The DOI matches its Crossref record; 146 of the 146 references it cites were found in a registry or an index.
Medical ultrasound: imaging of soft tissue strain and elasticity
Open accessAbstract
After X-radiography, ultrasound is now the most common of all the medical imaging technologies. For millennia, manual palpation has been used to assist in diagnosis, but it is subjective and restricted to larger and more superficial structures. Following an introduction to the subject of elasticity, the elasticity of biological soft tissues is discussed and published data are presented. The basic physical principles of pulse-echo and Doppler ultrasonic techniques are explained. The history of ultrasonic imaging of soft tissue strain and elasticity is summarized, together with a brief critique of previously published reviews. The relevant techniques—low-frequency vibration, step, freehand and physiological displacement, and radiation force (displacement, impulse, shear wave and acoustic emission)—are described. Tissue-mimicking materials are indispensible for the assessment of these techniques and their characteristics are reported. Emerging clinical applications in breast disease, cardiology, dermatology, gastroenterology, gynaecology, minimally invasive surgery, musculoskeletal studies, radiotherapy, tissue engineering, urology and vascular disease are critically discussed. It is concluded that ultrasonic imaging of soft tissue strain and elasticity is now sufficiently well developed to have clinical utility. The potential for further research is examined and it is anticipated that the technology will become a powerful mainstream investigative tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Materials science and engineering: An introduction
Clayton, C. R. (1987) · Materials Science and Engineering · doi:10.1016/0025-5416(87)90343-0 · Cited by 5,925
Materials Science and Engineering: An Introduction
Callister, W. D. (1985) · Cited by 5,351
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Duck, F. A. (1990) · Cited by 2,727
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Zeng, X., Liu, H., Chu, M. G., & Lavernia, E. J. (1992) · Metallurgical Transactions A · doi:10.1007/bf02663451 · Cited by 1,519
Ziol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, H. L.-Y., Le Bail, B., Choi, P. C.-L., Kowo, M., Chan, A. W.-H., Merrouche, W., et al. (2010) · Hepatology · doi:10.1002/hep.23312 · Cited by 1,322
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
D'hooge, J. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0031 · Cited by 990
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Sasso, M., Beaugrand, M., de Ledinghen, V., Douvin, C., Marcellin, P., Poupon, R., Sandrin, L., & Miette, V. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.005 · Cited by 862
High intensity focused ultrasound: Physical principles and devices
ter Haar, >., & Coussios, C. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601186138 · Cited by 805
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Gennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683
Quantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Selected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
Ultrasound-Stimulated Vibro-Acoustic Spectrography
Fatemi, M., & Greenleaf, J. F. (1998) · Science · doi:10.1126/science.280.5360.82 · Cited by 642
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
Marcellin, P., Ziol, M., Bedossa, P., Douvin, C., Poupon, R., De Lédinghen, V., & Beaugrand, M. (2009) · Liver International · doi:10.1111/j.1478-3231.2008.01802.x · Cited by 535
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Perk, G., Tunick, P. A., & Kronzon, I. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.08.023 · Cited by 501
“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
Assessment of the distensibility of superficial arteries
Hoeks, A. P. G., Brands, P. J., Smeets, F. A. M., & Reneman, R. S. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90139-4 · Cited by 479
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Ultrasonic imaging of internal vibration of soft tissue under forced vibration
Yamakoshi, Y., Sato, J., & Sato, T. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.46969 · Cited by 474
Elastic modulus measurements of human liver and correlation with pathology
Yeh, W.-C., Li, P.-C., Jeng, Y.-M., Hsu, H.-C., Kuo, P.-L., Li, M.-L., Yang, P.-M., & Lee, P. H. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00489-1 · Cited by 458
Colour doppler velocity imaging of the myocardium
McDicken, W. N., Sutherland, G. R., Moran, C. M., & Gordon, L. N. (1992) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(92)90080-t · Cited by 446
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Assessment of biliary fibrosis by transient elastography in patients with PBC and PSC
