The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Open accessAbstract
OBJECTIVE: Brain-computer interfaces (BCIs) using chronically implanted intracortical microelectrode arrays (MEAs) have the potential to restore lost function to people with disabilities if they work reliably for years. Current sensors fail to provide reliably useful signals over extended periods of time for reasons that are not clear. This study reports a comprehensive retrospective analysis from a large set of implants of a single type of intracortical MEA in a single species, with a common set of measures in order to evaluate failure modes. APPROACH: Since 1996, 78 silicon MEAs were implanted in 27 monkeys (Macaca mulatta). We used two approaches to find reasons for sensor failure. First, we classified the time course leading up to complete recording failure as acute (abrupt) or chronic (progressive). Second, we evaluated the quality of electrode recordings over time based on signal features and electrode impedance. Failure modes were divided into four categories: biological, material, mechanical, and unknown. MAIN RESULTS: Recording duration ranged from 0 to 2104 days (5.75 years), with a mean of 387 days and a median of 182 days (n = 78). Sixty-two arrays failed completely with a mean time to failure of 332 days (median = 133 days) while nine array experiments were electively terminated for experimental reasons (mean = 486 days). Seven remained active at the close of this study (mean = 753 days). Most failures (56%) occurred within a year of implantation, with acute mechanical failures the most common class (48%), largely because of connector issues (83%). Among grossly observable biological failures (24%), a progressive meningeal reaction that separated the array from the parenchyma was most prevalent (14.5%). In the absence of acute interruptions, electrode recordings showed a slow progressive decline in spike amplitude, noise amplitude, and number of viable channels that predicts complete signal loss by about eight years. Impedance measurements showed systematic early increases, which did not appear to affect recording quality, followed by a slow decline over years. The combination of slowly falling impedance and signal quality in these arrays indicates that insulating material failure is the most significant factor. SIGNIFICANCE: This is the first long-term failure mode analysis of an emerging BCI technology in a large series of non-human primates. The classification system introduced here may be used to standardize how neuroprosthetic failure modes are evaluated. The results demonstrate the potential for these arrays to record for many years, but achieving reliable sensors will require replacing connectors with implantable wireless systems, controlling the meningeal reaction, and improving insulation materials. These results will focus future research in order to create clinical neuroprosthetic sensors, as well as valuable research tools, that are able to safely provide reliable neural signals for over a decade.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous demonstrations of intracortical insertion of MEAs showed injury and neuronal loss at the implantation location99, as well as signal instabilities contributing to signal loss and performance decline over time100,101.”
From The speech neuroprosthesis (2024) · cites this paper as [100]
In the citing paper
“In spite of the formidable results of using UEA/USEA technologies described above, most penetrating microelectrode arrays currently have maximum in vivo lifetimes of several months or a few years (Suner et al 2005, Prasad et al 2012, Barrese et al 2013).”
From Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies (2016) · cites this paper as Barrese et al 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Single-neuron dynamics in human focal epilepsy
Truccolo, W., Donoghue, J., Hochberg, L. R., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Brown, E. N., Halgren, E., & Cash, S. S. (2011) · Nature Neuroscience · doi:10.1038/nn.2782 · Cited by 528
