The Relationship Between Stress Shielding and Bone Resorption Around Total Hip Stems and the Effects of Flexible Materials
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Bone resorption around hip stems is a disturbing phenomenon, although its clinical significance and its eventual effects on replacement longevity are as yet uncertain. The relationship between implant flexibility and the extent of bone loss, frequently established in clinical patient series and animal experiments, does suggest that the changes in bone morphology are an effect of stress shielding and a subsequent adaptive remodeling process. This relationship was investigated using strain-adaptive bone-remodeling theory in combination with finite element models to simulate the bone remodeling process. The effects of stem material flexibility, bone flexibility, and bone reactivity on the process and its eventual outcome were studied. Stem flexibility was also related to proximal implant/bone interface stresses. The results sustain the hypothesis that the resorptive processes are an effect of bone adaptation to stress shielding. The effects of stem flexibility are confirmed by the simulation analysis. It was also established that individual differences in bone reactivity and mechanical bone quality (density and stiffness) may account for the individual variations found in patients and animal experiments. Flexible stems reduce stress shielding and bone resorption. However, they increase proximal interface stresses. Hence, the cure against bone resorption they represent may develop into increased loosening rates because of interface debonding and micromotion. The methods presented in this paper can be used to establish optimal stem-design characteristics or check the adequacy of designs in preclinical testing procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
Self-citationThe Mechanical Adaptations of Bones
Currey, J. D. (1984) · Princeton University Press eBooks · doi:10.1515/9781400853724 · Cited by 896
Bone remodeling I: theory of adaptive elasticity
Cowin, S. C., & Hegedus, D. H. (1976) · Journal of Elasticity · doi:10.1007/bf00041724 · Cited by 665
Carter, D. R., Fyhrie, D. P., & Whalen, R. T. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90058-3 · Cited by 518
Beaupré, G. S., Orr, T. E., & Carter, D. R. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080507 · Cited by 469
Relationships between loading history and femoral cancellous bone architecture
Carter, D. R., Orr, T. E., & Fyhrie, D. P. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90091-2 · Cited by 426
Vital biomechanics: Proposed general concepts for skeletal adaptations to mechanical usage
Frost, H. M. (1988) · Calcified Tissue International · doi:10.1007/bf02556327 · Cited by 355
The Various Stress Patterns of Press-Fit, Ingrown, and Cemented Femoral Stems
HUISKES, R. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199012000-00006 · Cited by 308
Self-citationPorosity and specific surface of bone.
Martin, R. B. (1984) · PubMed · Cited by 295
Huiskes, R., Weinans, H., & Dalstra, M. (1989) · Orthopedics · doi:10.3928/0147-7447-19890901-15 · Cited by 223
Self-citation
Cited by
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
3D bioactive composite scaffolds for bone tissue engineering
Turnbull, G., Clarke, J., Picard, F., Riches, P., Jia, L., Han, F., Li, B., & Shu, W. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.10.001 · Cited by 1,332
Yan, C., Hao, L., Hussein, A., & Young, P. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.06.024 · Cited by 717
Stress shielding and bone resorption in shoulder arthroplasty
Nagels, J., Stokdijk, M., & Rozing, P. M. (2003) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2003.22 · Cited by 707
Bioactive glass scaffolds for bone tissue engineering: state of the art and future perspectives
Fu, Q., Saiz, E., Rahaman, M. N., & Tomsia, A. P. (2011) · Materials Science and Engineering: C · doi:10.1016/j.msec.2011.04.022 · Cited by 703
Additive manufacturing of functionally graded materials: A review
Zhang, C., Chen, F., Huang, Z., Jia, M., Chen, G., Ye, Y., Lin, Y., Liu, W., Chen, B., Shen, Q., et al. (2019) · Materials Science and Engineering: A · doi:10.1016/j.msea.2019.138209 · Cited by 612
Current Strategies to Improve the Bioactivity of PEEK
Ma, R., & Tang, T. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15045426 · Cited by 491
Additive Manufacturing of Titanium Alloys by Electron Beam Melting: A Review
Zhang, L., Liu, Y., Li, S., & Hao, Y. (2018) · Advanced Engineering Materials · doi:10.1002/adem.201700842 · Cited by 486
Mullen, L., Stamp, R. C., Brooks, W. K., Jones, E., & Sutcliffe, C. J. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31219 · Cited by 410
Pedicle screw loosening: a clinically relevant complication?
