Nuclear physics in particle therapy: a review
Open accessThe DOI matches its Crossref record; 184 of the 184 references it cites were found in a registry or an index.
Abstract
Charged particle therapy has been largely driven and influenced by nuclear physics. The increase in energy deposition density along the ion path in the body allows reducing the dose to normal tissues during radiotherapy compared to photons. Clinical results of particle therapy support the physical rationale for this treatment, but the method remains controversial because of the high cost and of the lack of comparative clinical trials proving the benefit compared to x-rays. Research in applied nuclear physics, including nuclear interactions, dosimetry, image guidance, range verification, novel accelerators and beam delivery technologies, can significantly improve the clinical outcome in particle therapy. Measurements of fragmentation cross-sections, including those for the production of positron-emitting fragments, and attenuation curves are needed for tuning Monte Carlo codes, whose use in clinical environments is rapidly increasing thanks to fast calculation methods. Existing cross sections and codes are indeed not very accurate in the energy and target regions of interest for particle therapy. These measurements are especially urgent for new ions to be used in therapy, such as helium. Furthermore, nuclear physics hardware developments are frequently finding applications in ion therapy due to similar requirements concerning sensors and real-time data processing. In this review we will briefly describe the physics bases, and concentrate on the open issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Siegel, R. L., Miller, K. D., & Jemal, A. (2015) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21254 · Cited by 11,853
Eidelman, S., Hayes, K. G., Olive, K. A., Aguilar-Benitez, M., Amsler, C., Asner, D., Babu, K. S., Barnett, R. M., Beringer, J., Burchat, P. R., et al. (2004) · Physics Letters B · doi:10.1016/j.physletb.2004.06.001 · Cited by 6,673
Beringer, J., Arguin, J. F., Barnett, R. M., Copic, K., Dahl, O., Groom, D. E., Lin, C. J., Lys, J., Murayama, H., Wohl, C. G., et al. (2012) · Physical Review D · doi:10.1103/physrevd.86.010001 · Cited by 5,978
Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer
Darby, S. C., Ewertz, M., McGale, P., Bennet, A. M., Blom-Goldman, U., Brønnum, D., Correa, C., Cutter, D., Gagliardi, G., Gigante, B., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1209825 · Cited by 3,974
Chadwick, M. B., Herman, M., Obložinský, P., Dunn, M. E., Danon, Y., Kahler, A. C., Smith, D. L., Pritychenko, B., Arbanas, G., Arcilla, R., et al. (2011) · Nuclear Data Sheets · doi:10.1016/j.nds.2011.11.002 · Cited by 2,881
Prescribing, recording, and reporting photon beam therapy
Icru (1993) · Medical Entomology and Zoology · Cited by 1,996
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationRange uncertainties in proton therapy and the role of Monte Carlo simulations
Paganetti, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/r99 · Cited by 1,325
Self-citationTOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Self-citationTissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Review of laser-driven ion sources and their applications
Daido, H., Nishiuchi, M., & Pirozhkov, A. S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/5/056401 · Cited by 1,053
Paganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915
Self-citationRecent progress in pancreatic cancer
Wolfgang, C. L., Herman, J. M., Laheru, D. A., Klein, A. P., Erdek, M. A., Fishman, E. K., & Hruban, R. H. (2013) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21190 · Cited by 910
Conversion coefficients for use in radiological protection against external radiation.
Smith, H. G. (1997) · Cited by 901
Molière's Theory of Multiple Scattering
Bethe, H. A. (1953) · Physical Review · doi:10.1103/physrev.89.1256 · Cited by 889
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Calculations of nuclear stopping, ranges, and straggling in the low-energy region
Wilson, W. D., Haggmark, L. G., & Biersack, J. P. (1977) · Physical Review B · doi:10.1103/physrevb.15.2458 · Cited by 816
Heavy-ion tumor therapy: Physical and radiobiological benefits
Schardt, D., Elsässer, T., & Schulz-Ertner, D. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.383 · Cited by 778
Charged particles in radiation oncology
Durante, M., & Loeffler, J. S. (2010) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.183 · Cited by 737
Self-citationMagnetic scanning system for heavy ion therapy
Haberer, T., Becher, W., Schardt, D., & Kraft, G. (1993) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(93)91335-k · Cited by 730
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
Particle Radiation Therapy Using Proton and Heavier Ion Beams
Schulz-Ertner, D., & Tsujii, H. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.7816 · Cited by 622
In vivoproton range verification: a review
Knopf, A. C., & Lomax, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/15/r131 · Cited by 620
Comments on ICRU Report No. 49: Stopping Powers and Ranges for Protons and Alpha Particles
Ziegler, J. F. (1999) · Radiation Research · doi:10.2307/3580097 · Cited by 616
Imaging hypoxia to improve radiotherapy outcome
Horsman, M. R., Mortensen, L. S., Petersen, J. B., Busk, M., & Overgaard, J. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.171 · Cited by 614
Carbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience
Kamada, T., Tsujii, H., Blakely, E. A., Debus, J., De Neve, W., Durante, M., Jäkel, O., Mayer, R., Orecchia, R., Pötter, R., et al. (2015) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70412-7 · Cited by 562
Self-citationLangendijk, J. A., Lambin, P., De Ruysscher, D., Widder, J., Bos, M., & Verheij, M. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.05.007 · Cited by 549
Bragg-peak proton-beam therapy for arteriovenous malformations of the brain
Kjellberg, R. N., Hanamura, T., Davis, K. R., Lyons, S. L., & Adams, R. D. (1983) · New England Journal of Medicine · doi:10.1056/nejm198308043090503 · Cited by 540
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528 · cited 2×
“Fragmentation drastically modifies the Bragg curve, with a strong decrease of the dose in the entrance channel, more similar to photons than protons; a small Bragg peak caused by the few residual primary ions; and a long fragment tail (Durante and Cucinotta 2011).”
