The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Abstract
BACKGROUND: Compliance with glucose monitoring by patients with diabetes is poor because of the pain and inconvenience of conventional blood collection using lancets. To improve compliance, and thereby reduce morbidity and mortality associated with poor glucose control, this study sought to develop and test minimally invasive microneedles to extract dermal interstitial fluid (ISF) for glucose monitoring. METHODS: We used a thermal puller to fabricate individual or multi-needle arrays of glass microneedles with tip radii of 15-40 microm to penetrate 700-1,500 microm deep into the skin of anesthetized hairless rats or conscious, normal, adult, human subjects. After applying a vacuum of 200-500 mm Hg for 2-10 min, we extracted ISF and measured glucose concentration. These measurements were compared with glucose levels in blood collected from the tail vein of rats or finger stick on humans. RESULTS: Using this procedure, 1-10 microL of ISF was extracted out of holes punctured in the skin using microneedles. Human subjects generally reported the procedure as painless. ISF glucose concentration correlated well with blood levels based on 140 measurements on 15 rats and six measurements on six human subjects, where 95% of rat data and 100% of human data fell within the clinically acceptable A + B region in Clarke Error Grid analysis. A linear calibration factor was needed to correlate ISF and blood glucose concentrations using our standard procedure. Modifying the procedure to prevent ISF evaporation during extraction provided a one-to-one correlation that eliminated the need for calibration. ISF glucose measurements tracked rapidly changing blood glucose levels following insulin injection with a time lag of less than 20 min. CONCLUSIONS: These results suggest that microneedle devices can be used to extract ISF for painless glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Self-citationEvaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Self-citationMcAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationLack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00041 · Cited by 576
Self-citationTransdermal Delivery of Insulin Using Microneedles in Vivo
Martanto, W., Davis, S. P., Holiday, N. R., Wang, J., Gill, H. S., & Prausnitz, M. R. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000029282.44140.2e · Cited by 521
Self-citationMethods for in vitro percutaneous absorption studies II. Animal models for human skin
Bronaugh, R. L., Stewart, R. F., & Congdon, E. R. (1982) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(82)90149-1 · Cited by 459
Mikszta, J. A., Alarcon, J. B., Brittingham, J. M., Sutter, D. E., Pettis, R. J., & Harvey, N. G. (2002) · Nature Medicine · doi:10.1038/nm0402-415 · Cited by 398
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationLarrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 526
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Microneedles for intradermal and transdermal drug delivery
Tuan-Mahmood, T.-M., McCrudden, M. T. C., Torrisi, B. M., McAlister, E., Garland, M. J., Singh, T. R. R., & Donnelly, R. F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.05.005 · Cited by 468
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Microneedles: an emerging transdermal drug delivery system
Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P. (2012) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.2011.01369.x · Cited by 455
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Self-citationRecent advances of microneedles for biomedical applications: drug delivery and beyond
Yang, J., Liu, X., Fu, Y., & Song, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.03.007 · Cited by 378
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
Self-citationLipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Clinical administration of microneedles: skin puncture, pain and sensation
Haq, M. I., Smith, E., John, D. N., Kalavala, M., Edwards, C., Anstey, A., Morrissey, A., & Birchall, J. C. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9208-1 · Cited by 329
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Prausnitz, M. R., Mikszta, J. A., Cormier, M., & Andrianov, A. K. (2009) · Current Topics in Microbiology and Immunology · doi:10.1007/978-3-540-92165-3_18 · Cited by 314
Self-citationLab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Bhatnagar, S., Dave, K., & Venuganti, V. V. K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.029 · Cited by 297
Microinfusion Using Hollow Microneedles
Martanto, W., Moore, J. S., Kashlan, O., Kamath, R., Wang, P. M., O'Neal, J. M., & Prausnitz, M. R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-8498-8 · Cited by 262
Self-citationTransdermal electroosmotic flow generated by a porous microneedle array patch
Kusama, S., Sato, K., Matsui, Y., Kimura, N., Abe, H., Yoshida, S., & Nishizawa, M. (2021) · Nature Communications · doi:10.1038/s41467-021-20948-4 · Cited by 260
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901201 · Cited by 257
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
“Wang et al. analyzed this lag time and developed correlations between the interstitial glucose level and blood glucose level [88].”
BackgroundVenugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912544 · Cited by 76
A microneedle device for rapid dermal interstitial fluid sampling
Hung, A. H., Kamat, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx5492 · Cited by 22
Comprehensive Nanorobotic Control of Human Morbidity and Aging
Freitas, R. A. (2010) · The Future of Aging · doi:10.1007/978-90-481-3999-6_23 · Cited by 16
Metadata
- Authors
- Wang, P. M., Cornwell, M., & Prausnitz, M. R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-02
- Volume
- 7
- Issue
- 1
- Pages
- 131-141
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2006086487
- Cited by
- 267
- References
- 26
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.