A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
A power-efficient wireless stimulating system for a head-mounted deep brain stimulator (DBS) is presented. A new adaptive rectifier generates a variable DC supply voltage from a constant AC power carrier utilizing phase control feedback, while achieving high AC-DC power conversion efficiency (PCE) through active synchronous switching. A current-controlled stimulator adopts closed-loop supply control to automatically adjust the stimulation compliance voltage by detecting stimulation site potentials through a voltage readout channel, and improve the stimulation efficiency. The stimulator also utilizes closed-loop active charge balancing to maintain the residual charge at each site within a safe limit, while receiving the stimulation parameters wirelessly from the amplitude-shift-keyed power carrier. A 4-ch wireless stimulating system prototype was fabricated in a 0.5-μm 3M2P standard CMOS process, occupying 2.25 mm2. With 5 V peak AC input at 2 MHz, the adaptive rectifier provides an adjustable DC output between 2.5 V and 4.6 V at 2.8 mA loading, resulting in measured PCE of 72 ~ 87%. The adaptive supply control increases the stimulation efficiency up to 30% higher than a fixed supply voltage to 58 ~ 68%. The prototype wireless stimulating system was verified in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 3×
“Deep brain stimulation (DBS) is one of the most effective examples of such therapies to treat Parkinson’s disease, tremor, and dystonia [4], [5].”
BackgroundCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868 · cited 1×
“A head-mounted DBS can eliminate hardship imposed by chest-implanted primary batteries and long interconnects across the neck, replacing them with transcutaneous inductive power transmission from a behind the ear (BTE) rechargeable energy source, similar to cochlear implants and hearing aids [7]–[10].”
BackgroundJow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630 · cited 1×
“If the efficiency of the transcutaneous inductive link is 60% at 10 mm coil separation from [36], the necessary Tx power at 2 MHz can be estimated at 25 mW.”
BackgroundSelf-citationDesign and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591 · cited 1×
“This is possible via a multi-coil inductive link or an adaptive resonant load transformation [16], [17].”
BackgroundSelf-citationSelection of stimulus parameters for deep brain stimulation
Kuncel, A. M., & Grill, W. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.05.031 · Cited by 458 · cited 1×
“Deep brain stimulation (DBS) is one of the most effective examples of such therapies to treat Parkinson’s disease, tremor, and dystonia [4], [5].”
BackgroundXue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340 · cited 1×
“This is possible via a multi-coil inductive link or an adaptive resonant load transformation [16], [17].”
BackgroundFully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Self-citationAn Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266 · cited 3×
“2(a) utilizes a rectifier to convert the AC input to a DC , followed by a low-dropout regulator (LDO) to generate a fixed supply voltage, [3].”
BackgroundMethodThe 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
Guo, S., & Lee, H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2020195 · Cited by 253
Self-citationPower harvesting and telemetry in CMOS for implanted devices
Sauer, C., Stanacevic, M., Cauwenberghs, G., & Thakor, N. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.858183 · Cited by 249
Lee, H.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2010.2103172 · Cited by 227 · cited 2×
“The difference between simulated and measured PCEs may be the result of mismatches between rectifying switches and their phase control comparators, as well as the effects of parasitic inductance and capacitance of the measurement setup, as explained in [22].”
BackgroundSelf-citationA 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225 · cited 1×
“Active charge balancing circuits push or pull additional small current pulses to the load after stimulation until the residual site voltage settles within a mV safety window [25].”
BackgroundThermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain
Kim, S., Tathireddy, P., Normann, R. A., & Solzbacher, F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908429 · Cited by 214 · cited 1×
“15 mW, assuming constantly flowing stimulus current, resulting in temperature rise well below the safe 1 C limit [35].”
BackgroundNoorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212 · cited 3×
“The 5-bit current sources with binary-weighted transistors are placed at the output stage directly to reduce the stimulator power loss compared to using current mirrors after a 5-bit current DAC in [20].”
BackgroundMethodSpatial steering of deep brain stimulation volumes using a novel lead design
Martens, H. C. F., Toader, E., Decré, M. M. J., Anderson, D. J., Vetter, R., Kipke, D. R., Baker, K. B., Johnson, M. D., & Vitek, J. L. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.07.026 · Cited by 195 · cited 13×
“15 when mA biphasic-bipolar stimulus currents at s flow between through a series load, which was chosen to be 2 k and 500 nF for the DBS application [19], [29].”