BackgroundMethodSelf-citationValentin, J. (2003) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00024-1 · Cited by 521
Stopping of energetic light ions in elemental matter
Ziegler, J. F. (1999) · Journal of Applied Physics · doi:10.1063/1.369844 · Cited by 495
Krämer, M., & Scholz, M. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/314 · Cited by 453
Goldin, G. H. (2012) · JAMA · doi:10.1001/jama.2012.460 · Cited by 445
Charged particle therapy—optimization, challenges and future directions
Loeffler, J. S., & Durante, M. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.79 · Cited by 426
Self-citationXu, X. G., Bednarz, B., & Paganetti, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/13/r01 · Cited by 415
Self-citationParodi, K., Paganetti, H., Shih, H. A., Michaud, S., Loeffler, J. S., DeLaney, T. F., Liebsch, N. J., Munzenrider, J. E., Fischman, A. J., Knopf, A., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.01.063 · Cited by 409
Self-citationAssessing the risk of second malignancies after modern radiotherapy
Newhauser, W. D., & Durante, M. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3069 · Cited by 380
Self-citationTheory of RBE for Heavy Ion Bombardment of Dry Enzymes and Viruses
Butts, J. J., & Katz, R. (1967) · Radiation Research · doi:10.2307/3572151 · Cited by 365
The Heavy Nuclei of the Primary Cosmic Radiation
Bradt, H. L., & Peters, B. (1950) · Physical Review · doi:10.1103/physrev.77.54 · Cited by 345
Microbubble ultrasound contrast agents: A review
Stride, E., & Saffari, N. (2003) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544110360729072 · Cited by 337
Radiotherapy with beams of carbon ions
Amaldi, U., & Kraft, G. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/8/r04 · Cited by 325
Motion in radiotherapy: particle therapy
Bert, C., & Durante, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/r01 · Cited by 315
Self-citationIncidence of Second Malignancies Among Patients Treated With Proton Versus Photon Radiation
Chung, C. S., Yock, T. I., Nelson, K., Xu, Y., Keating, N. L., & Tarbell, N. J. (2013) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2013.04.030 · Cited by 306
Malvezzi, M., Bertuccio, P., Rosso, T., Rota, M., Levi, F., La Vecchia, C., & Negri, E. (2015) · Annals of Oncology · doi:10.1093/annonc/mdv001 · Cited by 291
Friedrich, T., Scholz, U., ElsaSser, T., Durante, M., & Scholz, M. (2013) · Journal of Radiation Research · doi:10.1093/jrr/rrs114 · Cited by 287
Self-citationXu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
Inaniwa, T., Kanematsu, N., Matsufuji, N., Kanai, T., Shirai, T., Noda, K., Tsuji, H., Kamada, T., & Tsujii, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/3271 · Cited by 263
Patel, S. H., Wang, Z., Wong, W. W., Murad, M. H., Buckey, C. R., Mohammed, K., Alahdab, F., Altayar, O., Nabhan, M., Schild, S. E., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70268-2 · Cited by 262
Tommasino, F., & Durante, M. (2015) · Cancers · doi:10.3390/cancers7010353 · Cited by 252
Self-citationPaganetti, H. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/5/305 · Cited by 237
Self-citationAn evidence based review of proton beam therapy: The report of ASTRO’s emerging technology committee
Allen, A. M., Pawlicki, T., Dong, L., Fourkal, E., Buyyounouski, M., Cengel, K., Plastaras, J., Bucci, M. K., Yock, T. I., Bonilla, L., et al. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.02.001 · Cited by 236
Heavy-Ion Radiobiology: Cellular Studies
Blakely, E. A., Ngo, F. Q. H., Curtis, S. B., & Tobias, C. A. (1984) · Advances in Radiation Biology · doi:10.1016/b978-0-12-035411-5.50013-7 · Cited by 231
Peeters, A., Grutters, J. P. C., Pijls-Johannesma, M., Reimoser, S., De Ruysscher, D., Severens, J. L., Joore, M. A., & Lambin, P. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2009.12.002 · Cited by 228
Track structure analysis of ultrasoft X-rays compared to high- and low-LET radiations
Goodhead, D. T., & Nikjoo, H. (1989) · International Journal of Radiation Biology · doi:10.1080/09553008914550571 · Cited by 223
