The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Open accessAbstract
OBJECTIVE: Brain-computer interfaces (BCIs) using chronically implanted intracortical microelectrode arrays (MEAs) have the potential to restore lost function to people with disabilities if they work reliably for years. Current sensors fail to provide reliably useful signals over extended periods of time for reasons that are not clear. This study reports a comprehensive retrospective analysis from a large set of implants of a single type of intracortical MEA in a single species, with a common set of measures in order to evaluate failure modes. APPROACH: Since 1996, 78 silicon MEAs were implanted in 27 monkeys (Macaca mulatta). We used two approaches to find reasons for sensor failure. First, we classified the time course leading up to complete recording failure as acute (abrupt) or chronic (progressive). Second, we evaluated the quality of electrode recordings over time based on signal features and electrode impedance. Failure modes were divided into four categories: biological, material, mechanical, and unknown. MAIN RESULTS: Recording duration ranged from 0 to 2104 days (5.75 years), with a mean of 387 days and a median of 182 days (n = 78). Sixty-two arrays failed completely with a mean time to failure of 332 days (median = 133 days) while nine array experiments were electively terminated for experimental reasons (mean = 486 days). Seven remained active at the close of this study (mean = 753 days). Most failures (56%) occurred within a year of implantation, with acute mechanical failures the most common class (48%), largely because of connector issues (83%). Among grossly observable biological failures (24%), a progressive meningeal reaction that separated the array from the parenchyma was most prevalent (14.5%). In the absence of acute interruptions, electrode recordings showed a slow progressive decline in spike amplitude, noise amplitude, and number of viable channels that predicts complete signal loss by about eight years. Impedance measurements showed systematic early increases, which did not appear to affect recording quality, followed by a slow decline over years. The combination of slowly falling impedance and signal quality in these arrays indicates that insulating material failure is the most significant factor. SIGNIFICANCE: This is the first long-term failure mode analysis of an emerging BCI technology in a large series of non-human primates. The classification system introduced here may be used to standardize how neuroprosthetic failure modes are evaluated. The results demonstrate the potential for these arrays to record for many years, but achieving reliable sensors will require replacing connectors with implantable wireless systems, controlling the meningeal reaction, and improving insulation materials. These results will focus future research in order to create clinical neuroprosthetic sensors, as well as valuable research tools, that are able to safely provide reliable neural signals for over a decade.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous demonstrations of intracortical insertion of MEAs showed injury and neuronal loss at the implantation location99, as well as signal instabilities contributing to signal loss and performance decline over time100,101.”
From The speech neuroprosthesis (2024) · cites this paper as [100]
In the citing paper
“In spite of the formidable results of using UEA/USEA technologies described above, most penetrating microelectrode arrays currently have maximum in vivo lifetimes of several months or a few years (Suner et al 2005, Prasad et al 2012, Barrese et al 2013).”
From Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies (2016) · cites this paper as Barrese et al 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Single-neuron dynamics in human focal epilepsy
Truccolo, W., Donoghue, J., Hochberg, L. R., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Brown, E. N., Halgren, E., & Cash, S. S. (2011) · Nature Neuroscience · doi:10.1038/nn.2782 · Cited by 528
Self-citationFactors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 481
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Research works printed but not linked: 2
- McConnell G C, 2009, J. Neural Eng., 6
- Prasad A, 2012, J. Neural Eng., 9
Cited by
Sorted by citations
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C., Hwaun, E., Chen, G., Wu, H., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 639
Emerging flexible and wearable physical sensing platforms for healthcare and biomedical applications
Kenry, Yeo, J. C., & Lim, C. T. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.43 · Cited by 550
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Bioinspired neuron-like electronics
