Magnetic resonance elastography (MRE) of the human brain: technique, findings and clinical applications
Open accessThe DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Abstract
Neurological disorders are one of the most important public health concerns in developed countries. Established brain imaging techniques such as magnetic resonance imaging (MRI) and x-ray computerised tomography (CT) have been essential in the identification and diagnosis of a wide range of disorders, although usually are insufficient in sensitivity for detecting subtle pathological alterations to the brain prior to the onset of clinical symptoms-at a time when prognosis for treatment is more favourable. The mechanical properties of biological tissue provide information related to the strength and integrity of the cellular microstructure. In recent years, mechanical properties of the brain have been visualised and measured non-invasively with magnetic resonance elastography (MRE), a particularly sensitive medical imaging technique that may increase the potential for early diagnosis. This review begins with an introduction to the various methods used for the acquisition and analysis of MRE data. A systematic literature search is then conducted to identify studies that have specifically utilised MRE to investigate the human brain. Through the conversion of MRE-derived measurements to shear stiffness (kPa) and, where possible, the loss tangent (rad), a summary of results for global brain tissue and grey and white matter across studies is provided for healthy participants, as potential baseline values to be used in future clinical investigations. In addition, the extent to which MRE has revealed significant alterations to the brain in patients with neurological disorders is assessed and discussed in terms of known pathophysiology. The review concludes by predicting the trends for future MRE research and applications in neuroscience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McKhann, G., Drachman, D., Folstein, M., Katzman, R., Price, D., & Stadlan, E. M. (1984) · Neurology · doi:10.1212/wnl.34.7.939 · Cited by 27,915 · cited 1×
“ii) Alzheimer’s disease (AD) - AD is a progressive impairment of cognitive function, typically beginning with episodic memory, and is characterised pathologically by extracellular amyloid plaques and intracellular neurofib-rillary tangles (McKhann et al 1984).”
BackgroundSingle-cell RNA-seq highlights intratumoral heterogeneity in primary glioblastoma
Patel, A. P., Tirosh, I., Trombetta, J. J., Shalek, A. K., Gillespie, S. M., Wakimoto, H., Cahill, D. P., Nahed, B. V., Curry, W. T., Martuza, R. L., et al. (2014) · Science · doi:10.1126/science.1254257 · Cited by 5,063
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 1×
“MRE is a phase-contrast MRI technique that involves imaging the propagation of applied acoustic waves using a modified MRI pulse sequence (Muthupillai et al 1995, Muthupillai and Ehman 1996).”
MethodMagnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Elad, M., & Feuer, A. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.650118 · Cited by 1,035 · cited 5×
“In addition, for the first time, MRE has been combined with the Stationary Super-Resolution (SSR) technique, in which multiple lower-resolution images from the same scene are interpolated and fused to create a single higher-resolution image (Elad and Feuer 1997).”
MethodInfluentialElastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Mechanical properties of gray and white matter brain tissue by indentation
Budday, S., Nay, R., de Rooij, R., Steinmann, P., Wyrobek, T., Ovaert, T. C., & Kuhl, E. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.02.024 · Cited by 692
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659 · cited 1×
“Importantly, MRE parameters have been corroborated with histological samples (Venkatesh et al 2013), biopsy-proven liver fibrosis (Asbach et al 2010), and displays high diagnostic accurary and inter-reader agreement (Rustogi et al 2012).”
BackgroundGeneralized viscoelastic models: their fractional equations with solutions
Schiessel, H., Metzler, R., Blumen, A., & Nonnenmacher, T. F. (1995) · Journal of Physics A: Mathematical and General · doi:10.1088/0305-4470/28/23/012 · Cited by 629
Schulz-Schaeffer, W. J. (2010) · Acta Neuropathologica · doi:10.1007/s00401-010-0711-0 · Cited by 627
Clinical, genetic and pathological heterogeneity of frontotemporal dementia: A review
Seelaar, H., Rohrer, J. D., Pijnenburg, Y. A. L., Fox, N. C., & van Swieten, J. C. (2011) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2010.212225 · Cited by 609
Viscoelastic properties of individual glial cells and neurons in the CNS
Lu, Y.-B., Franze, K., Seifert, G., Steinhäuser, C., Kirchhoff, F., Wolburg, H., Guck, J., Janmey, P., Wei, E.-Q., Käs, J., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606150103 · Cited by 578 · cited 1×
“In contrast, GM has been found to be stiffer than WM on an individual cell level (Lu et al 2006).”