Self-citationFactors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 481
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Research works printed but not linked: 2
- McConnell G C, 2009, J. Neural Eng., 6
- Prasad A, 2012, J. Neural Eng., 9
Cited by
Sorted by citations
Items 301–400 of 599
Carbohydrate based biomaterials for neural interface applications
Dhawan, V., & Cui, X. T. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb00584k · Cited by 17
Jeakle, E. N., Abbott, J., Usoro, J. O., Wu, Y., Haghighi, P., Radhakrishna, R., Sturgill, B. S., Nakajima, S., Thai, T. T. D., Pancrazio, J. J., et al. (2023) · Micromachines · doi:10.3390/mi14030680 · Cited by 15
Smith, T. J., Wu, Y., Cheon, C., Khan, A. A., Srinivasan, H., Capadona, J. R., Cogan, S. F., Pancrazio, J. J., Engineer, C. T., & Hernandez-Reynoso, A. G. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1202258 · Cited by 14
Yan, T., Suzuki, K., Kameda, S., Maeda, M., Mihara, T., & Hirata, M. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1260675 · Cited by 19
Amorphous Silicon Carbide for Neural Interface Applications
Knaack, G. L., Charkhkar, H., Cogan, S. F., & Pancrazio, J. J. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802993-0.00008-3 · Cited by 15
Bottlenecks to clinical translation of direct brain-computer interfaces
Serruya, M. D. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00226 · Cited by 15
Oh, Y.-K., Sung, M., Kim, J. W., & Kim, H. (2024) · Materials Today Electronics · doi:10.1016/j.mtelec.2024.100104 · Cited by 14
Whitsitt, Q. A., Saxena, A., Patel, B., Evans, B. M., Hunt, B., & Purcell, E. K. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5936 · Cited by 22
Failure Modes of Implanted Neural Interfaces
Delbeke, J., Haesler, S., & Prodanov, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_6 · Cited by 16
Yan, T., Kameda, S., Suzuki, K., Kaiju, T., Inoue, M., Suzuki, T., & Hirata, M. (2020) · Sensors · doi:10.3390/s21010178 · Cited by 13
Chronic co-implantation of ultraflexible neural electrodes and a cranial window
Yin, R., Noble, B. C., He, F., Zolotavin, P., Rathore, H., Jin, Y., Sevilla, N., Xie, C., & Luan, L. (2022) · Neurophotonics · doi:10.1117/1.nph.9.3.032204 · Cited by 14
Bioinspired Structures and Design
Askarinejad, S., & Rahbar, N. (2020) · Cambridge University Press eBooks · doi:10.1017/9781139058995 · Cited by 15
Volitional control of single-electrode high gamma local field potentials by people with paralysis
Milekovic, T., Bacher, D., Sarma, A. A., Simeral, J. D., Saab, J., Pandarinath, C., Yvert, B., Sorice, B. L., Blabe, C. H., Oakley, E. M., et al. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00131.2018 · Cited by 16
Self-citationOptimizing the neuron-electrode interface for chronic bioelectronic interfacing
Keogh, C. (2020) · Neurosurgical FOCUS · doi:10.3171/2020.4.focus20178 · Cited by 14
A low-power communication scheme for wireless, 1000 channel brain–machine interfaces
Costello, J. T., Nason, S. R., An, H., Lee, J., Mender, M. J., Temmar, H., Wallace, D. M., Lim, J., Willsey, M. S., Patil, P. G., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7352 · Cited by 14
NeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13
Mueller, N. N., Ocoko, M. Y. M., Kim, Y., Li, K., Gisser, K., Glusauskas, G., Lugo, I., Dernelle, P., Hermoso, A. C., Wang, J., et al. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00440-5 · Cited by 14
Sputtered ruthenium oxide coatings for neural stimulation and recording electrodes
Chakraborty, B., Joshi‐Imre, A., Maeng, J., & Cogan, S. F. (2020) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34728 · Cited by 14
King, B. J., Read, G. J. M., & Salmon, P. M. (2023) · Applied Ergonomics · doi:10.1016/j.apergo.2023.104028 · Cited by 13
Millimeter-scale integrated and wirewound coils for powering implantable neural microsystems
Feng, P., Constandinou, T. G., Yeon, P., & Ghovanloo, M. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325184 · Cited by 13