Yang, X., Zhou, T., Zwang, T. J., Hong, G., Zhao, Y., Viveros, R. D., Fu, T.-M., Gao, T., & Lieber, C. M. (2019) · Nature Materials · doi:10.1038/s41563-019-0292-9 · Cited by 384
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
Organic electrode coatings for next-generation neural interfaces
Robles, U. A. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 266
Accurate Estimation of Neural Population Dynamics without Spike Sorting
Trautmann, E. M., Stavisky, S. D., Lahiri, S., Ames, K. C., Kaufman, M. T., O’Shea, D. J., Vyas, S., Sun, X., Ryu, S. I., Ganguli, S., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.05.003 · Cited by 255
Jiang, C., Zhang, L., Yang, Q., Huang, S., Shi, H., Long, Q., Qian, B., Liu, Z., Guan, Q., Liu, M., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24680-x · Cited by 232
Kozai, T. D. Y., Catt, K. A., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 214
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 221
Making brain–machine interfaces robust to future neural variability
Sussillo, D., Stavisky, S. D., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2016) · Nature Communications · doi:10.1038/ncomms13749 · Cited by 228
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 214
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 196
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Takmakov, P. A., Ruda, K., Phillips, K. S., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 183
Nolta, N. F., Christensen, M. B., Crane, P. D., Skousen, J. L., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.081 · Cited by 181
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 183
Intracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 165
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Self-citationLuan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Kozai, T. D. Y., & Vazquez, A. L. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00108k · Cited by 154
Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 152
Chronically Implanted Intracranial Electrodes: Tissue Reaction and Electrical Changes
Campbell, A., & Wu, C. (2018) · Micromachines · doi:10.3390/mi9090430 · Cited by 149
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects
Fernández, E., Greger, B. E., House, P. A., Aranda, I., Botella, C., Albísua, J., Soto‐Sánchez, C., Alfaro, A., & Normann, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00024 · Cited by 153
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Wearable and Implantable Electroceuticals for Therapeutic Electrostimulations
Long, Y., Li, J., Yang, F., Wang, J., & Wang, X. (2021) · Advanced Science · doi:10.1002/advs.202004023 · Cited by 141
Kozai, T. D. Y., Du, Z. J., Gugel, Z. V., Smith, M. A., Chase, S. M., Bodily, L., Caparosa, E. M., Friedlander, R. M., & Cui, X. T. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.12.010 · Cited by 137
Stavisky, S. D., Kao, J. C., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036009 · Cited by 139
Stable long-term BCI-enabled communication in ALS and locked-in syndrome using LFP signals
Milekovic, T., Sarma, A. A., Bacher, D., Simeral, J. D., Saab, J., Pandarinath, C., Sorice, B. L., Blabe, C. H., Oakley, E. M., Tringale, K. R., et al. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00493.2017 · Cited by 148
Self-citation3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
Piret, G., Hébert, C., Mazellier, J.-P., Rousseau, L., Scorsone, E., Cottance, M., Lissorgues, G., Heuschkel, M. O., Picaud, S. A., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.021 · Cited by 142
Michelson, N. J., Vazquez, A. L., Eles, J. R., Salatino, J. W., Purcell, E. K., Williams, J. J., Cui, X. T., & Kozai, T. D. Y. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9dae · Cited by 126
Stability of PEDOT:PSS‐Coated Gold Electrodes in Cell Culture Conditions
Dijk, G., Rutz, A. L., & Malliaras, G. G. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900662 · Cited by 132
Tracking neural activity from the same cells during the entire adult life of mice
Zhao, S., Tang, X., Tian, W., Partarrieu, S., Liu, R., Shen, H., Lee, J. Y., Guo, S., Lin, Z., & Jia Liu, B. (2023) · Nature Neuroscience · doi:10.1038/s41593-023-01267-x · Cited by 134
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Potter, K. A., Jorfi, M., Householder, K. T., Foster, E. J., Weder, C., & Capadona, J. R. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.01.018 · Cited by 127
Configuration of electrical spinal cord stimulation through real-time processing of gait kinematics
Capogrosso, M., Wagner, F. B., Gandar, J., Moraud, E. M., Wenger, N., Milekovic, T., Shkorbatova, P. Y., Pavlova, N., Евгеньевич, М. П., Bézard, E., et al. (2018) · Nature Protocols · doi:10.1038/s41596-018-0030-9 · Cited by 125
A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces
Ferguson, M., Sharma, D., Ross, D., & Zhao, F. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900558 · Cited by 128
