Temporal properties of network-mediated responses to repetitive stimuli are dependent upon retinal ganglion cell type
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To provide artificially-elicited vision that is temporally dynamic, retinal prosthetic devices will need to repeatedly stimulate retinal neurons. However, given the diversity of physiological types of retinal ganglion cells (RGCs) as well as the heterogeneity of their responses to electric stimulation, temporal properties of RGC responses have not been adequately investigated. Here, we explored the cell type dependence of network-mediated RGC responses to repetitive electric stimulation at various stimulation rates. APPROACH: We examined responses of ON and OFF types of RGCs in the rabbit retinal explant to five consecutive stimuli with varying inter-stimulus intervals (10-1000 ms). Each stimulus was a 4 ms long monophasic sinusoidal cathodal current, which was applied epiretinally via a conical electrode. Spiking activity of targeted RGCs was recorded using a cell-attached patch electrode. MAIN RESULTS: ON and OFF cells had distinct responses to repetitive stimuli. Consistent with earlier studies, OFF cells always generated reduced responses to subsequent stimuli compared to responses to the first stimulus. In contrast, a new stimulus to ON cells suppressed all pending/ongoing responses from previous stimuli and initiated its own response that was remarkably similar to the response from a single stimulus in isolation. This previously unreported 'reset' behavior was observed exclusively and consistently in ON cells. These contrasts between ON and OFF cells created a range of stimulation rates (4-7 Hz) that maximized the ratio of the responses arising in ON versus OFF cells. SIGNIFICANCE: Previous clinical testing reported that subjects perceive bright phosphenes (ON responses) and also prefer stimulation rates of 5-7 Hz. Our results suggest that responses of ON cells are weak at high rates of stimulation (> ∼7 Hz) due to the reset while responses of OFF cells are strong at low rates (< ∼4 Hz) due to reduced desensitization, both reducing the ratio of ON to OFF responses. In combination with previous results indicating that responses in ON cells more closely match physiological patterns (Im and Fried 2015 J. Physiol. 593 3577-96), our results offer a potential reason for the user preference of intermediate rates (5-7 Hz).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 3×
“This is consistent with preferential reporting of ON responses in human trials (Humayun et al 1996, 2003, Fujikado et al 2007, Naycheva et al 2012).”
BackgroundResultSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
The Types of Retinal Ganglion Cells: Current Status and Implications for Neuronal Classification
Sanes, J. R., & Masland, R. H. (2015) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-071714-034120 · Cited by 789
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 1×
“…also have demonstrated that electrically-elicited vision can be somewhat useful for performing tasks of daily living in those blinded by outer retinal degeneration (Ahuja et al 2011, Zrenner et al 2011, Humayun et al 2012, da Cruz et al 2013, Kotecha et al 2014, Ho et al 2015, Stingl et al 2015).”
BackgroundRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“For the past decade, several different groups have reported promising clinical outcomes (Humayun et al 2003, Rizzo et al 2003, Zrenner et al 2011, Stingl et al 2013, Shivdasani et al 2014, Ho et al 2015) such as localization/recognition of high contrast objects and reading simple words comprised of…”
BackgroundArtificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387 · cited 3×
“This is somewhat in contrast to the range of 5–7 Hz preferred by users of retinal prosthetics (Zrenner et al 2011, Stingl et al 2013, Chuang et al 2014, Stingl et al 2015).”
BackgroundResultda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 1×
“…also have demonstrated that electrically-elicited vision can be somewhat useful for performing tasks of daily living in those blinded by outer retinal degeneration (Ahuja et al 2011, Zrenner et al 2011, Humayun et al 2012, da Cruz et al 2013, Kotecha et al 2014, Ho et al 2015, Stingl et al 2015).”
BackgroundAhuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146 · cited 1×
“In order to capture responses with long latencies (Freeman and Fried 2011, Lee et al 2013, Boinagrov et al 2014, Im and Fried 2015), responses were recorded for 1 s following stimulus onset.”
BackgroundTemporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Naycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55
The response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38 · cited 1×
“…Sanes and Masland 2015) and the heterogeneity in their response to electric stimulation (Jensen and Rizzo III 2008, Tsai et al 2009, Cai et al 2011, Cai et al 2013, Lee et al 2013, Twyford et al 2014, Im and Fried 2015, Twyford and Fried 2015), temporal properties of retinal responses are likely…”
BackgroundSelf-citation
Cited by
Parallel and distributed encoding of speech across human auditory cortex
Hamilton, L. S., Oganian, Y., Hall, J., & Chang, E. F. (2021) · Cell · doi:10.1016/j.cell.2021.07.019 · Cited by 230
A Spatial Map of Onset and Sustained Responses to Speech in the Human Superior Temporal Gyrus
Hamilton, L. S., Edwards, E., & Chang, E. F. (2018) · Current Biology · doi:10.1016/j.cub.2018.04.033 · Cited by 180
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
“In a following study (Im and Fried, 2016), they examined the network-mediated responses to repetitive stimulation and also found differences between ON and OFF cells.”
BackgroundCorna, A., Ramesh, P., Jetter, F., Lee, M.-J., Macke, J. H., & Zeck, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0679 · Cited by 18
“Preferred activation of different RGC cell types in epiretinal configuration has been reported to various degrees using low frequency [75] and high-frequency pulses [76–78].”
BackgroundHuman-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Metadata
- Authors
- Im, M., & Fried, S. I.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-02-23
- Volume
- 13
- Issue
- 2
- Pages
- 025002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2469493536
- Cited by
- 65
- References
- 15
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.