Wrist accelerometers are being used in population level surveillance of physical activity (PA) but more research is needed to evaluate their validity for correctly classifying types of PA behavior and predicting energy expenditure (EE). In this study we compare accelerometers worn on the wrist and hip, and the added value of heart rate (HR) data, for predicting PA type and EE using machine learning. Forty adults performed locomotion and household activities in a lab setting while wearing three ActiGraph GT3X+ accelerometers (left hip, right hip, non-dominant wrist) and a HR monitor (Polar RS400). Participants also wore a portable indirect calorimeter (COSMED K4b2), from which EE and metabolic equivalents (METs) were computed for each minute. We developed two predictive models: a random forest classifier to predict activity type and a random forest of regression trees to estimate METs. Predictions were evaluated using leave-one-user-out cross-validation. The hip accelerometer obtained an average accuracy of 92.3% in predicting four activity types (household, stairs, walking, running), while the wrist accelerometer obtained an average accuracy of 87.5%. Across all 8 activities combined (laundry, window washing, dusting, dishes, sweeping, stairs, walking, running), the hip and wrist accelerometers obtained average accuracies of 70.2% and 80.2% respectively. Predicting METs using the hip or wrist devices alone obtained root mean square errors (rMSE) of 1.09 and 1.00 METs per 6 min bout, respectively. Including HR data improved MET estimation, but did not significantly improve activity type classification. These results demonstrate the validity of random forest classification and regression forests for PA type and MET prediction using accelerometers. The wrist accelerometer proved more useful in predicting activities with significant arm movement, while the hip accelerometer was superior for predicting locomotion and estimating EE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, several studies used a large number of variables for the application of machine learning techniques, with (45), (46), and (47) reporting the use of 117, 112, and 45 features, respectively.”
From A quantitative analysis of fidgeting in ADHD and its relation to performance and sustained attention on a cognitive task (2024) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
(1985) · Europe PMC (PubMed Central) · Cited by 9,143
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147 · cited 2×
“…have been found to be effective for measurement of PA (Esliger et al 2011, Kinnunen et al 2012), but previous studies have found a wrist-worn accelerometer to be less accurate than a hip-worn accelerometer for predicting PA (Bao and Intille 2004, Atallah et al 2011, Mannini et al 2013).”
Cappuccio, F. P., Cooper, D., D'Elia, L., Strazzullo, P., & Miller, M. A. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr007 · Cited by 2,146
Real-time human pose recognition in parts from single depth images
Shotton, J., Sharp, T., Kipman, A., Fitzgibbon, A., Finocchio, M., Blake, A., Cook, M., & Moore, R. (2013) · Communications of the ACM · doi:10.1145/2398356.2398381 · Cited by 2,044
Activity recognition from accelerometer data
Ravi, N., Dandekar, N., Mysore, P., & Littman, M. L. (2005) · Innovative Applications of Artificial Intelligence · Cited by 1,818
Hamilton, M. T., Hamilton, D. G., & Zderic, T. W. (2007) · Diabetes · doi:10.2337/db07-0882 · Cited by 1,655
Is physical activity or physical fitness more important in defining health benefits?
BLAIR, S. N., CHENG, Y., & SCOTT HOLDER, J. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106001-00007 · Cited by 1,118
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 1×
“Wrist-worn accelerometers have been found to be effective for measurement of PA (Esliger et al 2011, Kinnunen et al 2012), but previous studies have found a wrist-worn accelerometer to be less accurate than a hip-worn accelerometer for predicting PA (Bao and Intille 2004, Atallah et al 2011,…”
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Resistance Exercise Training: Its Role in the Prevention of Cardiovascular Disease
Braith, R. W., & Stewart, K. J. (2006) · Circulation · doi:10.1161/circulationaha.105.584060 · Cited by 491
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473 · cited 3×
“Keywords: heart rate, machine learning, random forest (Some figures may appear in colour only in the online journal)”
Tapia, E. M., Intille, S. S., Haskell, W., Larson, K., Wright, J., King, A., & Friedman, R. (2007) · 2007 11th IEEE International Symposium on Wearable Computers · doi:10.1109/iswc.2007.4373774 · Cited by 458
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Energy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry
Spurr, G., Prentice, A., Murgatroyd, P., Goldberg, G., Reina, J., & Christman, N. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.3.552 · Cited by 414
Activity Recognition Using a Single Accelerometer Placed at the Wrist or Ankle
MANNINI, A., INTILLE, S. S., ROSENBERGER, M., SABATINI, A. M., & HASKELL, W. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829736d6 · Cited by 383 · cited 5×
“This is a novel result with respect to previous studies that found the wrist position sub-optimal for EE estimation (e.g. Mannini et al 2013), and we believe is due to the random forest’s ability to model highly nonlinear patterns in the data.”
InfluentialStaudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
Sensor Positioning for Activity Recognition Using Wearable Accelerometers
Atallah, L., Lo, B., King, R., & Yang, G.-Z. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2160540 · Cited by 346
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Measuring daily behavior using ambulatory accelerometry: The Activity Monitor
Bussmann, J. B. J., Martens, W. L. J., Tulen, J. H. M., Schasfoort, F. C., van den Berg-Emons, H. J. G., & Stam, H. J. (2001) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03195388 · Cited by 315
JEBB, S. A., & MOORE, M. S. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199911001-00008 · Cited by 314
Evaluation of methods to assess physical activity in free-living conditions
J. M. LEENDERS, N. Y., MICHAEL SHERMAN, W., NAGARAJA, H. N., & LAWRENCE KIEN, C. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200107000-00024 · Cited by 255
Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a24536 · Cited by 245
Validity of Four Short Physical Activity Questionnaires in Middle-Aged Persons
MäDER, U., MARTIN, B. W., SCHUTZ, Y., & MARTI, B. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000227310.18902.28 · Cited by 239
Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f0d9c · Cited by 237
Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233 · cited 2×
“The feature vector contained a variety of time- and frequency-domain statistics that are commonly used in analysis of raw accelerometer signals (Bao and Intille 2004, Staudenmayer et al 2009, Zhang et al 2012, K Ellis et al Physiol.”
Livingstone, M., Prentice, A., Coward, W., Ceesay, S., Strain, J., McKenna, P., Nevin, G., Barker, M., & Hickey, R. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/52.1.59 · Cited by 231
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Varun Kumar, Y. V. B., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Using gravity to estimate accelerometer orientation
Mizell, D. (2004) · Seventh IEEE International Symposium on Wearable Computers, 2003. Proceedings. · doi:10.1109/iswc.2003.1241424 · Cited by 212
Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00150.2009 · Cited by 196
Gyllensten, I. C., & Bonomi, A. G. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160723 · Cited by 183
Improving Energy Expenditure Estimation for Physical Activity
ZHANG, K., PI-SUNYER, F. X., & BOOZER, C. N. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126585.40962.22 · Cited by 180
Using the SenseCam to Improve Classifications of Sedentary Behavior in Free-Living Settings
Kerr, J., Marshall, S. J., Godbole, S., Chen, J., Legge, A., Doherty, A. R., Kelly, P., Oliver, M., Badland, H. M., & Foster, C. (2013) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2012.11.004 · Cited by 177
Self-citationA Timely Meeting: Objective Measurement of Physical Activity
TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185473.32846.c3 · Cited by 176
Refined Two-Regression Model for the ActiGraph Accelerometer
CROUTER, S. E., KUFFEL, E., HAAS, J. D., FRONGILLO, E. A., & BASSETT, D. R. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c37458 · Cited by 176
Validity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers
Rothney, M. P., Schaefer, E. V., Neumann, M. M., Choi, L., & Chen, K. Y. (2008) · Obesity · doi:10.1038/oby.2008.279 · Cited by 175
Data-based Approach for Developing a Physical Activity Frequency Questionnaire
Bernstein, M., Sloutskis, D., Kumanyika, S., Sparti, A., Schutz, Y., & Morabia, A. (1998) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009427 · Cited by 157
Schoeller, D. A., & Hnilicka, J. M. (1996) · PubMed · Cited by 146
Simultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134
Using wearable activity type detection to improve physical activity energy expenditure estimation
Albinali, F., Intille, S., Haskell, W., & Rosenberger, M. (2010) · Proceedings of the 12th ACM international conference on Ubiquitous computing · doi:10.1145/1864349.1864396 · Cited by 130
Ellis, K., Godbole, S., Marshall, S., Lanckriet, G., Staudenmayer, J., & Kerr, J. (2014) · Frontiers in Public Health · doi:10.3389/fpubh.2014.00036 · Cited by 123 · cited 3×
“Preliminary experiments showed that random forests achieved the highest accuracy compared to several other popular machine learning algorithms (e.g. support vector machines, k nearest neighbour, neural networks) (Ellis et al 2014).”
MethodSelf-citationPredicting Energy Expenditure of Physical Activity Using Hip- and Wrist-Worn Accelerometers
Chen, K. Y., Acra, S. A., Majchrzak, K., Donahue, C. L., Baker, L., Clemens, L., Sun, M., & Buchowski, M. S. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322641088 · Cited by 116
Predicting Energy Expenditure from Accelerometry Counts in Adolescent Girls
SCHMITZ, K. H., TREUTH, M., HANNAN, P., MCMURRAY, R., RING, K. B., CATELLIER, D., & PATE, R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000150084.97823.f7 · Cited by 114
A critical evaluation of heart rate monitoring to assess energy expenditure in individuals
Li, R., Deurenberg, P., & Hautvast, J. (1993) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.5.602 · Cited by 112
Exiting the Cleanroom: On Ecological Validity and Ubiquitous Computing
Carter, S., Mankoff, J., Klemmer, S. R., & Matthews, T. (2008) · Human–Computer Interaction · doi:10.1080/07370020701851086 · Cited by 107
Device-based monitoring in physical activity and public health research
Bassett, D. R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1769 · Cited by 105
Measuring human energy expenditure: What have we learned from the flex‐heart rate method?