Fabrication of Planar Microelectrode Array Using Laser-Patterned ITO and SU-8
Jeong, H. S., Hwang, S., Min, K. S., & Jun, S. B. (2021) · Micromachines · doi:10.3390/mi12111347 · Cited by 13
Kim, Y., Ereifej, E. S., Schwartzman, W. E., Meade, S. M., Chen, K., Rayyan, J., He, F., Aluri, V., Mueller, N. N., Bhambra, R., et al. (2021) · Micromachines · doi:10.3390/mi12121446 · Cited by 13
Neural Decoding and Applications in Bioelectronic Medicine
Bouton, C. E. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2014.00012 · Cited by 14
Torres-Martinez, N., Ratel, D., Crétallaz, C., Gaude, C., Maubert, S., Divoux, J., Henry, C., Guiraud, D., & Sauter-Starace, F. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3836 · Cited by 14
Stimulus-dependent spiking relationships with the EEG
Snyder, A. C., & Smith, M. A. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00427.2015 · Cited by 13
Čvančara, P., Valle, G., Müller, M., Guiho, T., Hiairrassary, A., Petrini, F., Raspopovic, S., Strauss, I., Granata, G., Fernandez, E., et al. (2019) · doi:10.1101/653964 · Cited by 12
Electrode Arrays for Detecting and Modulating Deep Brain Neural Information in Primates: A Review
Zhang, S., Song, Y., Lv, S., Jing, L., Wang, M., Liu, Y., Xu, W., Jiao, P., Zhang, S., Wang, M., et al. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0249 · Cited by 16
Electrical percolation network based on nano-cellulose template for flexible hydrogel bioelectrode
Guan, M., Han, Z., Liu, N., Zhou, Z., Qu, X., Zhang, T., Chen, S., & Wang, H. (2025) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2025.123693 · Cited by 12
Volitional Control of Brain Motor Activity and Its Therapeutic Potential
Girges, C., Vijiaratnam, N., Zrinzo, L. U., Ekanayake, J., & Foltynie, T. (2022) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2022.01.007 · Cited by 12
Highly conformable chip-in-foil implants for neural applications
Stieglitz, T., Gueli, C., Martens, J., Floto, N., Eickenscheidt, M., Sporer, M., & Ortmanns, M. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00527-x · Cited by 12
Yeon, P., Rajan, S. K., Falcone, J., Gonzalez, J. L., May, G. S., Bellamkonda, R. V., Brand, O., Bakir, M. S., & Ghovanloo, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3068077 · Cited by 13
A Spatial Transcriptomics Study of the Brain-Electrode Interface in Rat Motor CortexPreprint
Whitsitt, Q. A., Patel, B., Hunt, B., & Purcell, E. K. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.12.03.471147 · Cited by 12
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Druschel, L. N., Kasthuri, N. M., Song, S. S., Wang, J., Hess‐Dunning, A., Chan, E. R., & Capadona, J. R. (2024) · Journal of Materials Chemistry B · doi:10.1039/d4tb01628a · Cited by 12
Eiber, C. D., Delbeke, J., Cardoso, J. R., de Neeling, M. G. J., John, S. E., Lee, C. W., Skefos, J., Sun, A., Prodanov, D., & McKinney, Z. (2021) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2021.3060919 · Cited by 11
Long-term in-vivo recording performance of flexible penetrating microelectrode arrays
Jang, J., Kang, Y. N., Seo, H. W., Kim, B., Choe, H. K., Park, S. H., Lee, M., & Kim, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3656 · Cited by 10
Yamashita, K., Sawahata, H., Yamagiwa, S., Yokoyama, S., Numano, R., Koida, K., & Kawano, T. (2022) · Lab on a Chip · doi:10.1039/d1lc01031j · Cited by 10
Characterization of Active Electrode Yield for Intracortical Arrays: Awake versus Anesthesia
Sturgill, B. S., Radhakrishna, R., Thai, T. T. D., Patnaik, S. S., Capadona, J. R., & Pancrazio, J. J. (2022) · Micromachines · doi:10.3390/mi13030480 · Cited by 11
Masse, N. Y., Jarosiewicz, B., Simeral, J. D., Bacher, D., Stavisky, S. D., Cash, S. S., Oakley, E. M., Berhanu, E., Eskandar, E. N., Friehs, G. M., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.001 · Cited by 11
Self-citationNeural Interfaces Based on Amorphous Silicon Carbide Ultramicroelectrode Arrays