Corpechot, C., El Naggar, A., Poujol-Robert, A., Ziol, M., Wendum, D., Chazouillères, O., de Lédinghen, V., Dhumeaux, D., Marcellin, P., Beaugrand, M., et al. (2006) · Hepatology · doi:10.1002/hep.21151 · Cited by 441
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Shear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412
Muller, M., Gennisson, J.-L., Deffieux, T., Tanter, M., & Fink, M. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.08.018 · Cited by 400
In vivo real-time freehand palpation imaging
Hall, T. J., Zhu, Y., & Spalding, C. S. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00733-0 · Cited by 394
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Krouskop, T. A., Dougherty, D. R., & Vinson, F. S. (1987) · PubMed · Cited by 362
Quantitative Assessment of Arterial Wall Biomechanical Properties Using Shear Wave Imaging
Couade, M., Pernot, M., Prada, C., Messas, E., Emmerich, J., Bruneval, P., Criton, A., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.004 · Cited by 348
Ter Haar, G. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02010-1 · Cited by 330
Young's modulus measurements of soft tissues with application to elasticity imaging
Chen, E. J., Novakofski, J., Jenkins, W. K., & O'Brien, W. D. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.484478 · Cited by 312
Magnetic Resonance–Guided Focused Ultrasound Surgery of Breast Cancer: Reliability and Effectiveness
Furusawa, H., Namba, K., Thomsen, S., Akiyama, F., Bendet, A., Tanaka, C., Yasuda, Y., & Nakahara, H. (2006) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2006.04.002 · Cited by 304
Tissue elasticity properties as biomarkers for prostate cancer
Hoyt, K., Castaneda, B., Zhang, M., Nigwekar, P., di Sant'Agnese, P. A., Joseph, J. V., Strang, J., Rubens, D. J., & Parker, K. J. (2008) · Cancer Biomarkers · doi:10.3233/cbm-2008-44-505 · Cited by 303
Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging
Burnside, E. S., Hall, T. J., Sommer, A. M., Hesley, G. K., Sisney, G. A., Svensson, W. E., Fine, J. P., Jiang, J., & Hangiandreou, N. J. (2007) · Radiology · doi:10.1148/radiol.2452061805 · Cited by 296
Measuring the elastic modulus of ex vivo small tissue samples
Samani, A., Bishop, J., Luginbuhl, C., & Plewes, D. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/310 · Cited by 295
Wells, P. N. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r06 · Cited by 287
Self-citationGennisson, J.-L., Catheline, S., Chaffaı̈, S., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1579008 · Cited by 272
Idiopathic inflammatory myopathies: epidemiology, classification, and diagnostic criteria
Mastaglia, F. L., & Phillips, B. A. (2002) · Rheumatic Disease Clinics of North America · doi:10.1016/s0889-857x(02)00021-2 · Cited by 263
Bercoff, J., Tanter, M., Muller, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1367494 · Cited by 245
Assessment of liver fibrosis using transient elastography in patients with alcoholic liver disease
Nahon, P., Kettaneh, A., Tengher-Barna, I., Ziol, M., de Lédinghen, V., Douvin, C., Marcellin, P., Ganne-Carrié, N., Trinchet, J.-C., & Beaugrand, M. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.08.011 · Cited by 233
Drakonaki, E. E., Allen, G. M., & Wilson, D. J. (2009) · Clinical Radiology · doi:10.1016/j.crad.2009.08.006 · Cited by 230
Lopata, R. G. P., Nillesen, M. M., Hansen, H. H. G., et al. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.11.002 · Cited by 228
Lerner, R. M., Parker, K. J., Holen, J., Gramiak, R., & Waag, R. C. (1988) · Acoustical Imaging · doi:10.1007/978-1-4613-0725-9_31 · Cited by 220
Sonoelastic determination of human skeletal muscle elasticity
Levinson, S. F., Shinagawa, M., & Sato, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00173-2 · Cited by 203
Reduction of Image Noise in Elastography
Céspedes, I., & Ophir, J. (1993) · Ultrasonic Imaging · doi:10.1177/016173469301500202 · Cited by 199
An adaptive strain estimator for elastography
Alam, S. K., Ophir, J., & Konofagou, E. E. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.660156 · Cited by 198
The Cambridge Illustrated History of Medicine
(1996) · Nature Medicine · doi:10.1038/nm1196-1269 · Cited by 196
Real-Time Sonoelastography Findings in Healthy Achilles Tendons
De Zordo, T., Fink, C., Feuchtner, G. M., Smekal, V., Reindl, M., & Klauser, A. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1843 · Cited by 195
A 40–100 MHz B-scan ultrasound backscatter microscope for skin imaging
Turnbull, D. H., Starkoski, B. G., Harasiewicz, K. A., Semple, J. L., From, L., Gupta, A. K., Sauder, D. N., & Foster, F. S. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00083-2 · Cited by 194
Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms
de Korte, C. L., Céspedes, E. I., van der Steen, A. F. W., et al. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00004-5 · Cited by 191
Physics of Vibrations in Living Tissues
