Cellular Uptake and Trafficking of a Prototypical Magnetic Iron Oxide Label In Vitro
The DOI matches its Crossref record.
Abstract
RATIONALE AND OBJECTIVES: Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of some target-specific MR contrast agents. METHODS: The prototypical agent (RMA) consisted of a dextran-coated monocrystalline iron oxide that was modified with rhodamine (fluorescent label) and opsonized with albumin. Fluorescence microscopy was performed in a phagocytic C6 cell line and in murine bone marrow macrophages. Immunohistochemistry against lysosomal markers was used to confirm the intracellular location of the label. RESULTS: RMA was identified inside cells after incubation at concentrations as low as 4.0 x 10(-10) M Fe, typically observed with receptor mediated endocytosis and several orders of magnitude lower than that expected with fluid phase pinocytosis. Cell uptake could be inhibited by excess protein but not by dextran. RMA localized initially to tubular and to round intracellular organelles and co-localized with an antibody against a murine lysosomal glycoprotein antibodies (LGP-A) in macrophages. Three days after incubation, RMA was concentrated in perinuclear vesicles, which most likely represent terminal lysosomes where final breakdown appears to occur. CONCLUSIONS: The mechanism of cellular uptake of a prototypical opsonized iron oxide label is consistent with receptor-mediated endocytosis. Immediately after cell contact, RMA localizes to the lysosomal compartment and at long time points reside in vesicles that by morphology and distribution appear to be terminal lysosomes. Iron oxides therefore demonstrate metabolism via the lysosomal pathway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Cytotoxicity of Colloidal CdSe and CdSe/ZnS Nanoparticles
Kirchner, C., Liedl, T., Kudera, S., Pellegrino, T., Muñoz Javier, A., Gaub, H. E., Stölzle, S., Fertig, N., & Parak, W. J. (2005) · Nano Letters · doi:10.1021/nl047996m · Cited by 1,619
Functionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460
Brunner, T. J., Wick, P., Manser, P., Spohn, P., Grass, R. N., Limbach, L. K., Bruinink, A., & Stark, W. J. (2006) · Environmental Science & Technology · doi:10.1021/es052069i · Cited by 1,385
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Potential toxicity of superparamagnetic iron oxide nanoparticles (SPION)
Singh, N., Jenkins, G. J. S., Asadi, R., & Doak, S. H. (2010) · Nano Reviews · doi:10.3402/nano.v1i0.5358 · Cited by 1,112
Imaging macrophages with nanoparticles
Weissleder, R., Nahrendorf, M., & Pittet, M. J. (2014) · Nature Materials · doi:10.1038/nmat3780 · Cited by 809
Biodistribution, Clearance, and Biocompatibility of Iron Oxide Magnetic Nanoparticles in Rats
Jain, T. K., Reddy, M. K., Morales, M. A., Leslie-Pelecky, D. L., & Labhasetwar, V. (2008) · Molecular Pharmaceutics · doi:10.1021/mp7001285 · Cited by 705
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Wilhelm, C., Billotey, C., Roger, J., Pons, J. N., Bacri, J.-C., & Gazeau, F. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00440-4 · Cited by 675
Interaction of Nanoparticles with Cells
Mailänder, V., & Landfester, K. (2009) · Biomacromolecules · doi:10.1021/bm900266r · Cited by 576
Forming Biocompatible and Nonaggregated Nanocrystals in Water Using Amphiphilic Polymers
Yu, W. W., Chang, E., Falkner, J. C., Zhang, J., Al-Somali, A. M., Sayes, C. M., Johns, J., Drezek, R., & Colvin, V. L. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067184n · Cited by 521
Labelling of cells with quantum dots
Parak, W. J., Pellegrino, T., & Plank, C. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/2/r01 · Cited by 475
Nanoparticles for biomedical imaging
Nune, S. K., Gunda, P., Thallapally, P. K., Lin, Y.-Y., Laird Forrest, M., & Berkland, C. J. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240903229031 · Cited by 450
Raynal, I., Prigent, P., Peyramaure, S., Najid, A., Rebuzzi, C., & Corot, C. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000101027.57021.28 · Cited by 403
Review of Green Methods of Iron Nanoparticles Synthesis and Applications
Fahmy, H. M., Mohamed, F. M., Marzouq, M. H., Mustafa, A. B. E.-D., Alsoudi, A. M., Ali, O. A., Mohamed, M. A., & Mahmoud, F. A. (2018) · BioNanoScience · doi:10.1007/s12668-018-0516-5 · Cited by 390