Deku, F., Ghazavi, A., & Cogan, S. F. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2018-0006 · Cited by 11
Capadona, J. R. (2018) · Journal of Immunological Sciences · doi:10.29245/2578-3009/2018/4.1157 · Cited by 11
Ceramic Packages for Acoustically Coupled Neural Implants
Shen, K., & Maharbiz, M. M. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716923 · Cited by 12
Focused Ion Beam Lithography to Etch Nano-architectures into Microelectrodes
Mahajan, S., Sharkins, J. A., Hunter, A. H., Avishai, A., & Ereifej, E. S. (2020) · Journal of Visualized Experiments · doi:10.3791/60004 · Cited by 13
Ultrasound powered piezoelectric neurostimulation devices: a commentary
Sun, T., Wright, J., & Datta-Chaudhuri, T. (2020) · Bioelectronic Medicine · doi:10.1186/s42234-020-00052-6 · Cited by 11
Huang, S.-H., Shmoel, N., Jankowski, M. M., Erez, H., Sharon, A., Abu-Salah, W., Nelken, I., Weiss, A. M., & Spira, M. E. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00926 · Cited by 10
Jung, W., Heo, C., Kim, J. U., Jeong, C., Ryu, H., Park, B., Suh, M., & Kim, T. (2021) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/abdb78 · Cited by 11
Sridharan, A., & Muthuswamy, J. (2021) · Micromachines · doi:10.3390/mi12070761 · Cited by 11
Procházka, A. (2018) · Comprehensive physiology · doi:10.1002/cphy.c180006 · Cited by 15
Lam, D., Javadekar, A., Patil, N. T., Yu, M. H., Li, L., Menendez, D. M., Gupta, A. S., Capadona, J. R., & Shoffstall, A. J. (2022) · SSRN Electronic Journal · doi:10.1016/j.actbio.2023.05.004 · Cited by 12
Xu, Q., Wang, L., Xi, Y., Ruan, T., Cao, J., Xu, M., Zheng, K., Du, Z., Wei, N., Wang, X., et al. (2025) · Small · doi:10.1002/smll.202407950 · Cited by 10
Effect of nanostructures on anchoring stem cell-derived neural tissue to artificial surfaces
Bérces, Z., Pomothy, J. M., Horváth, Á. C., Kőhidi, T., Bényei, E., Fekete, Z., Madarász, E., & Pongracz, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aad972 · Cited by 10
Linking brain activity across scales with simultaneous opto- and electrophysiology
Hoffmann, A., & Helmchen, F. (2023) · Neurophotonics · doi:10.1117/1.nph.11.3.033403 · Cited by 12
Solarana, K., Ye, M., Gao, Y., Rafi, H., & Hammer, D. X. (2020) · Neurophotonics · doi:10.1117/1.nph.7.1.015004 · Cited by 11
Therapeutic hypothermia reduces cortical inflammation associated with utah array implants
Dugan, E. A., Bennett, C., Tamames, I., Dietrich, W. D., King, C., Prasad, A., & Rajguru, S. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab85d2 · Cited by 10
Boergens, K. M., Tadić, A., Hopper, M. S., McNamara, I., Fell, D., Sahasrabuddhe, K., Kong, Y., Straka, M., Sohal, H. S., & Angle, M. R. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0585 · Cited by 9
Distributed Neural Interfaces: Challenges and Trends in Scaling Implantable Technology
Szostak, K. M., Feng, P., Mazza, F., & Constandinou, T. G. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_11-1 · Cited by 10
Silicon Valley new focus on brain computer interface: hype or hope for new applications?
Mitrasinovic, S., Brown, A. P. Y., Schaefer, A. T., Chang, S. D., & Appelboom, G. (2018) · F1000Research · doi:10.12688/f1000research.15726.1 · Cited by 10
Hahn, N. V., Stein, E. A., Donoghue, J. P., Simeral, J. D., Hochberg, L. R., & Willett, F. R. (2025) · medRxiv · doi:10.1101/2025.07.02.25330310 · Cited by 15
Self-citationKing, B. J., Read, G. J. M., & Salmon, P. M. (2024) · Applied Ergonomics · doi:10.1016/j.apergo.2024.104382 · Cited by 9
Minetti, A., Montagni, E., Meneghetti, N., Macchi, F., Coulomb, É., Martello, A., Tiberi, A., Capsoni, S., Mazzoni, A., Mascaro, A. L. A., et al. (2025) · npj Parkinson s Disease · doi:10.1038/s41531-025-01052-6 · Cited by 10
Neural mechanisms underlying intracortical microstimulation for sensory restoration
Hughes, C. L., Chen, X., Grill, W. M., & Kozai, T. D. Y. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01583-6 · Cited by 11
Agency and Accountability: Ethical Considerations for Brain-Computer Interfaces.