von Gierke, H. E., Oestreicher, H. L., Franke, E. K., Parrack, H. O., & von Wittern, W. W. (1952) · Journal of Applied Physiology · doi:10.1152/jappl.1952.4.12.886 · Cited by 188
Measurement of soft tissue motion using correlation between A-scans
Dickinson, R. J., & Hill, C. R. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(82)90032-1 · Cited by 186
A method of imaging viscoelastic parameters with acoustic radiation force
Walker, W. F., Fernandez, F. J., & Negron, L. A. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/303 · Cited by 176
Characterization of plaque components and vulnerability with intravascular ultrasound elastography
Korte, C. L. D., Steen, A. F. W. V. D., Céspedes, E. I., Pasterkamp, G., Carlier, S. G., Mastik, F., Schoneveld, A. H., Serruys, P. W., & Bom, N. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/305 · Cited by 175
Gennisson, J. L., Cornu, C., Catheline, S., Fink, M., & Portero, P. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.013 · Cited by 173
Ultrasonic measurement of small displacements and deformations of tissue
Wilson, L. (1982) · Ultrasonic Imaging · doi:10.1016/0161-7346(82)90006-2 · Cited by 172
Quantitative elasticity imaging: what can and cannot be inferred from strain images
Barbone, P. E., & Bamber, J. C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/310 · Cited by 171
Varghese, T., Zagzebski, J. A., & Lee, F. T. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00656-7 · Cited by 169
Elen, A., Choi, H. F., Loeckx, D., Gao, H., Claus, P., Suetens, P., Maes, F., & D'hooge, J. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004420 · Cited by 169
Quasi-Static Ultrasound Elastography
Varghese, T. (2009) · Ultrasound Clinics · doi:10.1016/j.cult.2009.10.009 · Cited by 169
Three-dimensional sonoelastography: principles and practices
Taylor, L. S., Porter, B. C., Rubens, D. J., & Parker, K. J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/306 · Cited by 168
Vibro-acoustic tissue mammography
Fatemi, M., Wold, L. E., Alizad, A., & Greenleaf, J. F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.981229 · Cited by 155
On the thermal effects associated with radiation force imaging of soft tissue
Palmeri, M. L., & Nightingale, K. R. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320828 · Cited by 155
Assessment of elastic parameters of human skin using dynamic elastography
Gennisson, J., Baldeweck, T., Tanter, M., Catheline, S., Fink, M., Sandrin, L., Cornillon, C., & Querleux, B. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1324402 · Cited by 154
Tissue hardness measurement using the radiation force of focused ultrasound
Sugimoto, T., Ueha, S., & Itoh, K. (1990) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1990.171591 · Cited by 153
AAPM/RSNA Physics Tutorial for Residents: Topics in US
Hall, T. J. (2003) · Radiographics · doi:10.1148/rg.236035163 · Cited by 152
An analysis of elastographic contrast-to-noise ratio
Varghese, T., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00047-7 · Cited by 151
Doyley, M. M., Bamber, J. C., Fuechsel, F. G., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00429-x · Cited by 149
Ribbers, H., Lopata, R. G. P., Holewijn, S., Pasterkamp, G., Blankensteijn, J. D., & de Korte, C. L. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.09.009 · Cited by 149
Fundamental mechanical limitations on the visualization of elasticity contrast in elastography
Ponnekanti, H., Ophir, J., Huang, Y., et al. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00136-2 · Cited by 147
A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue
Han, L., Noble, J. A., & Burcher, M. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00776-7 · Cited by 146
Cédric Schmitt, A., Soulez, G., Maurice, R. L., Giroux, M.-F., & Cloutier, G. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.05.020 · Cited by 146
Quantitative sonoelastography for thein vivoassessment of skeletal muscle viscoelasticity
Hoyt, K., Kneezel, T., Castañeda, B., & Parker, K. J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/004 · Cited by 145
A unified view of imaging the elastic properties of tissue
Parker, K. J., Taylor, L. S., Gracewski, S. M., & Rubens, D. J. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1880772 · Cited by 142
Fundamental limitations on the contrast-transfer efficiency in elastography: An analytic study
Kallel, F., Bertrand, M. J., & Ophir, J. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02079-9 · Cited by 138
Poroelastography: imaging the poroelastic properties of tissues
Konofagou, E. E., Harrigan, T. P., Ophir, J., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00433-1 · Cited by 135
A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound
Brands, P. J., Willigers, J. M., Ledoux, L. A. F., Reneman, R. S., & Hoeks, A. P. G. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00126-4 · Cited by 131