Latent Factors and Dynamics in Motor Cortex and Their Application to Brain–Machine Interfaces
Pandarinath, C., Ames, K. C., Russo, A. A., Farshchian, A., Miller, L. E., Dyer, E. L., & Kao, J. C. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1669-18.2018 · Cited by 103
Eles, J. R., Vazquez, A. L., Snyder, N. R., Lagenaur, C. F., Murphy, M. C., Kozai, T. D. Y., & Cui, X. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.054 · Cited by 117
Implantable, wireless device platforms for neuroscience research
Gutruf, P., & Rogers, J. A. (2017) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.12.007 · Cited by 122
Sensor Modalities for Brain-Computer Interface Technology: A Comprehensive Literature Review
Martini, M. L., Oermann, E. K., Opie, N. L., Panov, F. E., Oxley, T. J., & Yaeger, K. (2019) · Neurosurgery · doi:10.1093/neuros/nyz286 · Cited by 120
Single-trial decoding of movement intentions using functional ultrasound neuroimaging
Norman, S. L., Maresca, D., Christopoulos, V. N., Griggs, W. S., Demené, C., Tanter, M., Shapiro, M. G., & Andersen, R. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.03.003 · Cited by 121
Compliant intracortical implants reduce strains and strain rates in brain tissuein vivo
Sridharan, A., Nguyen, J. K., Capadona, J. R., & Muthuswamy, J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036002 · Cited by 112
A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants
Yang, W., Gong, Y. P., & Li, W. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.622923 · Cited by 109
Silva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
“Previous demonstrations of intracortical insertion of MEAs showed injury and neuronal loss at the implantation location 99 , as well as signal instabilities contributing to signal loss and performance decline over time 100,101 .”
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 104
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Multifunctional Fibers as Tools for Neuroscience and Neuroengineering
Canales, A., Park, S., Kilias, A., & Anikeeva, P. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00558 · Cited by 103
Caldwell, R., Street, M. G., Sharma, R., Takmakov, P. A., Baker, B., & Rieth, L. W. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119731 · Cited by 103
Recent advances in silicon-based neural microelectrodes and microsystems: a review
Fekete, Z. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.055 · Cited by 99
Applications of brain-computer interfaces to the control of robotic and prosthetic arms
Vilela, M., & Hochberg, L. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00008-1 · Cited by 103
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Ravikumar, M., Sunil, S., Black, J., Barkauskas, D. S., Haung, A. Y., Miller, R. H., Selkirk, S. M., & Capadona, J. R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.05.084 · Cited by 97
Neural stimulation and recording performance in human sensorimotor cortex over 1500 days
Hughes, C. L., Flesher, S. N., Weiss, J. M., Downey, J. E., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac18ad · Cited by 99
Flint, R. D., Scheid, M. R., Wright, Z. A., Solla, S. A., & Slutzky, M. W. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.2339-15.2016 · Cited by 93
Single unit action potentials in humans and the effect of seizure activity
Merricks, E. M., Smith, E. H., McKhann, G. M., Goodman, R. R., Bateman, L. M., Emerson, R. G., Schevon, C. A., & Trevelyan, A. J. (2015) · Brain · doi:10.1093/brain/awv208 · Cited by 94
Degenhart, A. D., Eles, J. R., Dum, R. P., Mischel, J., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler‐Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 96
Two-photon imaging of chronically implanted neural electrodes: Sealing methods and new insights
Kozai, T. D. Y., Eles, J. R., Vazquez, A. L., & Cui, X. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.10.007 · Cited by 88
Explant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90
Eles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.043 · Cited by 86
Hydrogels for next generation neural interfaces
Cheng, S., Zhu, R., & Xu, X. (2024) · Communications Materials · doi:10.1038/s43246-024-00541-0 · Cited by 96
Guo, R., & Liu, J. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa891c · Cited by 87
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Cody, P. A., Eles, J. R., Lagenaur, C. F., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.025 · Cited by 87
Information Systems Opportunities in Brain–Machine Interface Decoders
Kao, J. C., Stavisky, S. D., Sussillo, D., Nuyujukian, P., & Shenoy, K. V. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2307357 · Cited by 85
Achieving long-term stability of thin-film electrodes for neurostimulation