Davidoff, E. J. (2020) · PubMed · Cited by 9
Evaluation of Polymer-Coated Carbon Nanotube Flexible Microelectrodes for Biomedical Applications
Ruhunage, C. K., Dhawan, V., Nawarathne, C. P., Hoque, A., Cui, X. T., & Alvarez, N. T. (2023) · Bioengineering · doi:10.3390/bioengineering10060647 · Cited by 9
Chen, K., Padilla, C. G., Kiselyov, K. I., & Kozai, T. D. Y. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122316 · Cited by 9
Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes
Richie, J. M., Letner, J. G., McLane-Svoboda, A. K., Huan, Y., Ghaffari, D. H., della Valle, E., Patel, P. R., Chiel, H. J., Pelled, G., Weiland, J. D., et al. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3360866 · Cited by 9
Conducting polymer nanowires for control of local protein concentration in solution
Morris, J. D., Thourson, S. B., Panta, K. R., Flanders, B. N., & Payne, C. K. (2017) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aa60b0 · Cited by 9
Usoro, J. O., Shih, E., Black, B., Rihani, R. T., Abbott, J., Chakraborty, B., Pancrazio, J. J., & Cogan, S. F. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab4c02 · Cited by 9
Gnatkovsky, V., Cattalini, A., Antonini, A., Spreafico, L., Saini, M., Noè, F. M., Alessi, C., Librizzi, L., Uva, L., Marras, C. E., et al. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s224243 · Cited by 9
The complement cascade at the Utah microelectrode-tissue interface
Bennett, C., Álvarez-Ciara, A., Franklin, M. E., Dietrich, W. D., & Prasad, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120583 · Cited by 9
Evaluation of Amorphous Silicon Carbide on Utah Electrode Arrays by Thermal Accelerated Aging
Nguyen, C. K., Abbott, J. R., Negi, S., & Cogan, S. F. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629701 · Cited by 9
Hybrid decoding of both spikes and low-frequency local field potentials for brain-machine interfaces
Stavisky, S. D., Kao, J. C., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944264 · Cited by 9
Active dissociation of intracortical spiking and high gamma activity
Lei, T., Scheid, M. R., Flint, R. D., Glaser, J. I., & Slutzky, M. W. (2026) · Nature · doi:10.1038/s41586-026-10331-y · Cited by 14
Fluoropolymer-Based Flexible Neural Prosthetic Electrodes for Reliable Neural Interfacing
Kim, Y. H., Park, J., Koo, H., Kim, M. S., & Jung, S.-D. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b12364 · Cited by 8
Capadona, J. R., Shoffstall, A. J., & Pancrazio, J. J. (2019) · Nature Materials · doi:10.1038/s41563-019-0312-9 · Cited by 8
Residual voltage as an ad-hoc indicator of electrode damage in biphasic electrical stimulation
Krishnan, A., Forssell, M., Du, Z. J., Cui, X. T., Fedder, G. K., & Kelly, S. K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac028a · Cited by 8
Atherton, E., Hu, Y., Brown, S., Papiez, E., Ling, V., Colvin, V. L., & Borton, D. A. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6908 · Cited by 8
Ward, S., Riley, C. T., Carey, E. M., Nguyen, J., Esener, S., Nimmerjahn, A., & Sirbuly, D. J. (2022) · Nature Communications · doi:10.1038/s41467-022-30275-x · Cited by 8
Long Term Performance of a Bi-Directional Neural Interface for Deep Brain Stimulation and Recording
Stanslaski, S. R., Case, M., Giftakis, J. E., Raike, R. S., & Stypulkowski, P. H. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.916627 · Cited by 8
Gold microelectrodes array embedded in PDMS for electrical stimulation and signal detection
Cabello, M., Aracil, C., Perdigones, F., Mozo, M., de la Cerda, B., & Quero, J. M. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.026 · Cited by 8
A graphical user interface to assess the neuroinflammatory response to intracortical microelectrodes
Lindner, S. C., Yu, M. H., Capadona, J. R., & Shoffstall, A. J. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.01.003 · Cited by 8
Frederick, R. A., Troyk, P. R., & Cogan, S. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2bb8 · Cited by 7
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7
Advances in Electrode Design and Physiological Considerations for Retinal Implants
Gong, C. A. (2025) · Micromachines · doi:10.3390/mi16050598 · Cited by 9
Druschel, L. N., Song, S. S., Kasthuri, N. M., Wang, J., Conard, J. H., Chan, E. R., Hess‐Dunning, A., & Capadona, J. R. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123477 · Cited by 7
Designing parylene coating for implantable brain–machine interfaces
Ebrahimibasabi, S., Golshahi, M., Shahraki, N., Shabestari, D. T., Sajjadi, M., Hashemi, S., Borchert, A., Baker, I. A., Khalifehzadeh, L., & Arami, H. (2025) · RSC Advances · doi:10.1039/d5ra04683a · Cited by 7
Neuroimplants and the Glial Scar: What Makes the Brain–Computer Link Work?
