A flexible method for fabrication of nerve cuff electrodes
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A method for construction of cuff electrodes is presented. The method is based on using platinum foil electrodes fixed by rubber bands on a Teflon coated mandrel, that is then dip-coated with silicone. The method allows for design of cuff electrodes of practically any size, shape and electrode configuration, and simple cuffs can be built in less than one hour of work Cuff electrodes have been built that range in size from 0.5 to 10 mm ID and 5 to 70 mm length and number of electrodes from one to twelve. Tri-polar recording electrodes have been tested in more than 30 chronic implantations in rabbits (tibial nerve) and for various acute experiments, where different electrode configurations were investigated. None of the chronic implants have failed and impedances have been stable for one year.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Cited by
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
“were used by Hoffer and Haugland [25], [26].”
MethodSensory input to primate spinal cord is presynaptically inhibited during voluntary movement
Seki, K., Perlmutter, S. I., & Fetz, E. E. (2003) · Nature Neuroscience · doi:10.1038/nn1154 · Cited by 294
“in combination with nerve cuff electrodes to stimulate and record from a peripheral nerv”
BackgroundCuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Larsen, J. O., Thomsen, M., Haugland, M., & Sinkjær, T. (1998) · Acta Neuropathologica · doi:10.1007/s004010050907 · Cited by 96
“A platinum reference electrode was mounted on the outside wall (see [ 7 ] for a detailed description).”
MethodSelf-citationKundu, A., Harreby, K. R., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2267936 · Cited by 83
Closed-loop control of the heart rate by electrical stimulation of the vagus nerve
Tosato, M., Yoshida, K., Toft, E., Nekrasas, V., & Struijk, J. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0037-1 · Cited by 78
“Two custom-made silicone tripolar cuff electrodes ([ 16 ], dimensions: 3.4 mm inner diameter, 1 mm wide platinum rings, 4 mm spaced) were placed around each vagus nerve, with the interelectrode distance ranging from 40 mm to 60 mm. On each nerve, the distal electrode set was used for stimulation, and the proximal for…”
MethodInfluentialPeripheral nerve bionic interface: a review of electrodes
Russell, C., Roche, A. D., & Chakrabarty, S. (2019) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-019-00086-3 · Cited by 67
Foldes, E. L., Ackermann, D. M., Bhadra, N., Kilgore, K. L., & Bhadra, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.020 · Cited by 61
“Many cuff-type electrode designs have proven to provide this by using a cylindrical geometry to conform to the shape of the nerve, encircling the nerve trunk (McCarty, 1965; Gardiner, 1967; Dubkin, 1970; Haugland, 1996; Rushton, 1997; Hoffer and Kallesoe, 1999; Rutten, 2002).”
BackgroundMicera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
Cavallaro, E., Micera, S., Dario, P., Jensen, W., & Sinkjaer, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816075 · Cited by 44
Jensen, W., Sinkjaer, T., & Sepulveda, F. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802851 · Cited by 26
Dweiri, Y. M., Stone, M. A., Tyler, D. J., McCallum, G. A., & Durand, D. M. (2016) · Journal of Visualized Experiments · doi:10.3791/54388 · Cited by 23
How to Use Nerve Cuffs to Stimulate, Record or Modulate Neural Activity
Hoffer, J.-A., & Kallesøe, K. (2000) · Frontiers in Neuroscience · doi:10.1201/9781420039054.ch5 · Cited by 21
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278479 · Cited by 15
Fascicle-Selectivity of an Intraneural Stimulation Electrode in the Rabbit Sciatic Nerve
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2169671 · Cited by 11
Metadata
- Authors
- Haugland, M.
- Venue
- Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2002-12-24
- Volume
- 1
- Pages
- 359-360
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2114660389
- Cited by
- 79
- References
- 1
- FWCI
- 22.34
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.