Parodi, K., Mairani, A., Brons, S., Hasch, B. G., Sommerer, F., Naumann, J., Jäkel, O., Haberer, T., & Debus, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/12/3759 · Cited by 221
Bragg Peak Proton Beam Therapy for Arteriovenous Malformation of the Brain
Kjellberg, R. N., Davis, K. R., Lyons, S., Butler, W., & Adams, R. D. (1984) · Neurosurgery · doi:10.1093/neurosurgery/31.cn_suppl_1.248 · Cited by 218
Physics Settings for Using the Geant4 Toolkit in Proton Therapy
Zacharatou Jarlskog, C., & Paganetti, H. (2008) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.922816 · Cited by 216
Self-citationSecondary neutrons in clinical proton radiotherapy: A charged issue
Brenner, D. J., & Hall, E. J. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.12.003 · Cited by 206
Space radiation protection: Destination Mars
Durante, M. (2014) · Life Sciences in Space Research · doi:10.1016/j.lssr.2014.01.002 · Cited by 202 · cited 3×
“…which may open new scenarios in CPT and provide novel biology-guided applications in the clinics: examples are the sensitivity of cancer stem cells, hypoxia, genetic background, angiogenesis and vascular damage, combination of particles and drugs (chemotherapy or immunotherapy) etc (Durante 2014a).”
BackgroundSelf-citationProton range verification through prompt gamma-ray spectroscopy
Verburg, J. M., & Seco, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7089 · Cited by 201
Kellerer, A. M. (1970) · Cited by 198
Abrasion-ablation in reactions between relativistic heavy ions
Hüfner, J., Schäfer, K., & Schürmann, B. (1975) · Physical Review C · doi:10.1103/physrevc.12.1888 · Cited by 188
Slater, J. M., Archambeau, J. O., Miller, D. W., Notarus, M. I., Preston, W., & Slater, J. D. (1992) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(92)90058-p · Cited by 186
Nuclear Data for Neutron and Proton Radiotherapy and for Radiation Protection
Schulte, R. W. (2001) · Radiation Research · doi:10.1667/0033-7587(2001)156[0223:]2.0.co;2 · Cited by 185
GPU-based fast Monte Carlo dose calculation for proton therapy
Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7783 · Cited by 177
Self-citationAccurate universal parameterization of absorption cross sections
Tripathi, R. K., Cucinotta, F. A., & Wilson, J. W. (1996) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(96)00331-x · Cited by 177
Sethi, R. V., Shih, H. A., Yeap, B. Y., Mouw, K. W., Petersen, R., Kim, D. Y., Munzenrider, J. E., Grabowski, E., Rodriguez‐Galindo, C., Yock, T. I., et al. (2014) · Cancer · doi:10.1002/cncr.28387 · Cited by 174
Yu, J. B., Soulos, P. R., Herrin, J., Cramer, L. D., Potosky, A. L., Roberts, K. B., & Gross, C. P. (2013) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djs463 · Cited by 173
Guidelines for preclinical and early phase clinical assessment of novel radiosensitisers
Harrington, K. J., Billingham, L. J., Brunner, T. B., Burnet, N. G., Chan, C. S., Hoskin, P., Mackay, R. I., Maughan, T. S., Macdougall, J., McKenna, W. G., et al. (2011) · British Journal of Cancer · doi:10.1038/bjc.2011.240 · Cited by 170
Guan, F., Bronk, L., Titt, U., Lin, S. H., Mirkovic, D., Kerr, M. D., Zhu, X. R., Dinh, J., Sobieski, M., Stephan, C., et al. (2015) · Scientific Reports · doi:10.1038/srep09850 · Cited by 167
Kill-painting of hypoxic tumours in charged particle therapy
Tinganelli, W., Durante, M., Hirayama, R., Krämer, M., Maier, A., Kraft-Weyrather, W., Furusawa, Y., Friedrich, T., & Scifoni, E. (2015) · Scientific Reports · doi:10.1038/srep17016 · Cited by 167
Self-citationDose quantification from in-beam positron emission tomography
Enghardt, W., Parodi, K., Crespo, P., Fiedler, F., Pawelke, J., & Pönisch, F. (2004) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(04)80024-0 · Cited by 163
Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
Böhlen, T. T., Cerutti, F., Dosanjh, M., Ferrari, A., Gudowska, I., Mairani, A., & Quesada, J. M. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/19/014 · Cited by 162
What will it take for laser driven proton accelerators to be applied to tumor therapy?