Paveliev, M., Melnikova, A., Egorchev, A. A., Parpura, V., & Aganov, A. V. (2025) · Journal of Neurochemistry · doi:10.1111/jnc.70203 · Cited by 8
Second harmonic generation for brain imaging: pathology-related studies
Paveliev, M., Melnikova, A., Samigullin, D., Egorchev, A. A., Андреевна, Т. А., Kiyasov, A. P., Popova, I. Y., Parpura, V., & Aganov, A. V. (2025) · Biophysical Reviews · doi:10.1007/s12551-025-01370-2 · Cited by 8
Bjånes, D. A., Bashford, L., Pejsa, K., Lee, B., Liu, C. Y., & Andersen, R. A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae1bd8 · Cited by 7
Kim, Y., Druschel, L. N., Mueller, N. N., Sarno, D., Gisser, K., Hess‐Dunning, A., & Capadona, J. R. (2023) · Frontiers in Biomaterials Science · doi:10.3389/fbiom.2023.1279367 · Cited by 7
Single-Trial Decoding of Motion Direction During Visual Attention From Local Field Potential Signals
Kousarrizi, M. R. N., Nasrabadi, A. M., & Daliri, M. R. (2021) · IEEE Access · doi:10.1109/access.2021.3076865 · Cited by 7
Brain–computer interfaces for human gait restoration
Nenadić, Z. (2021) · Control Theory and Technology · doi:10.1007/s11768-021-00070-y · Cited by 7
Introducing a biomimetic coating for graphene neuroelectronics: toward in-vivo applications
Bourrier, A., Szarpak, A., Veliev, F., Renato, O.-H., Shkorbatova, P. Y., Bonizzato, M., Rey, E., Barraud, Q., Briançon‐Marjollet, A., Auzély‐Velty, R., et al. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab42d6 · Cited by 7
Bamboo-Inspired Materials and Structures
Tan, T., & Soboyejo, W. O. (2020) · Cambridge University Press eBooks · doi:10.1017/9781139058995.005 · Cited by 7
Fabrication and modeling of recessed traces for silicon-based neural microelectrodes
Nolta, N. F., Ghelich, P., Ersöz, A., & Han, M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb9bd · Cited by 7
Artificial sensory feedback for bionic hands
Downey, J. E., Brooks, J., & Bensmaı̈a, S. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814942-3.00008-8 · Cited by 7
Cheng, B. (2020) · Cambridge University Press eBooks · doi:10.1017/9781139058995.012 · Cited by 7
Reclaiming Hand Functions for Chronic Spinal Cord Injury with Epidural Brain-Computer InterfacePreprint
Liu, D., Shan, Y., Chen, L., Li, W., Yao, X., Yao, R., Zheng, J., Liang, F., Zhu, W., Xu, H., et al. (2024) · medRxiv · doi:10.1101/2024.09.05.24313041 · Cited by 10
Walker, R. M., Rieth, L., Iyer, S. S., Bajwa, A. A., Silver, J., Ahmed, T., Tasneem, N., Sharma, M., & Gardner, A. T. (2017) · 2017 IEEE 60th International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8053106 · Cited by 7
Tissue-bioelectronics interfaces
Li, J., Qu, J., & Gao, W. (2026) · Chemical Society Reviews · doi:10.1039/d5cs01422k · Cited by 7
Flexible and Extensible Ribbon-Cable Interconnects for Implantable Electrical Neural Interfaces
Geramifard, N., Khajehzadeh, M., Dousti, B., Abbott, J., Nguyen, C. K., Hernandez-Reynoso, A. G., Joshi‐Imre, A., Varner, V. D., & Cogan, S. F. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c11773 · Cited by 8
Metadata
- Authors
- Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P.
- Affiliations
- Brown University (US)
- Corresponding author
- Barrese, James C
- Rao, Naveen
- Paroo, Kaivon
- Triebwasser, Corey
- Vargas-Irwin, Carlos
- Franquemont, Lachlan
- Donoghue, John P
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-11-12
- Volume
- 10
- Issue
- 6
- Pages
- 066014
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4868924
- OpenAlex
- W1999169980
- Cited by
- 600
- References
- 42
- Citations by year
- 2026: 39 · 2025: 40 · 2024: 43 · 2023: 49 · 2022: 38 · 2021: 63 · 2020: 68 · 2019: 53 · 2018: 67 · 2017: 47 · 2016: 34 · 2015: 28 · 2014: 28 · 2013: 1
- FWCI
- 14.88
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS025074)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical microelectrode arrays, failure mode analysis, brain-computer interface, chronic implantation, non-human primates, rhesus monkeys, silicon microelectrodes, electrode impedance, meningeal reaction, connector failure, neuroprosthetics, chronic neural recording, recording duration
- MeSH terms
- Animals, Cerebral Cortex, Electrodes, Implanted, Female, Macaca mulatta, Male, Microelectrodes, Silicon, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review