Self-Monitoring of Blood Glucose in Diabetes: From Evidence to Clinical Reality in Central and Eastern Europe—Recommendations from the International Central-Eastern European Expert Group
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Self-monitoring of blood glucose (SMBG) is universally considered to be an integral part of type 1 diabetes management and crucial for optimizing the safety and efficacy of complex insulin regimens. This extends to type 2 diabetes patients on intensive insulin therapy, and there is also a growing body of evidence suggesting that structured SMBG is beneficial for all type 2 diabetes patients, regardless of therapy. However, access to SMBG can be limited in many countries in Central and Eastern Europe. A consensus group of diabetes experts from 10 countries in this region (with overlapping historical, political, and social environments)--Bulgaria, Croatia, Czech Republic, Hungary, Poland, Romania, Serbia, Slovakia, Slovenia, and Ukraine--was formed to discuss the role of SMBG across the spectrum of patients with diabetes. The group considered SMBG to be an essential tool that should be accessible to all patients with diabetes, including those with non-insulin-treated type 2 diabetes. The current article summarizes the evidence put forward by the consensus group and provides their recommendations for the appropriate use of SMBG as part of individualized patient management. The ultimate goal of these evidence-based recommendations is to help patients and providers in Central and Eastern Europe to make optimal use of SMBG in order to maximize the efficacy and safety of glucose-lowering therapies, to prevent complications, and to empower the patient to play a more active role in the management of their diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Inzucchi, S. E., Bergenstal, R. M., Buse, J. B., Diamant, M., Ferrannini, E., Nauck, M., Peters, A. L., Tsapas, A., Wender, R., & Matthews, D. R. (2012) · Diabetologia · doi:10.1007/s00125-012-2534-0 · Cited by 3,919
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389
Handelsman, Y., Mechanick, J. I., Blonde, L., Grunberger, G., Bloomgarden, Z. T., Bray, G. A., Dagogo-Jack, S., Davidson, J. A., Einhorn, D., Ganda, O., et al. (2011) · Endocrine Practice · doi:10.4158/ep.17.s2.1 · Cited by 513
Miller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network (2013) · Diabetes Care · doi:10.2337/dc12-1770 · Cited by 505
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Clarke, S. F., & Foster, J. R. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12002443 · Cited by 456
Farmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
Hypoglycemia and cardiovascular risks
Frier, B. M., Schernthaner, G., & Heller, S. R. (2011) · Diabetes Care · doi:10.2337/dc11-s220 · Cited by 381 · cited 1×
“The importance of hypoglycemia avoidance is exemplified by growing evidence for an association between a history of severe hypoglycemic episodes and serious adverse outcomes over the long term, including death, major vascular events, and dementia.(82,82) It has been suggested that the utility of SMBG can be improved t…”
Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes Who Are Not Using Insulin
Welschen, L. M. C., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A. B., & Bouter, L. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1510 · Cited by 374
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
O’Kane, M. J., Bunting, B., Copeland, M., & Coates, V. E. (2008) · BMJ · doi:10.1136/bmj.39534.571644.be · Cited by 326
Meal-Related Structured Self-Monitoring of Blood Glucose
Schwedes, U., Siebolds, M., Mertes, G., & For the SMBG Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.1928 · Cited by 300
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Self-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
Drury, P. L., Ting, R., Zannino, D., Ehnholm, C., Flack, J., Whiting, M., Fassett, R., Ansquer, J.-C., Dixon, P., Davis, T. M. E., et al. (2011) · Diabetologia · doi:10.1007/s00125-010-1854-1 · Cited by 195
Farmer, A. J., Perera, R., Ward, A., Heneghan, C., Oke, J., Barnett, A. H., Davidson, M. B., Guerci, B., Coates, V., Schwedes, U., et al. (2012) · BMJ · doi:10.1136/bmj.e486 · Cited by 156
Franciosi, M., Lucisano, G., Pellegrini, F., Cantarello, A., Consoli, A., Cucco, L., Ghidelli, R., Sartore, G., Sciangula, L., Nicolucci, A., et al. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03268.x · Cited by 137
Prediction of Severe Hypoglycemia
Cox, D. J., Gonder-Frederick, L., Ritterband, L., Clarke, W., & Kovatchev, B. P. (2007) · Diabetes Care · doi:10.2337/dc06-1386 · Cited by 129
Poolsup, N., Suksomboon, N., & Rattanasookchit, S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0091 · Cited by 127
Barnett, A. H., Krentz, A. J., Strojek, K., Sieradzki, J., Azizi, F., Embong, M., Imamoglu, S., Perušičová, J., Uličiansky, V., & Winkler, G. (2008) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2008.00894.x · Cited by 106
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Axel-Schweitzer, M., Petersen, B., & Wagner, R. S. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0073 · Cited by 85
Bonomo, K., De Salve, A., Fiora, E., Mularoni, E., Massucco, P., Poy, P., Pomero, A., Cavalot, F., Anfossi, G., & Trovati, M. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.021 · Cited by 53 · cited 1×
“one profile every month with fasting and postprandial values) can provide HbA1c improvements, as long as compliance is sufficient.(59) SMBG and hypoglycemia.”