InfluentialAn inductive power system with integrated bi-directional data-transmission
Catrysse, M., Hermans, B., & Puers, R. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.02.016 · Cited by 177 · cited 1×
“A head-mounted DBS can eliminate hardship imposed by chest-implanted primary batteries and long interconnects across the neck, replacing them with transcutaneous inductive power transmission from a behind the ear (BTE) rechargeable energy source, similar to cochlear implants and hearing aids [7]–[10].”
BackgroundAn active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170 · cited 1×
“9(a), the electrodes and tissue model is simplified to a series and , which represent the solution spreading resistance and the double-layer capacitance, respectively, while two current drivers across the two sites apply bipolar stimulation [26], [27].”
BackgroundSit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155 · cited 2×
“the other hand, have difficulty in defining the current and period needed for charge balancing [27].”
BackgroundImpedance characteristics of deep brain stimulation electrodes in vitro and in vivo
Wei, X. F., & Grill, W. M. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046008 · Cited by 155 · cited 1×
“s flow between through a series load, which was chosen to be 2 k and 500 nF for the DBS application [19], [29].”
BackgroundA Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
Ghovanloo, M., & Najafi, K. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903970 · Cited by 137
Self-citationArfin, S. K., & Sarpeshkar, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2166072 · Cited by 133 · cited 3×
“s flow between through a series load, which was chosen to be 2 k and 500 nF for the DBS application [19], [29].”
BackgroundMethodA Power-Efficient Neural Tissue Stimulator With Energy Recovery
Kelly, S. K., & Wyatt, J. L. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2076384 · Cited by 107 · cited 1×
“SCS takes advantages of both high efficiency and safety by using capacitor banks to store and transfer charge to the tissue [13], [15].”
BackgroundBulletin, O., Cleveland, R. F., & Ulcek, J. L. (1999) · Cited by 104
Lee, H., & Ghovanloo, M. (2012) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2012.6177017 · Cited by 100
Self-citationA novel low-drop CMOS active rectifier for RF-powered devices: Experimental results
Hashemi, S., Sawan, M., & Savaria, Y. (2009) · Microelectronics Journal · doi:10.1016/j.mejo.2009.02.007 · Cited by 74
An Experimental Study of Voltage, Current, and Charge Controlled Stimulation Front-End Circuitry
Simpson, J., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2007.378401 · Cited by 65 · cited 1×
“Conversely, CCS has been widely used because of its precise charge control and safe operation [14].”
BackgroundSelf-citationLee, H., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2012.2204840 · Cited by 58 · cited 4×
“, injects additional current when is high and turns on, forcing to increase earlier and expedite the turn-on transition of [24].”
BackgroundInfluentialSelf-citationBawa, G., & Ghovanloo, M. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.924444 · Cited by 56
Self-citationA Tripolar Current-Steering Stimulator ASIC for Field Shaping in Deep Brain Stimulation
Valente, V., Demosthenous, A., & Bayford, R. H. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2171036 · Cited by 40
Towards a Switched-Capacitor based Stimulator for efficient deep-brain stimulation
Vidal, J. G., & Ghovanloo, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626290 · Cited by 33
Self-citationPsychiatry's shocking new tools [brain stimulation techniques]
Moore, S. K. (2006) · IEEE Spectrum · doi:10.1109/mspec.2006.1604837 · Cited by 22
Xu, H., Noorsal, E., Sooksood, K., Becker, J., & Ortmanns, M. (2012) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2012.6341316 · Cited by 18 · cited 2×
“Various inductively-powered stimulating structures with (a) the conventional rectifier and regulator [3], (b) the fixed output rectifier [18], (c) the dynamic dc-dc converter [19], (d) the external closed-loop supply control [20], [21], and (e) the internal closed-loop supply control with the proposed adaptive rectifi…”
BackgroundMethod
Cited by
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“[91] uses the offset regulation method.”
MethodJiang, Y., Wang, L., Wang, Y., Liu, J., Wu, M., & Ning, G. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2873222 · Cited by 180
Lee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161
Self-citationButz, N., Taschwer, A., Nessler, S., Manoli, Y., & Kuhl, M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2828823 · Cited by 70
“Therefore, in contrast to [10] and [17], this paper features 22 V compliance (±11 V with respect to VCM), limited by the used 0.”
BackgroundMethodHsu, W.-Y., & Schmid, A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2694144 · Cited by 49
Metadata
- Authors
- Lee, H.-M., Park, H., & Ghovanloo, M.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2013-09
- Volume
- 48
- Issue
- 9
- Pages
- 2203-2216
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2046820813
- Cited by
- 232
- References
- 33
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.