Linz, U., & Alonso, J. (2007) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.10.094801 · Cited by 161
Influence of fragment reaction of relativistic heavy charged particles on heavy-ion radiotherapy
Matsufuji, N., Fukumura, A., Komori, M., Kanai, T., & Kohno, T. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/309 · Cited by 153
Smith, A. R. (2009) · Medical Physics · doi:10.1118/1.3058485 · Cited by 151
Jiang, H., Wang, B., Xu, X. G., Suit, H. D., & Paganetti, H. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/18/007 · Cited by 150
Self-citationPromise and Pitfalls of Heavy-Particle Therapy
Митин, Т., & Zietman, A. L. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2014.55.1945 · Cited by 149
Tseung, H. W. C., Ma, J., & Beltran, C. J. (2015) · Medical Physics · doi:10.1118/1.4921046 · Cited by 141
Accurate universal parameterization of absorption cross sections III – light systems
Tripathi, R. K., Cucinotta, F. A., & Wilson, J. W. (1999) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(99)00479-6 · Cited by 136
Bom, V. R., Joulaeizadeh, L., & Beekman, F. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/297 · Cited by 136
Results of heavy ion radiotherapy
Castro, J. R. (1995) · Radiation and Environmental Biophysics · doi:10.1007/bf01210545 · Cited by 131
The modelling of positron emitter production and PET imaging during carbon ion therapy
Pönisch, F., Parodi, K., Hasch, B. G., & Enghardt, W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/002 · Cited by 130
Outcomes of proton therapy for patients with functional pituitary adenomas
Wattson, D. A., Tanguturi, S. K., Spiegel, D. Y., Niemierko, A., Biller, B. M. K., Nachtigall, L. B., Bussière, M. R., Swearingen, B., Chapman, P. H., Loeffler, J. S., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.06.068 · Cited by 125
Galland-Girodet, S., Pashtan, I. M., MacDonald, S. M., Ancukiewicz, M., Hirsch, A. E., Kachnic, L. A., Specht, M. C., Gadd, M. A., Smith, B. L., Powell, S. N., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.04.008 · Cited by 124
Tommasino, F., Scifoni, E., & Durante, M. (2015) · International Journal of Particle Therapy · doi:10.14338/ijpt-15-00027.1 · Cited by 124
Self-citationDegradation of the Bragg peak due to inhomogeneities
Urie, M. M., Goitein, M., Holley, W. R., & Chen, G. T. Y. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/1/001 · Cited by 123
New challenges in high-energy particle radiobiology
Durante, M. (2014) · The British Journal of Radiology · doi:10.1259/bjr.20130626 · Cited by 123
Self-citationJarlskog, C. Z., & Paganetti, H. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.04.069 · Cited by 121
Self-citationWouters, B. G., Lam, G. K. Y., Oelfke, U., et al. (1996) · Radiation Research · doi:10.2307/3579588 · Cited by 120
Grün, R., Friedrich, T., Elsässer, T., Krämer, M., Zink, K., Karger, C. P., Durante, M., Engenhart‐Cabillic, R., & Scholz, M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7261 · Cited by 119
Self-citationDose-Escalation Study for Cardiac Radiosurgery in a Porcine Model
Blanck, O., Bode, F., Gebhard, M., Hunold, P., Brandt, S., Bruder, R., Großherr, M., Vonthein, R., Rades, D., & Dunst, J. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.02.036 · Cited by 117
Helium ions for radiotherapy? Physical and biological verifications of a novel treatment modality
Krämer, M., Scifoni, E., Schuy, C., Rovituso, M., Tinganelli, W., Maier, A., Kaderka, R., Kraft‐Weyrather, W., Brons, S., Tessonnier, T., et al. (2016) · Medical Physics · doi:10.1118/1.4944593 · Cited by 115
Self-citationMorris, C. L., King, N. S. P., Kwiatkowski, K., Mariam, F. G., Merrill, F. E., & Saunders, A. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/4/046301 · Cited by 112
A single-ring OpenPET enabling PET imaging during radiotherapy
Tashima, H., Yamaya, T., Yoshida, E., Kinouchi, S., Watanabe, M., & Tanaka, E. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/14/4705 · Cited by 111
Suit, H. D., Kooy, H. M., Trofimov, A. V., Farr, J. B., Munzenrider, J. E., DeLaney, T. F., Loeffler, J. S., Clasie, B., Safai, S., & Paganetti, H. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.12.024 · Cited by 111
Self-citationSimulation of prompt gamma-ray emission during proton radiotherapy
Verburg, J., Shih, H. A., & Seco, J. C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5459 · Cited by 111