Oldroyd, P., & Malliaras, G. G. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.05.004 · Cited by 91
Sung, C., Jeon, W., Nam, K. S., Kim, Y., Butt, H., & Park, S. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb00872a · Cited by 87
Restoring tactile and proprioceptive sensation through a brain interface
Tabot, G. A., Kim, S. S., Winberry, J. E., & Bensmaia, S. J. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.08.029 · Cited by 83
Interim Safety Profile From the Feasibility Study of the BrainGate Neural Interface System
Rubin, D. B., Ajiboye, A. B., Barefoot, L., Bowker, M., Cash, S. S., Chen, D., Donoghue, J. P., Eskandar, E. N., Friehs, G., Grant, C., et al. (2023) · Neurology · doi:10.1212/wnl.0000000000201707 · Cited by 81
Self-citationBrain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Slutzky, M. W. (2018) · The Neuroscientist · doi:10.1177/1073858418775355 · Cited by 86
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 86
The science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaïa, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 79
Blood brain barrier (BBB)-disruption in intracortical silicon microelectrode implants
Bennett, C., Samikkannu, M., Mohammed, F. S., Dietrich, W. D., Rajguru, S. M., & Prasad, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.036 · Cited by 81
Decoding Local Field Potentials for Neural Interfaces
Andrew, J. O., & Hall, T. M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2612001 · Cited by 78
Lycke, R., Kim, R., Zolotavin, P., Montes, J., Sun, Y., Kőszeghy, Á., Altun, E., Noble, B., Yin, R., He, F., et al. (2023) · Cell Reports · doi:10.1016/j.celrep.2023.112554 · Cited by 79
Melatonin improves quality and longevity of chronic neural recording
Golabchi, A., Wu, B., Li, X., Carlisle, D. L., Kozai, T. D. Y., Friedlander, R. M., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.026 · Cited by 74
Schwerdt, H. N., Zhang, E., Kim, M. J., Yoshida, T., Stanwicks, L. L., Amemori, S., Dağdeviren, H. E., Langer, R., Cima, M. J., & Graybiel, A. M. (2018) · Communications Biology · doi:10.1038/s42003-018-0147-y · Cited by 77
Visual Guidance in Control of Grasping
Janssen, P., & Scherberger, H. (2015) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-071714-034028 · Cited by 86
Soft Electronics Based on Stretchable and Conductive Nanocomposites for Biomedical Applications
Zambrano, B. L., Renz, A. F., Ruff, T., Lienemann, S., Tybrandt, K., Vörös, J., & Lee, J. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202001397 · Cited by 74
Robust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
Michelson, N. J., & Kozai, T. D. Y. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00299.2018 · Cited by 71
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
A Dual-Band Wireless Power Transmission System for Evaluating mm-Sized Implants
Jia, Y., Mirbozorgi, S. A., Zhang, P., Inan, O. T., Li, W., & Ghovanloo, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2915649 · Cited by 69
Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain
Golabchi, A., Woeppel, K. M., Li, X., Lagenaur, C. F., & Cui, X. T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112096 · Cited by 73
A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes
Pas, J., Rutz, A. L., Quilichini, P., Slézia, A., Ghestem, A., Kaszás, A., Donahue, M. J., Curto, V. F., O'Connor, R. P., Bernard, C., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aadc1d · Cited by 69
Peripheral nerve bionic interface: a review of electrodes
Russell, C., Roche, A. D., & Chakrabarty, S. (2019) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-019-00086-3 · Cited by 67
Metadata
- Authors
- Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P.
- Affiliations
- Brown University (US)
- Corresponding author
- Barrese, James C
- Rao, Naveen
- Paroo, Kaivon
- Triebwasser, Corey
- Vargas-Irwin, Carlos
- Franquemont, Lachlan
- Donoghue, John P
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-11-12
- Volume
- 10
- Issue
- 6
- Pages
- 066014
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4868924
- OpenAlex
- W1999169980
- Cited by
- 600
- References
- 42
- Citations by year
- 2026: 39 · 2025: 40 · 2024: 43 · 2023: 49 · 2022: 38 · 2021: 63 · 2020: 68 · 2019: 53 · 2018: 67 · 2017: 47 · 2016: 34 · 2015: 28 · 2014: 28 · 2013: 1
- FWCI
- 14.88
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS025074)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical microelectrode arrays, failure mode analysis, brain-computer interface, chronic implantation, non-human primates, rhesus monkeys, silicon microelectrodes, electrode impedance, meningeal reaction, connector failure, neuroprosthetics, chronic neural recording, recording duration
- MeSH terms
- Animals, Cerebral Cortex, Electrodes, Implanted, Female, Macaca mulatta, Male, Microelectrodes, Silicon, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review