Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses
The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
An estimated 25 million people in the US alone rely on implanted medical devices, ∼2.5 million implanted within the nervous system. Even though many devices perform adequately for years, the host response to medical devices often severely limits tissue integration and long-term performance. This host response is believed to be particularly limiting in the case of intracortical microelectrodes, where it has been shown that glial cell encapsulation and localized neuronal cell loss accompany intracortical microelectrode implantation. Since neuronal ensembles must be within ∼50 µm of the electrode to obtain neuronal spikes and local field potentials, developing a better understanding of the molecular and cellular environment at the device-tissue interface has been the subject of significant research. Unfortunately, immunohistochemical studies of scar maturation in correlation to device function have been inconclusive. Therefore, here we present a detailed quantitative study of the cellular events and the stability of the blood-brain barrier (BBB) following intracortical microelectrode implantation and cortical stab injury in a chronic survival model. We found two distinctly inverse multiphasic profiles for neuronal survival in device-implanted tissue compared to stab-injured animals. For chronically implanted animals, we observed a biphasic paradigm between blood-derived/trauma-induced and CNS-derived inflammatory markers driving neurodegeneration at the interface. In contrast, stab injured animals demonstrated a CNS-mediated neurodegenerative environment. Collectively these data provide valuable insight to the possibility of multiple roles of chronic neuroinflammatory events on BBB disruption and localized neurodegeneration, while also suggesting the importance to consider multiphasic neuroinflammatory kinetics in the design of therapeutic strategies for stabilizing neural interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595 · cited 1×
“Astrocytes play a critical role in BBB preservation and function [2].”
BackgroundMicroglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110 · cited 1×
“It is understood that upon activation, microglia cells release pro-inflammatory cytokines, nitric oxide and reactive oxygen species; all of which highly impact the permeability of the localized vasculature and neuronal survival [11, 24, 25, 59, 65].”
BackgroundRegeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078 · cited 2×
“Perturbation of neuronal tissue results in astrocyte activation and glial scar formation [54, 5, 19, 49, 45, 31].”
BackgroundResultResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“In fact, several groups have proposed the role of pro-inflammatory cytokines in neuroinflammation at the microelectrode–tissue interface [28, 44].”
BackgroundLarge-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
The glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,803 · cited 2×
“Perturbation of neuronal tissue results in astrocyte activation and glial scar formation [54, 5, 19, 49, 45, 31].”
BackgroundResultMicroglia as a source and target of cytokines
Hanisch, U. (2002) · Glia · doi:10.1002/glia.10161 · Cited by 1,645 · cited 1×
“It is understood that upon activation, microglia cells release pro-inflammatory cytokines, nitric oxide and reactive oxygen species; all of which highly impact the permeability of the localized vasculature and neuronal survival [11, 24, 25, 59, 65].”
BackgroundReactive Astrocytes Protect Tissue and Preserve Function after Spinal Cord Injury
Faulkner, J. R., Herrmann, J. E., Woo, M. J., Tansey, K. E., Doan, N. B., & Sofroniew, M. V. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3547-03.2004 · Cited by 1,598 · cited 10×
“Chronically implanted animals demonstrated both BBB-associated and CNSderived neurodegeneration.”
BackgroundInfluentialDijkstra, C. D., Döpp, E. A., Joling, P., & Kraal, G. (1985) · Microenvironments in the Lymphoid System · doi:10.1007/978-1-4613-2463-8_50 · Cited by 1,598
Microglia-specific localisation of a novel calcium binding protein, Iba1
Ito, D., Imai, Y., Ohsawa, K., Nakajima, K., Fukuuchi, Y., & Kohsaka, S. (1998) · Molecular Brain Research · doi:10.1016/s0169-328x(98)00040-0 · Cited by 1,476
Cited by
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(78, 87, 109, 161, 162) Furthermore, several studies have failed to establish a direct correlation between neuro-inflammation and recording quality.”
BackgroundSelf-citationImplantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“of the former to detect a signal, since to adequately sense the neuronal spikes and local field potentials, the distance between the neuronal ensembles and the target neurons should be within ~50 μm [77].”
Neural Stimulation and Recording with Bidirectional, Soft Carbon Nanotube Fiber Microelectrodes
Vitale, F., Summerson, S. R., Aazhang, B., Kemere, C., & Pasquali, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b01060 · Cited by 311
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
“Surgical procedures for device implantation closely followed an established protocol, with only minor changes [8, 20, 21].”
BackgroundSelf-citationThe impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
“If the electrode is removed soon after insertion, the local area will heal [19, 20].”
BackgroundHigh‐Performance Graphene‐Fiber‐Based Neural Recording Microelectrodes
Wang, K., Frewin, C. L., Esrafilzadeh, D., Yu, C., Wang, C., Pancrazio, J. J., Romero‐Ortega, M., Jalili, R., & Wallace, G. (2019) · Advanced Materials · doi:10.1002/adma.201805867 · Cited by 191
Spencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-02107-2 · Cited by 181
Nolta, N. F., Christensen, M. B., Crane, P. D., Skousen, J. L., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.081 · Cited by 175
“For single-shank planar silicon devices [22, 28], four-shank planar silicon devices [24], and single microwires [16], the injury of device insertion alone is not sufficient to cause significant brain tissue loss or persistent inflammation in brain tissue beyond a few weeks.”
BackgroundSlow insertion of silicon probes improves the quality of acute neuronal recordings
Fiáth, R., Márton, A. L., Mátyás, F., Pinke, D., Márton, G., Tóth, K., & Ulbert, I. (2019) · Scientific Reports · doi:10.1038/s41598-018-36816-z · Cited by 167
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 162
Kozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Potter, K. A., Buck, A. C., Self, W. K., Callanan, M. E., Sunil, S., & Capadona, J. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.035 · Cited by 129
Silk-Backed Structural Optimization of High-Density Flexible Intracortical Neural Probes
Wu, F., Tien, L. W., Chen, F., Berke, J. D., Kaplan, D. L., & Yoon, E. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2375326 · Cited by 80
Chronic intracortical neural recordings using microelectrode arrays coated with PEDOT–TFB
Charkhkar, H., Knaack, G. L., McHail, D. G., Mandal, H. S., Peixoto, N., Rubinson, J. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.022 · Cited by 68
Skousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
Sharma, G., Annetta, N., Friedenberg, D., Blanco, T., Vasconcelos, D., Shaikhouni, A., Rezai, A. R., & Bouton, C. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00010 · Cited by 41
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35
The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
“…to neural implants are being unveiled (Biran et al., 2005; Polikov et al., 2005; Grill et al., 2009; Kotov et al., 2009; Marin and Fernandez, 2010; Potter et al., 2012; Kozai et al., 2012a, 2014, 2015a,b; Jorfi et al., 2015)materials science and tissue engineering have shown increasing importance…”
BackgroundBiotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Metadata
- Authors
- Potter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-07-25
- Volume
- 9
- Issue
- 4
- Pages
- 046020
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1969870305
- Cited by
- 239
- References
- 66
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.