Wu, Z., Taylor, L. S., Rubens, D. J., & Parker, K. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/6/003 · Cited by 130
Săftoiu, A., & Vilman, P. (2006) · PubMed · Cited by 127
Axial resolution in elastography
Righetti, R., Ophir, J., & Ktonas, P. Y. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00495-1 · Cited by 127
The feasibility of using elastography for imaging the Poisson's ratio in porous media
Righetti, R., Ophir, J., Srinivasan, S., et al. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.10.022 · Cited by 126
Shear-Modulus Estimation by Application of Spatially-Modulated Impulsive Acoustic Radiation Force
McAleavey, S. A., Menon, M., & Orszulak, J. (2007) · Ultrasonic Imaging · doi:10.1177/016173460702900202 · Cited by 122
Alam, S. K., & Ophir, J. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00164-0 · Cited by 121
Havre, R. F., Elde, E., Gilja, O. H., Ødegaard, S., Eide, G. E., Matre, K., & Nesje, L. B. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.03.009 · Cited by 121
Noise reduction in elastograms using temporal stretching with multicompression averaging
Varghese, T., Ophir, J., & Céspedes, I. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00128-7 · Cited by 119
Shear modulus reconstruction in dynamic elastography: time harmonic case
Park, E., & Maniatty, A. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/007 · Cited by 114
Direct strain estimation in elastography using spectral cross-correlation
Varghese, T., Konofagou, E. E., Jonathan Ophir, A., Alam, S. K., & Bilgen, M. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00316-1 · Cited by 114
Ultrasonic and viscoelastic properties of skin under transverse mechanical stress in vitro
Pan, L., Zan, L., & Foster, F. S. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00071-4 · Cited by 114
Lateral speckle tracking using synthetic lateral phase
Chen, X., Zohdy, M. J., Emelianov, S., et al. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320827 · Cited by 110
Real-Time Ultrasound Elasticity of the Breast: Initial Clinical Results
Barr, R. G. (2010) · Ultrasound Quarterly · doi:10.1097/ruq.0b013e3181dc7ce4 · Cited by 109
Mechanical properties of vertebrate hard tissues
Currey, J. D. (1998) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411981534178 · Cited by 106
Ahn, B., Kim, J., Ian, L. R., Rha, K. H., & Kim, H. J. (2010) · Urology · doi:10.1016/j.urology.2010.02.025 · Cited by 95
Spalazzi, J. P., Gallina, J., Fung-Kee-Fung, S., Konofagou, E. E., & Lu, H. H. (2006) · Journal of Orthopaedic Research® · doi:10.1002/jor.20260 · Cited by 95
Reconstructive elasticity imaging for large deformations
Skovoroda, A. R., Lubinski, L. A., Emelianov, S., & O’Donnell, M. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764839 · Cited by 90
Advancing intravascular ultrasonic palpation toward clinical applications
Doyley, M. M., Mastik, F., de Korte, C. L., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00457-4 · Cited by 88
Miller, N. R., Bamber, J. C., & ter Haar, G. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.11.016 · Cited by 83
Trade-offs between the axial resolution and the signal-to-noise ratio in elastography
Srinivasan, S. S., Righetti, R., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00037-1 · Cited by 81
RF-based two-dimensional cardiac strain estimation: a validation study in a tissue-mimicking phantom
Langeland, S., D’hooge, J., Claessens, T. E., et al. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1367495 · Cited by 79
Dynamic tests in real-time breast echography
Ueno, E., Tohno, E., Soeda, S., Asaoka, Y., Itoh, K., Bamber, J. C., Blaszqzyk, M., Davey, J. B., & McKinna, J. A. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90047-6 · Cited by 78
New methods for arterial diameter measurement from B-mode images
Stadler, R. W., Karl, W. C., & Lees, R. S. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02017-9 · Cited by 78
Multiresolution imaging in elastography
Varghese, T., Bilgen, M., & Ophir, J. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.646912 · Cited by 77
Effects of Various Parameters on Lateral Displacement Estimation in Ultrasound Elastography
Luo, J., & Konofagou, E. E. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.03.001 · Cited by 75
Lateral resolution in elastography
Righetti, R., Srinivasan, S., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00028-0 · Cited by 74
Prostate Cancer: Three-dimensional Sonoelastography for in Vitro Detection
Taylor, L. S., Rubens, D. J., Porter, B. C., Wu, Z., Baggs, R. B., di Sant'Agnese, P. A., Nadasdy, G. M., Pasternack, D., Messing, E. M., Nigwekar, P., et al. (2005) · Radiology · doi:10.1148/radiol.2373041573 · Cited by 74
A Generalized Speckle Tracking Algorithm for Ultrasonic Strain Imaging Using Dynamic Programming
Jiang, J., & Hall, T. J. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.05.016 · Cited by 71