French, D. P., Wade, A. N., Yudkin, P., Neil, H. A. W., Kinmonth, A. L., & Farmer, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02569.x · Cited by 49
Kempf, K., Kruse, J., & Martin, S. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0116 · Cited by 48
Schnell, O., Alawi, H., Battelino, T., Ceriello, A., Diem, P., Felton, A., Grzeszczak, W., Harno, K., Kempler, P., Satman, I., et al. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0028 · Cited by 47
Fisher, L., Polonsky, W. H., Parkin, C. G., Jelsovsky, Z., Petersen, B., & Wagner, R. S. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.016 · Cited by 44 · cited 1×
“Further analyses from this study found that structured SMBG led to significant increases in self-confidence and autonomous motivation associated with diabetes self-management.(69) The ROSSO-in-praxi study was an uncontrolled trial that evaluated the impact of a relatively inexpensive 12-week structured SMBG-based life…”
Kempf, K., Tankova, T., & Martin, S. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0213 · Cited by 40
Self-citationKhamseh, M. E., Ansari, M., Malek, M., Shafiee, G., & Baradaran, H. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500228 · Cited by 20
B. Davidson, M. (2010) · Reviews on Recent Clinical Trials · doi:10.2174/157488710792007248 · Cited by 15 · cited 1×
“35,36 However, until recently, the majority of randomized controlled trials (nine out of 14 performed up to the year 2010) failed to show any significant benefit on metabolic control 37–39 (for reviews, see Davidson 11 and Kolb et al. 12 ).”
Cited by
Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
Jancev, M., Vissers, T. A. C. M., Visseren, F. L. J., van Bon, A. C., Serné, E. H., DeVries, J. H., de Valk, H. W., & van Sloten, T. T. (2024) · Diabetologia · doi:10.1007/s00125-024-06107-6 · Cited by 191
“Fingerstick-based self-monitoring of blood glucose (SMBG) has been the most used method for measuring daily glucose levels [2].”
MethodTeo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186
Young, L. A., Buse, J. B., Weaver, M. A., Vu, M. B., Mitchell, C. M., Blakeney, T., Grimm, K., Rees, J., Niblock, F., Donahue, K. E., et al. (2017) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.1233 · Cited by 148
“BMI, median (range) 33 (22-58) 33 (21-62) 34 (21-75) 33 (21-75)”
Metadata
- Authors
- Czupryniak, L., Barkai, L., Bolgarska, S., Bronisz, A., Broz, J., Cypryk, K., Honka, M., Janez, A., Krnic, M., Lalic, N., Martinka, E., Rahelic, D., Roman, G., Tankova, T., Várkonyi, T., Wolnik, B., & Zherdova, N.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2014-07
- Volume
- 16
- Issue
- 7
- Pages
- 460-475
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2053834796
- Cited by
- 93
- References
- 31
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.