BackgroundViscoelastic shear properties of in vivo breast lesions measured by MR elastography
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., & Fink, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.060 · Cited by 503 · cited 1×
“High-pass filtering or calculating the vector curl of the measured wave field (Sinkus et al 2005), are two common approaches to remove low-frequency bulk waves, and leave only the remaining high-frequency shear wave contribution.”
BackgroundLoomba, R., Wolfson, T., Ang, B., Hooker, J., Behling, C., Peterson, M., Valasek, M., Lin, G., Brenner, D., Gamst, A., et al. (2014) · Hepatology · doi:10.1002/hep.27362 · Cited by 489 · cited 1×
“The application of MRE to the study of patients with liver disease has proven to be successful in measuring the degree of fibrosis (Loomba et al 2014), which presents with an increase in tissue stiffness.”
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481 · cited 1×
“Other organs to have been investigated include heart (Elgeti et al 2010, Kolipaka et al 2009), breast (Sinkus et al 2000, 2007, Siegmann et al 2010) skeletal muscle (Bensamoun et al 2007, Chen et al 2008), lungs (Mariappan et al 2014, Goss et al 2006), kidney (Bensamoun et al 2011, Streitberger et…”
BackgroundImaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477 · cited 1×
“In addition, higher WM viscosity is also consistent with the microstructural architecture of GM and WM, and found to reflect the network properties of WM found at the macromolecular level (Franceschini et al 2006). Particularly high values for the loss tangent are evident in Braun et al (2014), with 0.”
BackgroundFast phase unwrapping algorithm for interferometric applications
Schofield, M. A., & Zhu, Y. (2003) · Optics Letters · doi:10.1364/ol.28.001194 · Cited by 454
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424 · cited 2×
“MEGs have been incorporated into a number of MRI imaging sequences, including gradient-recalled echo (GRE) (Xu et al 2007a, Kruse et al 2008) single-shot spin-echo Echo Planar Imaging (EPI) (Murphy et al 2011, Braun et al 2014, Zhang et al 2011), multi-shot, variable density spiral (Johnson et al…”
ResultThe impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423 · cited 6×
“Some studies have therefore utilised a range of vibration frequencies to enable rheological modelling of the frequency-dependent material properties, providing an opportunity to enhance tissue characterisation (Klatt et al 2007, Sack et al 2009).”
BackgroundMethodResultInfluentialIn vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Oliphant, T. E., Manduca, A., Ehman, R. L., & Greenleaf, J. F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<299::aid-mrm1039>3.0.co;2-o · Cited by 411
Brain tissue deforms similarly to filled elastomers and follows consolidation theory
Franceschini, G., Bigoni, D., Regitnig, P., & Holzapfel, G. A. (2006) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2006.05.004 · Cited by 385
Decreased brain stiffness in Alzheimer's disease determined by magnetic resonance elastography
Murphy, M. C., Huston, J., Jack, C. R., Glaser, K. J., Manduca, A., Felmlee, J. P., & Ehman, R. L. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22707 · Cited by 348
Self-citationKlatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
Sinkus, R., Siegmann, K., Xydeas, T., Tanter, M., Claussen, C., & Fink, M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21404 · Cited by 332
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316 · cited 1×
“Potential external sources include electromagnetic (Xu et al 2007b, Braun et al 2014), acousto-mechanical (Sack et al 2008, Lipp et al 2013) pneumatic (Johnson et al 2014, Huston et al 2015), and piezoelectric (Guo et al 2013) devices, which transmit vibrations to the head via a passive driver such…”
BackgroundMR-elastography reveals degradation of tissue integrity in multiple sclerosis
Wuerfel, J., Paul, F., Beierbach, B., Hamhaber, U., Klatt, D., Papazoglou, S., Zipp, F., Martus, P., Braun, J., & Sack, I. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.018 · Cited by 309
Magnetic resonance elastography
Muthupillai, R., & Ehman, R. L. (1996) · Nature Medicine · doi:10.1038/nm0596-601 · Cited by 284
A model for longitudinal and shear wave propagation in viscoelastic media
Szabo, T. L., & Wu, J. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.428630 · Cited by 274
Assessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264 · cited 1×
“Viscoelastic models include the Maxwell model, Kelvin-Voigt model, and the Zener model, among others (Schiessel et al 1995, Asbach et al 2008).”