Galbusera, F., Volkheimer, D., Reitmaier, S., Berger-Roscher, N., Kienle, A., & Wilke, H.-J. (2015) · European Spine Journal · doi:10.1007/s00586-015-3768-6 · Cited by 402
Ahmadi, S., Yavari, S., Wauthle, R., Pouran, B., Schrooten, J., Weinans, H., & Zadpoor, A. (2015) · Materials · doi:10.3390/ma8041871 · Cited by 399
Self-citationBiofilm formation, bacterial adhesion and host response on polymeric implants—issues and prevention
Pavithra, D., & Doble, M. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034003 · Cited by 371
PEEK Dental Implants: A Review of the Literature
Schwitalla, A., & Müller, W.-D. (2013) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-11-00002 · Cited by 340
Mahmoud, D., & Elbestawi, M. (2017) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp1020013 · Cited by 338
Recent Development in Beta Titanium Alloys for Biomedical Applications
Chen, L.-Y., Cui, Y.-W., & Zhang, L.-C. (2020) · Metals · doi:10.3390/met10091139 · Cited by 330
Wang, L., He, S., Wu, X., Liang, S., Mu, Z., Wei, J., Deng, F., Deng, Y., & Wei, S. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.085 · Cited by 303
Bone remodelling in humans is load-driven but not lazy
Christen, P., Ito, K., Ellouz, R., Boutroy, S., Sornay-Rendu, E., Chapurlat, R. D., & van Rietbergen, B. (2014) · Nature Communications · doi:10.1038/ncomms5855 · Cited by 281
Biomedical titanium alloys and their additive manufacturing
Hao, Y., Li, S., & Yang, R. (2016) · Rare Metals · doi:10.1007/s12598-016-0793-5 · Cited by 267
Finite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
Bioinspired Strong and Highly Porous Glass Scaffolds
Fu, Q., Saiz, E., & Tomsia, A. P. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002030 · Cited by 252
Bone and metal: An orthopaedic perspective on osseointegration of metals
Goriainov, V., Cook, R., M. Latham, J., G. Dunlop, D., & Oreffo, R. O. C. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.004 · Cited by 223
Failed innovation in total hip replacement: Diagnosis and proposals for a cure
Huiskes, R. (1993) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679308994602 · Cited by 215
Self-citationTailoring Selective Laser Melting Process Parameters for NiTi Implants
Bormann, T., Schumacher, R., Müller, B., Mertmann, M., & de Wild, M. (2012) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-012-0318-9 · Cited by 212
Vijayavenkataraman, S., Kuan, L. Y., & Lu, W. F. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108602 · Cited by 200
Taylor, M., & Prendergast, P. J. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.019 · Cited by 199
Arabnejad Khanoki, S., & Pasini, D. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006115 · Cited by 192
Rh. Owen, G., Dard, M., & Larjava, H. (2018) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.34049 · Cited by 187
Jaecques, S. V. N., Van Oosterwyck, H., Muraru, L., Van Cleynenbreugel, T., De Smet, E., Wevers, M., Naert, I., & Vander Sloten, J. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00516-7 · Cited by 186
Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants
Amini, A. R., Wallace, J. S., & Nukavarapu, S. P. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i2.10 · Cited by 181
Nanomodified Peek Dental Implants: Bioactive Composites and Surface Modification—A Review
Najeeb, S., Khurshid, Z., Matinlinna, J. P., Siddiqui, F., Nassani, M. Z., & Baroudi, K. (2015) · International Journal of Dentistry · doi:10.1155/2015/381759 · Cited by 175
Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone
Converse, G. L., Yue, W., & Roeder, R. K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.031 · Cited by 169
Frontiers in high entropy alloys and high entropy functional materials
Zhang, W., Wang, X., Zhang, F., Cui, X., Fan, B., Guo, J., Guo, Z., Huang, R., Huang, W., Li, X., et al. (2024) · Rare Metals · doi:10.1007/s12598-024-02852-0 · Cited by 169
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102
Metadata
- Authors
- HUISKES, R., WEINANS, H., & RIETBERGEN, B. V.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1992-01
- Volume
- 274
- Issue
- 274
- Pages
- 124???134
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2128690996
- Cited by
- 1,213
- References
- 13
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.