Roelofs, E., Engelsman, M., Rasch, C. R. N., Persoon, L. C. G. G., Qamhiyeh, S., Ruysscher, D. D., Verhaegen, F., Pijls-Johannesma, M. C. G., & Lambin, P. (2011) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31823529fc · Cited by 107
Scifoni, E., Tinganelli, W., Weyrather, W. K., Durante, M., Maier, A., & Krämer, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/3871 · Cited by 106
Self-citationDepth absorbed dose and LET distributions of therapeutic , , , and beams
Kempe, J., GUDOWSKA, I., & Brahme, A. (2006) · Medical Physics · doi:10.1118/1.2400621 · Cited by 105
Systematic Review: Charged-Particle Radiation Therapy for Cancer
Terasawa, T., Dvorak, T., Ip, S., Raman, G., Lau, J., & Trikalinos, T. A. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-8-200910200-00145 · Cited by 104
Mairani, A., Brons, S., Cerutti, F., Fassò, A., Ferrari, A., Krämer, M., Parodi, K., Scholz, M., & Sommerer, F. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/006 · Cited by 104
Jarlskog, C. Z., Lee, C., Bolch, W. E., Xu, X. G., & Paganetti, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/3/012 · Cited by 101
Self-citationPartial Breast Radiation Therapy With Proton Beam: 5-Year Results With Cosmetic Outcomes
Bush, D. A., Do, S., Lum, S. S., Garberoglio, C. A., Mirshahidi, H., Patyal, B. R., Grove, R. I., & Slater, J. D. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.1308 · Cited by 100
Interaction vertex imaging (IVI) for carbon ion therapy monitoring: a feasibility study
Henriquet, P., Testa, É., Chevallier, M., Dauvergne, D., Dedes, G., Freud, N., Krimmer, J., Létang, J. M., Ray, C., Richard, M.-H., et al. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/14/4655 · Cited by 99
Chao, T., Bozkurt, A., & Xu, X. G. (2001) · Health Physics · doi:10.1097/00004032-200108000-00010 · Cited by 98
Cuaron, J. J., Chon, B. H., Tsai, H. K., Goenka, A., DeBlois, D., Ho, A. Y., Powell, S. N., Hug, E. B., & Cahlon, O. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.01.005 · Cited by 97
Assessment of potential advantages of relevant ions for particle therapy: A model based study
Grün, R., Friedrich, T., Krämer, M., Zink, K., Durante, M., Engenhart‐Cabillic, R., & Scholz, M. (2015) · Medical Physics · doi:10.1118/1.4905374 · Cited by 92
Self-citationLin, L. L., Vennarini, S., Dimofte, A., Ravanelli, D., Shillington, K., Batra, S., Tochner, Z. A., Both, S., & Freedman, G. M. (2015) · Acta Oncologica · doi:10.3109/0284186x.2015.1011756 · Cited by 89
Energy loss of 70 MeV protons in elements
Bischel, H., & Hiraoka, T. (1992) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(92)95995-4 · Cited by 89
Steinsträter, O., Grün, R., Scholz, U., Friedrich, T., Durante, M., & Scholz, M. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2012.01.038 · Cited by 88
Self-citationCardiac Radiosurgery for Malignant Ventricular Tachycardia
Cvek, J., Neuwirth, R., Knybel, L., Molenda, L., Otahal, B., Pindor, J., Murárová, M., Kodaj, M., Fiala, M., Branny, M., et al. (2014) · Cureus · doi:10.7759/cureus.190 · Cited by 88
Zheng, Y., Fontenot, J. D., Taddei, P. J., Mirković, D., & Newhauser, W. D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/013 · Cited by 86
Belkić, D. (2010) · Journal of Mathematical Chemistry · doi:10.1007/s10910-010-9662-x · Cited by 85
ROMANO, F., Cirrone, G. A. P., Cuttone, G., Rosa, F. D., Mazzaglia, S. E., Petrović, I., Ristic‐Fira, A., & Varisano, A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2863 · Cited by 85
Polster, L., Schuemann, J., Rinaldi, I., Burigo, L. N., McNamara, A. L., Stewart, R. D., Attili, A., Carlson, D. J., Sato, T., Ramos‐Méndez, J., et al. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/13/5053 · Cited by 84
Self-citationProgress and controversies: Radiation therapy for prostate cancer
Martin, N. E., & D'Amico, A. V. (2014) · CA A Cancer Journal for Clinicians · doi:10.3322/caac.21250 · Cited by 83
Assessment of out‐of‐field absorbed dose and equivalent dose in proton fields
Clasie, B., Wroe, A. J., Kooy, H. M., Depauw, N., Flanz, J., Paganetti, H., & Rosenfeld, A. B. (2009) · Medical Physics · doi:10.1118/1.3271390 · Cited by 82
Self-citationFontenot, J. D., Taddei, P. J., Zheng, Y., Mirković, D., Jordan, T., & Newhauser, W. D. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/6/012 · Cited by 79
Emfietzoglou, D., Garcia‐Molina, R., Kyriakou, I., Abril, I., & Nikjoo, H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/012 · Cited by 75