MethodBrain Viscoelasticity Alteration in Chronic-Progressive Multiple Sclerosis
Streitberger, K.-J., Sack, I., Krefting, D., Pfüller, C., Braun, J., Paul, F., & Wuerfel, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029888 · Cited by 238
Arani, A., Murphy, M. C., Glaser, K. J., Manduca, A., Lake, D. S., Kruse, S. A., Jack, C. R., Ehman, R. L., & Huston, J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.016 · Cited by 236 · cited 4×
“The mechanical properties of various brain regions have been investigated in a number of recent studies (Guo et al 2013, Johnson et al 2013a, 2016, Murphy et al 2013b, Arani et al 2015, Huston et al 2015). In studies characterising lobes of the brain, all were in agreement that the stiffest region of the brain was the…”
BackgroundResultInfluentialSelf-citationViscoelasticity-based Staging of Hepatic Fibrosis with Multifrequency MR Elastography
Asbach, P., Klatt, D., Schlosser, B., Biermer, M., Muche, M., Rieger, A., Loddenkemper, C., Somasundaram, R., Berg, T., Hamm, B., et al. (2010) · Radiology · doi:10.1148/radiol.10092489 · Cited by 229
Schregel, K., Wuerfel née Tysiak, E., Garteiser, P., Gemeinhardt, I., Prozorovski, T., Aktas, O., Merz, H., Petersen, D., Wuerfel, J., & Sinkus, R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200151109 · Cited by 228
A new ultrasound tissue-equivalent material.
Burlew, M. M., Madsen, E. L., Zagzebski, J. A., Banjavic, R. A., & Sum, S. W. (1980) · Radiology · doi:10.1148/radiology.134.2.7352242 · Cited by 221 · cited 2×
“…speed ( ν s ) is a function of the applied mechanical frequency (f) and the wavelength ( λ ), and is related to an approximated density ρ ( ∼ 1000kg/m 3 ) (Burlew et al 1980), and elastic shear modulus G by the following relationship: Manual measurements of the wavelength were initially made…”
BackgroundAn overlapping subzone technique for MR-based elastic property reconstruction
Van Houten, E. E. W., Paulsen, K. D., Miga, M. I., Kennedy, F. E., & Weaver, J. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4<779::aid-mrm21>3.0.co;2-z · Cited by 214
Edelman, R. R., & Warach, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303113281008 · Cited by 213 · cited 1×
“Conventional MRI applies a sequence of radiofrequency (RF) excitation pulses and phase and frequency encoding gradients to produce an image by encoding the spatial position of hydrogen nuclei (spins) in voxels within a tissue (Edelman and Warach 1993).”
BackgroundRegional brain stiffness changes across the Alzheimer's disease spectrum
Murphy, M. C., Jones, D. T., Jack, C. R., Glaser, K. J., Senjem, M. L., Manduca, A., Felmlee, J. P., Carter, R. E., Ehman, R. L., & Huston, J. (2016) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.12.007 · Cited by 207
Self-citationLocal mechanical properties of white matter structures in the human brain
Johnson, C. L., McGarry, M. D. J., Gharibans, A. A., Weaver, J. B., Paulsen, K. D., Wang, H., Olivero, W. C., Sutton, B. P., & Georgiadis, J. G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.089 · Cited by 199
Self-citationSack, I., Jöhrens, K., Würfel, J., & Braun, J. (2013) · Soft Matter · doi:10.1039/c3sm50552a · Cited by 194 · cited 2×
“The magnitude of the tissue response is the parameter most similar to the information afforded by manual palpation (Sack et al 2013), as the total response includes both the displacement (elasticity) and rate of displacement (viscosity).”