Leonard, W. R. (2003) · American Journal of Human Biology · doi:10.1002/ajhb.10187 · Cited by 103
Estimating energy expenditure by heart-rate monitoring without individual calibration
RENNIE, K. L., HENNINGS, S. J., MITCHELL, J., & WAREHAM, N. J. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106000-00013 · Cited by 98
Real-time Daily Activity Classification with Wireless Sensor Networks using Hidden Markov Model
He, J., Li, H., & Tan, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353008 · Cited by 86
A combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83
Validated caloric expenditure estimation using a single body-worn sensor
Lester, J., Hartung, C., Pina, L. R., Libby, R., Borriello, G., & Duncan, G. E. (2009) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/1620545.1620579 · Cited by 79
Validation of Actigraph accelerometer estimates of total energy expenditure in young children
Reilly, J. J., Kelly, L. A., Montgomery, C., Jackson, D. M., Slater, C., Grant, S., & Paton, J. Y. (2006) · International Journal of Pediatric Obesity · doi:10.1080/17477160600845051 · Cited by 78
McLellan, S. A., Walsh, T. S., Burdess, A., & Lee, A. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1323-5 · Cited by 63
A new method for measurement of gas exchange during anaesthesia using an extractable marker gas
Peyton, P. J., Robinson, G. J. B., Terry, D., & Junor, P. A. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/001 · Cited by 58
Wrist-worn accelerometers in assessment of energy expenditure during intensive training
Kinnunen, H., Tanskanen, M., Kyröläinen, H., & Westerterp, K. R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1841 · Cited by 53 · cited 1×
“Wrist-worn accelerometers have been found to be effective for measurement of PA (Esliger et al 2011, Kinnunen et al 2012), but previous studies have found a wrist-worn accelerometer to be less accurate than a hip-worn accelerometer for predicting PA (Bao and Intille 2004, Atallah et al 2011,…”
He, Z., Liu, Z., Jin, L., Zhen, L.-X., & Huang, J.-C. (2008) · 2008 19th International Conference on Pattern Recognition · doi:10.1109/icpr.2008.4761688 · Cited by 52
Westerterp, K. R., & Bouten, C. V. C. (1997) · Zeitschrift für Ernährungswissenschaft · doi:10.1007/bf01617795 · Cited by 51
Experimental reliability of the doubly labeled water technique
Goran, M. I., Poehlman, E. T., & Danforth, E. (1994) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1994.266.3.e510 · Cited by 39
Energy expenditure assessed by heart rate and doubly labeled water in young athletes
EKELUND, U., YNGVE, A., WESTERTERP, K., & SJ??STR??M, M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200208000-00019 · Cited by 38
SVM-based multi-sensor fusion for free-living physical activity assessment
Liu, S., Gao, R. X., John, D., STAUDENMAYER, J. W., & Freedson, P. S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090868 · Cited by 36
A Novel Energy Expenditure Prediction Equation for Intermittent Physical Activity
DUGAS, L. R., MERWE, L. V. D., ODENDAAL, H., NOAKES, T. D., & LAMBERT, E. V. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000177742.12931.50 · Cited by 31
Ruch, N., Joss, F., Jimmy, G., Melzer, K., Hänggi, J. M., & Mäder, U. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01443.2012 · Cited by 28
Su, S. W., Celler, B. G., Savkin, A. V., Nguyen, H. T., Cheng, T. M., Guo, Y., & Wang, L. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0534-0 · Cited by 25
Physical activity recognition in free-living from body-worn sensors
Ellis, K., Godbole, S. V., Chen, J. M., Marshall, S. J., Lanckriet, G. R. G., & Kerr, J. (2013) · doi:10.1145/2526667.2526685 · Cited by 19
Self-citationJang, Y., Jung, M. W., Kang, J., & Kim, H. C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615296 · Cited by 11
Haapalainen, E., Laurinen, P., Röning, J., & Kinnunen, H. O. (2008) · International Conference on Machine Learning and Applications · doi:10.1109/icmla.2008.131 · Cited by 9
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Michie, S., Yardley, L., West, R., Patrick, K., & Greaves, F. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.7126 · Cited by 865
“Machine learning and related approaches are increasingly being used to solve big data challenges, including health behavior assessment and interventions [12].”
BackgroundLee, S., Kim, J.-C., Jung, H.-S., Lee, M. J., & Lee, S. (2017) · Geomatics, Natural Hazards and Risk · doi:10.1080/19475705.2017.1308971 · Cited by 395
An ensemble learning framework for anomaly detection in building energy consumption
Araya, D. B., Grolinger, K., ElYamany, H. F., Capretz, M. A. M., & Bitsuamlak, G. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.058 · Cited by 254
Willetts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
“For energy expenditure prediction, random forests for regression 26 perform better than linear models for wrist-worn data 22 , and we found the inclusion of activity labels reduced noise and thus further improved performance (e.g. movement is high when in a vehicle, but energy expenditure is low).”
Method
Metadata
- Authors
- Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-10-23
- Volume
- 35
- Issue
- 11
- Pages
- 2191-2203
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2002353621
- Cited by
- 344
- References
- 70
- FWCI
- 18.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.