Athar, B. S., Bednarz, B. P., Seco, J. C., Hancox, C., & Paganetti, H. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/10/006 · Cited by 70
Self-citationvan Goethem, M. J., van der Meer, R., Reist, H. W., & Schippers, J. M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/011 · Cited by 69
Towards Achieving the Full Clinical Potential of Proton Therapy by Inclusion of LET and RBE Models
Jones, B. (2015) · Cancers · doi:10.3390/cancers7010460 · Cited by 68
Specification of Carbon Ion Dose at the National Institute of Radiological Sciences (NIRS)
Matsufuji, N., Kanai, T., Kanematsu, N., et al. (2007) · Journal of Radiation Research · doi:10.1269/jrr.48.a81 · Cited by 67
Kocher, D. C., Apostoaei, A. I., & Hoffman, F. O. (2005) · Health Physics · doi:10.1097/01.hp.0000154172.48895.45 · Cited by 66
Ion-induced electron production in tissue-like media and DNA damage mechanisms
Surdutovich, E., Obolensky, O. I., Scifoni, E., Pshenichnov, I., Mishustin, I. N., Solov’yov, A. V., & Greiner, W. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2008-00207-y · Cited by 66
Bone models for use in radiotherapy dosimetry
WOODARD, H. Q., & White, D. R. (1982) · British Journal of Radiology · doi:10.1259/0007-1285-55-652-277 · Cited by 65
Absolute prompt-gamma yield measurements for ion beam therapy monitoring
Pinto, M., Bajard, M., Brons, S., Chevallier, M., Dauvergne, D., Dedes, G., Rydt, M. D., Freud, N., Krimmer, J., Tessa, C. L., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/565 · Cited by 64
Interaction vertex imaging (IVI) for carbon ion therapy monitoring: a feasibility study
Testa, É., Dauvergne, D., Dedes, G., Freud, N., Henriquet, P., Krimmer, J., Létang, J. M., Ray, C. D., Richard, M. H., & Sauli, F. (2012) · HAL · Cited by 64
Design study of anin situPET scanner for use in proton beam therapy
Surti, S., Zou, W., Daube-Witherspoon, M. E., McDonough, J. E., & Karp, J. S. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/9/002 · Cited by 63
Energy Straggling of Heavy Charged Particles in Thick Absorbers
Payne, M. G. (1969) · Physical Review · doi:10.1103/physrev.185.611 · Cited by 62
Characterizing the response of miniature scintillation detectors when irradiated with proton beams
Archambault, L., Polf, J., Beaulieu, L., & Beddar, S. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/7/004 · Cited by 61
Monte Carlo investigation of the low-dose envelope from scanned proton pencil beams
Sawakuchi, G. O., Titt, U., Mirković, D., Ciangaru, G., Zhu, X., Sahoo, N., Gillin, M. T., & Mohan, R. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/3/011 · Cited by 61
Taddei, P. J., Fontenot, J. D., Zheng, Y., Mirković, D., Lee, A. K., Titt, U., & Newhauser, W. D. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/8/009 · Cited by 60
Particle therapy for noncancer diseases
Bert, C., Engenhart‐Cabillic, R., & Durante, M. (2012) · Medical Physics · doi:10.1118/1.3691903 · Cited by 59
Self-citationBarendsen, G. W. (1994) · International Journal of Radiation Biology · doi:10.1080/09553009414551411 · Cited by 58
Validation of a GPU-based Monte Carlo code (gPMC) for proton radiation therapy: clinical cases study
Giantsoudi, D., Schuemann, J., Jia, X., Dowdell, S., Jiang, S. B., & Paganetti, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/6/2257 · Cited by 58
Self-citationPshenichnov, I., Mishustin, I. N., & Greiner, W. (2008) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2008.02.025 · Cited by 56
Chung, C. S., Keating, N. L., Yock, T. I., & Tarbell, N. J. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.06.785 · Cited by 56
Lehmann, H. I., Richter, D., Prokesch, H., Graeff, C., Prall, M., Simoniello, P., Fournier, C., Bauer, J., Kaderka, R., Weymann, A., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.002436 · Cited by 56
Self-citationBozkurt, A., Chao, T., Xu, X., Bozkurt, A., & Chao, T. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/10/321 · Cited by 55
Srdoč, D. (1981) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/s0020-708x(81)81016-2 · Cited by 52
Practical considerations in the calibration of CT scanners for proton therapy
Ainsley, C. G., & Yeager, C. (2014) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v15i3.4721 · Cited by 52
Sørensen, B. S., Horsman, M. R., Alsner, J., Overgaard, J., Durante, M., Scholz, M., Friedrich, T., & Bassler, N. (2015) · Acta Oncologica · doi:10.3109/0284186x.2015.1069890 · Cited by 52
Self-citationDosimetry techniques for narrow proton beam radiosurgery