BackgroundMethodThe Influence of Physiological Aging and Atrophy on Brain Viscoelastic Properties in Humans
Sack, I., Streitberger, K.-J., Krefting, D., Paul, F., & Braun, J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023451 · Cited by 189
Murphy, M. C., Huston, J., Glaser, K. J., Manduca, A., Meyer, F. B., Lanzino, G., Morris, J. M., Felmlee, J. P., & Ehman, R. L. (2013) · Journal of Neurosurgery · doi:10.3171/2012.9.jns12519 · Cited by 186
Self-citationCNS Cell Distribution and Axon Orientation Determine Local Spinal Cord Mechanical Properties
Koser, D. E., Moeendarbary, E., Hanne, J., Kuerten, S., & Franze, K. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.03.039 · Cited by 177
Mechanical transient‐based magnetic resonance elastography
McCracken, P. J., Manduca, A., Felmlee, J., & Ehman, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20388 · Cited by 175
Local multiscale frequency and bandwidth estimation
Knutsson, H., Westin, C.-F., & Granlund, G. (2002) · Proceedings of 1st International Conference on Image Processing · doi:10.1109/icip.1994.413270 · Cited by 175 · cited 2×
“The shear wave speed ( ν s ) is a function of the applied mechanical frequency (f) and the wavelength ( λ ), and is related to an approximated density ρ ( ∼ 1000kg/m 3 ) (Burlew et al 1980), and elastic shear modulus G by the following relationship: Manual measurements of the wavelength were initially made using calip…”
MethodHigh-Resolution Mechanical Imaging of Glioblastoma by Multifrequency Magnetic Resonance Elastography
Streitberger, K.-J., Reiss-Zimmermann, M., Freimann, F. B., Bayerl, S., Guo, J., Arlt, F., Wuerfel, J., Braun, J., Hoffmann, K.-T., & Sack, I. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110588 · Cited by 173
In vivo viscoelastic properties of the brain in normal pressure hydrocephalus
Streitberger, K., Wiener, E., Hoffmann, J., Freimann, F. B., Klatt, D., Braun, J., Lin, K., McLaughlin, J., Sprung, C., Klingebiel, R., et al. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1602 · Cited by 171
Determination of thigh muscle stiffness using magnetic resonance elastography
Bensamoun, S. F., Ringleb, S. I., Littrell, L., Chen, Q., Brennan, M., Ehman, R. L., & An, K. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20487 · Cited by 165
An octahedral shear strain-based measure of SNR for 3D MR elastography
McGarry, M., Houten, E. E. W. V., Perriñez, P. R., Pattison, A. J., Weaver, J. B., & Paulsen, K. D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/13/n02 · Cited by 161
Self-citationMeasuring the Characteristic Topography of Brain Stiffness with Magnetic Resonance Elastography
Murphy, M. C., Huston, J., Jack, C. R., Glaser, K. J., Senjem, M. L., Chen, J., Manduca, A., Felmlee, J. P., & Ehman, R. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081668 · Cited by 160
Self-citationMultiresolution MR elastography using nonlinear inversion
McGarry, M. D. J., Van Houten, E. E. W., Johnson, C. L., Georgiadis, J. G., Sutton, B. P., Weaver, J. B., & Paulsen, K. D. (2012) · Medical Physics · doi:10.1118/1.4754649 · Cited by 158
Self-citationRustogi, R., Horowitz, J. M., Harmath, C. B., Wang, Y., Chalian, H., Ganger, D. R., Chen, Z. E., Bolster, B. D., Shah, S., & Miller, F. H. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23585 · Cited by 156
Algebraic Helmholtz inversion in planar magnetic resonance elastography
Papazoglou, S., Hamhaber, U., Braun, J., & Sack, I. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/12/005 · Cited by 144 · cited 1×
“Frequencies above 100Hz are generally not used, however, due to discretisation errors (Papazoglou et al 2008) (i.e. where the wave cannot be sampled correctly), and for participant comfort, as higher frequencies require greater amplitude levels to penetrate the skull.”
BackgroundIn vivo waveguide elastography of white matter tracts in the human brain
Romano, A. J., Scheel, M., Hirsch, S., Braun, J., & Sack, I. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24141 · Cited by 143 · cited 6×
“Other studies have corrected for the isotropic assumption during the inversion procedure after the determination of nerve fibre orientation supplied from diffusion-tensor imaging (DTI) (Romano et al 2012, 2014).”
MethodInfluentialJohnson, C. L., McGarry, M., Houten, E. E. W. V., Weaver, J. B., Paulsen, K. D., Sutton, B. P., & Georgiadis, J. G. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24473 · Cited by 135 · cited 5×
“…including gradient-recalled echo (GRE) (Xu et al 2007a, Kruse et al 2008) single-shot spin-echo Echo Planar Imaging (EPI) (Murphy et al 2011, Braun et al 2014, Zhang et al 2011), multi-shot, variable density spiral (Johnson et al 2013b) and 3D multi-shot multi-slab spiral EPI (Johnson et al 2014).”
BackgroundMethodResultInfluentialSelf-citationAbility of magnetic resonance elastography to assess taut bands
Chen, Q., Basford, J. R., & An, K. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.12.002 · Cited by 132 · cited 1×
“…include heart (Elgeti et al 2010, Kolipaka et al 2009), breast (Sinkus et al 2000, 2007, Siegmann et al 2010) skeletal muscle (Bensamoun et al 2007, Chen et al 2008), lungs (Mariappan et al 2014, Goss et al 2006), kidney (Bensamoun et al 2011, Streitberger et al 2014a), and prostate (Arani et al…”
BackgroundUrayama, K., Kawamura, T., & Kohjiya, S. (2008) · Polymer · doi:10.1016/j.polymer.2008.10.027 · Cited by 130 · cited 1×
“However, in some complex and irregular materials, φ becomes less sensitive to frequency and thus φ = α × π /2, may hold true (Urayama et al 2009).”