Evaluation of Quantum Dot Cytotoxicity Based on Intracellular Uptake
Chang, E., Thekkek, N., Yu, W. W., Colvin, V. L., & Drezek, R. (2006) · Small · doi:10.1002/smll.200600218 · Cited by 370
Effect of Nanoparticles on the Cell Life Cycle
Mahmoudi, M., Azadmanesh, K., Shokrgozar, M. A., Journeay, W. S., & Laurent, S. (2011) · Chemical Reviews · doi:10.1021/cr1003166 · Cited by 352
Arbab, A. S., Wilson, L. B., Ashari, P., Jordan, E. K., Lewis, B. K., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.970 · Cited by 347
Tumoral Distribution of Long-circulating Dextran-coated Iron Oxide Nanoparticles in a Rodent Model
Moore, A., Marecos, E., Bogdanov, A., & Weissleder, R. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe19568 · Cited by 343
Self-citationMagnetically labeled cells can be detected by MR imaging
Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070140 · Cited by 336
Self-citationCell response to dextran-derivatised iron oxide nanoparticles post internalisation
Berry, C. C., Wells, S., Charles, S., Aitchison, G., & Curtis, A. S. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.046 · Cited by 313
Lorenz, M. R., Holzapfel, V., Musyanovych, A., Nothelfer, K., Walther, P., Frank, H., Landfester, K., Schrezenmeier, H., & Mailänder, V. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.022 · Cited by 292
Biodegradation of Iron Oxide Nanocubes: High-Resolution In Situ Monitoring
Lartigue, L., Alloyeau, D., Kolosnjaj-Tabi, J., Javed, Y., Guardia, P., Riedinger, A., Péchoux, C., Pellegrino, T., Wilhelm, C., & Gazeau, F. (2013) · ACS Nano · doi:10.1021/nn305719y · Cited by 274
Uptake of dextran‐coated monocrystalline iron oxides in tumor cells and macrophages
Moore, A., Weissleder, R., & Bogdanov, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070629 · Cited by 260
Self-citationMüller, K., Skepper, J. N., Posfai, M., Trivedi, R., Howarth, S., Corot, C., Lancelot, E., Thompson, P. W., Brown, A. P., & Gillard, J. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.12.003 · Cited by 236
“73 M Fe for up to 10 days [26].”
BackgroundMagnetic iron oxide nanoparticles as T1contrast agents for magnetic resonance imaging
Bao, Y., Sherwood, J. A., & Sun, Z. (2018) · Journal of Materials Chemistry C · doi:10.1039/c7tc05854c · Cited by 217
Stroh, A., Zimmer, C., Gutzeit, C., Jakstadt, M., Marschinke, F., Jung, T., Pilgrimm, H., & Grune, T. (2004) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2004.01.016 · Cited by 202
Lévy, M., Lagarde, F., Maraloiu, V.-A., Blanchin, M.-G., Gendron, F., Wilhelm, C., & Gazeau, F. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/39/395103 · Cited by 193
“Once injected in the organism, they are readily captured by resident or circulating macrophages and internalized into lysosomes [16], which are specialized intracellular organelles in charge of digesting non-usable substances [17].”
BackgroundOxidative Stress Induced in Microorganisms by Zero-valent Iron Nanoparticles
Ševců, A., El-Temsah, Y. S., Joner, E. J., & Černík, M. (2011) · Microbes and Environments · doi:10.1264/jsme2.me11126 · Cited by 175
“The latter situation is possible because nZVI can be actively internalized via endocytosis (91, 106).”
BackgroundMeasuring transferrin receptor gene expression by NMR imaging
Moore, A., Basilion, J. P., Chiocca, E. A., & Weissleder, R. (1998) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/s0167-4889(98)00002-0 · Cited by 174
Self-citationLandfester, K., Musyanovych, A., & Mailänder, V. (2010) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.23786 · Cited by 173
Morishige, K., Kacher, D. F., Libby, P., Josephson, L., Ganz, P., Weissleder, R., & Aikawa, M. (2010) · Circulation · doi:10.1161/circulationaha.109.891804 · Cited by 168
Self-citationAhrens, E. T., Feili‐Hariri, M., Xu, H., Genove, G., & Morel, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10465 · Cited by 168
Clinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Metadata
- Authors
- SCHULZE, E., FERRUCCI, J. T., POSS, K., LAPOINTE, L., BOGDANOVA, A., & WEISSLEDER, R.
- Venue
- Investigative Radiology
- Published
- 1995-10
- Volume
- 30
- Issue
- 10
- Pages
- 604-610
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2036116957
- Cited by
- 142
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.