Vatnitsky, S. M., Miller, D. W., Moyers, M. F., Levy, R. P., Schulte, R. W., Slater, J. D., & Slater, J. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/308 · Cited by 52
Elie, N., Kaliski, A., PERONNEAU, P., Opolon, P., Roche, A. J., & Lassau, N. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.09.011 · Cited by 52
Lee, D., Nam, W. H., Lee, J. Y., & Ra, J. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/008 · Cited by 51
Bozkurt, A., Chao, T., & Xu, X. (2001) · Health Physics · doi:10.1097/00004032-200108000-00011 · Cited by 49
Evaluation of integrated respiratory gating systems on a Novalis Tx system
Chang, Z., Liu, T., Cai, J., Chen, Q., Wang, Z., & Yin, F.-F. (2011) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v12i3.3495 · Cited by 48
Athar, B. S., & Paganetti, H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/005 · Cited by 48
Self-citationOverview of recent advances in treatment planning for ion beam radiotherapy
Krämer, M., Scifoni, E., Schmitz, F., Sokol, O., & Durante, M. (2014) · The European Physical Journal D · doi:10.1140/epjd/e2014-40843-x · Cited by 48
Self-citationSingle-Fraction Proton Beam Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations
Hattangadi-Gluth, J. A., Chapman, P. H., Kim, D., Niemierko, A., Bussière, M. R., Stringham, A., Daartz, J., Ogilvy, C. S., Loeffler, J. S., & Shih, H. A. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.02.030 · Cited by 45
Toppi, M., Abou-Haïdar, Z., Agodi, C., Álvarez, M. A. G., Aumann, T., Balestra, F., Battistoni, G., Bocci, A., Böhlen, T. T., Boudard, A., et al. (2016) · Physical Review C · doi:10.1103/physrevc.93.064601 · Cited by 45
Self-citationDedes, G., Pinto, M., Dauvergne, D., Freud, N., Krimmer, J., Létang, J. M., Ray, C. D., & Testa, É. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/7/1747 · Cited by 44
Pleskac, R., Abou-Haïdar, Z., Agodi, C., Álvarez, M. A. G., Aumann, T., Battistoni, G., Bocci, A., Böhlen, T. T., Boudard, A., Brunetti, A., et al. (2012) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2012.02.020 · Cited by 42
Self-citationRecent Developments in Pre-Equilibrium and De-Excitation Models in Geant4
Quesada, J. M., Ivanchenko, V., Ivanchenko, A., Cortés-Giraldo, M. A., Folger, G., HOWARD, A., & Wright, D. H. (2011) · Progress in Nuclear Science and Technology · doi:10.15669/pnst.2.936 · Cited by 41
Combs, S. E., & Debus, J. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.818254 · Cited by 41
Tessa, C. L., Berger, T., Kaderka, R., Schardt, D., Körner, C., Ramm, U., Licher, J., Matsufuji, N., Dahlgren, C. V., Lomax, A., et al. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.04.004 · Cited by 40
Self-citationSaager, M., Glowa, C., Peschke, P., Brons, S., Grün, R., Scholz, M., Huber, P. E., Debus, J., & Karger, C. P. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.07.006 · Cited by 39
Laser-Driven Particle Accelerators
Dunne, M. (2006) · Science · doi:10.1126/science.1126051 · Cited by 39
Liu, T., Zhou, J., Yoshida, E. J., Woodhouse, S. A., Schiff, P. B., Wang, T. J. C., Lu, Z. F., Pile‐Spellman, E., Zhang, P., & Kutcher, G. J. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.08.071 · Cited by 39
Universal Parameterization of Absorption Cross Sections
Tripathi, R. K., Cucinotta, F. A., & Wilson, J. W. (1997) · NASA Technical Reports Server (NASA) · Cited by 36
Technologies for delivery of proton and ion beams for radiotherapy
Owen, H. L., Holder, D., Alonso, J., & Mackay, R. I. (2014) · International Journal of Modern Physics A · doi:10.1142/s0217751x14410024 · Cited by 36
Brusasco, C., Voss, B., Schardt, D., Krämer, M., & Kraft, G. (2000) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(00)00058-6 · Cited by 36
A comparison of total reaction cross section models used in particle and heavy ion transport codes
Sihver, L., Lantz, M., Takechi, M., Kohama, A., FERRARI, A., Cerutti, F. M., & Sato, T. (2012) · Advances in Space Research · doi:10.1016/j.asr.2011.11.029 · Cited by 35
High-energy proton imaging for biomedical applications
Prall, M., Durante, M., Berger, T., Przybyla, B., Graeff, C., Lang, P.-M., LaTessa, C., Shestov, L. M., Simoniello, P., Danly, C. R., et al. (2016) · Scientific Reports · doi:10.1038/srep27651 · Cited by 35
Self-citationShielding design for a laser-accelerated proton therapy system
Fan, J., Luo, W., Fourkal, E., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/13/017 · Cited by 34
Biological effects of proton radiation: an update: Figure 1.