BackgroundTowards an Elastographic Atlas of Brain Anatomy
Guo, J., Hirsch, S., Fehlner, A., Papazoglou, S., Scheel, M., Braun, J., & Sack, I. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071807 · Cited by 128
Multifrequency inversion in magnetic resonance elastography
Papazoglou, S., Hirsch, S., Braun, J., & Sack, I. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/8/2329 · Cited by 127 · cited 2×
“Another alternative and innovative MRE analysis approach is to utilise the Helmholtz equation over several actuation frequencies and include a summation within a single inversion using an algebraic least-squares solution related to the spring-pot model (Papazoglou et al 2012).”
BackgroundMethodInfluentialTransmission, attenuation and reflection of shear waves in the human brain
Clayton, E. H., Genin, G. M., & Bayly, P. V. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0325 · Cited by 127
Magnetic resonance elastography of brain tumors: preliminary results
Xu, L., Lin, Y., Han, J. C., Xi, Z. N., Shen, H., & Gao, P. Y. (2007) · Acta Radiologica · doi:10.1080/02841850701199967 · Cited by 125 · cited 6×
“The most common sequence for brain MRE has been a single-shot spin-echo EPI sequence, which is capable of acquiring 3D displacement data within a short imaging time in comparison to the original GRE sequences adapted for MRE.”
BackgroundMethodResultInfluentialReiss-Zimmermann, M., Streitberger, K., Sack, I., Braun, J., Arlt, F., Fritzsch, D., & Hoffmann, K. (2014) · Clinical Neuroradiology · doi:10.1007/s00062-014-0311-9 · Cited by 125
Viscoelastic properties of human cerebellum using magnetic resonance elastography
Zhang, J. H., Green, M. A., Sinkus, R., & Bilston, L. E. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.034 · Cited by 122 · cited 2×
“In contrast, the cerebellum was found to be the softest region investigated, supporting findings from (Zhang et al 2011) who found both GM and WM of the cerebellum to be softer than the corresponding compartments of the cerebrum.”
BackgroundJohnson, C. L., Holtrop, J. L., McGarry, M., Weaver, J. B., Paulsen, K. D., Georgiadis, J. G., & Sutton, B. P. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25065 · Cited by 118 · cited 3×
“FEM methods are known as the "forward problem", as prior knowledge of tissue geometry, boundary conditions, and mechanical properties are needed to initially build a model simulation (Van Houten et al 1999, McGarry et al 2012).”
MethodSelf-citationCerebral magnetic resonance elastography in supranuclear palsy and idiopathic Parkinson's disease
Lipp, A., Trbojevic, R., Paul, F., Fehlner, A., Hirsch, S., Scheel, M., Noack, C., Braun, J., & Sack, I. (2013) · NeuroImage Clinical · doi:10.1016/j.nicl.2013.09.006 · Cited by 117 · cited 4×
“Values represent mean and standard deviation (SD) (Lipp et al 2013). vi) Amyotrophic Lateral Sclerosis (ALS) -”
BackgroundMethodInfluentialMeyer, F., Hoover, J., & Morris, J. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.85983 · Cited by 117
Alteration of brain viscoelasticity after shunt treatment in normal pressure hydrocephalus
Freimann, F. B., Streitberger, K., Klatt, D., Lin, K., McLaughlin, J. R., Braun, J., Sprung, C., & Sack, I. (2011) · Neuroradiology · doi:10.1007/s00234-011-0871-1 · Cited by 114
Emerging Brain Morphologies from Axonal Elongation
Holland, M. A., Miller, K. E., & Ellen Kuhl, A. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1312-9 · Cited by 112 · cited 1×
“Nonetheless, the original parameter was reported as sensitive to a variety of pathological processes, as described in both Streitberger et al (2014b) and Reiss-Zimmermann et al (2014). An increasing number of studies have investigated regional mechanical properties, including anatomical brain structures.”
BackgroundRiek, K., Millward, J. M., Hamann, I., Mueller, S., Pfueller, C. F., Paul, F., Braun, J., Infante-Duarte, C., & Sack, I. (2012) · NeuroImage: Clinical · doi:10.1016/j.nicl.2012.09.003 · Cited by 111
Viscoelasticity of subcortical gray matter structures
Johnson, C. L., Schwarb, H. D., McGarry, M., Anderson, A. T., Huesmann, G., Sutton, B. P., & Cohen, N. J. (2016) · Human Brain Mapping · doi:10.1002/hbm.23314 · Cited by 111 · cited 8×
“…lobes of the brain, all were in agreement that the stiffest region of the brain was the deep GM/WM - categorised by the authors as a composite region containing structures such as the thalamus, hypothalamus, and subthalamus (Murphy et (Johnson et al 2016) were stiffer than general cerebral tissue.”
