TIM.2004.823313 · DOI
- Wynands R, 2005, Metrologia, 42, S64, 10.1088/0026-1394/42/3/S08 · DOI · Paper page
- Parker T E, 2010, Metrologia, 47, 1, 10.1088/0026-1394/47/1/001 · DOI · Paper page
- 10.1109/TUFFC.2005.1563276 · DOI
- 10.1109/TUFFC.2006.1678186 · DOI
- 10.1109/TUFFC.2006.186 · DOI
- 10.1109/TUFFC.2009.1188 · DOI
- 10.1103/PhysRevLett.97.073002 · DOI
- 10.1103/PhysRevLett.106.130801 · DOI · Paper page
- Li R X, 2010, Metrologia, 47, 534, 10.1088/0026-1394/47/5/004 · DOI
- 10.1109/TUFFC.2010.1453 · DOI
- 10.1109/TUFFC.2004.1350948 · DOI
- Jefferts S R, 1998, Proc. IEEE Symp. on Frequency Control, 6
- 10.1063/1.1930095 · DOI · Paper page
- Calosso C, 2001, Proc. 15th EFTF, 412
- 10.1109/19.918177 · DOI
- 10.1103/PhysRevLett.112.050801 · DOI · Paper page
- 10.1103/PhysRevA.79.013404 · DOI
- 10.1103/PhysRevLett.97.040802 · DOI · Paper page
- Heavner T P, 2005, Proc. Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 308
- Guena J, 2010, Proc. IEEE Frequency Control Symp., 307
- Weyers S, 2012, Metrologia, 49, 82, 10.1088/0026-1394/49/1/012 · DOI · Paper page
- 10.1887/085274434X · DOI · Paper page
- 10.1103/PhysRevA.74.043401 · doi:10.1103/physreva.74.043401
- 10.1063/1.3606641 · doi:10.1063/1.3606641
- 10.1103/PhysRevA.13.1052 · DOI
- 10.1103/PhysRevLett.110.180802 · DOI · Paper page
- Bauch A, 2006, Metrologia, 43, 109, 10.1088/0026-1394/43/1/016 · DOI · Paper page
- Panfilo G, 2007, Proc. Joint Meeting. IEEE Int. Frequency Control Symp. and EFTF Conf., 805
- Parker T E, 2007, Proc. Joint Meeting. IEEE Int. Frequency Control Symp. and EFTF Conf., 986
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationDenker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
“…(NPL) in 1955, the accuracy of caesium microwave fre- H. Denker et al. quency standards has improved continuously and the best primary standards now have fractional uncertainties of a few parts in 1016 (Heavner et al. 2014; Levi et al. 2014; Guena et al. 2012; Weyers et al. 2012; Li et al. 2011).”
BackgroundPizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Self-citationDirect comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Self-citation
Metadata
- Authors
- Levi, F., Calonico, D., Calosso, C. E., Godone, A., Micalizio, S., & Costanzo, G. A.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-05-28
- Volume
- 51
- Issue
- 3
- Pages
- 270-284
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2084591380
- Cited by
- 134
- References
- 3
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain. https://app.cochat.ai/papers/10.1088/0026-1394/51/3/270
- The paper
- Levi, F., Calonico, D., Calosso, C. E., Godone, A., Micalizio, S., & Costanzo, G. A. (2014). Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain. Metrologia. https://doi.org/10.1088/0026-1394/51/3/270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.