Girdhani, S., Sachs, R. K., & Hlatky, L. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv178 · Cited by 29
Modeling Combined Chemotherapy and Particle Therapy for Locally Advanced Pancreatic Cancer
Durante, M., Tommasino, F., & Yamada, S. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00145 · Cited by 28
Self-citationTherapeutic techniques applied in the heavy-ion therapy at IMP
Li, Q., & Sihver, L. (2011) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2011.01.125 · Cited by 27
Mirsch, J., Tommasino, F., Frohns, A., Conrad, S., Durante, M., Scholz, M., Friedrich, T., & Löbrich, M. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508702112 · Cited by 24
Self-citationFirst biological images with high-energy proton microscopy
Varentsov, D., Bogdanov, A. V., Demidov, V. S., Golubev, A. A., Канцырев, А. В., Lang, P.-M., Nikolaev, D. N., Маrkov, N. V., Natale, F., Shestov, L. M., et al. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.03.002 · Cited by 23
Self-citationControversies in Clinical Trials in Proton Radiotherapy: The Present and the Future
Miller, R. C., Lodge, M., Murad, M. H., & Jones, B. (2013) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2012.11.004 · Cited by 22
Borge, M. J. G. (2014) · Nuclear Physics News · doi:10.1080/10619127.2014.912054 · Cited by 21
Protective effect of transparent film dressing on proton therapy induced skin reactions
Whaley, J. T., Kirk, M. L., Cengel, K. A., McDonough, J. E., Bekelman, J. E., & Christodouleas, J. P. (2013) · Radiation Oncology · doi:10.1186/1748-717x-8-19 · Cited by 21
Optimizing Normal Tissue Sparing in Ion Therapy Using Calculated Isoeffective Dose for Ion Selection
Remmes, N. B., Herman, M., & Kruse, J. J. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.08.006 · Cited by 21
Test of weak and strong factorization in nucleus–nucleus collisions at several hundred MeV/nucleon
Tessa, C. L., Sihver, L., Zeitlin, C. J., Miller, J., Guetersloh, S., Heilbronn, L., Mancusi, D., Iwata, Y., & Murakami, T. (2007) · Nuclear Physics A · doi:10.1016/j.nuclphysa.2007.04.016 · Cited by 17
Neutron-fluence-to-dose conversion coefficients in an anthropomorphic phantom
Alghamdi, A. A., Ma, A. K., Tzortzis, M., & Spyrou, N. M. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nci268 · Cited by 17
Stochastics of Energy Loss and Biological Effects of Heavy Ions in Radiation Therapy
Bichsel, H. (2013) · Advances in quantum chemistry · doi:10.1016/b978-0-12-396455-7.00001-7 · Cited by 14
Towards Proton Therapy and Radiography at FAIR
Prall, M., Lang, P.-M., LaTessa, C., Mariam, F. G., Merrill, F. E., Shestov, L. M., Simoniello, P., Varentsov, D., & Durante, M. (2015) · Journal of Physics Conference Series · doi:10.1088/1742-6596/599/1/012041 · Cited by 6
Self-citation
Cited by
Charged-particle therapy in cancer: clinical uses and future perspectives
Durante, M., Orecchia, R., & Loeffler, J. S. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.30 · Cited by 484
Self-citationTowards clinical translation of FLASH radiotherapy
Vozenin, M.-C., Bourhis, J., & Durante, M. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00697-z · Cited by 363
Self-citationTinganelli, W., & Durante, M. (2020) · Cancers · doi:10.3390/cancers12103022 · Cited by 267
Self-citationDense nuclear matter equation of state from heavy-ion collisions
Sorensen, A., Agarwal, K., Brown, K. W., Chajęcki, Z., Danielewicz, P., Drischler, C., Gandolfi, S., Holt, J. W., Kaminski, M., Ko, C.-M., et al. (2024) · Progress in Particle and Nuclear Physics · doi:10.1016/j.ppnp.2023.104080 · Cited by 185
All the fun of the FAIR: fundamental physics at the facility for antiproton and ion research
Durante, M., Indelicato, P., Jonson, B., Koch, V, Langanke, K., Meißner, U.-G., Nappi, E., Nilsson, T., Stöhlker, T., Widmann, E., et al. (2019) · Physica Scripta · doi:10.1088/1402-4896/aaf93f · Cited by 129
Self-citation
Metadata
- Authors
- Durante, M., & Paganetti, H.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2016-08-19
- Volume
- 79
- Issue
- 9
- Pages
- 096702
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2509332681
- Cited by
- 345
- References
- 184
- FWCI
- 22.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.