BackgroundMethodResultInfluentialSelf-citationBraun, J., Guo, J., Lützkendorf, R., Stadler, J., Papazoglou, S., Hirsch, S., Sack, I., & Bernarding, J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.032 · Cited by 103 · cited 6×
“The new calculation of φ was 0.09rad, and the authors suggest that previous work from their group may have provided values that were overestimated (Braun et al 2014, Guo et al 2012).”
BackgroundResultInfluentialBrain mechanical property measurement using MRE with intrinsic activation
Weaver, J. B., Pattison, A. J., McGarry, M. D., Perreard, I. M., Swienckowski, J. G., Eskey, C. J., Lollis, S. S., & Paulsen, K. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7275 · Cited by 102
Self-citationMR Elastography Demonstrates Increased Brain Stiffness in Normal Pressure Hydrocephalus
Fattahi, N., Arani, A., Perry, A., Meyer, F. B., Manduca, A., Glaser, K. J., Senjem, M. L., Ehman, R. L., & Huston, J. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4560 · Cited by 102
Self-citationIn vivo wideband multifrequency MR elastography of the human brain and liver
Dittmann, F., Hirsch, S., Tzschätzsch, H., Guo, J., Braun, J., & Sack, I. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26006 · Cited by 102 · cited 3×
“As previously mentioned, these values are likely to have been overestimated due to systemic noise bias; subsequent work has focused on the recalculation of φ * (Dittmann et al 2015).”
BackgroundMethodResultInfluentialMedial temporal lobe viscoelasticity and relational memory performance
Schwarb, H., Johnson, C. L., McGarry, M. D. J., & Cohen, N. J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.059 · Cited by 100 · cited 1×
“This is supported, in particular, by a recent study by Schwarb et al (2016), who reported a high correlation between MRE hippocampal damping ratio and memory performance in healthy young adults.”
ResultSelf-citationMcGarry, M., Johnson, C. L., Sutton, B. P., Georgiadis, J. G., Houten, E. E. W. V., Pattison, A. J., Weaver, J. B., & Paulsen, K. D. (2015) · Medical Physics · doi:10.1118/1.4905048 · Cited by 100
Self-citationHamhaber, U., Sack, I., Papazoglou, S., Rump, J., Klatt, D., & Braun, J. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.08.007 · Cited by 98
Bensamoun, S. F., Ringleb, S. I., Chen, Q., Ehman, R. L., An, K., & Brennan, M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21073 · Cited by 92
Doyley, M. M., & Parker, K. J. (2013) · Ultrasound Clinics · doi:10.1016/j.cult.2013.09.006 · Cited by 92
Kolipaka, A., McGee, K. P., Araoz, P. A., Glaser, K. J., Manduca, A., Romano, A. J., & Ehman, R. L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21991 · Cited by 89
Anderson, A. T., Houten, E. E. W. V., McGarry, M., Paulsen, K. D., Holtrop, J. L., Sutton, B. P., Georgiadis, J. G., & Johnson, C. L. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.03.005 · Cited by 83 · cited 21×
“MRE values for GBT in healthy subjects have been reported in 13 studies, and converted to shear stiffness (kPa) and loss tangent (rad), where possible, see Table 3.”
BackgroundInfluentialSelf-citationMagnetic resonance elastography of the lung: Technical feasibility
Goss, B. C., McGee, K. P., Ehman, E. C., Manduca, A., & Ehman, R. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21053 · Cited by 79
Posnansky, O. P., Guo, J., Hirsch, S., Papazoglou, S., Braun, J., & Sack, I. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/12/4023 · Cited by 78
Bensamoun, S. F., Robert, L., Leclerc, G. E., Debernard, L., & Charleux, F. (2011) · Clinical Imaging · doi:10.1016/j.clinimag.2010.07.009 · Cited by 77
Freimann, F. B., Müller, S., Streitberger, K., Guo, J., Rot, S., Ghori, A., Vajkoczy, P., Reiter, R., Sack, I., & Braun, J. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2987 · Cited by 75 · cited 1×
“Investigations that have combined MRE and histology with murine models of disease have suggested that inflammation (Riek et al 2012), toxic demyelination (Schregel et al 2012), and transient ischemic insult (Freimann et al 2013), all directly alter mechanical property measurements.”