Acoustic shear-wave imaging using echo ultrasound compared to magnetic resonance elastography
Dutt, V., Kinnick, R. R., Muthupillai, R., Oliphant, T. E., Ehman, R. L., & Greenleaf, J. F. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00166-0 · Cited by 70
Vogt, M., & Ermert, H. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1417260 · Cited by 69
Acoustic Radiation Force Impulse Imaging of Human Prostates Ex Vivo
Zhai, L., Madden, J. F., Foo, W., Palmeri, M. L., MOURAVIEV, V. B., Polascik, T. J., & Nightingale, K. R. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.12.006 · Cited by 68
Bubble-based acoustic radiation force elasticity imaging
Erpelding, T. N., Hollman, K. W., & O’Donnell, M. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1504019 · Cited by 62
Non-invasive quantitative reconstruction of tissue elasticity using an iterative forward approach
Fu, D., Levinson, S. F., Gracewski, S. M., & Parker, K. J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/307 · Cited by 57
Random noise in ultrasonic echoes diffracted by blood
Atkinson, P. J., & Berry, M. (1974) · Journal of Physics A Mathematical Nuclear and General · doi:10.1088/0305-4470/7/11/009 · Cited by 57
In Vivo Vibroacoustography of Large Peripheral Arteries
Pislaru, C., Kantor, B., Kinnick, R. R., Anderson, J., Aubry, M. C., Urban, M. W., Fatemi, M., & Greenleaf, J. F. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e31816085fc · Cited by 56
Strain imaging of internal deformation
Mai, J. J., & Insana, M. F. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00645-2 · Cited by 45
New Fabrication Techniques for Ring-Array Transducers for Real-Time 3D Intravascular Ultrasound
Light, E. D., Lieu, V., & Smith, S. W. (2009) · Ultrasonic Imaging · doi:10.1177/016173460903100403 · Cited by 40
Elasticity Imaging Using Conventional and High-Frame Rate Ultrasound Imaging: Experimental Study
Park, S., Aglyamov, S. R., & Emelianov, S. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.529 · Cited by 39
A zero-crossing strain estimator for elastography
Srinivasan, S. S., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00697-x · Cited by 38
A tutorial on ultrasonic physics and imaging techniques
Halliwell, M. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim656 · Cited by 34
Doppler ultrasound imaging of magnetically vibrated brachytherapy seeds
McAleavey, S. A., Rubens, D. J., & Parker, K. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.807644 · Cited by 33
In Vitro Uterine Strain Imaging: Preliminary Results
Hobson, M. A., Kiss, M. Z., Varghese, T., Sommer, A. M., Kliewer, M. A., Zagzebski, J. A., Hall, T. J., Harter, J. M., Hartenbach, E. M., & Madsen, E. L. (2007) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2007.26.7.899 · Cited by 32
Optimizing multicompression approaches to elasticity imaging
Du, H., Liu, J., Pellot-Barakat, C. J. M., et al. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1588394 · Cited by 24
Estimating the elastographic signal-to-noise ratio using correlation coefficients
Srinivasan, S. S., Kallel, F., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00510-5 · Cited by 23
The effects of digitization on the elastographic signal-to-noise ratio
Srinivasan, S. S., Kallel, F., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00652-x · Cited by 22
Srinivasan, S. S., Ophir, J., & Alam, S. K. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.07.013 · Cited by 18
Investigation of parametric spectral estimation techniques for elasticity imaging
Hoyt, K., Forsberg, F., & Ophir, J. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.04.013 · Cited by 11
Liang, H., Zhou, L., Wells, P. N. T., et al. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.10.017 · Cited by 5
Self-citation
Cited by
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Shiina, T., Nightingale, K. R., Palmeri, M. L., Hall, T. J., Bamber, J. C., Barr, R. G., Castera, L., Choi, B. I., Chou, Y.-H., Cosgrove, D., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.009 · Cited by 958
Biomedicine Meets Fenton Chemistry
Tang, Z., Zhao, P., Wang, H., Liu, Y., & Bu, W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00977 · Cited by 745
Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S. (2017) · RadioGraphics · doi:10.1148/rg.2017160116 · Cited by 729
Ferraioli, G., Tinelli, C., Dal Bello, B., Zicchetti, M., Filice, G., Filice, C., & on behalf of the Liver Fibrosis Study Group (2012) · Hepatology · doi:10.1002/hep.25936 · Cited by 667
Metadata
- Authors
- Wells, P. N. T., & Liang, H.-D.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2011-06-16
- Volume
- 8
- Issue
- 64
- Pages
- 1521-1549
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2163357879
- Cited by
- 538
- References
- 146
- FWCI
- 25.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.