BackgroundSiegmann, K., Xydeas, T., Sinkus, R., Kraemer, B., Vogel, U. H., & Claussen, C. D. (2009) · European Radiology · doi:10.1007/s00330-009-1566-4 · Cited by 74
Vibration safety limits for magnetic resonance elastography
Ehman, E. C., Rossman, P. J., Kruse, S. A., Sahakian, A. V., & Glaser, K. J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/007 · Cited by 69
Hatt, A., Cheng, S., Tan, K., Sinkus, R., & Bilston, L. E. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4361 · Cited by 69
Magnetic resonance elastography of frontotemporal dementia
Huston, J., Murphy, M. C., Boeve, B. F., Fattahi, N., Arani, A., Glaser, K. J., Manduca, A., Jones, D. T., & Ehman, R. L. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24977 · Cited by 68 · cited 5×
“FEM-based approaches have the advantage of being able to incorporate the full equations of motion, and mechanical models such as Rayleigh damping (McGarry and Van Houten 2008, Van Houten et al 2011, Van Houten 2014) or poroelasticity (Perrinez et al 2010, McGarry et al 2015), which go beyond the assumptions of linear…”
BackgroundMethodResultInfluentialSelf-citationPerriez, P. R., Kennedy, F. E., Houten, E. E. W. V., Weaver, J. B., & Paulsen, K. D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035309 · Cited by 68
Romano, A., Guo, J., Prokscha, T., Meyer, T., Hirsch, S., Braun, J., Sack, I., & Scheel, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25067 · Cited by 67
Fehlner, A., Behrens, J. R., Streitberger, K., Papazoglou, S., Braun, J., Bellmann–Strobl, J., Ruprecht, K., Paul, F., Wuerfel, J. T., & Sack, I. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25129 · Cited by 66
Use of a Rayleigh damping model in elastography
McGarry, M., & Houten, E. E. W. V. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0356-5 · Cited by 62
Self-citationCardiac Magnetic Resonance Elastography
Elgeti, T., Beling, M., Hamm, B., Braun, J., & Sack, I. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181ec4b63 · Cited by 61 · cited 1×
“Other organs to have been investigated include heart (Elgeti et al 2010, Kolipaka et al 2009), breast (Sinkus et al 2000, 2007, Siegmann et al 2010) skeletal muscle (Bensamoun et al 2007, Chen et al 2008), lungs (Mariappan et al 2014, Goss et al 2006), kidney (Bensamoun et al 2011, Streitberger et…”
BackgroundNon-invasive characterization of intracranial tumors by magnetic resonance elastography
Simon, M., Guo, J., Papazoglou, S., Scholand-Engler, H. G., Erdmann, C., Melchert, U. H., Bonsanto, M. M., Braun, J., Petersen, D., Sack, I., et al. (2013) · New Journal of Physics · doi:10.1088/1367-2630/15/8/085024 · Cited by 57
Nonlinear multiscale regularisation in MR elastography: Towards fine feature mapping
Barnhill, E., Hollis, L., Sack, I., Braun, J., Hoskins, P. R., Pankaj, P., Brown, C., van Beek, E. J. R., & Roberts, N. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.05.012 · Cited by 57
Self-citationGuo, J., Posnansky, O. P., Hirsch, S., Scheel, M., Taupitz, M., Braun, J., & Sack, I. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/12/4041 · Cited by 55
Magnetic resonance elastography of the human brain: a preliminary study
Xu, L., Lin, Y., Xi, Z. N., Shen, H.-J., & Gao, P. (2007) · Acta Radiologica · doi:10.1080/02841850601026401 · Cited by 50 · cited 6×
“The most common sequence for brain MRE has been a single-shot spin-echo EPI sequence, which is capable of acquiring 3D displacement data within a short imaging time in comparison to the original GRE sequences adapted for MRE.”
BackgroundMethodResultInfluentialReal‐time 4D phase unwrapping applied to magnetic resonance elastography
Barnhill, E., Kennedy, P., Johnson, C. L., Mada, M., & Roberts, N. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25332 · Cited by 47 · cited 1×
“Several unwrapping algorithms have been developed each with their own strengths and weaknesses relating to delivery of the exact solution, robustness to high noise, or full automation (Schofield and Zhu 2003, Herráez et al 2002, Barnhill et al 2015).”
BackgroundSelf-citationKlatt, D., Johnson, C. L., & Magin, R. L. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24806 · Cited by 44
Self-citationSubzone based magnetic resonance elastography using a Rayleigh damped material model
Houten, E. E. W. V., Viviers, D., McGarry, M., Perriñez, P. R., Perreard, I. M., Weaver, J. B., & Paulsen, K. D. (2011) · Medical Physics · doi:10.1118/1.3557469 · Cited by 43
Self-citationMariappan, Y. K., Glaser, K. J., Levin, D. L., Vassallo, R., Hubmayr, R. D., MOTTRAM, C. D., Ehman, R. L., & McGee, K. P. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24479 · Cited by 41
Arani, A., Rosa, M. R. D., Ramsay, E. A., Plewes, D. B., Haider, M. A., & Chopra, R. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24028 · Cited by 32
Alroughani, R., Al Hashel, J., Lamdhade, S., & Ahmed, S. F. (2012) · ISRN Neurology · doi:10.5402/2012/792192 · Cited by 28
Cerebral multifrequency MR elastography by remote excitation of intracranial shear waves
Fehlner, A., Papazoglou, S., McGarry, M., Paulsen, K. D., Guo, J., Streitberger, K., Hirsch, S., Braun, J., & Sack, I. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3388 · Cited by 24 · cited 1×
“MDEV reveals details of brain anatomy in a pixel-wise resolution (Guo et al 2013, Braun et al 2014), that clearly outperforms the resolution of single-frequency DI (Sack et al 2011). MDEV, like single-frequency based DI, however, assumes local homogeneity, and thus the quantitative performance in heterogeneous tissue…”
BackgroundSelf-citationElasticity reconstruction: Beyond the assumption of local homogeneity
Sinkus, R., Daire, J., BEERS, B. E. V., & Vilgrain, V. (2010) · Comptes Rendus Mécanique · doi:10.1016/j.crme.2010.07.014 · Cited by 19 · cited 1×
“Attempts have been made to take first order spatial derivatives into account in order to overcome this assumption although this approach has yet to be applied to the brain (Sinkus et al 2010).”
MethodEvaluation of Neonatal Brain Development Using Acoustic Radiation Force Impulse Imaging (ARFI)
Su, Y., Ma, J., Du, L., Xia, J., Wu, Y., Jia, X., Cai, Y. G., Li, Y. H., Zhao, J., & Liu, Q. (2015) · Neurophysiology · doi:10.1007/s11062-015-9539-5 · Cited by 9 · cited 3×
“Numerous studies have applied ultrasonic techniques to study the mechanical properties of the human brain, such as freehand quasistatic ultrasound elastography (Chakraborty et al 2012) and acoustic radiation force impulse imaging (ARFI) (Su et al 2015), with potential applications within neurosurgery and the study of…”
BackgroundInfluentialHughes, J. H., Fattahi, N., Gompel, J. J. V., Arani, A., Lanzino, G. S., Link, M., Meyer, F., Erhman, R., & Huston, J. (2015) · Journal of Neurological Surgery Part B Skull Base · doi:10.1055/s-0035-1546604 · Cited by 4
Self-citation
Cited by
MR elastography: Principles, guidelines, and terminology
Manduca, A., Bayly, P. V., Ehman, R. L., Kolipaka, A., Royston, T. J., Sack, I., Sinkus, R., & Van Beers, B. E. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28627 · Cited by 265
Viscoelastic Cell Microenvironment: Hydrogel‐Based Strategy for Recapitulating Dynamic ECM Mechanics
Ma, Y., Han, T., Yang, Q., Wang, J., Feng, B., Jia, Y., Wei, Z., & Xu, F. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202100848 · Cited by 213
MR elastography of the brain and its application in neurological diseases
Murphy, M. C., Huston, J., & Ehman, R. L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.008 · Cited by 196
“While we present an overview of the MRE method here, a thorough review of all methodologies used in the brain MRE literature can be found in (Hiscox et al., 2016).”
Self-citationMagnetic Resonance Elastography of Liver
Venkatesh, S. K., & Ehman, R. L. (2014) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2014.05.001 · Cited by 174
Viscoelasticity in natural tissues and engineered scaffolds for tissue reconstruction
Huang, D., Huang, Y., Xiao, Y., Yang, X., Lin, H., Feng, G., Zhu, X., & Zhang, X. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.013 · Cited by 168
Metadata
- Authors
- Hiscox, L. V., Johnson, C. L., Barnhill, E., McGarry, M. D. J., Huston, J., van Beek, E. J. R., Starr, J. M., & Roberts, N.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2016-11-15
- Volume
- 61
- Issue
- 24
- Pages
- R401-R437
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2555789137
- Cited by
- 230
- References
- 109
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.